    CVE-2020-6995 (GCVE-0-2020-6995)

    Vulnerability from nvd – Published: 2020-03-24 19:16 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the application utilizes weak password requirements, which may allow an attacker to gain unauthorized access.
    Severity
    No CVSS data available.
    CWE
    • CWE-521 - WEAK PASSWORD REQUIREMENTS CWE-521
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:03.026Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the application utilizes weak password requirements, which may allow an attacker to gain unauthorized access."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-521",
                  "description": "WEAK PASSWORD REQUIREMENTS CWE-521",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-24T19:16:16.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6995",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the application utilizes weak password requirements, which may allow an attacker to gain unauthorized access."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "WEAK PASSWORD REQUIREMENTS CWE-521"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6995",
        "datePublished": "2020-03-24T19:16:16.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:03.026Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6993 (GCVE-0-2020-6993)

    Vulnerability from nvd – Published: 2020-03-24 19:19 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, an attacker can gain access to sensitive information from the web service without authorization.
    Severity
    No CVSS data available.
    CWE
    • CWE-200 - INFORMATION EXPOSURE CWE-200
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:02.970Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, an attacker can gain access to sensitive information from the web service without authorization."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "INFORMATION EXPOSURE CWE-200",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-24T19:19:09.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6993",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, an attacker can gain access to sensitive information from the web service without authorization."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "INFORMATION EXPOSURE CWE-200"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6993",
        "datePublished": "2020-03-24T19:19:09.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:02.970Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6985 (GCVE-0-2020-6985)

    Vulnerability from nvd – Published: 2020-03-24 19:11 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console.
    Severity
    No CVSS data available.
    CWE
    • CWE-798 - USE OF HARD-CODED CREDENTIALS CWE-798
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:02.996Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "USE OF HARD-CODED CREDENTIALS CWE-798",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-24T19:11:40.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6985",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "USE OF HARD-CODED CREDENTIALS CWE-798"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6985",
        "datePublished": "2020-03-24T19:11:40.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:02.996Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6989 (GCVE-0-2020-6989)

    Vulnerability from nvd – Published: 2020-03-24 18:54 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:02.547Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-24T18:54:19.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6989",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6989",
        "datePublished": "2020-03-24T18:54:19.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:02.547Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6987 (GCVE-0-2020-6987)

    Vulnerability from nvd – Published: 2020-03-24 19:00 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed.
    Severity
    No CVSS data available.
    CWE
    • CWE-327 - USE OF A BROKEN OR RISKY CRYPTOGRAPHIC ALGORITHM CWE-327
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:02.493Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-327",
                  "description": "USE OF A BROKEN OR RISKY CRYPTOGRAPHIC ALGORITHM CWE-327",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-24T19:00:16.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6987",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "USE OF A BROKEN OR RISKY CRYPTOGRAPHIC ALGORITHM CWE-327"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6987",
        "datePublished": "2020-03-24T19:00:16.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:02.493Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6983 (GCVE-0-2020-6983)

    Vulnerability from nvd – Published: 2020-03-24 18:57 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered.
    Severity
    No CVSS data available.
    CWE
    • CWE-321 - USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:02.537Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-24T18:57:14.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6983",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6983",
        "datePublished": "2020-03-24T18:57:14.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:02.537Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6993 (GCVE-0-2020-6993)

    Vulnerability from cvelistv5 – Published: 2020-03-24 19:19 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, an attacker can gain access to sensitive information from the web service without authorization.
    Severity
    No CVSS data available.
    CWE
    • CWE-200 - INFORMATION EXPOSURE CWE-200
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:02.970Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, an attacker can gain access to sensitive information from the web service without authorization."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "INFORMATION EXPOSURE CWE-200",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-24T19:19:09.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6993",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, an attacker can gain access to sensitive information from the web service without authorization."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "INFORMATION EXPOSURE CWE-200"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6993",
        "datePublished": "2020-03-24T19:19:09.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:02.970Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6995 (GCVE-0-2020-6995)

    Vulnerability from cvelistv5 – Published: 2020-03-24 19:16 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the application utilizes weak password requirements, which may allow an attacker to gain unauthorized access.
    Severity
    No CVSS data available.
    CWE
    • CWE-521 - WEAK PASSWORD REQUIREMENTS CWE-521
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:03.026Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the application utilizes weak password requirements, which may allow an attacker to gain unauthorized access."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-521",
                  "description": "WEAK PASSWORD REQUIREMENTS CWE-521",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-24T19:16:16.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6995",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the application utilizes weak password requirements, which may allow an attacker to gain unauthorized access."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "WEAK PASSWORD REQUIREMENTS CWE-521"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6995",
        "datePublished": "2020-03-24T19:16:16.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:03.026Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6985 (GCVE-0-2020-6985)

    Vulnerability from cvelistv5 – Published: 2020-03-24 19:11 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console.
    Severity
    No CVSS data available.
    CWE
    • CWE-798 - USE OF HARD-CODED CREDENTIALS CWE-798
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:02.996Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "USE OF HARD-CODED CREDENTIALS CWE-798",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-24T19:11:40.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6985",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "USE OF HARD-CODED CREDENTIALS CWE-798"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6985",
        "datePublished": "2020-03-24T19:11:40.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:02.996Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6987 (GCVE-0-2020-6987)

    Vulnerability from cvelistv5 – Published: 2020-03-24 19:00 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed.
    Severity
    No CVSS data available.
    CWE
    • CWE-327 - USE OF A BROKEN OR RISKY CRYPTOGRAPHIC ALGORITHM CWE-327
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:02.493Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-327",
                  "description": "USE OF A BROKEN OR RISKY CRYPTOGRAPHIC ALGORITHM CWE-327",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-24T19:00:16.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6987",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "USE OF A BROKEN OR RISKY CRYPTOGRAPHIC ALGORITHM CWE-327"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6987",
        "datePublished": "2020-03-24T19:00:16.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:02.493Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6983 (GCVE-0-2020-6983)

    Vulnerability from cvelistv5 – Published: 2020-03-24 18:57 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered.
    Severity
    No CVSS data available.
    CWE
    • CWE-321 - USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:02.537Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-24T18:57:14.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6983",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6983",
        "datePublished": "2020-03-24T18:57:14.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:02.537Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-6989 (GCVE-0-2020-6989)

    Vulnerability from cvelistv5 – Published: 2020-03-24 18:54 – Updated: 2024-08-04 09:18
    VLAI
    Summary
    In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:18:02.547Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-03-24T18:54:19.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-6989",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-6989",
        "datePublished": "2020-03-24T18:54:19.000Z",
        "dateReserved": "2020-01-14T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:18:02.547Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }