Search

Find a vulnerability

Search criteria

    42 vulnerabilities found for sge-plc1000_firmware by circutor

    FKIE_CVE-2025-11784

    Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2026-09-26 00:10
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cve-coordination@incibe.es",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027ShowMeterDatabase()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u0027meter\u0027 parameter."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de desbordamiento de b\u00fafer basado en pila en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. En la funci\u00f3n \u0027ShowMeterDatabase()\u0027, hay una entrada de usuario ilimitada que se copia a un b\u00fafer de tama\u00f1o fijo a trav\u00e9s de \u0027sprintf()\u0027. La funci\u00f3n \u0027GetParameter(meter)\u0027 recupera la entrada del usuario, que se incorpora directamente a un b\u00fafer sin validaci\u00f3n de tama\u00f1o. Un atacante puede proporcionar una entrada excesivamente grande para el par\u00e1metro \u0027meter\u0027."
        }
      ],
      "id": "CVE-2025-11784",
      "lastModified": "2026-09-26T00:10:00.127",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "ADJACENT",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.5,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "HIGH",
              "subConfidentialityImpact": "HIGH",
              "subIntegrityImpact": "LOW",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "LOW",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-11784",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-12-02T13:59:23.859069Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-12-02T13:15:49.977",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-11786

    Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2026-09-26 00:10
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'SetUserPassword()' function, the 'newPassword' parameter is directly embedded in a shell command string using 'sprintf()' without any sanitisation or validation, and then executed using 'system()'. This allows an attacker to inject arbitrary shell commands that will be executed with the same privileges as the application.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cve-coordination@incibe.es",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027SetUserPassword()\u0027 function, the \u0027newPassword\u0027 parameter is directly embedded in a shell command string using \u0027sprintf()\u0027 without any sanitisation or validation, and then executed using \u0027system()\u0027. This allows an attacker to inject arbitrary shell commands that will be executed with the same privileges as the application."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de desbordamiento de b\u00fafer basado en pila en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. En la funci\u00f3n \u0027SetUserPassword()\u0027, el par\u00e1metro \u0027newPassword\u0027 se incrusta directamente en una cadena de comando de shell usando \u0027sprintf()\u0027 sin ninguna sanitizaci\u00f3n o validaci\u00f3n, y luego se ejecuta usando \u0027system()\u0027. Esto permite a un atacante inyectar comandos de shell arbitrarios que se ejecutar\u00e1n con los mismos privilegios que la aplicaci\u00f3n."
        }
      ],
      "id": "CVE-2025-11786",
      "lastModified": "2026-09-26T00:10:00.127",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "ADJACENT",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.5,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "HIGH",
              "subConfidentialityImpact": "HIGH",
              "subIntegrityImpact": "LOW",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "LOW",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-11786",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-12-02T13:36:34.960174Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-12-02T13:15:50.493",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-11782

    Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2026-09-26 00:10
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'ShowDownload()' function uses “sprintf()” to format a string that includes the user-controlled input of 'GetParameter(meter)' in the fixed-size buffer 'acStack_4c' (64 bytes) without checking the length. An attacker can provide an excessively long value for the 'meter' parameter that exceeds the 64-byte buffer size.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cve-coordination@incibe.es",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027ShowDownload()\u0027 function uses \u201csprintf()\u201d to format a string that includes the user-controlled input of \u0027GetParameter(meter)\u0027 in the fixed-size buffer \u0027acStack_4c\u0027 (64 bytes) without checking the length. An attacker can provide an excessively long value for the \u0027meter\u0027 parameter that exceeds the 64-byte buffer size."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de desbordamiento de b\u00fafer basado en pila en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. La funci\u00f3n \u0027ShowDownload()\u0027 utiliza \u201csprintf()\u201d para formatear una cadena que incluye la entrada controlada por el usuario de \u0027GetParameter(meter)\u0027 en el b\u00fafer de tama\u00f1o fijo \u0027acStack_4c\u0027 (64 bytes) sin verificar la longitud. Un atacante puede proporcionar un valor excesivamente largo para el par\u00e1metro \u0027meter\u0027 que excede el tama\u00f1o del b\u00fafer de 64 bytes."
        }
      ],
      "id": "CVE-2025-11782",
      "lastModified": "2026-09-26T00:10:00.127",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "ADJACENT",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.5,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "HIGH",
              "subConfidentialityImpact": "HIGH",
              "subIntegrityImpact": "LOW",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "LOW",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-11782",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-12-02T14:37:42.495493Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-12-02T13:15:49.420",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-11781

    Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2026-09-26 00:10
    Summary
    Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create valid firmware update packages. This bypasses all intended access controls and grants full administrative privileges.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cve-coordination@incibe.es",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create valid firmware update packages. This bypasses all intended access controls and grants full administrative privileges."
        },
        {
          "lang": "es",
          "value": "Uso de claves criptogr\u00e1ficas codificadas de forma r\u00edgida en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. El firmware afectado contiene una clave de autenticaci\u00f3n est\u00e1tica codificada de forma r\u00edgida. Un atacante con acceso local al dispositivo puede extraer esta clave (p. ej., analizando la imagen del firmware o un volcado de memoria) y crear paquetes de actualizaci\u00f3n de firmware v\u00e1lidos. Esto elude todos los controles de acceso previstos y otorga privilegios administrativos completos."
        }
      ],
      "id": "CVE-2025-11781",
      "lastModified": "2026-09-26T00:10:00.127",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "LOCAL",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.6,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-11781",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-12-02T13:34:55.937584Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-12-02T13:15:49.140",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-321"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-11783

    Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2026-09-26 00:10
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The vulnerability is found in the 'AddEvent()' function when copying the user-controlled username input to a fixed-size buffer (48 bytes) without boundary checking. This can lead to memory corruption, resulting in possible remote code execution.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cve-coordination@incibe.es",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The vulnerability is found in the \u0027AddEvent()\u0027 function when copying the user-controlled username input to a fixed-size buffer (48 bytes) without boundary checking. This can lead to memory corruption, resulting in possible remote code execution."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de desbordamiento de b\u00fafer basado en pila en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. La vulnerabilidad se encuentra en la funci\u00f3n \u0027AddEvent()\u0027 al copiar la entrada de nombre de usuario controlada por el usuario a un b\u00fafer de tama\u00f1o fijo (48 bytes) sin verificaci\u00f3n de l\u00edmites. Esto puede llevar a corrupci\u00f3n de memoria, resultando en una posible ejecuci\u00f3n remota de c\u00f3digo."
        }
      ],
      "id": "CVE-2025-11783",
      "lastModified": "2026-09-26T00:10:00.127",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "ADJACENT",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.5,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "HIGH",
              "subConfidentialityImpact": "HIGH",
              "subIntegrityImpact": "LOW",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "LOW",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-11783",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-12-02T14:00:05.778352Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-12-02T13:15:49.720",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-11779

    Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2026-09-26 00:10
    Summary
    Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The 'SetLan' function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes to the 'index.cgi' web application. The parameters are not being sanitised, which could lead to command injection.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cve-coordination@incibe.es",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027SetLan\u0027 function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes to the \u0027index.cgi\u0027 web application. The parameters are not being sanitised, which could lead to command injection."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de desbordamiento de b\u00fafer basado en pila en CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. La funci\u00f3n \u0027SetLan\u0027 se invoca cuando se aplica una nueva configuraci\u00f3n. Esta nueva funci\u00f3n de configuraci\u00f3n se activa mediante una solicitud web de gesti\u00f3n, que puede ser invocada por un usuario al realizar cambios en la aplicaci\u00f3n web \u0027index.cgi\u0027. Los par\u00e1metros no est\u00e1n siendo saneados, lo que podr\u00eda conducir a una inyecci\u00f3n de comandos."
        }
      ],
      "id": "CVE-2025-11779",
      "lastModified": "2026-09-26T00:10:00.127",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "ADJACENT",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 9.4,
              "baseSeverity": "CRITICAL",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "HIGH",
              "subConfidentialityImpact": "HIGH",
              "subIntegrityImpact": "HIGH",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-11779",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-12-02T13:44:18.885863Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-12-02T13:15:48.583",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-11788

    Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2026-09-26 00:10
    Summary
    Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowSupervisorParameters()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cve-coordination@incibe.es",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027ShowSupervisorParameters()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u0027meter\u0027 parameter."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de desbordamiento de b\u00fafer basado en mont\u00edculo en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. En la funci\u00f3n \u0027ShowSupervisorParameters()\u0027, hay una entrada de usuario ilimitada que se copia a un b\u00fafer de tama\u00f1o fijo a trav\u00e9s de \u0027sprintf()\u0027. La funci\u00f3n \u0027GetParameter(meter)\u0027 recupera la entrada del usuario, que se incorpora directamente a un b\u00fafer sin validaci\u00f3n de tama\u00f1o. Un atacante puede proporcionar una entrada excesivamente grande para el par\u00e1metro \u0027meter\u0027."
        }
      ],
      "id": "CVE-2025-11788",
      "lastModified": "2026-09-26T00:10:00.127",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.5,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "HIGH",
              "subConfidentialityImpact": "HIGH",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:H/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "NONE",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-11788",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-12-02T13:30:50.053898Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-12-02T13:15:51.027",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-122"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-11787

    Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2026-09-26 00:10
    Summary
    Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the 'GetDNS()', 'CheckPing()' and 'TraceRoute()' functions.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cve-coordination@incibe.es",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the \u0027GetDNS()\u0027, \u0027CheckPing()\u0027 and \u0027TraceRoute()\u0027 functions."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de inyecci\u00f3n de comandos en el sistema operativo en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 a trav\u00e9s de las funciones \u0027GetDNS()\u0027, \u0027CheckPing()\u0027 y \u0027TraceRoute()\u0027."
        }
      ],
      "id": "CVE-2025-11787",
      "lastModified": "2026-09-26T00:10:00.127",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.5,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "ACTIVE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-11787",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-12-02T13:31:39.174867Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-12-02T13:15:50.730",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-78"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-11789

    Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2026-09-25 23:10
    Summary
    Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'DownloadFile' function converts a parameter to an integer using 'atoi()' and then uses it as an index in the 'FilesDownload' array with '(&FilesDownload)[iVar2]'. If the parameter is too large, it will access memory beyond the limits.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cve-coordination@incibe.es",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027DownloadFile\u0027 function converts a parameter to an integer using \u0027atoi()\u0027 and then uses it as an index in the \u0027FilesDownload\u0027 array with \u0027(\u0026FilesDownload)[iVar2]\u0027. If the parameter is too large, it will access memory beyond the limits."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de lectura fuera de l\u00edmites en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. La funci\u00f3n \u0027DownloadFile\u0027 convierte un par\u00e1metro a un entero usando \u0027atoi()\u0027 y luego lo usa como un \u00edndice en el array \u0027FilesDownload\u0027 con \u0027(\u0026FilesDownload)[iVar2]\u0027. Si el par\u00e1metro es demasiado grande, acceder\u00e1 a memoria m\u00e1s all\u00e1 de los l\u00edmites."
        }
      ],
      "id": "CVE-2025-11789",
      "lastModified": "2026-09-25T23:10:00.463",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 7.1,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "NONE",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "NONE",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-11789",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-12-02T13:27:07.563850Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-12-02T13:15:52.897",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-11785

    Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2026-06-17 08:31
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cve-coordination@incibe.es",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027ShowMeterPasswords()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u0027meter\u0027 parameter."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de desbordamiento de b\u00fafer basado en pila en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. En la funci\u00f3n \u0027ShowMeterPasswords()\u0027, existe una entrada de usuario ilimitada que se copia a un b\u00fafer de tama\u00f1o fijo a trav\u00e9s de \u0027sprintf()\u0027. La funci\u00f3n \u0027GetParameter(meter)\u0027 recupera la entrada del usuario, la cual se incorpora directamente en un b\u00fafer sin validaci\u00f3n de tama\u00f1o. Un atacante puede proporcionar una entrada excesivamente grande para el par\u00e1metro \u0027meter\u0027."
        }
      ],
      "id": "CVE-2025-11785",
      "lastModified": "2026-06-17T08:31:10.257",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "ADJACENT",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.5,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "HIGH",
              "subConfidentialityImpact": "HIGH",
              "subIntegrityImpact": "LOW",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "LOW",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-11785",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-12-02T13:37:28.560729Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-12-02T13:15:50.223",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-11780

    Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2026-06-17 08:31
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the “meter” parameter.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "203C8B5E-582A-4680-B324-B9092F01462B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cve-coordination@incibe.es",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027showMeterReport()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u201cmeter\u201d parameter."
        },
        {
          "lang": "es",
          "value": "Vulnerabilidad de desbordamiento de b\u00fafer basado en pila en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. En la funci\u00f3n \u0027showMeterReport()\u0027, existe una entrada de usuario ilimitada que se copia a un b\u00fafer de tama\u00f1o fijo a trav\u00e9s de \u0027sprintf()\u0027. La funci\u00f3n \u0027GetParameter(meter)\u0027 recupera la entrada del usuario, la cual se incorpora directamente a un b\u00fafer sin validaci\u00f3n de tama\u00f1o. Un atacante puede proporcionar una entrada excesivamente grande para el par\u00e1metro \u0027meter\u0027."
        }
      ],
      "id": "CVE-2025-11780",
      "lastModified": "2026-06-17T08:31:09.553",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.7,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-11780",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-12-02T13:42:40.633028Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-12-02T13:15:48.887",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-120"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-11778

    Vulnerability from fkie_nvd - Published: 2025-12-02 13:15 - Updated: 2026-06-17 08:31
    Summary
    Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely exploit memory corruption through the 'read_packet()' function of the TACACSPLUS implementation.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:0.9.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7E3370BA-F0CD-42E3-BAAE-B2FE3E6D413B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc50_firmware:0.9.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5FE73FE9-C7E7-468D-A73B-0B276A6FE94E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "447D1571-5329-422D-8E31-F4964E412FC3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cve-coordination@incibe.es",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely exploit memory corruption through the \u0027read_packet()\u0027 function of the TACACSPLUS implementation."
        },
        {
          "lang": "es",
          "value": "Desbordamiento de b\u00fafer basado en pila en Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. Esta vulnerabilidad permite a un atacante explotar remotamente la corrupci\u00f3n de memoria a trav\u00e9s de la funci\u00f3n \u0027read_packet()\u0027 de la implementaci\u00f3n de TACACSPLUS."
        }
      ],
      "id": "CVE-2025-11778",
      "lastModified": "2026-06-17T08:31:09.280",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 10.0,
              "baseSeverity": "CRITICAL",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "HIGH",
              "subConfidentialityImpact": "HIGH",
              "subIntegrityImpact": "HIGH",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-11778",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-12-02T13:47:14.665410Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-12-02T13:15:47.400",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-122"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2021-33842

    Vulnerability from fkie_nvd - Published: 2021-06-09 12:15 - Updated: 2026-06-17 03:55
    Summary
    Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located.
    Impacted products
    Vendor Product Version
    circutor sge-plc1000_firmware 0.9.2b
    circutor sge-plc1000 -

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "SGE-PLC1000",
              "vendor": "Circutor",
              "versions": [
                {
                  "status": "affected",
                  "version": "0.9.2b"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:0.9.2b:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5D6B02E0-DE36-45F5-AD3D-908E30548661",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad de Autenticaci\u00f3n Inapropiada en el par\u00e1metro cookies de Circutor SGE-PLC1000 versi\u00f3n del firmware 0.9.2b, permite a un atacante llevar a cabo operaciones como un usuario autenticado.\u0026#xa0;Para explotar esta vulnerabilidad, el atacante debe estar dentro de la red donde se encuentra el dispositivo afectado"
        }
      ],
      "id": "CVE-2021-33842",
      "lastModified": "2026-06-17T03:55:17.827",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "ADJACENT_NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 7.7,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 5.1,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-06-09T12:15:07.957",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-565"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-565"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-33841

    Vulnerability from fkie_nvd - Published: 2021-06-09 12:15 - Updated: 2026-06-17 03:55
    Summary
    SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges.
    Impacted products
    Vendor Product Version
    circutor sge-plc1000_firmware 0.9.2b
    circutor sge-plc1000 -

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "SGE-PLC1000",
              "vendor": "Circutor",
              "versions": [
                {
                  "status": "affected",
                  "version": "0.9.2b"
                }
              ]
            }
          ],
          "source": "cve-coordination@incibe.es"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:0.9.2b:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5D6B02E0-DE36-45F5-AD3D-908E30548661",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges."
        },
        {
          "lang": "es",
          "value": "Un dispositivo SGE-PLC1000, en su versi\u00f3n de firmware 0.9.2b, no maneja algunas petici\u00f3nes correctamente, permitiendo a un atacante remoto inyectar c\u00f3digo en el sistema operativo con m\u00e1ximos privilegios"
        }
      ],
      "id": "CVE-2021-33841",
      "lastModified": "2026-06-17T03:55:17.710",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 10.0,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 10.0,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.0,
            "source": "cve-coordination@incibe.es",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-06-09T12:15:07.893",
      "references": [
        {
          "source": "cve-coordination@incibe.es",
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-os-command-injection"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-os-command-injection"
        }
      ],
      "sourceIdentifier": "cve-coordination@incibe.es",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-78"
            }
          ],
          "source": "cve-coordination@incibe.es",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-78"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2025-11789 (GCVE-0-2025-11789)

