Search criteria
38 vulnerabilities found for simatic_step_7 by siemens
CVE-2022-46141 (GCVE-0-2022-46141)
Vulnerability from nvd – Published: 2023-12-12 11:25 – Updated: 2024-11-25 21:17
VLAI?
Summary
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.
Severity ?
CWE
- CWE-316 - Cleartext Storage of Sensitive Information in Memory
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | SIMATIC STEP 7 (TIA Portal) |
Affected:
All versions < V19
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:24:03.267Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46141",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-25T21:17:05.789021Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T21:17:26.263Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V19"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions \u003c V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-316",
"description": "CWE-316: Cleartext Storage of Sensitive Information in Memory",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-12T11:25:26.583Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46141",
"datePublished": "2023-12-12T11:25:26.583Z",
"dateReserved": "2022-11-28T16:50:58.483Z",
"dateUpdated": "2024-11-25T21:17:26.263Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25910 (GCVE-0-2023-25910)
Vulnerability from nvd – Published: 2023-06-13 08:17 – Updated: 2024-08-02 11:32
VLAI?
Summary
A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1), SIMATIC S7-PM (All versions < V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server.
An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server.
Severity ?
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC PCS 7 |
Affected:
0 , < V9.1 SP2 UC04
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:32:12.730Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-968170.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.1 SP2 UC04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7 SP1 HF1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7 SP2 HF1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions \u003c V9.1 SP2 UC04), SIMATIC S7-PM (All versions \u003c V5.7 SP1 HF1), SIMATIC S7-PM (All versions \u003c V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions \u003c V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server.\r\n\r\nAn attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system\u0027s server."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:23:34.211Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-968170.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-25910",
"datePublished": "2023-06-13T08:17:04.612Z",
"dateReserved": "2023-02-16T11:12:33.500Z",
"dateUpdated": "2024-08-02T11:32:12.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-42029 (GCVE-0-2021-42029)
Vulnerability from nvd – Published: 2022-04-12 09:07 – Updated: 2024-08-04 03:22
VLAI?
Summary
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions < V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC STEP 7 (TIA Portal) V15 |
Affected:
All versions
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T03:22:25.804Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Update 2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions \u003c V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T09:07:30",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-42029",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 5"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V17",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V17 Update 2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions \u003c V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-42029",
"datePublished": "2022-04-12T09:07:30",
"dateReserved": "2021-10-06T00:00:00",
"dateUpdated": "2024-08-04T03:22:25.804Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7588 (GCVE-0-2020-7588)
Vulnerability from nvd – Published: 2020-07-14 13:18 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.
Severity ?
No CVSS data available.
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Opcenter Execution Discrete |
Affected:
All versions < V3.2
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.850Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V11.3"
}
]
},
{
"product": "Opcenter RD\u0026L",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V8.0"
}
]
},
{
"product": "SIMATIC IT LMS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.6"
}
]
},
{
"product": "SIMATIC IT Production Suite",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.0"
}
]
},
{
"product": "SIMATIC Notifier Server for Windows",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS neo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0 SP1"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMOCODE ES V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 4"
}
]
},
{
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
},
{
"product": "Soft Starter ES V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 3"
}
]
},
{
"product": "Soft Starter ES V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:16:56",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7588",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Opcenter Execution Discrete",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Execution Foundation",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Execution Process",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Intelligence",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.3"
}
]
}
},
{
"product_name": "Opcenter Quality",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V11.3"
}
]
}
},
{
"product_name": "Opcenter RD\u0026L",
"version": {
"version_data": [
{
"version_value": "V8.0"
}
]
}
},
{
"product_name": "SIMATIC IT LMS",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.6"
}
]
}
},
{
"product_name": "SIMATIC IT Production Suite",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.0"
}
]
}
},
{
"product_name": "SIMATIC Notifier Server for Windows",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS neo",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0 SP1"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 5"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 2"
}
]
}
},
{
"product_name": "SIMOCODE ES V15.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 4"
}
]
}
},
{
"product_name": "SIMOCODE ES V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 1"
}
]
}
},
{
"product_name": "Soft Starter ES V15.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 3"
}
]
}
},
{
"product_name": "Soft Starter ES V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20: Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7588",
"datePublished": "2020-07-14T13:18:05",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.850Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7587 (GCVE-0-2020-7587)
Vulnerability from nvd – Published: 2020-07-14 13:18 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
Severity ?
No CVSS data available.
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Opcenter Execution Discrete |
Affected:
All versions < V3.2
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.877Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V11.3"
}
]
},
{
"product": "Opcenter RD\u0026L",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V8.0"
}
]
},
{
"product": "SIMATIC IT LMS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.6"
}
]
},
{
"product": "SIMATIC IT Production Suite",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.0"
}
]
},
{
"product": "SIMATIC Notifier Server for Windows",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS neo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0 SP1"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMOCODE ES V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 4"
}
]
},
{
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
},
{
"product": "Soft Starter ES V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 3"
}
]
},
{
"product": "Soft Starter ES V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:16:51",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7587",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Opcenter Execution Discrete",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Execution Foundation",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Execution Process",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Intelligence",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.3"
}
]
}
},
{
"product_name": "Opcenter Quality",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V11.3"
}
]
}
},
{
"product_name": "Opcenter RD\u0026L",
"version": {
"version_data": [
{
"version_value": "V8.0"
}
]
}
},
{
"product_name": "SIMATIC IT LMS",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.6"
}
]
}
},
{
"product_name": "SIMATIC IT Production Suite",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.0"
}
]
}
},
{
"product_name": "SIMATIC Notifier Server for Windows",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS neo",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0 SP1"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 5"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 2"
}
]
}
},
{
"product_name": "SIMOCODE ES V15.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 4"
}
]
}
},
{
"product_name": "SIMOCODE ES V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 1"
}
]
}
},
{
"product_name": "Soft Starter ES V15.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 3"
}
]
}
},
{
"product_name": "Soft Starter ES V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7587",
"datePublished": "2020-07-14T13:18:05",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.877Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7581 (GCVE-0-2020-7581)
Vulnerability from nvd – Published: 2020-07-14 13:18 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.
Severity ?
No CVSS data available.
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Opcenter Execution Discrete |
Affected:
All versions < V3.2
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.617Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V11.3"
}
]
},
{
"product": "Opcenter RD\u0026L",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V8.0"
}
]
},
{
"product": "SIMATIC Notifier Server for Windows",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS neo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0 SP1"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMOCODE ES V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 4"
}
]
},
{
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
},
{
"product": "Soft Starter ES V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 3"
}
]
},
{
"product": "Soft Starter ES V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "CWE-428: Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:16:47",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7581",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Opcenter Execution Discrete",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Execution Foundation",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Execution Process",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Intelligence",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.3"
}
]
}
},
{
"product_name": "Opcenter Quality",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V11.3"
}
]
}
},
{
"product_name": "Opcenter RD\u0026L",
"version": {
"version_data": [
{
"version_value": "V8.0"
}
]
}
},
{
"product_name": "SIMATIC Notifier Server for Windows",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS neo",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0 SP1"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 5"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 2"
}
]
}
},
{
"product_name": "SIMOCODE ES V15.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 4"
}
]
}
},
{
"product_name": "SIMOCODE ES V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 1"
}
]
}
},
{
"product_name": "Soft Starter ES V15.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 3"
}
]
}
},
{
"product_name": "Soft Starter ES V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-428: Unquoted Search Path or Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7581",
"datePublished": "2020-07-14T13:18:05",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.617Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7586 (GCVE-0-2020-7586)
Vulnerability from nvd – Published: 2020-06-10 16:23 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.
Severity ?
No CVSS data available.
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 and earlier |
Affected:
All versions
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.798Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.2 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3"
}
]
},
{
"product": "SIMATIC PDM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.2"
}
]
},
{
"product": "SIMATIC STEP 7 V5.X",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.6 SP2 HF3"
}
]
},
{
"product": "SINAMICS STARTER (containing STEP 7 OEM version)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.4 HF2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T20:42:20",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7586",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.2 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.0 SP3"
}
]
}
},
{
"product_name": "SIMATIC PDM",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.2"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 V5.X",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.6 SP2 HF3"
}
]
}
},
{
"product_name": "SINAMICS STARTER (containing STEP 7 OEM version)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.4 HF2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7586",
"datePublished": "2020-06-10T16:23:52",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.798Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7585 (GCVE-0-2020-7585)
Vulnerability from nvd – Published: 2020-06-10 16:23 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.
Severity ?
No CVSS data available.
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 and earlier |
Affected:
All versions
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.945Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.2 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3"
}
]
},
{
"product": "SIMATIC PDM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.2"
}
]
},
{
"product": "SIMATIC STEP 7 V5.X",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.6 SP2 HF3"
}
]
},
{
"product": "SINAMICS STARTER (containing STEP 7 OEM version)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.4 HF2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427: Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T20:42:20",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7585",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.2 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.0 SP3"
}
]
}
},
{
"product_name": "SIMATIC PDM",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.2"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 V5.X",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.6 SP2 HF3"
}
]
}
},
{
"product_name": "SINAMICS STARTER (containing STEP 7 OEM version)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.4 HF2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427: Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7585",
"datePublished": "2020-06-10T16:23:39",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.945Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7580 (GCVE-0-2020-7580)
Vulnerability from nvd – Published: 2020-06-10 00:00 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
Severity ?
No CVSS data available.
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Automation Tool |
Affected:
All versions < V4 SP2
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.492Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC Automation Tool",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4 SP2"
}
]
},
{
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 14"
}
]
},
{
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC NET PC Software V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Upd3"
}
]
},
{
"product": "SIMATIC PCS neo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0 SP1"
}
]
},
{
"product": "SIMATIC ProSave",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.8"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V13",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2 Update 4"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 10"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC STEP 7 V5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.6 SP2 HF3"
}
]
},
{
"product": "SIMATIC WinCC OA V3.16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.16 P018"
}
]
},
{
"product": "SIMATIC WinCC OA V3.17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.17 P003"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V13",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2 Update 4"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 10"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 14"
}
]
},
{
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP1 Update 3"
}
]
},
{
"product": "SINAMICS STARTER",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.4 HF2"
}
]
},
{
"product": "SINAMICS Startdrive",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V16 Update 3"
}
]
},
{
"product": "SINEC NMS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0 SP2"
}
]
},
{
"product": "SINEMA Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP3"
}
]
},
{
"product": "SINUMERIK ONE virtual",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V6.14"
}
]
},
{
"product": "SINUMERIK Operate",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V6.14"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "CWE-428: Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-13T00:00:00",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7580",
"datePublished": "2020-06-10T00:00:00",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10929 (GCVE-0-2019-10929)
Vulnerability from nvd – Published: 2019-08-13 18:55 – Updated: 2024-08-04 22:40
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.
Severity ?
No CVSS data available.
CWE
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.230Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V20.8"
}
]
},
{
"product": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 14"
}
]
},
{
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0"
}
]
},
{
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.8.1"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V20.8"
}
]
},
{
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC OA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.16 P013"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:16:07",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC CP 1626",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1 Update 14"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V15",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.4.0"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.8.1"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC S7-PLCSIM Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC OA",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.16 P013"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10929",
"datePublished": "2019-08-13T18:55:57",
"dateReserved": "2019-04-08T00:00:00",
"dateUpdated": "2024-08-04T22:40:15.230Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-7165 (GCVE-0-2016-7165)
Vulnerability from nvd – Published: 2016-11-15 19:00 – Updated: 2024-08-06 01:50
VLAI?
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T01:50:47.526Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"name": "94158",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/94158"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2016-11-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-06-14T20:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"name": "94158",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/94158"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2016-7165",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
},
{
"name": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html",
"refsource": "MISC",
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"name": "94158",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/94158"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2016-7165",
"datePublished": "2016-11-15T19:00:00",
"dateReserved": "2016-09-08T00:00:00",
"dateUpdated": "2024-08-06T01:50:47.526Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-7960 (GCVE-0-2016-7960)
Vulnerability from nvd – Published: 2016-10-13 10:00 – Updated: 2024-08-06 02:13
VLAI?
Summary
Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T02:13:21.400Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03"
},
{
"name": "93551",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/93551"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2016-10-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-12-20T21:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03"
},
{
"name": "93551",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/93551"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2016-7960",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03"
},
{
"name": "93551",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/93551"
},
{
"name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2016-7960",
"datePublished": "2016-10-13T10:00:00",
"dateReserved": "2016-09-09T00:00:00",
"dateUpdated": "2024-08-06T02:13:21.400Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-7959 (GCVE-0-2016-7959)
Vulnerability from nvd – Published: 2016-10-13 10:00 – Updated: 2024-08-06 02:13
VLAI?
Summary
Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T02:13:21.506Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03"
},
{
"name": "93551",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/93551"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2016-10-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-12-20T21:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03"
},
{
"name": "93551",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/93551"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2016-7959",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03"
},
{
"name": "93551",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/93551"
},
{
"name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2016-7959",
"datePublished": "2016-10-13T10:00:00",
"dateReserved": "2016-09-09T00:00:00",
"dateUpdated": "2024-08-06T02:13:21.506Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-1602 (GCVE-0-2015-1602)
Vulnerability from nvd – Published: 2015-04-06 01:00 – Updated: 2024-08-06 04:47
VLAI?
Summary
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T04:47:17.344Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-02-17T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2015-04-06T01:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-1602",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-1602",
"datePublished": "2015-04-06T01:00:00",
"dateReserved": "2015-02-13T00:00:00",
"dateUpdated": "2024-08-06T04:47:17.344Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-1601 (GCVE-0-2015-1601)
Vulnerability from nvd – Published: 2015-04-06 01:00 – Updated: 2024-08-06 04:47
VLAI?
Summary
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T04:47:17.322Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "72691",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/72691"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-02-17T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T14:06:07",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "72691",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/72691"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-1601",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "72691",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/72691"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-1601",
"datePublished": "2015-04-06T01:00:00",
"dateReserved": "2015-02-13T00:00:00",
"dateUpdated": "2024-08-06T04:47:17.322Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46141 (GCVE-0-2022-46141)
Vulnerability from cvelistv5 – Published: 2023-12-12 11:25 – Updated: 2024-11-25 21:17
VLAI?
Summary
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.
Severity ?
CWE
- CWE-316 - Cleartext Storage of Sensitive Information in Memory
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | SIMATIC STEP 7 (TIA Portal) |
Affected:
All versions < V19
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:24:03.267Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46141",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-25T21:17:05.789021Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T21:17:26.263Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V19"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions \u003c V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-316",
"description": "CWE-316: Cleartext Storage of Sensitive Information in Memory",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-12T11:25:26.583Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46141",
"datePublished": "2023-12-12T11:25:26.583Z",
"dateReserved": "2022-11-28T16:50:58.483Z",
"dateUpdated": "2024-11-25T21:17:26.263Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25910 (GCVE-0-2023-25910)
Vulnerability from cvelistv5 – Published: 2023-06-13 08:17 – Updated: 2024-08-02 11:32
VLAI?
Summary
A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1), SIMATIC S7-PM (All versions < V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server.
An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server.
Severity ?
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC PCS 7 |
Affected:
0 , < V9.1 SP2 UC04
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:32:12.730Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-968170.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS 7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.1 SP2 UC04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7 SP1 HF1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-PM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7 SP2 HF1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC STEP 7 V5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions \u003c V9.1 SP2 UC04), SIMATIC S7-PM (All versions \u003c V5.7 SP1 HF1), SIMATIC S7-PM (All versions \u003c V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions \u003c V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server.\r\n\r\nAn attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system\u0027s server."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:23:34.211Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-968170.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-25910",
"datePublished": "2023-06-13T08:17:04.612Z",
"dateReserved": "2023-02-16T11:12:33.500Z",
"dateUpdated": "2024-08-02T11:32:12.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-42029 (GCVE-0-2021-42029)
Vulnerability from cvelistv5 – Published: 2022-04-12 09:07 – Updated: 2024-08-04 03:22
VLAI?
Summary
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions < V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC STEP 7 (TIA Portal) V15 |
Affected:
All versions
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T03:22:25.804Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17 Update 2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions \u003c V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T09:07:30",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-42029",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 5"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V17",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V17 Update 2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions \u003c V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-42029",
"datePublished": "2022-04-12T09:07:30",
"dateReserved": "2021-10-06T00:00:00",
"dateUpdated": "2024-08-04T03:22:25.804Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7587 (GCVE-0-2020-7587)
Vulnerability from cvelistv5 – Published: 2020-07-14 13:18 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
Severity ?
No CVSS data available.
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Opcenter Execution Discrete |
Affected:
All versions < V3.2
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.877Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V11.3"
}
]
},
{
"product": "Opcenter RD\u0026L",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V8.0"
}
]
},
{
"product": "SIMATIC IT LMS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.6"
}
]
},
{
"product": "SIMATIC IT Production Suite",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.0"
}
]
},
{
"product": "SIMATIC Notifier Server for Windows",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS neo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0 SP1"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMOCODE ES V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 4"
}
]
},
{
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
},
{
"product": "Soft Starter ES V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 3"
}
]
},
{
"product": "Soft Starter ES V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:16:51",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7587",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Opcenter Execution Discrete",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Execution Foundation",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Execution Process",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Intelligence",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.3"
}
]
}
},
{
"product_name": "Opcenter Quality",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V11.3"
}
]
}
},
{
"product_name": "Opcenter RD\u0026L",
"version": {
"version_data": [
{
"version_value": "V8.0"
}
]
}
},
{
"product_name": "SIMATIC IT LMS",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.6"
}
]
}
},
{
"product_name": "SIMATIC IT Production Suite",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.0"
}
]
}
},
{
"product_name": "SIMATIC Notifier Server for Windows",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS neo",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0 SP1"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 5"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 2"
}
]
}
},
{
"product_name": "SIMOCODE ES V15.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 4"
}
]
}
},
{
"product_name": "SIMOCODE ES V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 1"
}
]
}
},
{
"product_name": "Soft Starter ES V15.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 3"
}
]
}
},
{
"product_name": "Soft Starter ES V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7587",
"datePublished": "2020-07-14T13:18:05",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.877Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7588 (GCVE-0-2020-7588)
Vulnerability from cvelistv5 – Published: 2020-07-14 13:18 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.
Severity ?
No CVSS data available.
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Opcenter Execution Discrete |
Affected:
All versions < V3.2
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.850Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V11.3"
}
]
},
{
"product": "Opcenter RD\u0026L",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V8.0"
}
]
},
{
"product": "SIMATIC IT LMS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.6"
}
]
},
{
"product": "SIMATIC IT Production Suite",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.0"
}
]
},
{
"product": "SIMATIC Notifier Server for Windows",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS neo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0 SP1"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMOCODE ES V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 4"
}
]
},
{
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
},
{
"product": "Soft Starter ES V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 3"
}
]
},
{
"product": "Soft Starter ES V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:16:56",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7588",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Opcenter Execution Discrete",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Execution Foundation",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Execution Process",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Intelligence",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.3"
}
]
}
},
{
"product_name": "Opcenter Quality",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V11.3"
}
]
}
},
{
"product_name": "Opcenter RD\u0026L",
"version": {
"version_data": [
{
"version_value": "V8.0"
}
]
}
},
{
"product_name": "SIMATIC IT LMS",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.6"
}
]
}
},
{
"product_name": "SIMATIC IT Production Suite",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.0"
}
]
}
},
{
"product_name": "SIMATIC Notifier Server for Windows",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS neo",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0 SP1"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 5"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 2"
}
]
}
},
{
"product_name": "SIMOCODE ES V15.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 4"
}
]
}
},
{
"product_name": "SIMOCODE ES V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 1"
}
]
}
},
{
"product_name": "Soft Starter ES V15.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 3"
}
]
}
},
{
"product_name": "Soft Starter ES V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20: Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7588",
"datePublished": "2020-07-14T13:18:05",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.850Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7581 (GCVE-0-2020-7581)
Vulnerability from cvelistv5 – Published: 2020-07-14 13:18 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.
Severity ?
No CVSS data available.
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Opcenter Execution Discrete |
Affected:
All versions < V3.2
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.617Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2"
}
]
},
{
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3"
}
]
},
{
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V11.3"
}
]
},
{
"product": "Opcenter RD\u0026L",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V8.0"
}
]
},
{
"product": "SIMATIC Notifier Server for Windows",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS neo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0 SP1"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMOCODE ES V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 4"
}
]
},
{
"product": "SIMOCODE ES V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
},
{
"product": "Soft Starter ES V15.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 3"
}
]
},
{
"product": "Soft Starter ES V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "CWE-428: Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:16:47",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7581",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Opcenter Execution Discrete",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Execution Foundation",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Execution Process",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2"
}
]
}
},
{
"product_name": "Opcenter Intelligence",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.3"
}
]
}
},
{
"product_name": "Opcenter Quality",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V11.3"
}
]
}
},
{
"product_name": "Opcenter RD\u0026L",
"version": {
"version_data": [
{
"version_value": "V8.0"
}
]
}
},
{
"product_name": "SIMATIC Notifier Server for Windows",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS neo",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0 SP1"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 5"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal) V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 2"
}
]
}
},
{
"product_name": "SIMOCODE ES V15.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 4"
}
]
}
},
{
"product_name": "SIMOCODE ES V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 1"
}
]
}
},
{
"product_name": "Soft Starter ES V15.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 3"
}
]
}
},
{
"product_name": "Soft Starter ES V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-428: Unquoted Search Path or Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7581",
"datePublished": "2020-07-14T13:18:05",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.617Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7586 (GCVE-0-2020-7586)
Vulnerability from cvelistv5 – Published: 2020-06-10 16:23 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.
Severity ?
No CVSS data available.
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 and earlier |
Affected:
All versions
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.798Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.2 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3"
}
]
},
{
"product": "SIMATIC PDM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.2"
}
]
},
{
"product": "SIMATIC STEP 7 V5.X",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.6 SP2 HF3"
}
]
},
{
"product": "SINAMICS STARTER (containing STEP 7 OEM version)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.4 HF2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T20:42:20",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7586",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.2 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.0 SP3"
}
]
}
},
{
"product_name": "SIMATIC PDM",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.2"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 V5.X",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.6 SP2 HF3"
}
]
}
},
{
"product_name": "SINAMICS STARTER (containing STEP 7 OEM version)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.4 HF2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7586",
"datePublished": "2020-06-10T16:23:52",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.798Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7585 (GCVE-0-2020-7585)
Vulnerability from cvelistv5 – Published: 2020-06-10 16:23 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.
Severity ?
No CVSS data available.
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC PCS 7 V8.2 and earlier |
Affected:
All versions
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.945Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.2 and earlier",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP3"
}
]
},
{
"product": "SIMATIC PDM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.2"
}
]
},
{
"product": "SIMATIC STEP 7 V5.X",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.6 SP2 HF3"
}
]
},
{
"product": "SINAMICS STARTER (containing STEP 7 OEM version)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.4 HF2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427: Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T20:42:20",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7585",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.2 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.0 SP3"
}
]
}
},
{
"product_name": "SIMATIC PDM",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.2"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 V5.X",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.6 SP2 HF3"
}
]
}
},
{
"product_name": "SINAMICS STARTER (containing STEP 7 OEM version)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.4 HF2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427: Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7585",
"datePublished": "2020-06-10T16:23:39",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.945Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7580 (GCVE-0-2020-7580)
Vulnerability from cvelistv5 – Published: 2020-06-10 00:00 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
Severity ?
No CVSS data available.
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Automation Tool |
Affected:
All versions < V4 SP2
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.492Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC Automation Tool",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4 SP2"
}
]
},
{
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 14"
}
]
},
{
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC NET PC Software V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Upd3"
}
]
},
{
"product": "SIMATIC PCS neo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0 SP1"
}
]
},
{
"product": "SIMATIC ProSave",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.8"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V13",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2 Update 4"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 10"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC STEP 7 V5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.6 SP2 HF3"
}
]
},
{
"product": "SIMATIC WinCC OA V3.16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.16 P018"
}
]
},
{
"product": "SIMATIC WinCC OA V3.17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.17 P003"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V13",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2 Update 4"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 10"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 14"
}
]
},
{
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP1 Update 3"
}
]
},
{
"product": "SINAMICS STARTER",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.4 HF2"
}
]
},
{
"product": "SINAMICS Startdrive",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V16 Update 3"
}
]
},
{
"product": "SINEC NMS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0 SP2"
}
]
},
{
"product": "SINEMA Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP3"
}
]
},
{
"product": "SINUMERIK ONE virtual",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V6.14"
}
]
},
{
"product": "SINUMERIK Operate",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V6.14"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "CWE-428: Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-13T00:00:00",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7580",
"datePublished": "2020-06-10T00:00:00",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10929 (GCVE-0-2019-10929)
Vulnerability from cvelistv5 – Published: 2019-08-13 18:55 – Updated: 2024-08-04 22:40
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.
Severity ?
No CVSS data available.
CWE
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC CP 1626 |
Affected:
All versions
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.230Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V20.8"
}
]
},
{
"product": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 14"
}
]
},
{
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0"
}
]
},
{
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.8.1"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V20.8"
}
]
},
{
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC OA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.16 P013"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:16:07",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC CP 1626",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1 Update 14"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V15",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.4.0"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.8.1"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC S7-PLCSIM Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC OA",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.16 P013"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10929",
"datePublished": "2019-08-13T18:55:57",
"dateReserved": "2019-04-08T00:00:00",
"dateUpdated": "2024-08-04T22:40:15.230Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-7165 (GCVE-0-2016-7165)
Vulnerability from cvelistv5 – Published: 2016-11-15 19:00 – Updated: 2024-08-06 01:50
VLAI?
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T01:50:47.526Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"name": "94158",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/94158"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2016-11-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-06-14T20:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"name": "94158",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/94158"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2016-7165",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
},
{
"name": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html",
"refsource": "MISC",
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"name": "94158",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/94158"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2016-7165",
"datePublished": "2016-11-15T19:00:00",
"dateReserved": "2016-09-08T00:00:00",
"dateUpdated": "2024-08-06T01:50:47.526Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-7959 (GCVE-0-2016-7959)
Vulnerability from cvelistv5 – Published: 2016-10-13 10:00 – Updated: 2024-08-06 02:13
VLAI?
Summary
Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T02:13:21.506Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03"
},
{
"name": "93551",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/93551"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2016-10-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-12-20T21:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03"
},
{
"name": "93551",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/93551"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2016-7959",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03"
},
{
"name": "93551",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/93551"
},
{
"name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2016-7959",
"datePublished": "2016-10-13T10:00:00",
"dateReserved": "2016-09-09T00:00:00",
"dateUpdated": "2024-08-06T02:13:21.506Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-7960 (GCVE-0-2016-7960)
Vulnerability from cvelistv5 – Published: 2016-10-13 10:00 – Updated: 2024-08-06 02:13
VLAI?
Summary
Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T02:13:21.400Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03"
},
{
"name": "93551",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/93551"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2016-10-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2016-12-20T21:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03"
},
{
"name": "93551",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/93551"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2016-7960",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03"
},
{
"name": "93551",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/93551"
},
{
"name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2016-7960",
"datePublished": "2016-10-13T10:00:00",
"dateReserved": "2016-09-09T00:00:00",
"dateUpdated": "2024-08-06T02:13:21.400Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-1601 (GCVE-0-2015-1601)
Vulnerability from cvelistv5 – Published: 2015-04-06 01:00 – Updated: 2024-08-06 04:47
VLAI?
Summary
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T04:47:17.322Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "72691",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/72691"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-02-17T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T14:06:07",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "72691",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/72691"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-1601",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "72691",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/72691"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-1601",
"datePublished": "2015-04-06T01:00:00",
"dateReserved": "2015-02-13T00:00:00",
"dateUpdated": "2024-08-06T04:47:17.322Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-1602 (GCVE-0-2015-1602)
Vulnerability from cvelistv5 – Published: 2015-04-06 01:00 – Updated: 2024-08-06 04:47
VLAI?
Summary
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T04:47:17.344Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-02-17T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2015-04-06T01:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-1602",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-1602",
"datePublished": "2015-04-06T01:00:00",
"dateReserved": "2015-02-13T00:00:00",
"dateUpdated": "2024-08-06T04:47:17.344Z",
"state": "PUBLISHED"
},