4 vulnerabilities found for simatic_wincc_sm\@rtclient_lite by siemens

CVE-2017-6871 (GCVE-0-2017-6871)

Vulnerability from nvd – Published: 2017-08-08 00:00 – Updated: 2024-08-05 15:41
VLAI?
Summary
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app's authentication mechanism under certain conditions.
Severity ?
No CVSS data available.
CWE
  • CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Assigner
References
Impacted products
Vendor Product Version
n/a SIMATIC WinCC Sm@rtClient for Android, SIMATIC WinCC Sm@rtClient Lite for Android Affected: SIMATIC WinCC Sm@rtClient for Android, SIMATIC WinCC Sm@rtClient Lite for Android
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:41:17.693Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "99582",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99582"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-589378.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC WinCC Sm@rtClient for Android, SIMATIC WinCC Sm@rtClient Lite for Android",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "SIMATIC WinCC Sm@rtClient for Android, SIMATIC WinCC Sm@rtClient Lite for Android"
            }
          ]
        }
      ],
      "datePublic": "2017-08-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app\u0027s authentication mechanism under certain conditions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-288",
              "description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-08T09:57:01",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "99582",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99582"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-589378.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2017-6871",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC WinCC Sm@rtClient for Android, SIMATIC WinCC Sm@rtClient Lite for Android",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "SIMATIC WinCC Sm@rtClient for Android, SIMATIC WinCC Sm@rtClient Lite for Android"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app\u0027s authentication mechanism under certain conditions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-288: Authentication Bypass Using an Alternate Path or Channel"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "99582",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99582"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-589378.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-589378.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-6871",
    "datePublished": "2017-08-08T00:00:00",
    "dateReserved": "2017-03-13T00:00:00",
    "dateUpdated": "2024-08-05T15:41:17.693Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2015-5084 (GCVE-0-2015-5084)

Vulnerability from nvd – Published: 2015-08-03 01:00 – Updated: 2024-08-06 06:32
VLAI?
Summary
The Siemens SIMATIC WinCC Sm@rtClient and Sm@rtClient Lite applications before 01.00.01.00 for Android do not properly store passwords, which allows physically proximate attackers to obtain sensitive information via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T06:32:32.732Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-267489.pdf"
          },
          {
            "name": "75981",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/75981"
          },
          {
            "name": "1033021",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1033021"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-07-21T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Siemens SIMATIC WinCC Sm@rtClient and Sm@rtClient Lite applications before 01.00.01.00 for Android do not properly store passwords, which allows physically proximate attackers to obtain sensitive information via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-09-20T09:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-267489.pdf"
        },
        {
          "name": "75981",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/75981"
        },
        {
          "name": "1033021",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1033021"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2015-5084",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Siemens SIMATIC WinCC Sm@rtClient and Sm@rtClient Lite applications before 01.00.01.00 for Android do not properly store passwords, which allows physically proximate attackers to obtain sensitive information via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-267489.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-267489.pdf"
            },
            {
              "name": "75981",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/75981"
            },
            {
              "name": "1033021",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1033021"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2015-5084",
    "datePublished": "2015-08-03T01:00:00",
    "dateReserved": "2015-06-26T00:00:00",
    "dateUpdated": "2024-08-06T06:32:32.732Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-6871 (GCVE-0-2017-6871)

Vulnerability from cvelistv5 – Published: 2017-08-08 00:00 – Updated: 2024-08-05 15:41
VLAI?
Summary
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app's authentication mechanism under certain conditions.
Severity ?
No CVSS data available.
CWE
  • CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Assigner
References
Impacted products
Vendor Product Version
n/a SIMATIC WinCC Sm@rtClient for Android, SIMATIC WinCC Sm@rtClient Lite for Android Affected: SIMATIC WinCC Sm@rtClient for Android, SIMATIC WinCC Sm@rtClient Lite for Android
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:41:17.693Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "99582",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99582"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-589378.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC WinCC Sm@rtClient for Android, SIMATIC WinCC Sm@rtClient Lite for Android",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "SIMATIC WinCC Sm@rtClient for Android, SIMATIC WinCC Sm@rtClient Lite for Android"
            }
          ]
        }
      ],
      "datePublic": "2017-08-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app\u0027s authentication mechanism under certain conditions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-288",
              "description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-08T09:57:01",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "99582",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99582"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-589378.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2017-6871",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC WinCC Sm@rtClient for Android, SIMATIC WinCC Sm@rtClient Lite for Android",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "SIMATIC WinCC Sm@rtClient for Android, SIMATIC WinCC Sm@rtClient Lite for Android"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app\u0027s authentication mechanism under certain conditions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-288: Authentication Bypass Using an Alternate Path or Channel"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "99582",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99582"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-589378.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-589378.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-6871",
    "datePublished": "2017-08-08T00:00:00",
    "dateReserved": "2017-03-13T00:00:00",
    "dateUpdated": "2024-08-05T15:41:17.693Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2015-5084 (GCVE-0-2015-5084)

Vulnerability from cvelistv5 – Published: 2015-08-03 01:00 – Updated: 2024-08-06 06:32
VLAI?
Summary
The Siemens SIMATIC WinCC Sm@rtClient and Sm@rtClient Lite applications before 01.00.01.00 for Android do not properly store passwords, which allows physically proximate attackers to obtain sensitive information via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T06:32:32.732Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-267489.pdf"
          },
          {
            "name": "75981",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/75981"
          },
          {
            "name": "1033021",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1033021"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-07-21T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Siemens SIMATIC WinCC Sm@rtClient and Sm@rtClient Lite applications before 01.00.01.00 for Android do not properly store passwords, which allows physically proximate attackers to obtain sensitive information via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-09-20T09:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-267489.pdf"
        },
        {
          "name": "75981",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/75981"
        },
        {
          "name": "1033021",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1033021"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2015-5084",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Siemens SIMATIC WinCC Sm@rtClient and Sm@rtClient Lite applications before 01.00.01.00 for Android do not properly store passwords, which allows physically proximate attackers to obtain sensitive information via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-267489.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-267489.pdf"
            },
            {
              "name": "75981",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/75981"
            },
            {
              "name": "1033021",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1033021"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2015-5084",
    "datePublished": "2015-08-03T01:00:00",
    "dateReserved": "2015-06-26T00:00:00",
    "dateUpdated": "2024-08-06T06:32:32.732Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}