Search
Find a vulnerability
Search criteria
6 vulnerabilities found for rx9_pro by tenda
CVE-2024-10283 (GCVE-0-2024-10283)
Vulnerability from nvd – Published: 2024-10-23 15:00 – Updated: 2024-10-23 17:33
VLAI
EPSS
VEX
Title
Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-23 17:30 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.281558 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.281558 | signaturepermissions-required |
| https://vuldb.com/?submit.427064 | third-party-advisory |
| https://gitee.com/GXB0_0/iot-vul/blob/master/Tend… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rx9_pro",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.20"
}
]
},
{
"cpes": [
"cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rx9",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.20"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10283",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T17:30:46.351880Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T17:33:05.674Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "RX9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.20"
}
]
},
{
"product": "RX9 Pro",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.20"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "GuoXB (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda RX9 and RX9 Pro 22.03.02.20 entdeckt. Betroffen davon ist die Funktion sub_4337EC der Datei /goform/SetNetControlList. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T15:00:12.454Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-281558 | Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.281558"
},
{
"name": "VDB-281558 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.281558"
},
{
"name": "Submit #427064 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.427064"
},
{
"tags": [
"exploit"
],
"url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetNetControlList.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-10-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-10-23T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-10-23T08:12:57.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10283",
"datePublished": "2024-10-23T15:00:12.454Z",
"dateReserved": "2024-10-23T06:07:52.411Z",
"dateUpdated": "2024-10-23T17:33:05.674Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10282 (GCVE-0-2024-10282)
Vulnerability from nvd – Published: 2024-10-23 14:31 – Updated: 2024-10-23 17:51
VLAI
EPSS
VEX
Title
Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-23 17:50 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.281557 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.281557 | signaturepermissions-required |
| https://vuldb.com/?submit.427066 | third-party-advisory |
| https://gitee.com/GXB0_0/iot-vul/blob/master/Tend… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | RX9 |
Affected:
22.03.02.10
Affected: 22.03.02.20 |
|
| Tenda | RX9 Pro |
Affected:
22.03.02.10
Affected: 22.03.02.20 |
|
| tenda | rx9 |
Affected:
22.03.02.10
Affected: 22.03.02.20 cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:* |
|
| tenda | rx9_pro |
Affected:
22.03.02.10
Affected: 22.03.02.20 cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rx9",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rx9_pro",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10282",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T17:50:18.481537Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T17:51:56.577Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "RX9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
},
{
"product": "RX9 Pro",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "GuoXB (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion sub_42EA38 der Datei /goform/SetVirtualServerCfg. Dank Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T14:31:24.051Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-281557 | Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.281557"
},
{
"name": "VDB-281557 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.281557"
},
{
"name": "Submit #427066 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.10\u3001RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.427066"
},
{
"tags": [
"exploit"
],
"url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetVirtualServerCfg.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-10-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-10-23T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-10-23T08:12:46.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10282",
"datePublished": "2024-10-23T14:31:24.051Z",
"dateReserved": "2024-10-23T06:07:37.708Z",
"dateUpdated": "2024-10-23T17:51:56.577Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10281 (GCVE-0-2024-10281)
Vulnerability from nvd – Published: 2024-10-23 14:00 – Updated: 2024-10-23 18:20
VLAI
EPSS
VEX
Title
Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-23 18:19 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.281556 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.281556 | signaturepermissions-required |
| https://vuldb.com/?submit.427065 | third-party-advisory |
| https://gitee.com/GXB0_0/iot-vul/blob/master/Tend… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | RX9 |
Affected:
22.03.02.10
Affected: 22.03.02.20 |
|
| Tenda | RX9 Pro |
Affected:
22.03.02.10
Affected: 22.03.02.20 |
|
| tenda | rx9 |
Affected:
22.03.02.10
Affected: 22.03.02.20 cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:* |
|
| tenda | rx9_pro |
Affected:
22.03.02.10
Affected: 22.03.02.20 cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rx9",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rx9_pro",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10281",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T18:19:28.352564Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T18:20:52.773Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "RX9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
},
{
"product": "RX9 Pro",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "GuoXB (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20 entdeckt. Hiervon betroffen ist die Funktion sub_42EEE0 der Datei /goform/SetStaticRouteCfg. Dank der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T14:00:24.603Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-281556 | Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.281556"
},
{
"name": "VDB-281556 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.281556"
},
{
"name": "Submit #427065 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.10\u3001RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.427065"
},
{
"tags": [
"exploit"
],
"url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetStaticRouteCfg.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-10-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-10-23T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-10-23T08:12:43.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10281",
"datePublished": "2024-10-23T14:00:24.603Z",
"dateReserved": "2024-10-23T06:07:35.435Z",
"dateUpdated": "2024-10-23T18:20:52.773Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10283 (GCVE-0-2024-10283)
Vulnerability from cvelistv5 – Published: 2024-10-23 15:00 – Updated: 2024-10-23 17:33
VLAI
EPSS
VEX
Title
Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-23 17:30 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.281558 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.281558 | signaturepermissions-required |
| https://vuldb.com/?submit.427064 | third-party-advisory |
| https://gitee.com/GXB0_0/iot-vul/blob/master/Tend… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rx9_pro",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.20"
}
]
},
{
"cpes": [
"cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rx9",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.20"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10283",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T17:30:46.351880Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T17:33:05.674Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "RX9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.20"
}
]
},
{
"product": "RX9 Pro",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.20"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "GuoXB (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda RX9 and RX9 Pro 22.03.02.20 entdeckt. Betroffen davon ist die Funktion sub_4337EC der Datei /goform/SetNetControlList. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T15:00:12.454Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-281558 | Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.281558"
},
{
"name": "VDB-281558 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.281558"
},
{
"name": "Submit #427064 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.427064"
},
{
"tags": [
"exploit"
],
"url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetNetControlList.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-10-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-10-23T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-10-23T08:12:57.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10283",
"datePublished": "2024-10-23T15:00:12.454Z",
"dateReserved": "2024-10-23T06:07:52.411Z",
"dateUpdated": "2024-10-23T17:33:05.674Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10282 (GCVE-0-2024-10282)
Vulnerability from cvelistv5 – Published: 2024-10-23 14:31 – Updated: 2024-10-23 17:51
VLAI
EPSS
VEX
Title
Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-23 17:50 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.281557 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.281557 | signaturepermissions-required |
| https://vuldb.com/?submit.427066 | third-party-advisory |
| https://gitee.com/GXB0_0/iot-vul/blob/master/Tend… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | RX9 |
Affected:
22.03.02.10
Affected: 22.03.02.20 |
|
| Tenda | RX9 Pro |
Affected:
22.03.02.10
Affected: 22.03.02.20 |
|
| tenda | rx9 |
Affected:
22.03.02.10
Affected: 22.03.02.20 cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:* |
|
| tenda | rx9_pro |
Affected:
22.03.02.10
Affected: 22.03.02.20 cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rx9",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rx9_pro",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10282",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T17:50:18.481537Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T17:51:56.577Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "RX9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
},
{
"product": "RX9 Pro",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "GuoXB (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion sub_42EA38 der Datei /goform/SetVirtualServerCfg. Dank Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T14:31:24.051Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-281557 | Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.281557"
},
{
"name": "VDB-281557 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.281557"
},
{
"name": "Submit #427066 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.10\u3001RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.427066"
},
{
"tags": [
"exploit"
],
"url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetVirtualServerCfg.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-10-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-10-23T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-10-23T08:12:46.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10282",
"datePublished": "2024-10-23T14:31:24.051Z",
"dateReserved": "2024-10-23T06:07:37.708Z",
"dateUpdated": "2024-10-23T17:51:56.577Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-10281 (GCVE-0-2024-10281)
Vulnerability from cvelistv5 – Published: 2024-10-23 14:00 – Updated: 2024-10-23 18:20
VLAI
EPSS
VEX
Title
Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-23 18:19 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.281556 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.281556 | signaturepermissions-required |
| https://vuldb.com/?submit.427065 | third-party-advisory |
| https://gitee.com/GXB0_0/iot-vul/blob/master/Tend… | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | RX9 |
Affected:
22.03.02.10
Affected: 22.03.02.20 |
|
| Tenda | RX9 Pro |
Affected:
22.03.02.10
Affected: 22.03.02.20 |
|
| tenda | rx9 |
Affected:
22.03.02.10
Affected: 22.03.02.20 cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:* |
|
| tenda | rx9_pro |
Affected:
22.03.02.10
Affected: 22.03.02.20 cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rx9",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rx9_pro",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-10281",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T18:19:28.352564Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T18:20:52.773Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "RX9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
},
{
"product": "RX9 Pro",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "22.03.02.10"
},
{
"status": "affected",
"version": "22.03.02.20"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "GuoXB (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20 entdeckt. Hiervon betroffen ist die Funktion sub_42EEE0 der Datei /goform/SetStaticRouteCfg. Dank der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T14:00:24.603Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-281556 | Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.281556"
},
{
"name": "VDB-281556 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.281556"
},
{
"name": "Submit #427065 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.10\u3001RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.427065"
},
{
"tags": [
"exploit"
],
"url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetStaticRouteCfg.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-10-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-10-23T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-10-23T08:12:43.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-10281",
"datePublished": "2024-10-23T14:00:24.603Z",
"dateReserved": "2024-10-23T06:07:35.435Z",
"dateUpdated": "2024-10-23T18:20:52.773Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}