Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for power_manager by schneider-electric

    CVE-2020-7547 (GCVE-0-2020-7547)

    Vulnerability from nvd – Published: 2020-12-01 14:44 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level.
    Severity
    No CVSS data available.
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) Affected: EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.887Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-284: Improper Access Control vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284:Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-01T14:44:52.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7547",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-284: Improper Access Control vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-284:Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7547",
        "datePublished": "2020-12-01T14:44:52.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.887Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7546 (GCVE-0-2020-7546)

    Vulnerability from nvd – Published: 2020-12-01 14:44 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage.
    Severity
    No CVSS data available.
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) Affected: EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.932Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-01T14:44:31.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7546",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79: Improper Neutralization of Input During Web Page Generation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7546",
        "datePublished": "2020-12-01T14:44:31.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7545 (GCVE-0-2020-7545)

    Vulnerability from nvd – Published: 2020-12-01 14:44 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage.
    Severity
    No CVSS data available.
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) Affected: EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.761Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-284:Improper Access Control vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284:Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-01T14:44:10.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7545",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-284:Improper Access Control vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-284:Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7545",
        "datePublished": "2020-12-01T14:44:10.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.761Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7547 (GCVE-0-2020-7547)

    Vulnerability from cvelistv5 – Published: 2020-12-01 14:44 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level.
    Severity
    No CVSS data available.
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) Affected: EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.887Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-284: Improper Access Control vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284:Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-01T14:44:52.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7547",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-284: Improper Access Control vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-284:Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7547",
        "datePublished": "2020-12-01T14:44:52.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.887Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7546 (GCVE-0-2020-7546)

    Vulnerability from cvelistv5 – Published: 2020-12-01 14:44 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage.
    Severity
    No CVSS data available.
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) Affected: EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.932Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-01T14:44:31.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7546",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79: Improper Neutralization of Input During Web Page Generation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7546",
        "datePublished": "2020-12-01T14:44:31.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7545 (GCVE-0-2020-7545)

    Vulnerability from cvelistv5 – Published: 2020-12-01 14:44 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage.
    Severity
    No CVSS data available.
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) Affected: EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.761Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-284:Improper Access Control vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284:Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-12-01T14:44:10.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7545",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A CWE-284:Improper Access Control vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected webpage."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-284:Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7545",
        "datePublished": "2020-12-01T14:44:10.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.761Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }