Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for scalance_x300wg_firmware by siemens

    CVE-2021-25667 (GCVE-0-2021-25667)

    Vulnerability from nvd – Published: 2021-03-15 17:03 – Updated: 2026-06-02 19:24
    VLAI
    Summary
    A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:11:27.468Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-25667",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:24:14.973158Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:24:47.966Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RUGGEDCOM RM1224",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V4.3 and \u003c V6.4"
                }
              ]
            },
            {
              "product": "SCALANCE M-800",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V4.3 and \u003c V6.4"
                }
              ]
            },
            {
              "product": "SCALANCE S615",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V4.3 and \u003c V6.4"
                }
              ]
            },
            {
              "product": "SCALANCE SC-600 Family",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V2.0 and \u003c V2.1.3"
                }
              ]
            },
            {
              "product": "SCALANCE XB-200",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE XC-200",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE XF-200BA",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE XM400",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V6.2"
                }
              ]
            },
            {
              "product": "SCALANCE XP-200",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE XR-300WG",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE XR500",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V6.2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-25667",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "RUGGEDCOM RM1224",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V4.3 and \u003c V6.4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE M-800",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V4.3 and \u003c V6.4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S615",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V4.3 and \u003c V6.4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE SC-600 Family",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V2.0 and \u003c V2.1.3"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XB-200",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XC-200",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XF-200BA",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XM400",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V6.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XP-200",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XR-300WG",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XR500",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V6.2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121: Stack-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-25667",
        "datePublished": "2021-03-15T17:03:31.000Z",
        "dateReserved": "2021-01-21T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:24:47.966Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-25667 (GCVE-0-2021-25667)

    Vulnerability from cvelistv5 – Published: 2021-03-15 17:03 – Updated: 2026-06-02 19:24
    VLAI
    Summary
    A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:11:27.468Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-25667",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:24:14.973158Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:24:47.966Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "RUGGEDCOM RM1224",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V4.3 and \u003c V6.4"
                }
              ]
            },
            {
              "product": "SCALANCE M-800",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V4.3 and \u003c V6.4"
                }
              ]
            },
            {
              "product": "SCALANCE S615",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V4.3 and \u003c V6.4"
                }
              ]
            },
            {
              "product": "SCALANCE SC-600 Family",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003e= V2.0 and \u003c V2.1.3"
                }
              ]
            },
            {
              "product": "SCALANCE XB-200",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE XC-200",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE XF-200BA",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE XM400",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V6.2"
                }
              ]
            },
            {
              "product": "SCALANCE XP-200",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE XR-300WG",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V4.1"
                }
              ]
            },
            {
              "product": "SCALANCE XR500",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V6.2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-25667",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "RUGGEDCOM RM1224",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V4.3 and \u003c V6.4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE M-800",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V4.3 and \u003c V6.4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE S615",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V4.3 and \u003c V6.4"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE SC-600 Family",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003e= V2.0 and \u003c V2.1.3"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XB-200",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XC-200",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XF-200BA",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XM400",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V6.2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XP-200",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XR-300WG",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V4.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "SCALANCE XR500",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V6.2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121: Stack-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-25667",
        "datePublished": "2021-03-15T17:03:31.000Z",
        "dateReserved": "2021-01-21T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:24:47.966Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }