Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for sicam_a8000_cp-802x_firmware by siemens

    CVE-2018-13798 (GCVE-0-2018-13798)

    Vulnerability from nvd – Published: 2019-03-21 18:48 – Updated: 2024-08-05 09:14
    VLAI
    Summary
    A vulnerability has been identified in SICAM A8000 CP-8000 (All versions < V14), SICAM A8000 CP-802X (All versions < V14), SICAM A8000 CP-8050 (All versions < V2.00). Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the web server. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/TCP or 443/TCP. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the web server. A system reboot is required to recover the web service of the device. At the time of advisory update, exploit code for this security vulnerability is public.
    Severity
    No CVSS data available.
    CWE
    • Other
    Assigner
    References
    Impacted products
    Date Public
    2019-01-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:14:47.237Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-579309.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SICAM A8000 CP-8000, SICAM A8000 CP-802X, SICAM A8000 CP-8050",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "SICAM A8000 CP-8000 : All versions \u003c V14"
                }
              ]
            },
            {
              "product": "SICAM A8000 CP-802X",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "SICAM A8000 CP-802X : All versions \u003c V14"
                }
              ]
            },
            {
              "product": "SICAM A8000 CP-8050",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V2.00"
                }
              ]
            }
          ],
          "datePublic": "2019-01-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SICAM A8000 CP-8000 (All versions \u003c V14), SICAM A8000 CP-802X (All versions \u003c V14), SICAM A8000 CP-8050 (All versions \u003c V2.00). Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the web server. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/TCP or 443/TCP. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the web server. A system reboot is required to recover the web service of the device. At the time of advisory update, exploit code for this security vulnerability is public."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Other",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-03-21T18:48:48.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-579309.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2018-13798",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SICAM A8000 CP-8000, SICAM A8000 CP-802X, SICAM A8000 CP-8050",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SICAM A8000 CP-8000 : All versions \u003c V14"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens AG"
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SICAM A8000 CP-802X",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SICAM A8000 CP-802X : All versions \u003c V14"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens AG"
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SICAM A8000 CP-8050",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V2.00"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens AG"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SICAM A8000 CP-8000 (All versions \u003c V14), SICAM A8000 CP-802X (All versions \u003c V14), SICAM A8000 CP-8050 (All versions \u003c V2.00). Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the web server. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/TCP or 443/TCP. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the web server. A system reboot is required to recover the web service of the device. At the time of advisory update, exploit code for this security vulnerability is public."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Other"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-579309.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-579309.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2018-13798",
        "datePublished": "2019-03-21T18:48:48.000Z",
        "dateReserved": "2018-07-10T00:00:00.000Z",
        "dateUpdated": "2024-08-05T09:14:47.237Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-13798 (GCVE-0-2018-13798)

    Vulnerability from cvelistv5 – Published: 2019-03-21 18:48 – Updated: 2024-08-05 09:14
    VLAI
    Summary
    A vulnerability has been identified in SICAM A8000 CP-8000 (All versions < V14), SICAM A8000 CP-802X (All versions < V14), SICAM A8000 CP-8050 (All versions < V2.00). Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the web server. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/TCP or 443/TCP. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the web server. A system reboot is required to recover the web service of the device. At the time of advisory update, exploit code for this security vulnerability is public.
    Severity
    No CVSS data available.
    CWE
    • Other
    Assigner
    References
    Impacted products
    Date Public
    2019-01-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:14:47.237Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-579309.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SICAM A8000 CP-8000, SICAM A8000 CP-802X, SICAM A8000 CP-8050",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "SICAM A8000 CP-8000 : All versions \u003c V14"
                }
              ]
            },
            {
              "product": "SICAM A8000 CP-802X",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "SICAM A8000 CP-802X : All versions \u003c V14"
                }
              ]
            },
            {
              "product": "SICAM A8000 CP-8050",
              "vendor": "Siemens AG",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V2.00"
                }
              ]
            }
          ],
          "datePublic": "2019-01-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SICAM A8000 CP-8000 (All versions \u003c V14), SICAM A8000 CP-802X (All versions \u003c V14), SICAM A8000 CP-8050 (All versions \u003c V2.00). Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the web server. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/TCP or 443/TCP. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the web server. A system reboot is required to recover the web service of the device. At the time of advisory update, exploit code for this security vulnerability is public."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Other",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-03-21T18:48:48.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-579309.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2018-13798",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SICAM A8000 CP-8000, SICAM A8000 CP-802X, SICAM A8000 CP-8050",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SICAM A8000 CP-8000 : All versions \u003c V14"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens AG"
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SICAM A8000 CP-802X",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "SICAM A8000 CP-802X : All versions \u003c V14"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens AG"
                  },
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SICAM A8000 CP-8050",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V2.00"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens AG"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in SICAM A8000 CP-8000 (All versions \u003c V14), SICAM A8000 CP-802X (All versions \u003c V14), SICAM A8000 CP-8050 (All versions \u003c V2.00). Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the web server. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/TCP or 443/TCP. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the web server. A system reboot is required to recover the web service of the device. At the time of advisory update, exploit code for this security vulnerability is public."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Other"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-579309.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-579309.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2018-13798",
        "datePublished": "2019-03-21T18:48:48.000Z",
        "dateReserved": "2018-07-10T00:00:00.000Z",
        "dateUpdated": "2024-08-05T09:14:47.237Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }