Search
Find a vulnerability
Search criteria
4 vulnerabilities found for ruggedcom_apr1808_firmware by siemens
CVE-2021-33626 (GCVE-0-2021-33626)
Vulnerability from nvd – Published: 2021-10-01 02:21 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2021001 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:30.965Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:05.856Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:07:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"source": {
"discovery": "INTERNAL"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-33626",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2021001",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0006/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
},
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-33626",
"datePublished": "2021-10-01T02:21:29.000Z",
"dateReserved": "2021-05-28T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:05.856Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-27339 (GCVE-0-2020-27339)
Vulnerability from nvd – Published: 2021-06-16 15:49 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge/SA-2021001 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:22.115Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0005/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:03.345Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:07:12.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0005/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-27339",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge/SA-2021001",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0005/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0005/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-27339",
"datePublished": "2021-06-16T15:49:34.000Z",
"dateReserved": "2020-10-20T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:03.345Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-33626 (GCVE-0-2021-33626)
Vulnerability from cvelistv5 – Published: 2021-10-01 02:21 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2021001 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:30.965Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:05.856Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:07:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"source": {
"discovery": "INTERNAL"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-33626",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2021001",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0006/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
},
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-33626",
"datePublished": "2021-10-01T02:21:29.000Z",
"dateReserved": "2021-05-28T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:05.856Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-27339 (GCVE-0-2020-27339)
Vulnerability from cvelistv5 – Published: 2021-06-16 15:49 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge/SA-2021001 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:22.115Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0005/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:03.345Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:07:12.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0005/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-27339",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge/SA-2021001",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2021001"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0005/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0005/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-27339",
"datePublished": "2021-06-16T15:49:34.000Z",
"dateReserved": "2020-10-20T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:03.345Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}