Search
Find a vulnerability
Search criteria
60 vulnerabilities found for safety_sil2 by codesys
FKIE_CVE-2023-37559
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
},
{
"lang": "es",
"value": "Despu\u00e9s de una autenticaci\u00f3n exitosa como usuario en m\u00faltiples productos Codesys en m\u00faltiples versiones, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpAppForce lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda conducir a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37558"
}
],
"id": "CVE-2023-37559",
"lastModified": "2026-06-17T06:08:27.490",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37559",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:28.102576Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.977",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37558
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
},
{
"lang": "es",
"value": "Despu\u00e9s de una autenticaci\u00f3n exitosa como usuario en m\u00faltiples productos Codesys en m\u00faltiples versiones, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpAppForce lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda conducir a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37559"
}
],
"id": "CVE-2023-37558",
"lastModified": "2026-06-17T06:08:27.347",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37558",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:13.616622Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.890",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37557
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
},
{
"lang": "es",
"value": "Despu\u00e9s de una autenticaci\u00f3n exitosa como usuario en m\u00faltiples productos Codesys en m\u00faltiples versiones, solicitudes de comunicaci\u00f3n remota dise\u00f1adas espec\u00edficamente pueden hacer que el componente CmpAppBP sobrescriba un desbordamiento de b\u00fafer, lo que puede conducir a una condici\u00f3n de denegaci\u00f3n de servicio."
}
],
"id": "CVE-2023-37557",
"lastModified": "2026-06-17T06:08:27.190",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37557",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:48:56.664856Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.797",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-37556
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and CVE-2023-37555.\n\n"
},
{
"lang": "es",
"value": "En varias versiones de varios productos Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpAppBP lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda provocar una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 y CVE-2023-37555."
}
],
"id": "CVE-2023-37556",
"lastModified": "2026-06-17T06:08:27.037",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37556",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:03.697246Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.707",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37555
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and\u00a0CVE-2023-37556.\n\n"
},
{
"lang": "es",
"value": "En m\u00faltiples versiones de m\u00faltiples productos de Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, las solicitudes de comunicaci\u00f3n de red espec\u00edficas con contenido inconsistente pueden causar que el componente CmpAppBP lea internamente desde una direcci\u00f3n inv\u00e1lida, potencialmente llevando a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente de CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 y CVE-2023-37556."
}
],
"id": "CVE-2023-37555",
"lastModified": "2026-06-17T06:08:26.887",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37555",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:10.954455Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.620",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37554
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553, CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
},
{
"lang": "es",
"value": "En m\u00faltiples versiones de m\u00faltiples productos de Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, las solicitudes de comunicaci\u00f3n de red espec\u00edficas con contenido inconsistente pueden causar que el componente CmpAppBP lea internamente desde una direcci\u00f3n inv\u00e1lida, potencialmente conduciendo a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente de CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 y CVE-2023-37556."
}
],
"id": "CVE-2023-37554",
"lastModified": "2026-06-17T06:08:26.737",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37554",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:05:06.756495Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.530",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37553
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
},
{
"lang": "es",
"value": "En m\u00faltiples versiones de m\u00faltiples productos de Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, las solicitudes de comunicaci\u00f3n de red con contenido inconsistente pueden causar que el componente CmpAppBP lea internamente desde una direcci\u00f3n inv\u00e1lida, potencialmente llevando a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente de CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 y CVE-2023-37556."
}
],
"id": "CVE-2023-37553",
"lastModified": "2026-06-17T06:08:26.590",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37553",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:05:01.815292Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.443",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37552
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
},
{
"lang": "es",
"value": "En varias versiones de varios productos Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpAppBP lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda provocar una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 y CVE-2023-37556."
}
],
"id": "CVE-2023-37552",
"lastModified": "2026-06-17T06:08:26.440",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37552",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:04:09.376275Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.353",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37551
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
6.5 (Medium) - CVSS:3.1/
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
},
{
"lang": "es",
"value": "En m\u00faltiples productos Codesys en m\u00faltiples versiones , despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, las solicitudes de comunicaci\u00f3n de red especialmente dise\u00f1adas pueden utilizar el componente CmpApp para descargar archivos con cualquier extensi\u00f3n de archivo al controlador. A diferencia de la descarga de archivos normal a trav\u00e9s de CmpFileTransfer, aqu\u00ed no se realiza ning\u00fan filtrado de determinados tipos de archivos. Como resultado, la integridad del sistema de ejecuci\u00f3n de control CODESYS puede verse comprometida por los archivos cargados en el controlador."
}
],
"id": "CVE-2023-37551",
"lastModified": "2026-06-17T06:08:26.290",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37551",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:50.770279Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.257",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-552"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-37550
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\n\n"
},
{
"lang": "es",
"value": "En muchos productos Codesys en m\u00faltiples versiones, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpApp lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda conducir a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 y CVE-2023-37549."
}
],
"id": "CVE-2023-37550",
"lastModified": "2026-06-17T06:08:26.137",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37550",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:46.088420Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.170",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37549
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550\n\n"
},
{
"lang": "es",
"value": "En m\u00faltiples productos de Codesys en m\u00faltiples versiones, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, solicitudes espec\u00edficas de comunicaci\u00f3n de red con contenido inconsistente pueden causar que el componente CmpApp lea internamente desde una direcci\u00f3n inv\u00e1lida, potencialmente llevando a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente de CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 y CVE-2023-37550."
}
],
"id": "CVE-2023-37549",
"lastModified": "2026-06-17T06:08:25.990",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37549",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:40.613696Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.083",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37548
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"id": "CVE-2023-37548",
"lastModified": "2026-06-17T06:08:25.840",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37548",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:49.760916Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:09.997",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37547
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"id": "CVE-2023-37547",
"lastModified": "2026-06-17T06:08:25.693",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37547",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:39.095120Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:09.910",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37546
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"id": "CVE-2023-37546",
"lastModified": "2026-06-17T06:08:25.510",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37546",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:33.810402Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:09.790",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37545
Vulnerability from fkie_nvd - Published: 2023-08-03 11:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550\n\n"
}
],
"id": "CVE-2023-37545",
"lastModified": "2026-06-17T06:08:25.257",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37545",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:27.383050Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T11:15:09.837",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-4224
Vulnerability from fkie_nvd - Published: 2023-03-23 12:15 - Updated: 2026-06-17 05:20
Severity
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/
Summary
In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Control RTE (SL) ",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": " Runtime Toolkit ",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Safety SIL2 PSP",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "HMI (SL) ",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": " Control for BeagleBone SL ",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": " Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": " Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.8.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "40CAED29-E204-459D-8AFC-F814E68FAB9A",
"versionEndExcluding": "4.8.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C5E9691E-E67A-4D59-9152-3731DD381CF4",
"versionEndExcluding": "4.8.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A5FC8BEB-DB37-4486-BAFD-16B82F331F9C",
"versionEndExcluding": "4.8.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D2821B72-748A-4B3E-BD8B-E55C92A1A166",
"versionEndExcluding": "4.8.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "680C2604-3774-43D2-9DDE-38A0F593BFF3",
"versionEndExcluding": "4.8.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D4B2CB47-68F3-4C17-8D61-88F655CF19ED",
"versionEndExcluding": "4.8.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6E3514C8-F513-4576-8F6D-DDB193E3B947",
"versionEndExcluding": "4.8.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5059640A-05F0-4D59-9682-BC09F155527C",
"versionEndExcluding": "4.8.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7D13CFF-F753-430B-9E03-F3F24066B529",
"versionEndExcluding": "4.8.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C27B4D20-FDE3-4003-97BD-F43EE147AD6A",
"versionEndExcluding": "3.5.19.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "63A8AFF5-3CC8-43FA-A9D3-A6A53FAF15FC",
"versionEndExcluding": "3.5.19.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A1A44FED-CFBB-454A-B8E8-FC11A996488F",
"versionEndExcluding": "3.5.19.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8297903A-80E1-4FA7-B552-672B94B6B6B4",
"versionEndExcluding": "3.5.19.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "57C60464-F6BB-431A-AD96-32B07FD99948",
"versionEndExcluding": "3.5.19.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0032B82B-21B9-4006-A7E4-CD5B92962136",
"versionEndExcluding": "3.5.19.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B7181873-775F-43A6-BDBB-DBB2879C7D4D",
"versionEndExcluding": "3.5.19.0",
"versionStartIncluding": "3.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple products of CODESYS v3 in multiple versions a remote low privileged user\u00a0could utilize this vulnerability to read and modify system files and OS resources or DoS the device."
