Search
Find a vulnerability
Search criteria
10 vulnerabilities found for o3v2_firmware by tenda
CVE-2024-7152 (GCVE-0-2024-7152)
Vulnerability from nvd – Published: 2024-07-27 21:00 – Updated: 2024-08-01 21:52
VLAI
EPSS
VEX
Title
Tenda O3 setMacFilterList fromSafeSetMacFilter stack-based overflow
Summary
A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272555. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-29 13:40 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.272555 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.272555 | signaturepermissions-required |
| https://vuldb.com/?submit.377041 | third-party-advisory |
| https://github.com/noahze01/IoT-vulnerable/blob/m… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | O3 |
Affected:
1.0.0.10(2478)
|
|
| tenda | o3v2_firmware |
Affected:
1.0.0.10
cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "o3v2_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7152",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-29T13:40:27.298550Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-29T17:01:59.426Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:52:30.746Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-272555 | Tenda O3 setMacFilterList fromSafeSetMacFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.272555"
},
{
"name": "VDB-272555 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.272555"
},
{
"name": "Submit #377041 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.377041"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/O3v2.0/fromSafeSetMacFilter.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "O3",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10(2478)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "noahze (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272555. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda O3 1.0.0.10(2478) ausgemacht. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion fromSafeSetMacFilter der Datei /goform/setMacFilterList. Durch Manipulieren des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-27T21:00:06.271Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-272555 | Tenda O3 setMacFilterList fromSafeSetMacFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.272555"
},
{
"name": "VDB-272555 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.272555"
},
{
"name": "Submit #377041 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.377041"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/O3v2.0/fromSafeSetMacFilter.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-07-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-07-27T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-07-27T07:51:42.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda O3 setMacFilterList fromSafeSetMacFilter stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7152",
"datePublished": "2024-07-27T21:00:06.271Z",
"dateReserved": "2024-07-27T05:46:29.296Z",
"dateUpdated": "2024-08-01T21:52:30.746Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7151 (GCVE-0-2024-7151)
Vulnerability from nvd – Published: 2024-07-27 20:00 – Updated: 2024-08-01 21:52
VLAI
EPSS
VEX
Title
Tenda O3 setMacFilter fromMacFilterSet stack-based overflow
Summary
A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been declared as critical. This vulnerability affects the function fromMacFilterSet of the file /goform/setMacFilter. The manipulation of the argument remark leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272554 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-28 10:59 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.272554 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.272554 | signaturepermissions-required |
| https://vuldb.com/?submit.377040 | third-party-advisory |
| https://github.com/noahze01/IoT-vulnerable/blob/m… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | O3 |
Affected:
1.0.0.10(2478)
|
|
| tenda | o3v2_firmware |
Affected:
1.0.0.10
cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "o3v2_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7151",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-28T10:59:04.716252Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-28T10:59:48.643Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:52:30.700Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-272554 | Tenda O3 setMacFilter fromMacFilterSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.272554"
},
{
"name": "VDB-272554 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.272554"
},
{
"name": "Submit #377040 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.377040"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/O3v2.0/fromMacFilterSet.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "O3",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10(2478)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "noahze (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been declared as critical. This vulnerability affects the function fromMacFilterSet of the file /goform/setMacFilter. The manipulation of the argument remark leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272554 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda O3 1.0.0.10(2478) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Hierbei betrifft es die Funktion fromMacFilterSet der Datei /goform/setMacFilter. Durch das Manipulieren des Arguments remark mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-27T20:00:05.233Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-272554 | Tenda O3 setMacFilter fromMacFilterSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.272554"
},
{
"name": "VDB-272554 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.272554"
},
{
"name": "Submit #377040 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.377040"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/O3v2.0/fromMacFilterSet.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-07-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-07-27T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-07-27T07:51:39.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda O3 setMacFilter fromMacFilterSet stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7151",
"datePublished": "2024-07-27T20:00:05.233Z",
"dateReserved": "2024-07-27T05:46:26.985Z",
"dateUpdated": "2024-08-01T21:52:30.700Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-6965 (GCVE-0-2024-6965)
Vulnerability from nvd – Published: 2024-07-22 01:31 – Updated: 2024-08-01 21:45
VLAI
EPSS
VEX
Title
Tenda O3 fromVirtualSet stack-based overflow
Summary
A vulnerability has been found in Tenda O3 1.0.0.10 and classified as critical. Affected by this vulnerability is the function fromVirtualSet. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272119. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-22 10:56 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.272119 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.272119 | signaturepermissions-required |
| https://vuldb.com/?submit.374586 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:o3v2:1.0.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "o3v2",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "o3v2_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6965",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-22T10:56:26.180564Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-23T14:47:49.168Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:45:38.398Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-272119 | Tenda O3 fromVirtualSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.272119"
},
{
"name": "VDB-272119 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.272119"
},
{
"name": "Submit #374586 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.374586"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/O3V2.0/fromVirtualSet.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "O3",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda O3 1.0.0.10 and classified as critical. Affected by this vulnerability is the function fromVirtualSet. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272119. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda O3 1.0.0.10 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Hierbei betrifft es die Funktion fromVirtualSet. Dank Manipulation des Arguments ip/localPort/publicPort/app mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-22T01:31:04.351Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-272119 | Tenda O3 fromVirtualSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.272119"
},
{
"name": "VDB-272119 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.272119"
},
{
"name": "Submit #374586 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.374586"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/O3V2.0/fromVirtualSet.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-07-21T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-07-21T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-07-21T15:32:44.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda O3 fromVirtualSet stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-6965",
"datePublished": "2024-07-22T01:31:04.351Z",
"dateReserved": "2024-07-21T13:27:33.680Z",
"dateUpdated": "2024-08-01T21:45:38.398Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-6963 (GCVE-0-2024-6963)
Vulnerability from nvd – Published: 2024-07-22 00:00 – Updated: 2024-08-01 21:45
VLAI
EPSS
VEX
Title
Tenda O3 formexeCommand stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda O3 1.0.0.10. This issue affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272117 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-23 14:34 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.272117 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.272117 | signaturepermissions-required |
| https://vuldb.com/?submit.374584 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | O3 |
Affected:
1.0.0.10
|
|
| tenda | o3v2_firmware |
Affected:
1.0.0.10
cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "o3v2_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6963",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-23T14:34:44.883901Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-24T18:41:26.985Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:45:38.332Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-272117 | Tenda O3 formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.272117"
},
{
"name": "VDB-272117 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.272117"
},
{
"name": "Submit #374584 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.374584"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/O3V2.0/formexeCommand.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "O3",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda O3 1.0.0.10. This issue affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272117 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda O3 1.0.0.10 entdeckt. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formexeCommand. Durch Beeinflussen des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-22T00:00:07.045Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-272117 | Tenda O3 formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.272117"
},
{
"name": "VDB-272117 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.272117"
},
{
"name": "Submit #374584 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.374584"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/O3V2.0/formexeCommand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-07-21T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-07-21T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-07-21T15:32:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda O3 formexeCommand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-6963",
"datePublished": "2024-07-22T00:00:07.045Z",
"dateReserved": "2024-07-21T13:27:27.894Z",
"dateUpdated": "2024-08-01T21:45:38.332Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-36604 (GCVE-0-2024-36604)
Vulnerability from nvd – Published: 2024-06-04 17:14 – Updated: 2025-02-13 15:59
VLAI
EPSS
VEX
Summary
Tenda O3V2 v1.0.0.12(3880) was discovered to contain a Blind Command Injection via stpEn parameter in the SetStp function. This vulnerability allows attackers to execute arbitrary commands with root privileges.
Severity
9.8 (Critical)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-15 18:08 UTC
CWE
- n/a
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | o3v2_firmware |
Affected:
1.0.0.12\(3880\)
cpe:2.3:o:tenda:o3v2_firmware:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T03:37:05.347Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://exzettabyte.me/blind-command-injection-in-stp-service-on-tenda-o3v2/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:o3v2_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "o3v2_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.12\\(3880\\)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-36604",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-15T18:08:58.466315Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-15T18:14:52.383Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda O3V2 v1.0.0.12(3880) was discovered to contain a Blind Command Injection via stpEn parameter in the SetStp function. This vulnerability allows attackers to execute arbitrary commands with root privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:14:09.007Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://exzettabyte.me/blind-command-injection-in-stp-service-on-tenda-o3v2/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-36604",
"datePublished": "2024-06-04T17:14:08.675Z",
"dateReserved": "2024-05-30T00:00:00.000Z",
"dateUpdated": "2025-02-13T15:59:25.200Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7152 (GCVE-0-2024-7152)
Vulnerability from cvelistv5 – Published: 2024-07-27 21:00 – Updated: 2024-08-01 21:52
VLAI
EPSS
VEX
Title
Tenda O3 setMacFilterList fromSafeSetMacFilter stack-based overflow
Summary
A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272555. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-29 13:40 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.272555 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.272555 | signaturepermissions-required |
| https://vuldb.com/?submit.377041 | third-party-advisory |
| https://github.com/noahze01/IoT-vulnerable/blob/m… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | O3 |
Affected:
1.0.0.10(2478)
|
|
| tenda | o3v2_firmware |
Affected:
1.0.0.10
cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "o3v2_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7152",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-29T13:40:27.298550Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-29T17:01:59.426Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:52:30.746Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-272555 | Tenda O3 setMacFilterList fromSafeSetMacFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.272555"
},
{
"name": "VDB-272555 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.272555"
},
{
"name": "Submit #377041 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.377041"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/O3v2.0/fromSafeSetMacFilter.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "O3",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10(2478)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "noahze (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been rated as critical. This issue affects the function fromSafeSetMacFilter of the file /goform/setMacFilterList. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272555. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda O3 1.0.0.10(2478) ausgemacht. Sie wurde als kritisch eingestuft. Davon betroffen ist die Funktion fromSafeSetMacFilter der Datei /goform/setMacFilterList. Durch Manipulieren des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-27T21:00:06.271Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-272555 | Tenda O3 setMacFilterList fromSafeSetMacFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.272555"
},
{
"name": "VDB-272555 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.272555"
},
{
"name": "Submit #377041 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.377041"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/O3v2.0/fromSafeSetMacFilter.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-07-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-07-27T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-07-27T07:51:42.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda O3 setMacFilterList fromSafeSetMacFilter stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7152",
"datePublished": "2024-07-27T21:00:06.271Z",
"dateReserved": "2024-07-27T05:46:29.296Z",
"dateUpdated": "2024-08-01T21:52:30.746Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7151 (GCVE-0-2024-7151)
Vulnerability from cvelistv5 – Published: 2024-07-27 20:00 – Updated: 2024-08-01 21:52
VLAI
EPSS
VEX
Title
Tenda O3 setMacFilter fromMacFilterSet stack-based overflow
Summary
A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been declared as critical. This vulnerability affects the function fromMacFilterSet of the file /goform/setMacFilter. The manipulation of the argument remark leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272554 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-28 10:59 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.272554 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.272554 | signaturepermissions-required |
| https://vuldb.com/?submit.377040 | third-party-advisory |
| https://github.com/noahze01/IoT-vulnerable/blob/m… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | O3 |
Affected:
1.0.0.10(2478)
|
|
| tenda | o3v2_firmware |
Affected:
1.0.0.10
cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "o3v2_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7151",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-28T10:59:04.716252Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-28T10:59:48.643Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:52:30.700Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-272554 | Tenda O3 setMacFilter fromMacFilterSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.272554"
},
{
"name": "VDB-272554 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.272554"
},
{
"name": "Submit #377040 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.377040"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/O3v2.0/fromMacFilterSet.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "O3",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10(2478)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "noahze (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been declared as critical. This vulnerability affects the function fromMacFilterSet of the file /goform/setMacFilter. The manipulation of the argument remark leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272554 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda O3 1.0.0.10(2478) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Hierbei betrifft es die Funktion fromMacFilterSet der Datei /goform/setMacFilter. Durch das Manipulieren des Arguments remark mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-27T20:00:05.233Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-272554 | Tenda O3 setMacFilter fromMacFilterSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.272554"
},
{
"name": "VDB-272554 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.272554"
},
{
"name": "Submit #377040 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.377040"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/noahze01/IoT-vulnerable/blob/main/Tenda/O3v2.0/fromMacFilterSet.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-07-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-07-27T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-07-27T07:51:39.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda O3 setMacFilter fromMacFilterSet stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-7151",
"datePublished": "2024-07-27T20:00:05.233Z",
"dateReserved": "2024-07-27T05:46:26.985Z",
"dateUpdated": "2024-08-01T21:52:30.700Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-6965 (GCVE-0-2024-6965)
Vulnerability from cvelistv5 – Published: 2024-07-22 01:31 – Updated: 2024-08-01 21:45
VLAI
EPSS
VEX
Title
Tenda O3 fromVirtualSet stack-based overflow
Summary
A vulnerability has been found in Tenda O3 1.0.0.10 and classified as critical. Affected by this vulnerability is the function fromVirtualSet. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272119. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-22 10:56 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.272119 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.272119 | signaturepermissions-required |
| https://vuldb.com/?submit.374586 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:o3v2:1.0.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "o3v2",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
},
{
"cpes": [
"cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "o3v2_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6965",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-22T10:56:26.180564Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-23T14:47:49.168Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:45:38.398Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-272119 | Tenda O3 fromVirtualSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.272119"
},
{
"name": "VDB-272119 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.272119"
},
{
"name": "Submit #374586 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.374586"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/O3V2.0/fromVirtualSet.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "O3",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda O3 1.0.0.10 and classified as critical. Affected by this vulnerability is the function fromVirtualSet. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272119. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda O3 1.0.0.10 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Hierbei betrifft es die Funktion fromVirtualSet. Dank Manipulation des Arguments ip/localPort/publicPort/app mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-22T01:31:04.351Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-272119 | Tenda O3 fromVirtualSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.272119"
},
{
"name": "VDB-272119 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.272119"
},
{
"name": "Submit #374586 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.374586"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/O3V2.0/fromVirtualSet.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-07-21T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-07-21T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-07-21T15:32:44.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda O3 fromVirtualSet stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-6965",
"datePublished": "2024-07-22T01:31:04.351Z",
"dateReserved": "2024-07-21T13:27:33.680Z",
"dateUpdated": "2024-08-01T21:45:38.398Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-6963 (GCVE-0-2024-6963)
Vulnerability from cvelistv5 – Published: 2024-07-22 00:00 – Updated: 2024-08-01 21:45
VLAI
EPSS
VEX
Title
Tenda O3 formexeCommand stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda O3 1.0.0.10. This issue affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272117 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-23 14:34 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.272117 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.272117 | signaturepermissions-required |
| https://vuldb.com/?submit.374584 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | O3 |
Affected:
1.0.0.10
|
|
| tenda | o3v2_firmware |
Affected:
1.0.0.10
cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:o3v2_firmware:1.0.0.10:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "o3v2_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6963",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-23T14:34:44.883901Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-24T18:41:26.985Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:45:38.332Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-272117 | Tenda O3 formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.272117"
},
{
"name": "VDB-272117 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.272117"
},
{
"name": "Submit #374584 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.374584"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/O3V2.0/formexeCommand.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "O3",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda O3 1.0.0.10. This issue affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272117 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda O3 1.0.0.10 entdeckt. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formexeCommand. Durch Beeinflussen des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-22T00:00:07.045Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-272117 | Tenda O3 formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.272117"
},
{
"name": "VDB-272117 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.272117"
},
{
"name": "Submit #374584 | Tenda O3V2.0 V1.0.0.10(2478) Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.374584"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/O3V2.0/formexeCommand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-07-21T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-07-21T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-07-21T15:32:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda O3 formexeCommand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-6963",
"datePublished": "2024-07-22T00:00:07.045Z",
"dateReserved": "2024-07-21T13:27:27.894Z",
"dateUpdated": "2024-08-01T21:45:38.332Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-36604 (GCVE-0-2024-36604)
Vulnerability from cvelistv5 – Published: 2024-06-04 17:14 – Updated: 2025-02-13 15:59
VLAI
EPSS
VEX
Summary
Tenda O3V2 v1.0.0.12(3880) was discovered to contain a Blind Command Injection via stpEn parameter in the SetStp function. This vulnerability allows attackers to execute arbitrary commands with root privileges.
Severity
9.8 (Critical)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-15 18:08 UTC
CWE
- n/a
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | o3v2_firmware |
Affected:
1.0.0.12\(3880\)
cpe:2.3:o:tenda:o3v2_firmware:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T03:37:05.347Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://exzettabyte.me/blind-command-injection-in-stp-service-on-tenda-o3v2/"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:o3v2_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "o3v2_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.0.12\\(3880\\)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-36604",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-15T18:08:58.466315Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-15T18:14:52.383Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda O3V2 v1.0.0.12(3880) was discovered to contain a Blind Command Injection via stpEn parameter in the SetStp function. This vulnerability allows attackers to execute arbitrary commands with root privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:14:09.007Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://exzettabyte.me/blind-command-injection-in-stp-service-on-tenda-o3v2/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-36604",
"datePublished": "2024-06-04T17:14:08.675Z",
"dateReserved": "2024-05-30T00:00:00.000Z",
"dateUpdated": "2025-02-13T15:59:25.200Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}