Search criteria

2 vulnerabilities found for rp-210e_firmware by auto-maskin

CVE-2018-5399 (GCVE-0-2018-5399)

Vulnerability from nvd – Published: 2018-10-08 15:00 – Updated: 2024-09-17 00:11
VLAI?
Title
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running and is configured with a hard-coded credentials
Summary
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
Vendor Product Version
Auto-Maskin DCU-210E Affected: 3.7 , < 3.7 (custom)
Create a notification for this product.
    Auto-Maskin RP-210E Affected: 3.7 , < 3.7 (custom)
Create a notification for this product.
Credits
Reporters: Brian Satira, Brian Olson, Organization: Project Gunsway
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:33:44.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VU#176301",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "https://www.kb.cert.org/vuls/id/176301"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "ARMv7"
          ],
          "product": "DCU-210E",
          "vendor": "Auto-Maskin",
          "versions": [
            {
              "lessThan": "3.7",
              "status": "affected",
              "version": "3.7",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARMv7"
          ],
          "product": "RP-210E",
          "vendor": "Auto-Maskin",
          "versions": [
            {
              "lessThan": "3.7",
              "status": "affected",
              "version": "3.7",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Reporters: Brian Satira, Brian Olson, Organization: Project Gunsway"
        }
      ],
      "datePublic": "2018-10-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798: Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-24T14:50:38",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "name": "VU#176301",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "https://www.kb.cert.org/vuls/id/176301"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "End-users should log-in via the SSH server and remove it as a service, or change the hard-coded password to SP 800-63B standards."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running and is configured with a hard-coded credentials",
      "workarounds": [
        {
          "lang": "en",
          "value": "End-users should log-in via the SSH server and remove it as a service, or change the hard-coded password to SP 800-63B standards."
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "DATE_PUBLIC": "2018-10-01T04:00:00.000Z",
          "ID": "CVE-2018-5399",
          "STATE": "PUBLIC",
          "TITLE": "The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running and is configured with a hard-coded credentials"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DCU-210E",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "platform": "ARMv7",
                            "version_affected": "\u003c",
                            "version_name": "3.7",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RP-210E",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "platform": "ARMv7",
                            "version_affected": "\u003c",
                            "version_name": "3.7",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Auto-Maskin"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Reporters: Brian Satira, Brian Olson, Organization: Project Gunsway"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798: Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "VU#176301",
              "refsource": "CERT-VN",
              "url": "https://www.kb.cert.org/vuls/id/176301"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "End-users should log-in via the SSH server and remove it as a service, or change the hard-coded password to SP 800-63B standards."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "End-users should log-in via the SSH server and remove it as a service, or change the hard-coded password to SP 800-63B standards."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2018-5399",
    "datePublished": "2018-10-08T15:00:00Z",
    "dateReserved": "2018-01-12T00:00:00",
    "dateUpdated": "2024-09-17T00:11:46.657Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-5399 (GCVE-0-2018-5399)

Vulnerability from cvelistv5 – Published: 2018-10-08 15:00 – Updated: 2024-09-17 00:11
VLAI?
Title
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running and is configured with a hard-coded credentials
Summary
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
Vendor Product Version
Auto-Maskin DCU-210E Affected: 3.7 , < 3.7 (custom)
Create a notification for this product.
    Auto-Maskin RP-210E Affected: 3.7 , < 3.7 (custom)
Create a notification for this product.
Credits
Reporters: Brian Satira, Brian Olson, Organization: Project Gunsway
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:33:44.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VU#176301",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "https://www.kb.cert.org/vuls/id/176301"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "ARMv7"
          ],
          "product": "DCU-210E",
          "vendor": "Auto-Maskin",
          "versions": [
            {
              "lessThan": "3.7",
              "status": "affected",
              "version": "3.7",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARMv7"
          ],
          "product": "RP-210E",
          "vendor": "Auto-Maskin",
          "versions": [
            {
              "lessThan": "3.7",
              "status": "affected",
              "version": "3.7",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Reporters: Brian Satira, Brian Olson, Organization: Project Gunsway"
        }
      ],
      "datePublic": "2018-10-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798: Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-24T14:50:38",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "name": "VU#176301",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "https://www.kb.cert.org/vuls/id/176301"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "End-users should log-in via the SSH server and remove it as a service, or change the hard-coded password to SP 800-63B standards."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running and is configured with a hard-coded credentials",
      "workarounds": [
        {
          "lang": "en",
          "value": "End-users should log-in via the SSH server and remove it as a service, or change the hard-coded password to SP 800-63B standards."
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "DATE_PUBLIC": "2018-10-01T04:00:00.000Z",
          "ID": "CVE-2018-5399",
          "STATE": "PUBLIC",
          "TITLE": "The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running and is configured with a hard-coded credentials"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DCU-210E",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "platform": "ARMv7",
                            "version_affected": "\u003c",
                            "version_name": "3.7",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RP-210E",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "platform": "ARMv7",
                            "version_affected": "\u003c",
                            "version_name": "3.7",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Auto-Maskin"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Reporters: Brian Satira, Brian Olson, Organization: Project Gunsway"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798: Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "VU#176301",
              "refsource": "CERT-VN",
              "url": "https://www.kb.cert.org/vuls/id/176301"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "End-users should log-in via the SSH server and remove it as a service, or change the hard-coded password to SP 800-63B standards."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "End-users should log-in via the SSH server and remove it as a service, or change the hard-coded password to SP 800-63B standards."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2018-5399",
    "datePublished": "2018-10-08T15:00:00Z",
    "dateReserved": "2018-01-12T00:00:00",
    "dateUpdated": "2024-09-17T00:11:46.657Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}