}
],
"id": "CVE-2022-4224",
"lastModified": "2026-06-17T05:20:18.343",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-4224",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:07:26.160566Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-03-23T12:15:12.990",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17553\u0026token=cf49757d232ea8021f0c0dd6c65e71ea5942b12d\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17553\u0026token=cf49757d232ea8021f0c0dd6c65e71ea5942b12d\u0026download="
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-1188"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-1188"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2020-7052
Vulnerability from fkie_nvd - Published: 2020-01-24 20:15 - Updated: 2026-06-17 03:24
Severity
Summary
CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B4E5BF9F-79C9-48D3-9F2D-CCDF73144FCA",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "221CAFE3-1BC7-4CAC-B3F8-981B3F267CFE",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9B048CEB-E1D0-4EF1-9BD3-966CB9E147D8",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A72217A3-4591-4C52-AB37-7FD652276569",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
"matchCriteriaId": "51EFD6C4-C1AC-45D7-909F-6B074B32090E",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8C1B75F5-F426-4877-9004-1F714B2A4968",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2F150E51-4E03-40A8-8099-E5BE13234DD9",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8D839D59-8090-4158-A2C2-847DEDD9674D",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E278A9AE-5684-4F7E-B253-0F70CA835322",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.5.8.60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:beckhoff_cx:*:*",
"matchCriteriaId": "650315EF-4AC2-4B5B-A5A1-8ABBE6C398B6",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.5.8.60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B8C46635-3068-4DDA-8527-2E473763E652",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B7F22E48-0C8D-47C2-8C88-F35ED1027465",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.5.9.80",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5A487191-D2CD-484B-88D3-C7A1EFD8C19B",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.5.15.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0B3462D2-9AA7-4046-B491-36A2A9970BA7",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.5.10.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4F4FCCC9-6069-47D6-AB46-65697F7AE58D",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:simulation_runtime:*:*:*:*:*:*:*:*",
"matchCriteriaId": "375689F5-9B58-491C-BD1C-2CF5C9CEB474",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.5.9.40",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition."
},
{
"lang": "es",
"value": "CODESYS Control versi\u00f3n V3, Gateway versi\u00f3n V3 y HMI versiones V3 anteriores a 3.5.15.30, permiten una asignaci\u00f3n de memoria no controlada que puede resultar en una condici\u00f3n de denegaci\u00f3n de servicio remota."
}
],
"id": "CVE-2020-7052",
"lastModified": "2026-06-17T03:24:14.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-01-24T20:15:10.970",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12977\u0026token=33f948eed0c2fd69d238d9515779be337ef7592d\u0026download="
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12977\u0026token=33f948eed0c2fd69d238d9515779be337ef7592d\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-04"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-770"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-9009
Vulnerability from fkie_nvd - Published: 2019-09-17 16:15 - Updated: 2026-06-17 02:42
Severity
Summary
An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12941&token=50fabe3870c7bdc41701eb1799dddeec103de40c&download= | Vendor Advisory | |
| cve@mitre.org | https://www.us-cert.gov/ics/advisories/icsa-19-255-05 | Mitigation, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12941&token=50fabe3870c7bdc41701eb1799dddeec103de40c&download= | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-255-05 | Mitigation, Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| codesys | control_for_beaglebone | * | |
| codesys | control_for_empc-a\/imx6 | * | |
| codesys | control_for_iot2000 | * | |
| codesys | control_for_pfc100 | * | |
| codesys | control_for_pfc200 | * | |
| codesys | control_for_raspberry_pi | * | |
| codesys | control_rte | * | |
| codesys | control_win | * | |
| codesys | gateway | * | |
| codesys | hmi | * | |
| codesys | linux | * | |
| codesys | runtime_system_toolkit | * | |
| codesys | safety_sil2 | * | |
| codesys | simulation_runtime | * |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "958821C8-142A-4B67-857B-63A6AD53E1B8",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B9940444-8CFD-4044-8662-FDC11E93E6E4",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "805D48DF-DA8F-40AB-B7AE-B2F0A75616E9",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EAEAC81A-4FFA-4692-961D-7DF58E2B0CDE",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2506A775-D1FB-4C2F-98EC-B781AA19E340",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "963C9351-B167-4C1F-914E-A7009A532A0F",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0A5F978B-5245-41D9-B11C-B27703A2A090",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1429532E-76A8-4987-B916-AA3FD7C37E06",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "563FD9B0-D6F5-4A4C-A43D-555C2DC60DD4",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ABFC0D89-BD79-4032-B0CA-08C4F8EA1776",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:linux:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4A2B09D6-8FD2-46FA-A1B2-55B7E996D71B",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "417EFF04-1584-44C3-8AD9-593174089A31",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "139851DD-0E16-4C8D-AA55-0231B2C443A7",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:simulation_runtime:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3FB11CE8-8B22-4D2D-A0A9-4D23C30A3FF5",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash."
},
{
"lang": "es",
"value": "Se descubri\u00f3 un problema en 3S-Smart CODESYS versiones anteriores a 3.5.15.0. Unos paquetes de red dise\u00f1ados causan que el Control Runtime se bloquee."
}
],
"id": "CVE-2019-9009",
"lastModified": "2026-06-17T02:42:54.843",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-09-17T16:15:11.077",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12941\u0026token=50fabe3870c7bdc41701eb1799dddeec103de40c\u0026download="
},
{
"source": "cve@mitre.org",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-05"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12941\u0026token=50fabe3870c7bdc41701eb1799dddeec103de40c\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-05"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-755"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-20026
Vulnerability from fkie_nvd - Published: 2019-02-19 21:29 - Updated: 2026-06-17 01:52
Severity
Summary
Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0.
References
| URL | Tags | ||
|---|---|---|---|
| vulnerability@kaspersky.com | http://www.securityfocus.com/bid/106251 | Broken Link, Third Party Advisory, VDB Entry | |
| vulnerability@kaspersky.com | https://ics-cert.kaspersky.com/advisories/klcert-advisories/2018/12/19/klcert-18-036-codesys-control-v3-improper-communication-address-filtering/ | Mitigation, Third Party Advisory | |
| vulnerability@kaspersky.com | https://ics-cert.us-cert.gov/advisories/ICSA-18-352-04 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/106251 | Broken Link, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.kaspersky.com/advisories/klcert-advisories/2018/12/19/klcert-18-036-codesys-control-v3-improper-communication-address-filtering/ | Mitigation, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-352-04 | Third Party Advisory, US Government Resource |
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "CODESYS V3 products",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "prior V3.5.14.0"
}
]
}
],
"source": "vulnerability@kaspersky.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "30E5A50D-470A-4C7D-A634-E97AE95B38B5",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "455BEF47-4D2A-4314-AF1D-C5C46236B135",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D2E52640-4AA9-40C1-A00E-374334F761C7",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C87347FA-38EA-4299-A822-63FCF0E34577",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8D3E05BC-83BC-49C8-91AD-64A1EE9D36BD",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "40D2875A-E1DF-4C7D-9DD7-7BE8D617EF3C",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE9699B0-CCE3-42AB-8208-492382D59582",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "20CFD36A-208D-444C-A3C3-C2B11CAF65AC",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "6368AFD2-D0F4-4E93-9D28-00D2DAF6F1BD",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1E623E98-8040-43D2-81B5-D6B06B374472",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AA6D880C-195D-4830-B0B5-7D7BC32182B4",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system_v3:*:*:*:*:*:*:*:*",
"matchCriteriaId": "00F359B4-0530-47A3-BFBB-BA7D32104919",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "498AB0A1-C9F2-40A5-BC72-9CC4F96D74DE",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "63F51840-0A93-43BD-B8D0-145C7C52C7B0",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:opc_server:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A3A3A591-9B7A-4328-93C8-728D3E3E045D",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:plchandler:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E7E0C96B-5FD4-422A-B429-860192BC46A0",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6C0A629A-E3CE-428A-81C1-25965A681B73",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:targetvisu_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BA2E1543-D82B-4BE7-8C9C-4EAABFB1F68B",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0."
},
{
"lang": "es",
"value": "Existe el filtrado de direcciones de comunicaci\u00f3n incorrecto en los productos de CODESYS, en sus versiones V3 anteriores a la V3.5.14.0."
}
],
"id": "CVE-2018-20026",
"lastModified": "2026-06-17T01:52:11.860",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-02-19T21:29:00.290",
"references": [
{
"source": "vulnerability@kaspersky.com",
"tags": [
"Broken Link",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/106251"
},
{
"source": "vulnerability@kaspersky.com",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2018/12/19/klcert-18-036-codesys-control-v3-improper-communication-address-filtering/"
},
{
"source": "vulnerability@kaspersky.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link",
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/106251"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2018/12/19/klcert-18-036-codesys-control-v3-improper-communication-address-filtering/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-04"
}
],
"sourceIdentifier": "vulnerability@kaspersky.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-20025
Vulnerability from fkie_nvd - Published: 2019-02-19 21:29 - Updated: 2026-06-17 01:52
Severity
Summary
Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "CODESYS V3 products",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "prior V3.5.14.0"
}
]
}
],
"source": "vulnerability@kaspersky.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "30E5A50D-470A-4C7D-A634-E97AE95B38B5",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "455BEF47-4D2A-4314-AF1D-C5C46236B135",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D2E52640-4AA9-40C1-A00E-374334F761C7",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C87347FA-38EA-4299-A822-63FCF0E34577",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8D3E05BC-83BC-49C8-91AD-64A1EE9D36BD",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "40D2875A-E1DF-4C7D-9DD7-7BE8D617EF3C",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE9699B0-CCE3-42AB-8208-492382D59582",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "20CFD36A-208D-444C-A3C3-C2B11CAF65AC",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "6368AFD2-D0F4-4E93-9D28-00D2DAF6F1BD",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1E623E98-8040-43D2-81B5-D6B06B374472",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AA6D880C-195D-4830-B0B5-7D7BC32182B4",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "087FE9CF-7492-416A-9585-0E8C00ABB320",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "498AB0A1-C9F2-40A5-BC72-9CC4F96D74DE",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "63F51840-0A93-43BD-B8D0-145C7C52C7B0",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6C0A629A-E3CE-428A-81C1-25965A681B73",
"versionEndExcluding": "3.5.14.0",
"versionStartIncluding": "3.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0."
},
{
"lang": "es",
"value": "Existen valores aleatorios utilizados de manera insuficiente en los productos de CODESYS, en sus versiones V3 anteriores a la V3.5.14.0."
}
],
"id": "CVE-2018-20025",
"lastModified": "2026-06-17T01:52:11.730",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-02-19T21:29:00.243",
"references": [
{
"source": "vulnerability@kaspersky.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/106251"
},
{
"source": "vulnerability@kaspersky.com",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2018/12/19/klcert-18-037-codesys-control-v3-use-of-insufficiently-random-values/"
},
{
"source": "vulnerability@kaspersky.com",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/106251"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2018/12/19/klcert-18-037-codesys-control-v3-use-of-insufficiently-random-values/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-04"
}
],
"sourceIdentifier": "vulnerability@kaspersky.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-330"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2023-37559 (GCVE-0-2023-37559)
Vulnerability from nvd – Published: 2023-08-03 11:06 – Updated: 2024-10-11 18:09
VLAI
EPSS
VEX
Title
CODESYS Improper Validation of Consistency within Input in multiple products
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-11 18:07 UTC
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.700Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37559",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:28.102576Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:05.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:56.079Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Validation of Consistency within Input in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37559",
"datePublished": "2023-08-03T11:06:56.079Z",
"dateReserved": "2023-07-07T07:39:19.122Z",
"dateUpdated": "2024-10-11T18:09:05.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37558 (GCVE-0-2023-37558)
Vulnerability from nvd – Published: 2023-08-03 11:06 – Updated: 2024-10-11 18:09
VLAI
EPSS
VEX
Title
CODESYS Improper Validation of Consistency within Input in multiple products
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-11 18:07 UTC
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.767Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37558",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:13.616622Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:20.780Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:36.112Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Validation of Consistency within Input in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37558",
"datePublished": "2023-08-03T11:06:36.112Z",
"dateReserved": "2023-07-07T07:39:19.121Z",
"dateUpdated": "2024-10-11T18:09:20.780Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37557 (GCVE-0-2023-37557)
Vulnerability from nvd – Published: 2023-08-03 11:06 – Updated: 2024-10-09 20:52
VLAI
EPSS
VEX
Title
CODESYS Heap-based Buffer Overflow in multiple products
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-09 20:48 UTC
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.379Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37557",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:48:56.664856Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:16.817Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:17.884Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Heap-based Buffer Overflow in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37557",
"datePublished": "2023-08-03T11:06:17.884Z",
"dateReserved": "2023-07-07T07:39:19.121Z",
"dateUpdated": "2024-10-09T20:52:16.817Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37556 (GCVE-0-2023-37556)
Vulnerability from nvd – Published: 2023-08-03 11:05 – Updated: 2024-10-09 20:52
VLAI
EPSS
VEX
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-09 20:49 UTC
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.852Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37556",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:03.697246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:36.722Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553,\u0026nbsp;CVE-2023-37554 and CVE-2023-37555.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and CVE-2023-37555.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:52.986Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37556",
"datePublished": "2023-08-03T11:05:52.986Z",
"dateReserved": "2023-07-07T07:39:19.120Z",
"dateUpdated": "2024-10-09T20:52:36.722Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37555 (GCVE-0-2023-37555)
Vulnerability from nvd – Published: 2023-08-03 11:05 – Updated: 2024-10-09 20:52
VLAI
EPSS
VEX
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-09 20:49 UTC
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.445Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37555",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:10.954455Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:51.974Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553,\u0026nbsp;CVE-2023-37554 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:33.660Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37555",
"datePublished": "2023-08-03T11:05:33.660Z",
"dateReserved": "2023-07-07T07:39:19.120Z",
"dateUpdated": "2024-10-09T20:52:51.974Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37554 (GCVE-0-2023-37554)
Vulnerability from nvd – Published: 2023-08-03 11:05 – Updated: 2024-10-11 18:09
VLAI
EPSS
VEX
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-11 18:05 UTC
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37554",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:05:06.756495Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:34.979Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553, CVE-2023-37555 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553, CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:09.750Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37554",
"datePublished": "2023-08-03T11:05:09.750Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:09:34.979Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37553 (GCVE-0-2023-37553)
Vulnerability from nvd – Published: 2023-08-03 11:04 – Updated: 2024-10-11 18:10
VLAI
EPSS
VEX
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-11 18:05 UTC
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.602Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37553",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:05:01.815292Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:10:16.403Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37554,\u0026nbsp;CVE-2023-37555 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:04:39.061Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37553",
"datePublished": "2023-08-03T11:04:39.061Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:10:16.403Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37552 (GCVE-0-2023-37552)
Vulnerability from nvd – Published: 2023-08-03 11:04 – Updated: 2024-10-11 18:10
VLAI
EPSS
VEX
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-11 18:04 UTC
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.508Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37552",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:04:09.376275Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:10:33.714Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u0026nbsp;CVE-2023-37554,\u0026nbsp;CVE-2023-37555 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:04:04.128Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37552",
"datePublished": "2023-08-03T11:04:04.128Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:10:33.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37551 (GCVE-0-2023-37551)
Vulnerability from nvd – Published: 2023-08-03 11:03 – Updated: 2024-10-11 18:10
VLAI
EPSS
VEX
Title
CODESYS Files or Directories Accessible to External Parties in CmpApp
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-11 18:01 UTC
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.609Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37551",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:50.770279Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:10:51.431Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552 Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:03:37.457Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Files or Directories Accessible to External Parties in CmpApp",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37551",
"datePublished": "2023-08-03T11:03:37.457Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:10:51.431Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37550 (GCVE-0-2023-37550)
Vulnerability from nvd – Published: 2023-08-03 11:03 – Updated: 2024-10-11 18:11
VLAI
EPSS
VEX
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-11 18:01 UTC
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.425Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37550",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:46.088420Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:11:18.756Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u0026nbsp;CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:03:09.222Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37550",
"datePublished": "2023-08-03T11:03:09.222Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:11:18.756Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}