    Vulnerability from nvd – Published: 2025-12-02 13:04 – Updated: 2025-12-02 13:27 Unsupported When Assigned
    VLAI
    Title
    Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'DownloadFile' function converts a parameter to an integer using 'atoi()' and then uses it as an index in the 'FilesDownload' array with '(&FilesDownload)[iVar2]'. If the parameter is too large, it will access memory beyond the limits.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:27 UTC
    CWE
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11789",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:27:07.563850Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:27:16.494Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027DownloadFile\u0027 function converts a parameter to an integer using \u0027atoi()\u0027 and then uses it as an index in the \u0027FilesDownload\u0027 array with \u0027(\u0026amp;FilesDownload)[iVar2]\u0027. If the parameter is too large, it will access memory beyond the limits."
                }
              ],
              "value": "Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027DownloadFile\u0027 function converts a parameter to an integer using \u0027atoi()\u0027 and then uses it as an index in the \u0027FilesDownload\u0027 array with \u0027(\u0026FilesDownload)[iVar2]\u0027. If the parameter is too large, it will access memory beyond the limits."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T13:04:38.363Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11789",
        "datePublished": "2025-12-02T13:04:38.363Z",
        "dateReserved": "2025-10-15T12:06:20.162Z",
        "dateUpdated": "2025-12-02T13:27:16.494Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11788 (GCVE-0-2025-11788)

    Vulnerability from nvd – Published: 2025-12-02 13:03 – Updated: 2025-12-02 13:31 Unsupported When Assigned
    VLAI
    Title
    Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowSupervisorParameters()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:30 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11788",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:30:50.053898Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:31:08.915Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027ShowSupervisorParameters()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u0027meter\u0027 parameter."
                }
              ],
              "value": "Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027ShowSupervisorParameters()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u0027meter\u0027 parameter."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:H/SI:N/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T13:03:32.925Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11788",
        "datePublished": "2025-12-02T13:03:32.925Z",
        "dateReserved": "2025-10-15T12:06:18.604Z",
        "dateUpdated": "2025-12-02T13:31:08.915Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11787 (GCVE-0-2025-11787)

    Vulnerability from nvd – Published: 2025-12-02 13:02 – Updated: 2025-12-02 13:31 Unsupported When Assigned
    VLAI
    Title
    Command injection vulnerability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the 'GetDNS()', 'CheckPing()' and 'TraceRoute()' functions.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:31 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11787",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:31:39.174867Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:31:49.784Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the \u0027GetDNS()\u0027, \u0027CheckPing()\u0027 and \u0027TraceRoute()\u0027 functions."
                }
              ],
              "value": "Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the \u0027GetDNS()\u0027, \u0027CheckPing()\u0027 and \u0027TraceRoute()\u0027 functions."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T13:02:40.055Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Command injection vulnerability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11787",
        "datePublished": "2025-12-02T13:02:40.055Z",
        "dateReserved": "2025-10-15T12:06:17.304Z",
        "dateUpdated": "2025-12-02T13:31:49.784Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11786 (GCVE-0-2025-11786)

    Vulnerability from nvd – Published: 2025-12-02 13:01 – Updated: 2025-12-02 13:36 Unsupported When Assigned
    VLAI
    Title
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'SetUserPassword()' function, the 'newPassword' parameter is directly embedded in a shell command string using 'sprintf()' without any sanitisation or validation, and then executed using 'system()'. This allows an attacker to inject arbitrary shell commands that will be executed with the same privileges as the application.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:36 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11786",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:36:34.960174Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:36:41.564Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027SetUserPassword()\u0027 function, the \u0027newPassword\u0027 parameter is directly embedded in a shell command string using \u0027sprintf()\u0027 without any sanitisation or validation, and then executed using \u0027system()\u0027. This allows an attacker to inject arbitrary shell commands that will be executed with the same privileges as the application."
                }
              ],
              "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027SetUserPassword()\u0027 function, the \u0027newPassword\u0027 parameter is directly embedded in a shell command string using \u0027sprintf()\u0027 without any sanitisation or validation, and then executed using \u0027system()\u0027. This allows an attacker to inject arbitrary shell commands that will be executed with the same privileges as the application."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T13:01:39.635Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11786",
        "datePublished": "2025-12-02T13:01:37.231Z",
        "dateReserved": "2025-10-15T12:06:16.258Z",
        "dateUpdated": "2025-12-02T13:36:41.564Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11785 (GCVE-0-2025-11785)

    Vulnerability from nvd – Published: 2025-12-02 13:01 – Updated: 2025-12-02 13:37 Unsupported When Assigned
    VLAI
    Title
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:37 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11785",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:37:28.560729Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:37:33.371Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027ShowMeterPasswords()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u0027meter\u0027 parameter."
                }
              ],
              "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027ShowMeterPasswords()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u0027meter\u0027 parameter."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T13:01:27.956Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11785",
        "datePublished": "2025-12-02T13:01:25.600Z",
        "dateReserved": "2025-10-15T12:06:15.214Z",
        "dateUpdated": "2025-12-02T13:37:33.371Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11784 (GCVE-0-2025-11784)

    Vulnerability from nvd – Published: 2025-12-02 13:01 – Updated: 2025-12-02 13:59 Unsupported When Assigned
    VLAI
    Title
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:59 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11784",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:59:23.859069Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:59:31.509Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027ShowMeterDatabase()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u0027meter\u0027 parameter."
                }
              ],
              "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027ShowMeterDatabase()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u0027meter\u0027 parameter."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T13:01:15.908Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11784",
        "datePublished": "2025-12-02T13:01:15.908Z",
        "dateReserved": "2025-10-15T12:06:14.111Z",
        "dateUpdated": "2025-12-02T13:59:31.509Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11783 (GCVE-0-2025-11783)

    Vulnerability from nvd – Published: 2025-12-02 13:01 – Updated: 2025-12-02 14:00 Unsupported When Assigned
    VLAI
    Title
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The vulnerability is found in the 'AddEvent()' function when copying the user-controlled username input to a fixed-size buffer (48 bytes) without boundary checking. This can lead to memory corruption, resulting in possible remote code execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 14:00 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11783",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T14:00:05.778352Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T14:00:14.603Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The vulnerability is found in the \u0027AddEvent()\u0027 function when copying the user-controlled username input to a fixed-size buffer (48 bytes) without boundary checking. This can lead to memory corruption, resulting in possible remote code execution."
                }
              ],
              "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The vulnerability is found in the \u0027AddEvent()\u0027 function when copying the user-controlled username input to a fixed-size buffer (48 bytes) without boundary checking. This can lead to memory corruption, resulting in possible remote code execution."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T13:01:04.236Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11783",
        "datePublished": "2025-12-02T13:01:04.236Z",
        "dateReserved": "2025-10-15T12:06:12.926Z",
        "dateUpdated": "2025-12-02T14:00:14.603Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11782 (GCVE-0-2025-11782)

    Vulnerability from nvd – Published: 2025-12-02 13:00 – Updated: 2025-12-02 14:37 Unsupported When Assigned
    VLAI
    Title
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'ShowDownload()' function uses “sprintf()” to format a string that includes the user-controlled input of 'GetParameter(meter)' in the fixed-size buffer 'acStack_4c' (64 bytes) without checking the length. An attacker can provide an excessively long value for the 'meter' parameter that exceeds the 64-byte buffer size.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 14:37 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11782",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T14:37:42.495493Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T14:37:50.963Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027ShowDownload()\u0027 function uses \u201csprintf()\u201d to format a string that includes the user-controlled input of \u0027GetParameter(meter)\u0027 in the fixed-size buffer \u0027acStack_4c\u0027 (64 bytes) without checking the length. An attacker can provide an excessively long value for the \u0027meter\u0027 parameter that exceeds the 64-byte buffer size."
                }
              ],
              "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027ShowDownload()\u0027 function uses \u201csprintf()\u201d to format a string that includes the user-controlled input of \u0027GetParameter(meter)\u0027 in the fixed-size buffer \u0027acStack_4c\u0027 (64 bytes) without checking the length. An attacker can provide an excessively long value for the \u0027meter\u0027 parameter that exceeds the 64-byte buffer size."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T13:00:48.947Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11782",
        "datePublished": "2025-12-02T13:00:48.947Z",
        "dateReserved": "2025-10-15T12:06:11.744Z",
        "dateUpdated": "2025-12-02T14:37:50.963Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11781 (GCVE-0-2025-11781)

    Vulnerability from nvd – Published: 2025-12-02 12:59 – Updated: 2025-12-02 13:35 Unsupported When Assigned
    VLAI
    Title
    Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create valid firmware update packages. This bypasses all intended access controls and grants full administrative privileges.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:34 UTC
    CWE
    • CWE-321 - Use of Hard-coded Cryptographic Key
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11781",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:34:55.937584Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:35:07.164Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create valid firmware update packages. This bypasses all intended access controls and grants full administrative privileges."
                }
              ],
              "value": "Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create valid firmware update packages. This bypasses all intended access controls and grants full administrative privileges."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "CWE-321: Use of Hard-coded Cryptographic Key",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T12:59:46.925Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11781",
        "datePublished": "2025-12-02T12:59:46.925Z",
        "dateReserved": "2025-10-15T12:06:10.689Z",
        "dateUpdated": "2025-12-02T13:35:07.164Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11780 (GCVE-0-2025-11780)

    Vulnerability from nvd – Published: 2025-12-02 12:58 – Updated: 2025-12-02 13:43 Unsupported When Assigned
    VLAI
    Title
    Stack-based buffer overflow vulnreability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the “meter” parameter.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:42 UTC
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11780",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:42:40.633028Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:43:28.808Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027showMeterReport()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u201cmeter\u201d parameter."
                }
              ],
              "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027showMeterReport()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u201cmeter\u201d parameter."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T12:58:35.719Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Stack-based buffer overflow vulnreability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11780",
        "datePublished": "2025-12-02T12:58:35.719Z",
        "dateReserved": "2025-10-15T12:06:09.589Z",
        "dateUpdated": "2025-12-02T13:43:28.808Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11779 (GCVE-0-2025-11779)

    Vulnerability from nvd – Published: 2025-12-02 12:57 – Updated: 2025-12-02 13:44 Unsupported When Assigned
    VLAI
    Title
    Stack-based buffer overflow vulnreability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The 'SetLan' function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes to the 'index.cgi' web application. The parameters are not being sanitised, which could lead to command injection.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:44 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11779",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:44:18.885863Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:44:57.270Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027SetLan\u0027 function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes to the \u0027index.cgi\u0027 web application. The parameters are not being sanitised, which could lead to command injection."
                }
              ],
              "value": "Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027SetLan\u0027 function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes to the \u0027index.cgi\u0027 web application. The parameters are not being sanitised, which could lead to command injection."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T12:57:46.050Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Stack-based buffer overflow vulnreability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11779",
        "datePublished": "2025-12-02T12:57:46.050Z",
        "dateReserved": "2025-10-15T12:06:08.399Z",
        "dateUpdated": "2025-12-02T13:44:57.270Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11778 (GCVE-0-2025-11778)

    Vulnerability from nvd – Published: 2025-12-02 12:56 – Updated: 2025-12-02 13:47 Unsupported When Assigned
    VLAI
    Title
    Stack-based buffer overflow vulnreability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely exploit memory corruption through the 'read_packet()' function of the TACACSPLUS implementation.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:47 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11778",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:47:14.665410Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:47:44.947Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely exploit memory corruption through the \u0027read_packet()\u0027 function of the TACACSPLUS implementation."
                }
              ],
              "value": "Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely exploit memory corruption through the \u0027read_packet()\u0027 function of the TACACSPLUS implementation."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T12:56:38.092Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Stack-based buffer overflow vulnreability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11778",
        "datePublished": "2025-12-02T12:56:38.092Z",
        "dateReserved": "2025-10-15T12:06:07.138Z",
        "dateUpdated": "2025-12-02T13:47:44.947Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11789 (GCVE-0-2025-11789)

    Vulnerability from cvelistv5 – Published: 2025-12-02 13:04 – Updated: 2025-12-02 13:27 Unsupported When Assigned
    VLAI
    Title
    Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'DownloadFile' function converts a parameter to an integer using 'atoi()' and then uses it as an index in the 'FilesDownload' array with '(&FilesDownload)[iVar2]'. If the parameter is too large, it will access memory beyond the limits.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:27 UTC
    CWE
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11789",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:27:07.563850Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:27:16.494Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027DownloadFile\u0027 function converts a parameter to an integer using \u0027atoi()\u0027 and then uses it as an index in the \u0027FilesDownload\u0027 array with \u0027(\u0026amp;FilesDownload)[iVar2]\u0027. If the parameter is too large, it will access memory beyond the limits."
                }
              ],
              "value": "Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The \u0027DownloadFile\u0027 function converts a parameter to an integer using \u0027atoi()\u0027 and then uses it as an index in the \u0027FilesDownload\u0027 array with \u0027(\u0026FilesDownload)[iVar2]\u0027. If the parameter is too large, it will access memory beyond the limits."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T13:04:38.363Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11789",
        "datePublished": "2025-12-02T13:04:38.363Z",
        "dateReserved": "2025-10-15T12:06:20.162Z",
        "dateUpdated": "2025-12-02T13:27:16.494Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11788 (GCVE-0-2025-11788)

