Search

Find a vulnerability

Search criteria

    10 vulnerabilities found for roboguide by fanuc

    CVE-2021-43990 (GCVE-0-2021-43990)

    Vulnerability from nvd – Published: 2022-04-20 15:30 – Updated: 2025-04-16 16:29
    VLAI
    Title
    ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform
    Summary
    The affected product is vulnerable to a network-based attack by threat actors supplying a crafted, malicious XML payload designed to trigger an external entity reference call.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
    Assigner
    References
    Impacted products
    Vendor Product Version
    FANUC ROBOGUIDE Affected: All , < v9.40083.00.05 (Rev T) (custom)
    Create a notification for this product.
    Date Public
    2022-04-19 00:00
    Credits
    Sharon Brizinov with Claroty reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:16.950Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43990",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:53.308160Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:29:08.202Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ROBOGUIDE",
              "vendor": "FANUC",
              "versions": [
                {
                  "lessThan": "v9.40083.00.05 (Rev T)",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-04-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to a network-based attack by threat actors supplying a crafted, malicious XML payload designed to trigger an external entity reference call."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-20T15:30:28.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-04-19T21:16:00.000Z",
              "ID": "CVE-2021-43990",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ROBOGUIDE",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "v9.40083.00.05 (Rev T)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "FANUC"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to a network-based attack by threat actors supplying a crafted, malicious XML payload designed to trigger an external entity reference call."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43990",
        "datePublished": "2022-04-20T15:30:28.424Z",
        "dateReserved": "2021-11-17T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:29:08.202Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43988 (GCVE-0-2021-43988)

    Vulnerability from nvd – Published: 2022-04-20 15:30 – Updated: 2025-04-16 16:28
    VLAI
    Title
    ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform
    Summary
    The affected product is vulnerable to a network-based attack by threat actors utilizing crafted naming conventions of files to gain unauthorized access rights.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    Impacted products
    Vendor Product Version
    FANUC ROBOGUIDE Affected: All , < v9.40083.00.05 (Rev T) (custom)
    Create a notification for this product.
    Date Public
    2022-04-19 00:00
    Credits
    Sharon Brizinov with Claroty reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.096Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43988",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:36.544578Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:28:37.927Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ROBOGUIDE",
              "vendor": "FANUC",
              "versions": [
                {
                  "lessThan": "v9.40083.00.05 (Rev T)",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-04-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to a network-based attack by threat actors utilizing crafted naming conventions of files to gain unauthorized access rights."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-20T15:30:31.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-04-19T21:16:00.000Z",
              "ID": "CVE-2021-43988",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ROBOGUIDE",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "v9.40083.00.05 (Rev T)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "FANUC"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to a network-based attack by threat actors utilizing crafted naming conventions of files to gain unauthorized access rights."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43988",
        "datePublished": "2022-04-20T15:30:31.734Z",
        "dateReserved": "2021-11-17T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:28:37.927Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43986 (GCVE-0-2021-43986)

    Vulnerability from nvd – Published: 2022-04-20 15:30 – Updated: 2025-04-16 16:29
    VLAI
    Title
    ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform
    Summary
    The setup program for the affected product configures its files and folders with full access, which may allow unauthorized users permission to replace original binaries and achieve privilege escalation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    FANUC ROBOGUIDE Affected: All , < v9.40083.00.05 (Rev T) (custom)
    Create a notification for this product.
    Date Public
    2022-04-19 00:00
    Credits
    Sharon Brizinov with Claroty reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:16.964Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43986",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:49.356686Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:29:00.294Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ROBOGUIDE",
              "vendor": "FANUC",
              "versions": [
                {
                  "lessThan": "v9.40083.00.05 (Rev T)",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-04-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The setup program for the affected product configures its files and folders with full access, which may allow unauthorized users permission to replace original binaries and achieve privilege escalation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-20T15:30:29.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-04-19T21:16:00.000Z",
              "ID": "CVE-2021-43986",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ROBOGUIDE",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "v9.40083.00.05 (Rev T)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "FANUC"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The setup program for the affected product configures its files and folders with full access, which may allow unauthorized users permission to replace original binaries and achieve privilege escalation."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-284 Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43986",
        "datePublished": "2022-04-20T15:30:29.227Z",
        "dateReserved": "2021-11-17T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:29:00.294Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43933 (GCVE-0-2021-43933)

    Vulnerability from nvd – Published: 2022-04-20 15:30 – Updated: 2025-04-16 16:28
    VLAI
    Title
    ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform
    Summary
    The affected product is vulnerable to a network-based attack by threat actors sending unimpeded requests to the receiving server, which could cause a denial-of-service condition due to lack of heap memory resources.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    References
    Impacted products
    Vendor Product Version
    FANUC ROBOGUIDE Affected: All , < v9.40083.00.05 (Rev T) (custom)
    Create a notification for this product.
    Date Public
    2022-04-19 00:00
    Credits
    Sharon Brizinov with Claroty reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.020Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43933",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:41.984140Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:28:45.372Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ROBOGUIDE",
              "vendor": "FANUC",
              "versions": [
                {
                  "lessThan": "v9.40083.00.05 (Rev T)",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-04-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to a network-based attack by threat actors sending unimpeded requests to the receiving server, which could cause a denial-of-service condition due to lack of heap memory resources."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400 Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-20T15:30:30.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-04-19T21:16:00.000Z",
              "ID": "CVE-2021-43933",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ROBOGUIDE",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "v9.40083.00.05 (Rev T)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "FANUC"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to a network-based attack by threat actors sending unimpeded requests to the receiving server, which could cause a denial-of-service condition due to lack of heap memory resources."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-400 Uncontrolled Resource Consumption"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43933",
        "datePublished": "2022-04-20T15:30:30.872Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:28:45.372Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-38483 (GCVE-0-2021-38483)

    Vulnerability from nvd – Published: 2022-04-20 15:30 – Updated: 2025-04-16 16:28
    VLAI
    Title
    ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform
    Summary
    The affected product is vulnerable to misconfigured binaries, allowing users on the target PC with SYSTEM level privileges access to overwrite the binary and modify files to gain privilege escalation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    References
    Impacted products
    Vendor Product Version
    FANUC ROBOGUIDE Affected: All , < v9.40083.00.05 (Rev T) (custom)
    Create a notification for this product.
    Date Public
    2022-04-19 00:00
    Credits
    Sharon Brizinov with Claroty reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:44:22.805Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-38483",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:46.426654Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:28:52.540Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ROBOGUIDE",
              "vendor": "FANUC",
              "versions": [
                {
                  "lessThan": "v9.40083.00.05 (Rev T)",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-04-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to misconfigured binaries, allowing users on the target PC with SYSTEM level privileges access to overwrite the binary and modify files to gain privilege escalation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-20T15:30:30.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-04-19T21:16:00.000Z",
              "ID": "CVE-2021-38483",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ROBOGUIDE",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "v9.40083.00.05 (Rev T)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "FANUC"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to misconfigured binaries, allowing users on the target PC with SYSTEM level privileges access to overwrite the binary and modify files to gain privilege escalation."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-732 Incorrect Permission Assignment for Critical Resource"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-38483",
        "datePublished": "2022-04-20T15:30:30.126Z",
        "dateReserved": "2021-08-10T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:28:52.540Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43988 (GCVE-0-2021-43988)

    Vulnerability from cvelistv5 – Published: 2022-04-20 15:30 – Updated: 2025-04-16 16:28
    VLAI
    Title
    ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform
    Summary
    The affected product is vulnerable to a network-based attack by threat actors utilizing crafted naming conventions of files to gain unauthorized access rights.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    Impacted products
    Vendor Product Version
    FANUC ROBOGUIDE Affected: All , < v9.40083.00.05 (Rev T) (custom)
    Create a notification for this product.
    Date Public
    2022-04-19 00:00
    Credits
    Sharon Brizinov with Claroty reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.096Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43988",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:36.544578Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:28:37.927Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ROBOGUIDE",
              "vendor": "FANUC",
              "versions": [
                {
                  "lessThan": "v9.40083.00.05 (Rev T)",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-04-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to a network-based attack by threat actors utilizing crafted naming conventions of files to gain unauthorized access rights."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-20T15:30:31.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-04-19T21:16:00.000Z",
              "ID": "CVE-2021-43988",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ROBOGUIDE",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "v9.40083.00.05 (Rev T)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "FANUC"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to a network-based attack by threat actors utilizing crafted naming conventions of files to gain unauthorized access rights."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43988",
        "datePublished": "2022-04-20T15:30:31.734Z",
        "dateReserved": "2021-11-17T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:28:37.927Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43933 (GCVE-0-2021-43933)

    Vulnerability from cvelistv5 – Published: 2022-04-20 15:30 – Updated: 2025-04-16 16:28
    VLAI
    Title
    ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform
    Summary
    The affected product is vulnerable to a network-based attack by threat actors sending unimpeded requests to the receiving server, which could cause a denial-of-service condition due to lack of heap memory resources.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    References
    Impacted products
    Vendor Product Version
    FANUC ROBOGUIDE Affected: All , < v9.40083.00.05 (Rev T) (custom)
    Create a notification for this product.
    Date Public
    2022-04-19 00:00
    Credits
    Sharon Brizinov with Claroty reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:17.020Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43933",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:41.984140Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:28:45.372Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ROBOGUIDE",
              "vendor": "FANUC",
              "versions": [
                {
                  "lessThan": "v9.40083.00.05 (Rev T)",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-04-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to a network-based attack by threat actors sending unimpeded requests to the receiving server, which could cause a denial-of-service condition due to lack of heap memory resources."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400 Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-20T15:30:30.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-04-19T21:16:00.000Z",
              "ID": "CVE-2021-43933",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ROBOGUIDE",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "v9.40083.00.05 (Rev T)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "FANUC"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to a network-based attack by threat actors sending unimpeded requests to the receiving server, which could cause a denial-of-service condition due to lack of heap memory resources."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-400 Uncontrolled Resource Consumption"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43933",
        "datePublished": "2022-04-20T15:30:30.872Z",
        "dateReserved": "2021-11-16T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:28:45.372Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-38483 (GCVE-0-2021-38483)

    Vulnerability from cvelistv5 – Published: 2022-04-20 15:30 – Updated: 2025-04-16 16:28
    VLAI
    Title
    ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform
    Summary
    The affected product is vulnerable to misconfigured binaries, allowing users on the target PC with SYSTEM level privileges access to overwrite the binary and modify files to gain privilege escalation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    References
    Impacted products
    Vendor Product Version
    FANUC ROBOGUIDE Affected: All , < v9.40083.00.05 (Rev T) (custom)
    Create a notification for this product.
    Date Public
    2022-04-19 00:00
    Credits
    Sharon Brizinov with Claroty reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:44:22.805Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-38483",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:46.426654Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:28:52.540Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ROBOGUIDE",
              "vendor": "FANUC",
              "versions": [
                {
                  "lessThan": "v9.40083.00.05 (Rev T)",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-04-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to misconfigured binaries, allowing users on the target PC with SYSTEM level privileges access to overwrite the binary and modify files to gain privilege escalation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-20T15:30:30.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-04-19T21:16:00.000Z",
              "ID": "CVE-2021-38483",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ROBOGUIDE",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "v9.40083.00.05 (Rev T)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "FANUC"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to misconfigured binaries, allowing users on the target PC with SYSTEM level privileges access to overwrite the binary and modify files to gain privilege escalation."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-732 Incorrect Permission Assignment for Critical Resource"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-38483",
        "datePublished": "2022-04-20T15:30:30.126Z",
        "dateReserved": "2021-08-10T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:28:52.540Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43986 (GCVE-0-2021-43986)

    Vulnerability from cvelistv5 – Published: 2022-04-20 15:30 – Updated: 2025-04-16 16:29
    VLAI
    Title
    ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform
    Summary
    The setup program for the affected product configures its files and folders with full access, which may allow unauthorized users permission to replace original binaries and achieve privilege escalation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    FANUC ROBOGUIDE Affected: All , < v9.40083.00.05 (Rev T) (custom)
    Create a notification for this product.
    Date Public
    2022-04-19 00:00
    Credits
    Sharon Brizinov with Claroty reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:16.964Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43986",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:49.356686Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:29:00.294Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ROBOGUIDE",
              "vendor": "FANUC",
              "versions": [
                {
                  "lessThan": "v9.40083.00.05 (Rev T)",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-04-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The setup program for the affected product configures its files and folders with full access, which may allow unauthorized users permission to replace original binaries and achieve privilege escalation."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-20T15:30:29.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-04-19T21:16:00.000Z",
              "ID": "CVE-2021-43986",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ROBOGUIDE",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "v9.40083.00.05 (Rev T)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "FANUC"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The setup program for the affected product configures its files and folders with full access, which may allow unauthorized users permission to replace original binaries and achieve privilege escalation."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-284 Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43986",
        "datePublished": "2022-04-20T15:30:29.227Z",
        "dateReserved": "2021-11-17T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:29:00.294Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-43990 (GCVE-0-2021-43990)

    Vulnerability from cvelistv5 – Published: 2022-04-20 15:30 – Updated: 2025-04-16 16:29
    VLAI
    Title
    ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform
    Summary
    The affected product is vulnerable to a network-based attack by threat actors supplying a crafted, malicious XML payload designed to trigger an external entity reference call.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
    Assigner
    References
    Impacted products
    Vendor Product Version
    FANUC ROBOGUIDE Affected: All , < v9.40083.00.05 (Rev T) (custom)
    Create a notification for this product.
    Date Public
    2022-04-19 00:00
    Credits
    Sharon Brizinov with Claroty reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T04:10:16.950Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-43990",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:53:53.308160Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:29:08.202Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ROBOGUIDE",
              "vendor": "FANUC",
              "versions": [
                {
                  "lessThan": "v9.40083.00.05 (Rev T)",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2022-04-19T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The affected product is vulnerable to a network-based attack by threat actors supplying a crafted, malicious XML payload designed to trigger an external entity reference call."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-20T15:30:28.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
            }
          ],
          "source": {
            "advisory": "ICSA-22-109-03",
            "discovery": "EXTERNAL"
          },
          "title": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-04-19T21:16:00.000Z",
              "ID": "CVE-2021-43990",
              "STATE": "PUBLIC",
              "TITLE": "ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "ROBOGUIDE",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "v9.40083.00.05 (Rev T)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "FANUC"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Sharon Brizinov with Claroty reported these vulnerabilities to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The affected product is vulnerable to a network-based attack by threat actors supplying a crafted, malicious XML payload designed to trigger an external entity reference call."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-109-03"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "FANUC has created a new version to address these vulnerabilities. Users may obtain and install the new version by downloading ROBOGUIDE v9 Rev U or higher from the FANUC or FANUC America website (login required)."
              }
            ],
            "source": {
              "advisory": "ICSA-22-109-03",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-43990",
        "datePublished": "2022-04-20T15:30:28.424Z",
        "dateReserved": "2021-11-17T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:29:08.202Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }