Search
Find a vulnerability
Search criteria
6 vulnerabilities found for simatic_winac_rtx_2010 by siemens
CVE-2019-10936 (GCVE-0-2019-10936)
Vulnerability from nvd – Published: 2019-10-10 00:00 – Updated: 2024-08-04 22:40
VLAI
EPSS
VEX
Summary
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-09 14:36 UTC
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
Impacted products
157 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Affected:
0 , < *
(custom)
|
|
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P |
Affected:
All versions < V4.6 Patch 01
|
|
| Siemens | SIMATIC CFU PA |
Affected:
0 , < V1.2.0
(custom)
|
|
| Siemens | SIMATIC ET 200AL IM 157-1 PN |
Affected:
All versions
|
|
| Siemens | SIMATIC ET 200M (incl. SIPLUS variants) |
Affected:
All versions
|
|
| Siemens | SIMATIC ET 200MP IM 155-5 PN BA |
Affected:
0 , < V4.3.0
(custom)
|
|
| Siemens | SIMATIC ET 200MP IM 155-5 PN HF |
Affected:
0 , < V4.4.0
(custom)
|
|
| Siemens | SIMATIC ET 200MP IM 155-5 PN ST |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ET 200pro IM 154-3 PN HF |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ET 200pro IM 154-4 PN HF |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ET 200pro IM 154-8 PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC ET 200pro IM 154-8F PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC ET 200pro IM 154-8FX PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC ET 200S IM 151-8 PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC ET 200S IM 151-8F PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN BA |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) |
Affected:
All versions < V1.2.1
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN HF |
Affected:
0 , < V4.2.2
(custom)
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN HS |
Affected:
0 , < V4.0.1
(custom)
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN ST |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN ST BA |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN/2 HF |
Affected:
0 , < V4.2.2
(custom)
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN/3 HF |
Affected:
0 , < V4.2.1
(custom)
|
|
| Siemens | SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) |
Affected:
0 , < V2.0
(custom)
|
|
| Siemens | SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 4AO U/I 4xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN: IO-Link Master |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200S (incl. SIPLUS variants) |
Affected:
All versions
|
|
| Siemens | SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC HMI Comfort Panels (incl. SIPLUS variants) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC HMI KTP Mobile Panels |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC PN/PN Coupler |
Affected:
All versions < V4.2.1
|
|
| Siemens | SIMATIC PROFINET Driver |
Affected:
All versions < V2.1
|
|
| Siemens | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) |
Affected:
All versions < V4.4.0
|
|
| Siemens | SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) |
Affected:
All versions < V2.0
|
|
| Siemens | SIMATIC S7-1500 Software Controller |
Affected:
All versions < V2.0
|
|
| Siemens | SIMATIC S7-300 CPU 314C-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 315-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 315F-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 315T-3 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 317-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 317F-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 317T-3 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 317TF-3 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 319-3 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 319F-3 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-400 CPU 412-2 PN V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| Siemens | SIMATIC S7-400 CPU 414-3 PN/DP V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| Siemens | SIMATIC S7-400 CPU 414F-3 PN/DP V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| Siemens | SIMATIC S7-400 CPU 416-3 PN/DP V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| Siemens | SIMATIC S7-400 CPU 416F-3 PN/DP V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| Siemens | SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) |
Affected:
0 , < V6.0.9
(custom)
|
|
| Siemens | SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) |
Affected:
All versions < V8.2.2
|
|
| Siemens | SIMATIC TDC CP51M1 |
Affected:
0 , < V1.1.8
(custom)
|
|
| Siemens | SIMATIC TDC CPU555 |
Affected:
0 , < V1.1.1
(custom)
|
|
| Siemens | SIMATIC WinAC RTX 2010 |
Affected:
All versions < V2010 SP3
|
|
| Siemens | SIMATIC WinAC RTX F 2010 |
Affected:
All versions < V2010 SP3
|
|
| Siemens | SINAMICS DCM |
Affected:
All versions < V1.5 HF1
|
|
| Siemens | SINAMICS DCP |
Affected:
All versions < V1.3
|
|
| Siemens | SINAMICS G110M V4.7 PN Control Unit |
Affected:
All versions < V4.7 SP10 HF5
|
|
| Siemens | SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants) |
Affected:
All versions < V4.7 SP10 HF5
|
|
| Siemens | SINAMICS G130 V4.7 Control Unit |
Affected:
All versions < 4.8
|
|
| Siemens | SINAMICS G150 Control Unit |
Affected:
All versions < 4.8
|
|
| Siemens | SINAMICS GH150 V4.7 Control Unit |
Affected:
All versions
|
|
| Siemens | SINAMICS GL150 V4.7 Control Unit |
Affected:
All versions
|
|
| Siemens | SINAMICS GM150 V4.7 Control Unit |
Affected:
All versions
|
|
| Siemens | SINAMICS S110 Control Unit |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS S150 Control Unit |
Affected:
All versions < 4.8
|
|
| Siemens | SINAMICS SL150 V4.7 Control Unit |
Affected:
All versions < V4.7 HF33
|
|
| Siemens | SINAMICS SM120 V4.7 Control Unit |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINUMERIK 828D |
Affected:
All versions < V4.8 SP5
|
|
| Siemens | SINUMERIK 840D sl |
Affected:
All versions < V4.8 SP6
|
|
| Siemens | SIPLUS ET 200MP IM 155-5 PN HF |
Affected:
0 , < V4.4.0
(custom)
|
|
| Siemens | SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL |
Affected:
0 , < V4.4.0
(custom)
|
|
| Siemens | SIPLUS ET 200MP IM 155-5 PN ST |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS ET 200MP IM 155-5 PN ST TX RAIL |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS ET 200S IM 151-8 PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIPLUS ET 200S IM 151-8F PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF |
Affected:
0 , < V4.2.2
(custom)
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL |
Affected:
0 , < V4.2.2
(custom)
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF TX RAIL |
Affected:
0 , < V4.2.2
(custom)
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN ST |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN ST BA |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN ST TX RAIL |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS NET PN/PN Coupler |
Affected:
All versions < V4.2.1
|
|
| Siemens | SIPLUS S7-300 CPU 314C-2 PN/DP |
Affected:
All versions < V3.3.17
|
|
| Siemens | SIPLUS S7-300 CPU 315-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIPLUS S7-300 CPU 315F-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIPLUS S7-300 CPU 317-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIPLUS S7-300 CPU 317F-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIPLUS S7-400 CPU 414-3 PN/DP V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| Siemens | SIPLUS S7-400 CPU 416-3 PN/DP V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| siemens | dk_standard_ethernet_controller_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:* |
|
| siemens | ek-ertec_200_firmware |
Affected:
0 , < *
(custom)
cpe:2.3:o:siemens:ek-ertec_200_firmware:-:*:*:*:*:*:*:* |
|
| siemens | ek-ertec_200p_firmware |
Affected:
0 , < 4.6
(custom)
cpe:2.3:o:siemens:ek-ertec_200p_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_cfu_pa |
Affected:
0 , < v1.2.0
(custom)
cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et200ecopn_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_et200ecopn_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et200s_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_et200s_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et_200al_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et_200m_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et_200mp_firmware |
Affected:
0 , < v4.3.0
(custom)
cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et_200pro_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et_200s_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et_200sp_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_hmi_comfort_outdoor_panels |
Affected:
0 , ≤ *
(custom)
cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:* |
|
| siemens | simatic_pn\/pn_coupler_6es7158-3ad01-0xa0 |
Affected:
0 , < v4.2.1
(custom)
cpe:2.3:h:siemens:simatic_pn\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:* |
|
| siemens | simatic_profinet_driver |
Affected:
0 , < v2.1
(custom)
cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-300_cpu_314_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-300_cpu_315-2_dp_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-300_cpu_315f-2_dp_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-300_cpu_317-2_dp_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-300_cpu_317-2_pn\/dp_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn\/dp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-300_cpu_319-3_pn\/dp_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_s7-300_cpu_319-3_pn\/dp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-400_cpu_412-2_pn |
Affected:
0 , < v7.0.3
(custom)
cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-400_cpu_414-3_pn\/dp |
Affected:
0 , < v7.0.3
(custom)
cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\/dp:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-400_cpu_416-3_pn\/dp |
Affected:
0 , ≤ v7.0.3
(custom)
cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\/dp:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-400_h_v6_firmware |
Affected:
0 , ≤ v6.0.9
(custom)
cpe:2.3:o:siemens:simatic_s7-400_h_v6_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-400_pn\/dp_v6_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_s7-400_pn\/dp_v6_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-410_cpu_firmware |
Affected:
0 , < v8.2.2
(custom)
cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-1200_cpu |
Affected:
0 , < v4.4.0
(custom)
cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-1500_cpu |
Affected:
0 , < v2.0
(custom)
cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-1500_controller |
Affected:
0 , < v2.0
(custom)
cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:* |
|
| siemens | simatic_tdc_cp51m1_firmware |
Affected:
0 , < v1.1.8
(custom)
cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_tdc_cpu555_firmware |
Affected:
0 , < v1.1.1
(custom)
cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_winac_rtx_2010 |
Affected:
0 , < v2010_sp3
(custom)
cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:* |
|
| siemens | simatic_winac_rtx_\(f\)_2010 |
Affected:
0 , < v2010_sp3
(custom)
cpe:2.3:h:siemens:simatic_winac_rtx_\(f\)_2010:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_dcm |
Affected:
0 , < v1.5_hf1
(custom)
cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_dcp |
Affected:
0 , < v1.3
(custom)
cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_g110m |
Affected:
0 , < v4.7_sp10_hf5
(custom)
cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_g120 |
Affected:
0 , < v4.7_sp10_hf5
(custom)
cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_g130 |
Affected:
0 , < v4.8
(custom)
cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_g150 |
Affected:
0 , < v4.8
(custom)
cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_gh150 |
Affected:
0 , ≤ *
(custom)
cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_gl150 |
Affected:
0 , ≤ *
(custom)
cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_gm150 |
Affected:
0 , < *
(custom)
cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_s110 |
Affected:
0 , ≤ *
(custom)
cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_s120 |
Affected:
0 , ≤ *
(custom)
cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_sl150 |
Affected:
0 , < v4.8
(custom)
cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_sl150 |
Affected:
0 , < v4.7_hf33
(custom)
cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_sm120 |
Affected:
0 , ≤ *
(custom)
cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:* |
|
| siemens | sinumerik_828d |
Affected:
0 , < v4.8_sp5
(custom)
cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:* |
|
| siemens | sinumerik_840d_sl |
Affected:
0 , < v4.8_sp6
(custom)
cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:* |
|
| siemens | siplus_s7-300_cpu_314 |
Affected:
0 , < v3.3.17
(custom)
cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "dk_standard_ethernet_controller_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:ek-ertec_200_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ek-ertec_200_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:ek-ertec_200p_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ek-ertec_200p_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cfu_pa",
"vendor": "siemens",
"versions": [
{
"lessThan": "v1.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et200ecopn_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et200ecopn_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et200s_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et200s_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et_200al_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et_200m_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et_200mp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et_200pro_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et_200s_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et_200sp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_hmi_comfort_outdoor_panels",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_profinet_driver",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-300_cpu_314_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-300_cpu_315-2_dp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-300_cpu_315f-2_dp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-300_cpu_317-2_dp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-300_cpu_317-2_pn\\/dp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-300_cpu_319-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-300_cpu_319-3_pn\\/dp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-400_cpu_412-2_pn",
"vendor": "siemens",
"versions": [
{
"lessThan": "v7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-400_cpu_414-3_pn\\/dp",
"vendor": "siemens",
"versions": [
{
"lessThan": "v7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-400_cpu_416-3_pn\\/dp",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "v7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-400_h_v6_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-400_h_v6_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "v6.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v6_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-400_pn\\/dp_v6_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-410_cpu_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v8.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-1200_cpu",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-1500_cpu",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-1500_controller",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_tdc_cp51m1_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v1.1.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_tdc_cpu555_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v1.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_winac_rtx_2010",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2010_sp3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_winac_rtx_\\(f\\)_2010",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2010_sp3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_dcm",
"vendor": "siemens",
"versions": [
{
"lessThan": "v1.5_hf1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_dcp",
"vendor": "siemens",
"versions": [
{
"lessThan": "v1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_g110m",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.7_sp10_hf5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_g120",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.7_sp10_hf5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_g130",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_g150",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_gh150",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_gl150",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_gm150",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_s110",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_s120",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_sl150",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_sl150",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.7_hf33",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_sm120",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinumerik_828d",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.8_sp5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinumerik_840d_sl",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.8_sp6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-300_cpu_314",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-10936",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T14:36:59.481395Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T15:59:12.602Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.253Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.6 Patch 01"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CFU PA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200AL IM 157-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200M (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-3 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-4 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM 151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM 151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN/2 HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN/3 HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN: IO-Link Master",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200S (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI KTP Mobile Panels",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/PN Coupler",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PROFINET Driver",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 412-2 PN V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CP51M1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CPU555",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.5 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G110M V4.7 PN Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP10 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP10 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 4.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 4.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GH150 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GL150 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GM150 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S110 Control Unit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 4.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF33"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM120 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM 151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM 151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET PN/PN Coupler",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T12:03:55.957Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10936",
"datePublished": "2019-10-10T00:00:00.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.253Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-6865 (GCVE-0-2017-6865)
Vulnerability from nvd – Published: 2017-05-11 10:00 – Updated: 2024-08-05 15:41
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.
Severity
No CVSS data available.
CWE
- Other
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.securityfocus.com/bid/98366 | vdb-entryx_refsource_BID |
Impacted products
22 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | Primary Setup Tool (PST) |
Affected:
All versions < V4.2 HF1
|
|
| Siemens AG | SIMATIC Automation Tool |
Affected:
All versions < V3.0
|
|
| Siemens AG | SIMATIC NET PC-Software |
Affected:
All versions < V14 SP1
|
|
| Siemens AG | SIMATIC PCS 7 V8.1 |
Affected:
All versions
|
|
| Siemens AG | SIMATIC PCS 7 V8.2 |
Affected:
All versions < V8.2 SP1
|
|
| Siemens AG | SIMATIC STEP 7 (TIA Portal) V13 |
Affected:
All versions < V13 SP2
|
|
| Siemens AG | SIMATIC STEP 7 (TIA Portal) V14 |
Affected:
All versions < V14 SP1
|
|
| Siemens AG | SIMATIC STEP 7 V5.X |
Affected:
All versions < V5.6
|
|
| Siemens AG | SIMATIC WinAC RTX 2010 SP2 |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinAC RTX F 2010 SP2 |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) V13 |
Affected:
All versions < V13 SP2
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) V14 |
Affected:
All versions < V14 SP1
|
|
| Siemens AG | SIMATIC WinCC V7.2 and prior |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinCC V7.3 |
Affected:
All versions < V7.3 Update 15
|
|
| Siemens AG | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Upd1
|
|
| Siemens AG | SIMATIC WinCC flexible 2008 |
Affected:
All versions < flexible 2008 SP5
|
|
| Siemens AG | SINAUT ST7CC |
Affected:
All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15
|
|
| Siemens AG | SINEMA Server |
Affected:
All versions < V14
|
|
| Siemens AG | SINUMERIK 808D Programming Tool |
Affected:
All versions < V4.7 SP4 HF2
|
|
| Siemens AG | SMART PC Access |
Affected:
All versions < V2.3
|
|
| Siemens AG | STEP 7 - Micro/WIN SMART |
Affected:
All versions < V2.3
|
|
| Siemens AG | Security Configuration Tool (SCT) |
Affected:
All versions < V5.0
|
Date Public
2017-05-10 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:41:17.697Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"
},
{
"name": "98366",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "https://www.securityfocus.com/bid/98366"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Primary Setup Tool (PST)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2 HF1"
}
]
},
{
"product": "SIMATIC Automation Tool",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"product": "SIMATIC NET PC-Software",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1"
}
]
},
{
"product": "SIMATIC PCS 7 V8.1",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2 SP1"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V13",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V14",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1"
}
]
},
{
"product": "SIMATIC STEP 7 V5.X",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.6"
}
]
},
{
"product": "SIMATIC WinAC RTX 2010 SP2",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinAC RTX F 2010 SP2",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V13",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V14",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1"
}
]
},
{
"product": "SIMATIC WinCC V7.2 and prior",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC V7.3",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.3 Update 15"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Upd1"
}
]
},
{
"product": "SIMATIC WinCC flexible 2008",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c flexible 2008 SP5"
}
]
},
{
"product": "SINAUT ST7CC",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15"
}
]
},
{
"product": "SINEMA Server",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14"
}
]
},
{
"product": "SINUMERIK 808D Programming Tool",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF2"
}
]
},
{
"product": "SMART PC Access",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3"
}
]
},
{
"product": "STEP 7 - Micro/WIN SMART",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3"
}
]
},
{
"product": "Security Configuration Tool (SCT)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0"
}
]
},
{
"product": "Security Configuration Tool (SCT)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0"
}
]
}
],
"datePublic": "2017-05-10T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC Automation Tool (All versions \u003c V3.0), SIMATIC NET PC-Software (All versions \u003c V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC STEP 7 V5.X (All versions \u003c V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Update 15), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions \u003c flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15), SINEMA Server (All versions \u003c V14), SINUMERIK 808D Programming Tool (All versions \u003c V4.7 SP4 HF2), SMART PC Access (All versions \u003c V2.3), STEP 7 - Micro/WIN SMART (All versions \u003c V2.3), Security Configuration Tool (SCT) (All versions \u003c V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Other",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-21T15:44:20.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"
},
{
"name": "98366",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "https://www.securityfocus.com/bid/98366"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2017-6865",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Primary Setup Tool (PST)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.2 HF1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC Automation Tool",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC NET PC-Software",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.1",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.2 SP1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V13",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13 SP2"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC STEP 7 V5.X",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.6"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinAC RTX 2010 SP2",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinAC RTX F 2010 SP2",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC (TIA Portal) V13",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13 SP2"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC (TIA Portal) V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC V7.2 and prior",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC V7.3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.3 Update 15"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC V7.4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.4 SP1 Upd1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC flexible 2008",
"version": {
"version_data": [
{
"version_value": "All versions \u003c flexible 2008 SP5"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SINAUT ST7CC",
"version": {
"version_data": [
{
"version_value": "All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SINEMA Server",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SINUMERIK 808D Programming Tool",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.7 SP4 HF2"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SMART PC Access",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.3"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "STEP 7 - Micro/WIN SMART",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.3"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "Security Configuration Tool (SCT)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.0"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "Security Configuration Tool (SCT)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.0"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC Automation Tool (All versions \u003c V3.0), SIMATIC NET PC-Software (All versions \u003c V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC STEP 7 V5.X (All versions \u003c V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Update 15), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions \u003c flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15), SINEMA Server (All versions \u003c V14), SINUMERIK 808D Programming Tool (All versions \u003c V4.7 SP4 HF2), SMART PC Access (All versions \u003c V2.3), STEP 7 - Micro/WIN SMART (All versions \u003c V2.3), Security Configuration Tool (SCT) (All versions \u003c V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Other"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"
},
{
"name": "98366",
"refsource": "BID",
"url": "https://www.securityfocus.com/bid/98366"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2017-6865",
"datePublished": "2017-05-11T10:00:00.000Z",
"dateReserved": "2017-03-13T00:00:00.000Z",
"dateUpdated": "2024-08-05T15:41:17.697Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-7165 (GCVE-0-2016-7165)
Vulnerability from nvd – Published: 2016-11-15 19:00 – Updated: 2024-08-06 01:50
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02 | x_refsource_MISC |
| http://securityaffairs.co/wordpress/53266/securit… | x_refsource_MISC |
| http://www.securityfocus.com/bid/94158 | vdb-entryx_refsource_BID |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
Date Public
2016-11-07 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T01:50:47.526Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"name": "94158",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/94158"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2016-11-07T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-06-14T20:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"name": "94158",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/94158"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2016-7165",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
},
{
"name": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html",
"refsource": "MISC",
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"name": "94158",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/94158"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2016-7165",
"datePublished": "2016-11-15T19:00:00.000Z",
"dateReserved": "2016-09-08T00:00:00.000Z",
"dateUpdated": "2024-08-06T01:50:47.526Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10936 (GCVE-0-2019-10936)
Vulnerability from cvelistv5 – Published: 2019-10-10 00:00 – Updated: 2024-08-04 22:40
VLAI
EPSS
VEX
Summary
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-09 14:36 UTC
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
Impacted products
157 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Affected:
0 , < *
(custom)
|
|
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P |
Affected:
All versions < V4.6 Patch 01
|
|
| Siemens | SIMATIC CFU PA |
Affected:
0 , < V1.2.0
(custom)
|
|
| Siemens | SIMATIC ET 200AL IM 157-1 PN |
Affected:
All versions
|
|
| Siemens | SIMATIC ET 200M (incl. SIPLUS variants) |
Affected:
All versions
|
|
| Siemens | SIMATIC ET 200MP IM 155-5 PN BA |
Affected:
0 , < V4.3.0
(custom)
|
|
| Siemens | SIMATIC ET 200MP IM 155-5 PN HF |
Affected:
0 , < V4.4.0
(custom)
|
|
| Siemens | SIMATIC ET 200MP IM 155-5 PN ST |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ET 200pro IM 154-3 PN HF |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ET 200pro IM 154-4 PN HF |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ET 200pro IM 154-8 PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC ET 200pro IM 154-8F PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC ET 200pro IM 154-8FX PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC ET 200S IM 151-8 PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC ET 200S IM 151-8F PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN BA |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) |
Affected:
All versions < V1.2.1
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN HF |
Affected:
0 , < V4.2.2
(custom)
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN HS |
Affected:
0 , < V4.0.1
(custom)
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN ST |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN ST BA |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN/2 HF |
Affected:
0 , < V4.2.2
(custom)
|
|
| Siemens | SIMATIC ET 200SP IM 155-6 PN/3 HF |
Affected:
0 , < V4.2.1
(custom)
|
|
| Siemens | SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) |
Affected:
0 , < V2.0
(custom)
|
|
| Siemens | SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 4AO U/I 4xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200ecoPN: IO-Link Master |
Affected:
All versions
|
|
| Siemens | SIMATIC ET200S (incl. SIPLUS variants) |
Affected:
All versions
|
|
| Siemens | SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC HMI Comfort Panels (incl. SIPLUS variants) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC HMI KTP Mobile Panels |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC PN/PN Coupler |
Affected:
All versions < V4.2.1
|
|
| Siemens | SIMATIC PROFINET Driver |
Affected:
All versions < V2.1
|
|
| Siemens | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) |
Affected:
All versions < V4.4.0
|
|
| Siemens | SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) |
Affected:
All versions < V2.0
|
|
| Siemens | SIMATIC S7-1500 Software Controller |
Affected:
All versions < V2.0
|
|
| Siemens | SIMATIC S7-300 CPU 314C-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 315-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 315F-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 315T-3 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 317-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 317F-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 317T-3 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 317TF-3 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 319-3 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-300 CPU 319F-3 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIMATIC S7-400 CPU 412-2 PN V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| Siemens | SIMATIC S7-400 CPU 414-3 PN/DP V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| Siemens | SIMATIC S7-400 CPU 414F-3 PN/DP V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| Siemens | SIMATIC S7-400 CPU 416-3 PN/DP V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| Siemens | SIMATIC S7-400 CPU 416F-3 PN/DP V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| Siemens | SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) |
Affected:
0 , < V6.0.9
(custom)
|
|
| Siemens | SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) |
Affected:
All versions < V8.2.2
|
|
| Siemens | SIMATIC TDC CP51M1 |
Affected:
0 , < V1.1.8
(custom)
|
|
| Siemens | SIMATIC TDC CPU555 |
Affected:
0 , < V1.1.1
(custom)
|
|
| Siemens | SIMATIC WinAC RTX 2010 |
Affected:
All versions < V2010 SP3
|
|
| Siemens | SIMATIC WinAC RTX F 2010 |
Affected:
All versions < V2010 SP3
|
|
| Siemens | SINAMICS DCM |
Affected:
All versions < V1.5 HF1
|
|
| Siemens | SINAMICS DCP |
Affected:
All versions < V1.3
|
|
| Siemens | SINAMICS G110M V4.7 PN Control Unit |
Affected:
All versions < V4.7 SP10 HF5
|
|
| Siemens | SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants) |
Affected:
All versions < V4.7 SP10 HF5
|
|
| Siemens | SINAMICS G130 V4.7 Control Unit |
Affected:
All versions < 4.8
|
|
| Siemens | SINAMICS G150 Control Unit |
Affected:
All versions < 4.8
|
|
| Siemens | SINAMICS GH150 V4.7 Control Unit |
Affected:
All versions
|
|
| Siemens | SINAMICS GL150 V4.7 Control Unit |
Affected:
All versions
|
|
| Siemens | SINAMICS GM150 V4.7 Control Unit |
Affected:
All versions
|
|
| Siemens | SINAMICS S110 Control Unit |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINAMICS S150 Control Unit |
Affected:
All versions < 4.8
|
|
| Siemens | SINAMICS SL150 V4.7 Control Unit |
Affected:
All versions < V4.7 HF33
|
|
| Siemens | SINAMICS SM120 V4.7 Control Unit |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINUMERIK 828D |
Affected:
All versions < V4.8 SP5
|
|
| Siemens | SINUMERIK 840D sl |
Affected:
All versions < V4.8 SP6
|
|
| Siemens | SIPLUS ET 200MP IM 155-5 PN HF |
Affected:
0 , < V4.4.0
(custom)
|
|
| Siemens | SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL |
Affected:
0 , < V4.4.0
(custom)
|
|
| Siemens | SIPLUS ET 200MP IM 155-5 PN ST |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS ET 200MP IM 155-5 PN ST TX RAIL |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS ET 200S IM 151-8 PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIPLUS ET 200S IM 151-8F PN/DP CPU |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF |
Affected:
0 , < V4.2.2
(custom)
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL |
Affected:
0 , < V4.2.2
(custom)
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN HF TX RAIL |
Affected:
0 , < V4.2.2
(custom)
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN ST |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN ST BA |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS ET 200SP IM 155-6 PN ST TX RAIL |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS NET PN/PN Coupler |
Affected:
All versions < V4.2.1
|
|
| Siemens | SIPLUS S7-300 CPU 314C-2 PN/DP |
Affected:
All versions < V3.3.17
|
|
| Siemens | SIPLUS S7-300 CPU 315-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIPLUS S7-300 CPU 315F-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIPLUS S7-300 CPU 317-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIPLUS S7-300 CPU 317F-2 PN/DP |
Affected:
All versions < V3.2.17
|
|
| Siemens | SIPLUS S7-400 CPU 414-3 PN/DP V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| Siemens | SIPLUS S7-400 CPU 416-3 PN/DP V7 |
Affected:
0 , < V7.0.3
(custom)
|
|
| siemens | dk_standard_ethernet_controller_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:* |
|
| siemens | ek-ertec_200_firmware |
Affected:
0 , < *
(custom)
cpe:2.3:o:siemens:ek-ertec_200_firmware:-:*:*:*:*:*:*:* |
|
| siemens | ek-ertec_200p_firmware |
Affected:
0 , < 4.6
(custom)
cpe:2.3:o:siemens:ek-ertec_200p_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_cfu_pa |
Affected:
0 , < v1.2.0
(custom)
cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et200ecopn_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_et200ecopn_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et200s_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_et200s_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et_200al_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et_200m_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et_200mp_firmware |
Affected:
0 , < v4.3.0
(custom)
cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et_200pro_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et_200s_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_et_200sp_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_hmi_comfort_outdoor_panels |
Affected:
0 , ≤ *
(custom)
cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:* |
|
| siemens | simatic_pn\/pn_coupler_6es7158-3ad01-0xa0 |
Affected:
0 , < v4.2.1
(custom)
cpe:2.3:h:siemens:simatic_pn\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:* |
|
| siemens | simatic_profinet_driver |
Affected:
0 , < v2.1
(custom)
cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-300_cpu_314_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-300_cpu_315-2_dp_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-300_cpu_315f-2_dp_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-300_cpu_317-2_dp_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-300_cpu_317-2_pn\/dp_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn\/dp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-300_cpu_319-3_pn\/dp_firmware |
Affected:
0 , < v3.2.17
(custom)
cpe:2.3:o:siemens:simatic_s7-300_cpu_319-3_pn\/dp_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-400_cpu_412-2_pn |
Affected:
0 , < v7.0.3
(custom)
cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-400_cpu_414-3_pn\/dp |
Affected:
0 , < v7.0.3
(custom)
cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\/dp:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-400_cpu_416-3_pn\/dp |
Affected:
0 , ≤ v7.0.3
(custom)
cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\/dp:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-400_h_v6_firmware |
Affected:
0 , ≤ v6.0.9
(custom)
cpe:2.3:o:siemens:simatic_s7-400_h_v6_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-400_pn\/dp_v6_firmware |
Affected:
0 , ≤ *
(custom)
cpe:2.3:o:siemens:simatic_s7-400_pn\/dp_v6_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-410_cpu_firmware |
Affected:
0 , < v8.2.2
(custom)
cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-1200_cpu |
Affected:
0 , < v4.4.0
(custom)
cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-1500_cpu |
Affected:
0 , < v2.0
(custom)
cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:* |
|
| siemens | simatic_s7-1500_controller |
Affected:
0 , < v2.0
(custom)
cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:* |
|
| siemens | simatic_tdc_cp51m1_firmware |
Affected:
0 , < v1.1.8
(custom)
cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_tdc_cpu555_firmware |
Affected:
0 , < v1.1.1
(custom)
cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:-:*:*:*:*:*:*:* |
|
| siemens | simatic_winac_rtx_2010 |
Affected:
0 , < v2010_sp3
(custom)
cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:* |
|
| siemens | simatic_winac_rtx_\(f\)_2010 |
Affected:
0 , < v2010_sp3
(custom)
cpe:2.3:h:siemens:simatic_winac_rtx_\(f\)_2010:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_dcm |
Affected:
0 , < v1.5_hf1
(custom)
cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_dcp |
Affected:
0 , < v1.3
(custom)
cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_g110m |
Affected:
0 , < v4.7_sp10_hf5
(custom)
cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_g120 |
Affected:
0 , < v4.7_sp10_hf5
(custom)
cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_g130 |
Affected:
0 , < v4.8
(custom)
cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_g150 |
Affected:
0 , < v4.8
(custom)
cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_gh150 |
Affected:
0 , ≤ *
(custom)
cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_gl150 |
Affected:
0 , ≤ *
(custom)
cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_gm150 |
Affected:
0 , < *
(custom)
cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_s110 |
Affected:
0 , ≤ *
(custom)
cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_s120 |
Affected:
0 , ≤ *
(custom)
cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_sl150 |
Affected:
0 , < v4.8
(custom)
cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_sl150 |
Affected:
0 , < v4.7_hf33
(custom)
cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:* |
|
| siemens | sinamics_sm120 |
Affected:
0 , ≤ *
(custom)
cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:* |
|
| siemens | sinumerik_828d |
Affected:
0 , < v4.8_sp5
(custom)
cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:* |
|
| siemens | sinumerik_840d_sl |
Affected:
0 , < v4.8_sp6
(custom)
cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:* |
|
| siemens | siplus_s7-300_cpu_314 |
Affected:
0 , < v3.3.17
(custom)
cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "dk_standard_ethernet_controller_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:ek-ertec_200_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ek-ertec_200_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:ek-ertec_200p_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ek-ertec_200p_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cfu_pa",
"vendor": "siemens",
"versions": [
{
"lessThan": "v1.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et200ecopn_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et200ecopn_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et200s_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et200s_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et_200al_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et_200m_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et_200mp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et_200pro_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et_200s_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_et_200sp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_hmi_comfort_outdoor_panels",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_profinet_driver",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-300_cpu_314_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-300_cpu_315-2_dp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-300_cpu_315f-2_dp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-300_cpu_317-2_dp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-300_cpu_317-2_pn\\/dp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-300_cpu_319-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-300_cpu_319-3_pn\\/dp_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.2.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-400_cpu_412-2_pn",
"vendor": "siemens",
"versions": [
{
"lessThan": "v7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-400_cpu_414-3_pn\\/dp",
"vendor": "siemens",
"versions": [
{
"lessThan": "v7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-400_cpu_416-3_pn\\/dp",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "v7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-400_h_v6_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-400_h_v6_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "v6.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v6_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-400_pn\\/dp_v6_firmware",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-410_cpu_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v8.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-1200_cpu",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-1500_cpu",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_s7-1500_controller",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_tdc_cp51m1_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v1.1.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_tdc_cpu555_firmware",
"vendor": "siemens",
"versions": [
{
"lessThan": "v1.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_winac_rtx_2010",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2010_sp3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_winac_rtx_\\(f\\)_2010",
"vendor": "siemens",
"versions": [
{
"lessThan": "v2010_sp3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_dcm",
"vendor": "siemens",
"versions": [
{
"lessThan": "v1.5_hf1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_dcp",
"vendor": "siemens",
"versions": [
{
"lessThan": "v1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_g110m",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.7_sp10_hf5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_g120",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.7_sp10_hf5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_g130",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_g150",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_gh150",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_gl150",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_gm150",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_s110",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_s120",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_sl150",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_sl150",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.7_hf33",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinamics_sm120",
"vendor": "siemens",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinumerik_828d",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.8_sp5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sinumerik_840d_sl",
"vendor": "siemens",
"versions": [
{
"lessThan": "v4.8_sp6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "siplus_s7-300_cpu_314",
"vendor": "siemens",
"versions": [
{
"lessThan": "v3.3.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-10936",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T14:36:59.481395Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T15:59:12.602Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.253Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.6 Patch 01"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CFU PA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200AL IM 157-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200M (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-3 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-4 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM 151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM 151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN/2 HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN/3 HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN: IO-Link Master",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200S (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI KTP Mobile Panels",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/PN Coupler",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PROFINET Driver",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 412-2 PN V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CP51M1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CPU555",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.5 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G110M V4.7 PN Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP10 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP10 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 4.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 4.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GH150 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GL150 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GM150 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S110 Control Unit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c 4.8"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF33"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM120 V4.7 Control Unit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP6"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.4.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM 151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM 151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET PN/PN Coupler",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T12:03:55.957Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10936",
"datePublished": "2019-10-10T00:00:00.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.253Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-6865 (GCVE-0-2017-6865)
Vulnerability from cvelistv5 – Published: 2017-05-11 10:00 – Updated: 2024-08-05 15:41
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.
Severity
No CVSS data available.
CWE
- Other
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.securityfocus.com/bid/98366 | vdb-entryx_refsource_BID |
Impacted products
22 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | Primary Setup Tool (PST) |
Affected:
All versions < V4.2 HF1
|
|
| Siemens AG | SIMATIC Automation Tool |
Affected:
All versions < V3.0
|
|
| Siemens AG | SIMATIC NET PC-Software |
Affected:
All versions < V14 SP1
|
|
| Siemens AG | SIMATIC PCS 7 V8.1 |
Affected:
All versions
|
|
| Siemens AG | SIMATIC PCS 7 V8.2 |
Affected:
All versions < V8.2 SP1
|
|
| Siemens AG | SIMATIC STEP 7 (TIA Portal) V13 |
Affected:
All versions < V13 SP2
|
|
| Siemens AG | SIMATIC STEP 7 (TIA Portal) V14 |
Affected:
All versions < V14 SP1
|
|
| Siemens AG | SIMATIC STEP 7 V5.X |
Affected:
All versions < V5.6
|
|
| Siemens AG | SIMATIC WinAC RTX 2010 SP2 |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinAC RTX F 2010 SP2 |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) V13 |
Affected:
All versions < V13 SP2
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) V14 |
Affected:
All versions < V14 SP1
|
|
| Siemens AG | SIMATIC WinCC V7.2 and prior |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinCC V7.3 |
Affected:
All versions < V7.3 Update 15
|
|
| Siemens AG | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Upd1
|
|
| Siemens AG | SIMATIC WinCC flexible 2008 |
Affected:
All versions < flexible 2008 SP5
|
|
| Siemens AG | SINAUT ST7CC |
Affected:
All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15
|
|
| Siemens AG | SINEMA Server |
Affected:
All versions < V14
|
|
| Siemens AG | SINUMERIK 808D Programming Tool |
Affected:
All versions < V4.7 SP4 HF2
|
|
| Siemens AG | SMART PC Access |
Affected:
All versions < V2.3
|
|
| Siemens AG | STEP 7 - Micro/WIN SMART |
Affected:
All versions < V2.3
|
|
| Siemens AG | Security Configuration Tool (SCT) |
Affected:
All versions < V5.0
|
Date Public
2017-05-10 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:41:17.697Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"
},
{
"name": "98366",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "https://www.securityfocus.com/bid/98366"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Primary Setup Tool (PST)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2 HF1"
}
]
},
{
"product": "SIMATIC Automation Tool",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"product": "SIMATIC NET PC-Software",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1"
}
]
},
{
"product": "SIMATIC PCS 7 V8.1",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2 SP1"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V13",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V14",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1"
}
]
},
{
"product": "SIMATIC STEP 7 V5.X",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.6"
}
]
},
{
"product": "SIMATIC WinAC RTX 2010 SP2",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinAC RTX F 2010 SP2",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V13",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V14",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1"
}
]
},
{
"product": "SIMATIC WinCC V7.2 and prior",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC V7.3",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.3 Update 15"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Upd1"
}
]
},
{
"product": "SIMATIC WinCC flexible 2008",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c flexible 2008 SP5"
}
]
},
{
"product": "SINAUT ST7CC",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15"
}
]
},
{
"product": "SINEMA Server",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14"
}
]
},
{
"product": "SINUMERIK 808D Programming Tool",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF2"
}
]
},
{
"product": "SMART PC Access",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3"
}
]
},
{
"product": "STEP 7 - Micro/WIN SMART",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3"
}
]
},
{
"product": "Security Configuration Tool (SCT)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0"
}
]
},
{
"product": "Security Configuration Tool (SCT)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0"
}
]
}
],
"datePublic": "2017-05-10T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC Automation Tool (All versions \u003c V3.0), SIMATIC NET PC-Software (All versions \u003c V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC STEP 7 V5.X (All versions \u003c V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Update 15), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions \u003c flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15), SINEMA Server (All versions \u003c V14), SINUMERIK 808D Programming Tool (All versions \u003c V4.7 SP4 HF2), SMART PC Access (All versions \u003c V2.3), STEP 7 - Micro/WIN SMART (All versions \u003c V2.3), Security Configuration Tool (SCT) (All versions \u003c V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Other",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-21T15:44:20.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"
},
{
"name": "98366",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "https://www.securityfocus.com/bid/98366"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2017-6865",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Primary Setup Tool (PST)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.2 HF1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC Automation Tool",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC NET PC-Software",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.1",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.2 SP1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V13",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13 SP2"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC STEP 7 V5.X",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.6"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinAC RTX 2010 SP2",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinAC RTX F 2010 SP2",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC (TIA Portal) V13",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13 SP2"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC (TIA Portal) V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC V7.2 and prior",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC V7.3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.3 Update 15"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC V7.4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.4 SP1 Upd1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SIMATIC WinCC flexible 2008",
"version": {
"version_data": [
{
"version_value": "All versions \u003c flexible 2008 SP5"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SINAUT ST7CC",
"version": {
"version_data": [
{
"version_value": "All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SINEMA Server",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SINUMERIK 808D Programming Tool",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.7 SP4 HF2"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "SMART PC Access",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.3"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "STEP 7 - Micro/WIN SMART",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.3"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "Security Configuration Tool (SCT)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.0"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
},
{
"product": {
"product_data": [
{
"product_name": "Security Configuration Tool (SCT)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.0"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC Automation Tool (All versions \u003c V3.0), SIMATIC NET PC-Software (All versions \u003c V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC STEP 7 V5.X (All versions \u003c V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Update 15), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions \u003c flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15), SINEMA Server (All versions \u003c V14), SINUMERIK 808D Programming Tool (All versions \u003c V4.7 SP4 HF2), SMART PC Access (All versions \u003c V2.3), STEP 7 - Micro/WIN SMART (All versions \u003c V2.3), Security Configuration Tool (SCT) (All versions \u003c V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Other"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"
},
{
"name": "98366",
"refsource": "BID",
"url": "https://www.securityfocus.com/bid/98366"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2017-6865",
"datePublished": "2017-05-11T10:00:00.000Z",
"dateReserved": "2017-03-13T00:00:00.000Z",
"dateUpdated": "2024-08-05T15:41:17.697Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-7165 (GCVE-0-2016-7165)
Vulnerability from cvelistv5 – Published: 2016-11-15 19:00 – Updated: 2024-08-06 01:50
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02 | x_refsource_MISC |
| http://securityaffairs.co/wordpress/53266/securit… | x_refsource_MISC |
| http://www.securityfocus.com/bid/94158 | vdb-entryx_refsource_BID |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
Date Public
2016-11-07 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T01:50:47.526Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"name": "94158",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/94158"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2016-11-07T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-06-14T20:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"name": "94158",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/94158"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2016-7165",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
},
{
"name": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html",
"refsource": "MISC",
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"name": "94158",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/94158"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2016-7165",
"datePublished": "2016-11-15T19:00:00.000Z",
"dateReserved": "2016-09-08T00:00:00.000Z",
"dateUpdated": "2024-08-06T01:50:47.526Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}