CVE-2023-46144 (GCVE-0-2023-46144)
Vulnerability from nvd – Published: 2023-12-14 14:08 – Updated: 2024-10-01 06:18
VLAI
Title
PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check
Summary
A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.
Severity
6.5 (Medium)
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1502 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1522 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | PLCnext Engineer |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072R |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , ≤ 2024.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.934Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1502",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PLCnext Engineer",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
}
],
"value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-01T06:18:18.730Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"source": {
"advisory": "VDE-2023-058",
"defect": [
"CERT@VDE#64611"
],
"discovery": "EXTERNAL"
},
"title": "PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46144",
"datePublished": "2023-12-14T14:08:07.244Z",
"dateReserved": "2023-10-17T07:04:03.577Z",
"dateUpdated": "2024-10-01T06:18:18.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46142 (GCVE-0-2023-46142)
Vulnerability from nvd – Published: 2023-12-14 14:05 – Updated: 2024-08-02 20:37
VLAI
Title
PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control
Summary
A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.
Severity
8.8 (High)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1502 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1522 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | PLCnext Engineer |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072R |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , ≤ 2024.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.840Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1502",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PLCnext Engineer",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
}
],
"value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T14:05:35.741Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"source": {
"advisory": "VDE-2023-056",
"defect": [
"CERT@VDE#64609"
],
"discovery": "EXTERNAL"
},
"title": "PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46142",
"datePublished": "2023-12-14T14:05:35.741Z",
"dateReserved": "2023-10-17T07:04:03.576Z",
"dateUpdated": "2024-08-02T20:37:39.840Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34570 (GCVE-0-2021-34570)
Vulnerability from nvd – Published: 2021-09-27 08:25 – Updated: 2024-09-16 22:09
VLAI
Title
Phoenix Contact: DoS for PLCnext Control devices in versions prior to 2021.0.5 LTS
Summary
Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests.
Severity
7.5 (High)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert.vde.com/en/advisories/VDE-2021-029/ | x_refsource_CONFIRM |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Phoenix Contact | AXC F |
Affected:
AXC F 1152 (1151412) , < 2021.0.5 LTS
(custom)
Affected: AXC F 2152 (2404267) , < 2021.0.5 LTS (custom) Affected: AXC F 3152 (1069208) , < 2021.0.5 LTS (custom) Affected: AXC F 2152 Starterkit (1046568) , < 2021.0.5 LTS (custom) |
|
| Phoenix Contact | RFC |
Affected:
RFC 4072S (1051328) , < 2021.0.5 LTS
(custom)
|
|
| Phoenix Contact | PLCnext |
Affected:
PLCnext Technology Starterkit (1188165) , < 2021.0.5 LTS
(custom)
|
Date Public
2021-08-03 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.435Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-029/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AXC F",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2021.0.5 LTS",
"status": "affected",
"version": "AXC F 1152 (1151412)",
"versionType": "custom"
},
{
"lessThan": "2021.0.5 LTS",
"status": "affected",
"version": "AXC F 2152 (2404267)",
"versionType": "custom"
},
{
"lessThan": "2021.0.5 LTS",
"status": "affected",
"version": "AXC F 3152 (1069208)",
"versionType": "custom"
},
{
"lessThan": "2021.0.5 LTS",
"status": "affected",
"version": "AXC F 2152 Starterkit (1046568)",
"versionType": "custom"
}
]
},
{
"product": "RFC",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2021.0.5 LTS",
"status": "affected",
"version": "RFC 4072S (1051328)",
"versionType": "custom"
}
]
},
{
"product": "PLCnext",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2021.0.5 LTS",
"status": "affected",
"version": "PLCnext Technology Starterkit (1188165)",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "The vulnerability was discovered by Oliver Carrigan of Dionach. We kindly appreciate the coordinated disclosure of these vulnerabilities by the finder. PHOENIX CONTACT thanks CERT@VDE for the coordination and support with this publication."
}
],
"datePublic": "2021-08-03T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-27T08:25:09.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-029/"
}
],
"solutions": [
{
"lang": "en",
"value": "Phoenix Contact recommends affected users to upgrade to the current Firmware 2021.0.5 LTS or higher which fixes this vulnerability."
}
],
"source": {
"advisory": "VDE-2021-029",
"discovery": "EXTERNAL"
},
"title": "Phoenix Contact: DoS for PLCnext Control devices in versions prior to 2021.0.5 LTS",
"workarounds": [
{
"lang": "en",
"value": "Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our application note:\nMeasures to protect network-capable devices with Ethernet connection"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-08-03T22:00:00.000Z",
"ID": "CVE-2021-34570",
"STATE": "PUBLIC",
"TITLE": "Phoenix Contact: DoS for PLCnext Control devices in versions prior to 2021.0.5 LTS"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AXC F",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "AXC F 1152 (1151412)",
"version_value": "2021.0.5 LTS"
},
{
"version_affected": "\u003c",
"version_name": "AXC F 2152 (2404267)",
"version_value": "2021.0.5 LTS"
},
{
"version_affected": "\u003c",
"version_name": "AXC F 3152 (1069208)",
"version_value": "2021.0.5 LTS"
},
{
"version_affected": "\u003c",
"version_name": "AXC F 2152 Starterkit (1046568)",
"version_value": "2021.0.5 LTS"
}
]
}
},
{
"product_name": "RFC",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "RFC 4072S (1051328)",
"version_value": "2021.0.5 LTS"
}
]
}
},
{
"product_name": "PLCnext",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "PLCnext Technology Starterkit (1188165)",
"version_value": "2021.0.5 LTS"
}
]
}
}
]
},
"vendor_name": "Phoenix Contact"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "The vulnerability was discovered by Oliver Carrigan of Dionach. We kindly appreciate the coordinated disclosure of these vulnerabilities by the finder. PHOENIX CONTACT thanks CERT@VDE for the coordination and support with this publication."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2021-029/",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2021-029/"
}
]
},
"solution": [
{
"lang": "en",
"value": "Phoenix Contact recommends affected users to upgrade to the current Firmware 2021.0.5 LTS or higher which fixes this vulnerability."
}
],
"source": {
"advisory": "VDE-2021-029",
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our application note:\nMeasures to protect network-capable devices with Ethernet connection"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34570",
"datePublished": "2021-09-27T08:25:09.502Z",
"dateReserved": "2021-06-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:09:31.616Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46144 (GCVE-0-2023-46144)
Vulnerability from cvelistv5 – Published: 2023-12-14 14:08 – Updated: 2024-10-01 06:18
VLAI
Title
PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check
Summary
A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.
Severity
6.5 (Medium)
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1502 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1522 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | PLCnext Engineer |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072R |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , ≤ 2024.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.934Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1502",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PLCnext Engineer",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
}
],
"value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-01T06:18:18.730Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"source": {
"advisory": "VDE-2023-058",
"defect": [
"CERT@VDE#64611"
],
"discovery": "EXTERNAL"
},
"title": "PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46144",
"datePublished": "2023-12-14T14:08:07.244Z",
"dateReserved": "2023-10-17T07:04:03.577Z",
"dateUpdated": "2024-10-01T06:18:18.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46142 (GCVE-0-2023-46142)
Vulnerability from cvelistv5 – Published: 2023-12-14 14:05 – Updated: 2024-08-02 20:37
VLAI
Title
PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control
Summary
A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.
Severity
8.8 (High)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
1 reference
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1502 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1522 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | PLCnext Engineer |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072R |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , ≤ 2024.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.840Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1502",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PLCnext Engineer",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
}
],
"value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T14:05:35.741Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"source": {
"advisory": "VDE-2023-056",
"defect": [
"CERT@VDE#64609"
],
"discovery": "EXTERNAL"
},
"title": "PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46142",
"datePublished": "2023-12-14T14:05:35.741Z",
"dateReserved": "2023-10-17T07:04:03.576Z",
"dateUpdated": "2024-08-02T20:37:39.840Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34570 (GCVE-0-2021-34570)
Vulnerability from cvelistv5 – Published: 2021-09-27 08:25 – Updated: 2024-09-16 22:09
VLAI
Title
Phoenix Contact: DoS for PLCnext Control devices in versions prior to 2021.0.5 LTS
Summary
Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests.
Severity
7.5 (High)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert.vde.com/en/advisories/VDE-2021-029/ | x_refsource_CONFIRM |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Phoenix Contact | AXC F |
Affected:
AXC F 1152 (1151412) , < 2021.0.5 LTS
(custom)
Affected: AXC F 2152 (2404267) , < 2021.0.5 LTS (custom) Affected: AXC F 3152 (1069208) , < 2021.0.5 LTS (custom) Affected: AXC F 2152 Starterkit (1046568) , < 2021.0.5 LTS (custom) |
|
| Phoenix Contact | RFC |
Affected:
RFC 4072S (1051328) , < 2021.0.5 LTS
(custom)
|
|
| Phoenix Contact | PLCnext |
Affected:
PLCnext Technology Starterkit (1188165) , < 2021.0.5 LTS
(custom)
|
Date Public
2021-08-03 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:12:50.435Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-029/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AXC F",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2021.0.5 LTS",
"status": "affected",
"version": "AXC F 1152 (1151412)",
"versionType": "custom"
},
{
"lessThan": "2021.0.5 LTS",
"status": "affected",
"version": "AXC F 2152 (2404267)",
"versionType": "custom"
},
{
"lessThan": "2021.0.5 LTS",
"status": "affected",
"version": "AXC F 3152 (1069208)",
"versionType": "custom"
},
{
"lessThan": "2021.0.5 LTS",
"status": "affected",
"version": "AXC F 2152 Starterkit (1046568)",
"versionType": "custom"
}
]
},
{
"product": "RFC",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2021.0.5 LTS",
"status": "affected",
"version": "RFC 4072S (1051328)",
"versionType": "custom"
}
]
},
{
"product": "PLCnext",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2021.0.5 LTS",
"status": "affected",
"version": "PLCnext Technology Starterkit (1188165)",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "The vulnerability was discovered by Oliver Carrigan of Dionach. We kindly appreciate the coordinated disclosure of these vulnerabilities by the finder. PHOENIX CONTACT thanks CERT@VDE for the coordination and support with this publication."
}
],
"datePublic": "2021-08-03T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-27T08:25:09.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-029/"
}
],
"solutions": [
{
"lang": "en",
"value": "Phoenix Contact recommends affected users to upgrade to the current Firmware 2021.0.5 LTS or higher which fixes this vulnerability."
}
],
"source": {
"advisory": "VDE-2021-029",
"discovery": "EXTERNAL"
},
"title": "Phoenix Contact: DoS for PLCnext Control devices in versions prior to 2021.0.5 LTS",
"workarounds": [
{
"lang": "en",
"value": "Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our application note:\nMeasures to protect network-capable devices with Ethernet connection"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2021-08-03T22:00:00.000Z",
"ID": "CVE-2021-34570",
"STATE": "PUBLIC",
"TITLE": "Phoenix Contact: DoS for PLCnext Control devices in versions prior to 2021.0.5 LTS"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AXC F",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "AXC F 1152 (1151412)",
"version_value": "2021.0.5 LTS"
},
{
"version_affected": "\u003c",
"version_name": "AXC F 2152 (2404267)",
"version_value": "2021.0.5 LTS"
},
{
"version_affected": "\u003c",
"version_name": "AXC F 3152 (1069208)",
"version_value": "2021.0.5 LTS"
},
{
"version_affected": "\u003c",
"version_name": "AXC F 2152 Starterkit (1046568)",
"version_value": "2021.0.5 LTS"
}
]
}
},
{
"product_name": "RFC",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "RFC 4072S (1051328)",
"version_value": "2021.0.5 LTS"
}
]
}
},
{
"product_name": "PLCnext",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "PLCnext Technology Starterkit (1188165)",
"version_value": "2021.0.5 LTS"
}
]
}
}
]
},
"vendor_name": "Phoenix Contact"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "The vulnerability was discovered by Oliver Carrigan of Dionach. We kindly appreciate the coordinated disclosure of these vulnerabilities by the finder. PHOENIX CONTACT thanks CERT@VDE for the coordination and support with this publication."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple Phoenix Contact PLCnext control devices in versions prior to 2021.0.5 LTS are prone to a DoS attack through special crafted JSON requests."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2021-029/",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2021-029/"
}
]
},
"solution": [
{
"lang": "en",
"value": "Phoenix Contact recommends affected users to upgrade to the current Firmware 2021.0.5 LTS or higher which fixes this vulnerability."
}
],
"source": {
"advisory": "VDE-2021-029",
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Phoenix Contact recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our application note:\nMeasures to protect network-capable devices with Ethernet connection"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34570",
"datePublished": "2021-09-27T08:25:09.502Z",
"dateReserved": "2021-06-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:09:31.616Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}