Search criteria

4 vulnerabilities found for simatic_step_7_firmware by siemens

CVE-2021-31894 (GCVE-0-2021-31894)

Vulnerability from nvd – Published: 2021-07-13 11:02 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.
Severity ?
No CVSS data available.
CWE
  • CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.952Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.2 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP2"
            }
          ]
        },
        {
          "product": "SIMATIC PDM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.2 SP2"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.7"
            }
          ]
        },
        {
          "product": "SINAMICS STARTER (containing STEP 7 OEM version)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V5.4 SP2 HF1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions \u003c V9.1 SP2), SIMATIC PDM (All versions \u003c V9.2 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 SP2 HF1). A directory containing metafiles relevant to devices\u0027 configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:17:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31894",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.1 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PDM",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.2 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC STEP 7 V5.X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINAMICS STARTER (containing STEP 7 OEM version)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V5.4 SP2 HF1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions \u003c V9.1 SP2), SIMATIC PDM (All versions \u003c V9.2 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 SP2 HF1). A directory containing metafiles relevant to devices\u0027 configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-732: Incorrect Permission Assignment for Critical Resource"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31894",
    "datePublished": "2021-07-13T11:02:58",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.952Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31893 (GCVE-0-2021-31893)

Vulnerability from nvd – Published: 2021-07-13 11:02 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution.
Severity ?
No CVSS data available.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.646Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.2 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP3"
            }
          ]
        },
        {
          "product": "SIMATIC PDM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.2"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.6 SP2 HF3"
            }
          ]
        },
        {
          "product": "SINAMICS STARTER (containing STEP 7 OEM version)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4 HF2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-13T11:02:56",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31893",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PDM",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC STEP 7 V5.X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.6 SP2 HF3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINAMICS STARTER (containing STEP 7 OEM version)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.4 HF2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31893",
    "datePublished": "2021-07-13T11:02:56",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.646Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31894 (GCVE-0-2021-31894)

Vulnerability from cvelistv5 – Published: 2021-07-13 11:02 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.
Severity ?
No CVSS data available.
CWE
  • CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.952Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.2 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP2"
            }
          ]
        },
        {
          "product": "SIMATIC PDM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.2 SP2"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.7"
            }
          ]
        },
        {
          "product": "SINAMICS STARTER (containing STEP 7 OEM version)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V5.4 SP2 HF1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions \u003c V9.1 SP2), SIMATIC PDM (All versions \u003c V9.2 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 SP2 HF1). A directory containing metafiles relevant to devices\u0027 configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:17:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31894",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.1 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PDM",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.2 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC STEP 7 V5.X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINAMICS STARTER (containing STEP 7 OEM version)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V5.4 SP2 HF1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions \u003c V9.1 SP2), SIMATIC PDM (All versions \u003c V9.2 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 SP2 HF1). A directory containing metafiles relevant to devices\u0027 configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-732: Incorrect Permission Assignment for Critical Resource"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31894",
    "datePublished": "2021-07-13T11:02:58",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.952Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31893 (GCVE-0-2021-31893)

Vulnerability from cvelistv5 – Published: 2021-07-13 11:02 – Updated: 2024-08-03 23:10
VLAI?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution.
Severity ?
No CVSS data available.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.646Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.2 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP3"
            }
          ]
        },
        {
          "product": "SIMATIC PDM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.2"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.6 SP2 HF3"
            }
          ]
        },
        {
          "product": "SINAMICS STARTER (containing STEP 7 OEM version)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4 HF2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-13T11:02:56",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31893",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PDM",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC STEP 7 V5.X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.6 SP2 HF3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINAMICS STARTER (containing STEP 7 OEM version)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.4 HF2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31893",
    "datePublished": "2021-07-13T11:02:56",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.646Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}