Search
Find a vulnerability
Search criteria
4 vulnerabilities found for scalance_w746-1 by siemens
CVE-2013-4652 (GCVE-0-2013-4652)
Vulnerability from nvd – Published: 2013-07-31 18:00 – Updated: 2024-09-16 22:26
VLAI
EPSS
VEX
Summary
Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| http://www.siemens.com/corporate-technology/pool/… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:27.124Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-07-31T18:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4652",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4652",
"datePublished": "2013-07-31T18:00:00.000Z",
"dateReserved": "2013-06-24T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:26:37.770Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-4651 (GCVE-0-2013-4651)
Vulnerability from nvd – Published: 2013-07-31 18:00 – Updated: 2024-09-17 03:32
VLAI
EPSS
VEX
Summary
Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| http://www.siemens.com/corporate-technology/pool/… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:26.502Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers\u0027 installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate\u0027s trust relationship."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-07-31T18:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4651",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers\u0027 installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate\u0027s trust relationship."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4651",
"datePublished": "2013-07-31T18:00:00.000Z",
"dateReserved": "2013-06-24T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:32:39.448Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-4651 (GCVE-0-2013-4651)
Vulnerability from cvelistv5 – Published: 2013-07-31 18:00 – Updated: 2024-09-17 03:32
VLAI
EPSS
VEX
Summary
Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| http://www.siemens.com/corporate-technology/pool/… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:26.502Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers\u0027 installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate\u0027s trust relationship."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-07-31T18:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4651",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers\u0027 installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate\u0027s trust relationship."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4651",
"datePublished": "2013-07-31T18:00:00.000Z",
"dateReserved": "2013-06-24T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:32:39.448Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-4652 (GCVE-0-2013-4652)
Vulnerability from cvelistv5 – Published: 2013-07-31 18:00 – Updated: 2024-09-16 22:26
VLAI
EPSS
VEX
Summary
Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| http://www.siemens.com/corporate-technology/pool/… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:27.124Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-07-31T18:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4652",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4652",
"datePublished": "2013-07-31T18:00:00.000Z",
"dateReserved": "2013-06-24T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:26:37.770Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}