    Vulnerability from cvelistv5 – Published: 2025-12-02 13:03 – Updated: 2025-12-02 13:31 Unsupported When Assigned
    VLAI
    Title
    Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowSupervisorParameters()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:30 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11788",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:30:50.053898Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:31:08.915Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027ShowSupervisorParameters()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u0027meter\u0027 parameter."
                }
              ],
              "value": "Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027ShowSupervisorParameters()\u0027 function, there is an unlimited user input that is copied to a fixed-size buffer via \u0027sprintf()\u0027. The \u0027GetParameter(meter)\u0027 function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the \u0027meter\u0027 parameter."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:H/SI:N/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T13:03:32.925Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11788",
        "datePublished": "2025-12-02T13:03:32.925Z",
        "dateReserved": "2025-10-15T12:06:18.604Z",
        "dateUpdated": "2025-12-02T13:31:08.915Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11787 (GCVE-0-2025-11787)

    Vulnerability from cvelistv5 – Published: 2025-12-02 13:02 – Updated: 2025-12-02 13:31 Unsupported When Assigned
    VLAI
    Title
    Command injection vulnerability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the 'GetDNS()', 'CheckPing()' and 'TraceRoute()' functions.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:31 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11787",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:31:39.174867Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:31:49.784Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the \u0027GetDNS()\u0027, \u0027CheckPing()\u0027 and \u0027TraceRoute()\u0027 functions."
                }
              ],
              "value": "Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the \u0027GetDNS()\u0027, \u0027CheckPing()\u0027 and \u0027TraceRoute()\u0027 functions."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T13:02:40.055Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Command injection vulnerability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11787",
        "datePublished": "2025-12-02T13:02:40.055Z",
        "dateReserved": "2025-10-15T12:06:17.304Z",
        "dateUpdated": "2025-12-02T13:31:49.784Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-11786 (GCVE-0-2025-11786)

    Vulnerability from cvelistv5 – Published: 2025-12-02 13:01 – Updated: 2025-12-02 13:36 Unsupported When Assigned
    VLAI
    Title
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50
    Summary
    Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'SetUserPassword()' function, the 'newPassword' parameter is directly embedded in a shell command string using 'sprintf()' without any sanitisation or validation, and then executed using 'system()'. This allows an attacker to inject arbitrary shell commands that will be executed with the same privileges as the application.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-02 13:36 UTC
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    INCIBE CNA under the INCIBE root
    CNA scorecard B 85/100 over 188 records in the last 180 days details
    Impacted products
    Vendor Product Version
    SGE-PLC1000 SGE-PLC50 Circutor Affected: 9.0.2
        cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2025-10-28 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-11786",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-02T13:36:34.960174Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-02T13:36:41.564Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Circutor",
              "vendor": "SGE-PLC1000 SGE-PLC50",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.0.2"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:sge-plc1000_sge-plc50:circutor:9.0.2:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Gabriel Gonzalez and Sergio Ruiz"
            }
          ],
          "datePublic": "2025-10-28T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027SetUserPassword()\u0027 function, the \u0027newPassword\u0027 parameter is directly embedded in a shell command string using \u0027sprintf()\u0027 without any sanitisation or validation, and then executed using \u0027system()\u0027. This allows an attacker to inject arbitrary shell commands that will be executed with the same privileges as the application."
                }
              ],
              "value": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the \u0027SetUserPassword()\u0027 function, the \u0027newPassword\u0027 parameter is directly embedded in a shell command string using \u0027sprintf()\u0027 without any sanitisation or validation, and then executed using \u0027system()\u0027. This allows an attacker to inject arbitrary shell commands that will be executed with the same privileges as the application."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-02T13:01:39.635Z",
            "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
            "shortName": "INCIBE"
          },
          "references": [
            {
              "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
                }
              ],
              "value": "The SGE-PLC100 and SGE-PLC50 units were discontinued in 2015. They were replaced by the Compact DC, which in turn became obsolete in November 2024. The current equivalent product is the GEDE EDC. The oldest version currently installed is 1.0.14, as it was the first to be compatible with the existing tariff system, while the latest version of these units is 1.2.21. Circutor recommends not extending the useful life of the SGE-PLC100 and SGE-PLC50 concentrators without keeping them updated. For both the Compact DC units (which replaced the SGE series) and the current GEDE EDC, it is recommended to update to the latest available version (2.0.4) or, at a minimum, to 2.0.0. This approach not only mitigates the identified vulnerabilities, but also provides new functionalities derived from the evolution of DLMS, the PRIME standard, STG protocols and the REST API."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "unsupported-when-assigned"
          ],
          "title": "Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "assignerShortName": "INCIBE",
        "cveId": "CVE-2025-11786",
        "datePublished": "2025-12-02T13:01:37.231Z",
        "dateReserved": "2025-10-15T12:06:16.258Z",
        "dateUpdated": "2025-12-02T13:36:41.564Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }