Search

Find a vulnerability

Search criteria

    3 vulnerabilities found for runtime_plcwinnt by codesys

    FKIE_CVE-2018-25048

    Vulnerability from fkie_nvd - Published: 2023-03-23 11:15 - Updated: 2026-06-17 01:54

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Control for BeagleBone",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": " Control for emPC-A/iMX6",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC100",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC200",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE V3 (all variants)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control Win V3 (all variants)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "V3 Simulation Runtime (part of the CODESYS Development System)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "HMI V3 (all variants)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "V3 Remote Target Visu (all variants)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control V3 Runtime System Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "V3 Embedded Target Visu Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "V3 Remote Target Visu Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime Toolkit 32 bit embedded",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "2.3.2.10",
                  "status": "affected",
                  "version": "2.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime Toolkit 32 bit full",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "2.4.7.52",
                  "status": "affected",
                  "version": "2.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime PLCWinNT",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "2.4.7.52",
                  "status": "affected",
                  "version": "2.0.0.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "info@cert.vde.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B29080C3-A6D8-40D6-8C24-177C00FA27F0",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B980C936-557F-4F14-A692-165129625A62",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D282ECAB-FA07-4A81-8F43-AC46A08422D4",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AC1C508C-6817-42E7-9B4C-CDCAC7477304",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C1ECCA6D-3F95-4924-9CC6-7315B1608217",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "093C888E-8328-45E9-882C-39D7FBE8E251",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4E767B6C-7762-4F3C-A8B0-BEC9C1C238D8",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:control_v3_runtime_system_toolkit:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2DDCE092-30E5-43FB-A20F-A712DFD7B1C3",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A47EA342-7BDA-4707-9A23-142126C407C1",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A0FE0CC3-99BF-46BF-907D-E8F2785310BB",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "157E617E-7432-464A-AEC4-29D3806FA2D2",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D95B012B-C9B0-4E2A-934B-3ECDE463722E",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:runtime_plcwinnt:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8931A117-72B6-4B1C-BF56-E7925D07A790",
                  "versionEndExcluding": "2.4.7.52",
                  "versionStartIncluding": "2.0.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:runtime_system_toolkit:*:*:*:*:*:*:x86:*",
                  "matchCriteriaId": "46335A20-A1BF-4E5B-BB1D-B7A4AFF6DB08",
                  "versionEndExcluding": "2.4.7.52",
                  "versionStartIncluding": "2.0.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:runtime_system_toolkit:3.5.15.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7A3A8DFF-705F-4562-87CE-E899C5DC2D18",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:codesys:simulation_runtime:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9DD3AD40-BEE7-428D-B1F0-1349E10A9DD5",
                  "versionEndExcluding": "3.5.12.30",
                  "versionStartIncluding": "3.0.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device."
        }
      ],
      "id": "CVE-2018-25048",
      "lastModified": "2026-06-17T01:54:36.137",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "info@cert.vde.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2018-25048",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-02-19T21:00:23.308028Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-03-23T11:15:12.730",
      "references": [
        {
          "source": "info@cert.vde.com",
          "tags": [
            "Not Applicable"
          ],
          "url": "https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Not Applicable"
          ],
          "url": "https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf"
        }
      ],
      "sourceIdentifier": "info@cert.vde.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "info@cert.vde.com",
          "type": "Secondary"
        }
      ]
    }

    CVE-2018-25048 (GCVE-0-2018-25048)

    Vulnerability from nvd – Published: 2023-03-23 10:45 – Updated: 2025-02-19 21:00
    VLAI
    Title
    Codesys Runtime Improper Limitation of a Pathname
    Summary
    The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-02-19 21:00 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Impacted products
    Vendor Product Version
    CODESYS Control for BeagleBone Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control for emPC-A/iMX6 Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control for IOT2000 Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control for PFC100 Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control for PFC200 Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control for Raspberry Pi Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control RTE V3 (all variants) Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control Win V3 (all variants) Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS V3 Simulation Runtime (part of the CODESYS Development System) Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS HMI V3 (all variants) Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS V3 Remote Target Visu (all variants) Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control V3 Runtime System Toolkit Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS V3 Embedded Target Visu Toolkit Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS V3 Remote Target Visu Toolkit Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Runtime Toolkit 32 bit embedded Affected: 2.0.0.0 , < 2.3.2.10 (custom)
    Create a notification for this product.
    CODESYS Runtime Toolkit 32 bit full Affected: 2.0.0.0 , < 2.4.7.52 (custom)
    Create a notification for this product.
    CODESYS Runtime PLCWinNT Affected: 2.0.0.0 , < 2.4.7.52 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T12:26:39.648Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2018-25048",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-19T21:00:23.308028Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-19T21:00:29.711Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Control for BeagleBone",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": " Control for emPC-A/iMX6",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC100",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC200",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE V3 (all variants)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control Win V3 (all variants)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "V3 Simulation Runtime (part of the CODESYS Development System)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "HMI V3 (all variants)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "V3 Remote Target Visu (all variants)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control V3 Runtime System Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "V3 Embedded Target Visu Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "V3 Remote Target Visu Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime Toolkit 32 bit embedded",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "2.3.2.10",
                  "status": "affected",
                  "version": "2.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime Toolkit 32 bit full",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "2.4.7.52",
                  "status": "affected",
                  "version": "2.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime PLCWinNT",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "2.4.7.52",
                  "status": "affected",
                  "version": "2.0.0.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": " Prosoft-Systems Ltd."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device."
                }
              ],
              "value": "The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-03-23T10:45:36.900Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64324"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "Codesys Runtime  Improper Limitation of a Pathname",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2018-25048",
        "datePublished": "2023-03-23T10:45:36.900Z",
        "dateReserved": "2022-12-07T12:06:08.365Z",
        "dateUpdated": "2025-02-19T21:00:29.711Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-25048 (GCVE-0-2018-25048)

    Vulnerability from cvelistv5 – Published: 2023-03-23 10:45 – Updated: 2025-02-19 21:00
    VLAI
    Title
    Codesys Runtime Improper Limitation of a Pathname
    Summary
    The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-02-19 21:00 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    Impacted products
    Vendor Product Version
    CODESYS Control for BeagleBone Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control for emPC-A/iMX6 Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control for IOT2000 Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control for PFC100 Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control for PFC200 Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control for Raspberry Pi Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control RTE V3 (all variants) Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control Win V3 (all variants) Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS V3 Simulation Runtime (part of the CODESYS Development System) Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS HMI V3 (all variants) Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS V3 Remote Target Visu (all variants) Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Control V3 Runtime System Toolkit Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS V3 Embedded Target Visu Toolkit Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS V3 Remote Target Visu Toolkit Affected: 3.0.0.0 , < 3.5.12.30 (custom)
    Create a notification for this product.
    CODESYS Runtime Toolkit 32 bit embedded Affected: 2.0.0.0 , < 2.3.2.10 (custom)
    Create a notification for this product.
    CODESYS Runtime Toolkit 32 bit full Affected: 2.0.0.0 , < 2.4.7.52 (custom)
    Create a notification for this product.
    CODESYS Runtime PLCWinNT Affected: 2.0.0.0 , < 2.4.7.52 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T12:26:39.648Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2018-25048",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-19T21:00:23.308028Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-19T21:00:29.711Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Control for BeagleBone",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": " Control for emPC-A/iMX6",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for IOT2000",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC100",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for PFC200",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control for Raspberry Pi",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control RTE V3 (all variants)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control Win V3 (all variants)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "V3 Simulation Runtime (part of the CODESYS Development System)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "HMI V3 (all variants)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "V3 Remote Target Visu (all variants)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Control V3 Runtime System Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "V3 Embedded Target Visu Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "V3 Remote Target Visu Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.12.30",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime Toolkit 32 bit embedded",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "2.3.2.10",
                  "status": "affected",
                  "version": "2.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime Toolkit 32 bit full",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "2.4.7.52",
                  "status": "affected",
                  "version": "2.0.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Runtime PLCWinNT",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "2.4.7.52",
                  "status": "affected",
                  "version": "2.0.0.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": " Prosoft-Systems Ltd."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device."
                }
              ],
              "value": "The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-03-23T10:45:36.900Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64324"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "Codesys Runtime  Improper Limitation of a Pathname",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2018-25048",
        "datePublished": "2023-03-23T10:45:36.900Z",
        "dateReserved": "2022-12-07T12:06:08.365Z",
        "dateUpdated": "2025-02-19T21:00:29.711Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }