Search

Find a vulnerability

Search criteria

    81 vulnerabilities found for nr1800x_firmware by totolink

    FKIE_CVE-2025-60686

    Vulnerability from fkie_nvd - Published: 2025-11-13 16:15 - Updated: 2026-11-05 14:10
    Summary
    A local stack-based buffer overflow vulnerability exists in the infostat.cgi and cstecgi.cgi binaries of ToToLink routers (A720R V4.1.5cu.614_B20230630, LR1200GB V9.1.0u.6619_B20230130, and NR1800X V9.1.0u.6681_B20230703). Both programs parse the contents of /proc/net/arp using sscanf() with "%s" format specifiers into fixed-size stack buffers without length validation. Specifically, one function writes user-controlled data into a single-byte buffer, and the other into adjacent small arrays without bounds checking. An attacker who controls the contents of /proc/net/arp can trigger memory corruption, leading to denial of service or potential arbitrary code execution.
    Impacted products
    Vendor Product Version
    totolink a720r_firmware 4.1.5cu.614_b20230630
    totolink a720r -
    totolink lr1200gb_firmware 9.1.0u.6619_b20230130
    totolink lr1200gb -
    totolink nr1800x_firmware 9.1.0u.6681_b20230703
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:a720r_firmware:4.1.5cu.614_b20230630:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BCA249C9-68D4-48FE-B0CA-77ECF53DDE3B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:a720r:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A1DE5168-B787-462C-B024-2B8F73759034",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:lr1200gb_firmware:9.1.0u.6619_b20230130:*:*:*:*:*:*:*",
                  "matchCriteriaId": "00F36DE9-D043-4C8B-9EF9-8DA669589E85",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:lr1200gb:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8442849E-5B06-41A1-8DA8-827FBD7A34E5",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6681_b20230703:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F9DCAA5-1EC6-44A1-9606-B6FBF29DEC65",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A local stack-based buffer overflow vulnerability exists in the infostat.cgi and cstecgi.cgi binaries of ToToLink routers (A720R V4.1.5cu.614_B20230630, LR1200GB V9.1.0u.6619_B20230130, and NR1800X V9.1.0u.6681_B20230703). Both programs parse the contents of /proc/net/arp using sscanf() with \"%s\" format specifiers into fixed-size stack buffers without length validation. Specifically, one function writes user-controlled data into a single-byte buffer, and the other into adjacent small arrays without bounds checking. An attacker who controls the contents of /proc/net/arp can trigger memory corruption, leading to denial of service or potential arbitrary code execution."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad local de desbordamiento de b\u00fafer basado en pila existe en los binarios infostat.cgi y cstecgi.cgi de los routers ToToLink (A720R V4.1.5cu.614_B20230630, LR1200GB V9.1.0u.6619_B20230130, y NR1800X V9.1.0u.6681_B20230703). Ambos programas analizan el contenido de /proc/net/arp usando sscanf() con especificadores de formato \u2019%s\u2019 en b\u00faferes de pila de tama\u00f1o fijo sin validaci\u00f3n de longitud. Espec\u00edficamente, una funci\u00f3n escribe datos controlados por el usuario en un b\u00fafer de un solo byte, y la otra en peque\u00f1os arreglos adyacentes sin comprobaci\u00f3n de l\u00edmites. Un atacante que controla el contenido de /proc/net/arp puede desencadenar corrupci\u00f3n de memoria, lo que lleva a denegaci\u00f3n de servicio o potencial ejecuci\u00f3n de c\u00f3digo arbitrario."
        }
      ],
      "id": "CVE-2025-60686",
      "lastModified": "2026-11-05T14:10:00.273",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "LOW",
              "baseScore": 5.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 2.5,
            "impactScore": 2.5,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-60686",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-11-13T17:37:13.785364Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-11-13T16:15:52.590",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/yifan20020708/SGTaint-0-day/blob/main/ToToLink/ToToLink-A720R/CVE-2025-60686.md"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-60684

    Vulnerability from fkie_nvd - Published: 2025-11-13 16:15 - Updated: 2026-11-05 14:10
    Summary
    A stack buffer overflow vulnerability exists in the ToToLink LR1200GB (V9.1.0u.6619_B20230130) and NR1800X (V9.1.0u.6681_B20230703) Router firmware within the cstecgi.cgi binary (sub_42F32C function). The web interface reads the "lang" parameter and constructs Help URL strings using sprintf() into fixed-size stack buffers without proper length validation. Maliciously crafted input can overflow these buffers, potentially leading to arbitrary code execution or memory corruption, without requiring authentication.
    Impacted products
    Vendor Product Version
    totolink lr1200gb_firmware 9.1.0u.6619_b20230130
    totolink lr1200gb -
    totolink nr1800x_firmware 9.1.0u.6681_b20230703
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:lr1200gb_firmware:9.1.0u.6619_b20230130:*:*:*:*:*:*:*",
                  "matchCriteriaId": "00F36DE9-D043-4C8B-9EF9-8DA669589E85",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:lr1200gb:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8442849E-5B06-41A1-8DA8-827FBD7A34E5",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6681_b20230703:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F9DCAA5-1EC6-44A1-9606-B6FBF29DEC65",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A stack buffer overflow vulnerability exists in the ToToLink LR1200GB (V9.1.0u.6619_B20230130) and NR1800X (V9.1.0u.6681_B20230703) Router firmware within the cstecgi.cgi binary (sub_42F32C function). The web interface reads the \"lang\" parameter and constructs Help URL strings using sprintf() into fixed-size stack buffers without proper length validation. Maliciously crafted input can overflow these buffers, potentially leading to arbitrary code execution or memory corruption, without requiring authentication."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad de desbordamiento de b\u00fafer de pila existe en el firmware del router ToToLink LR1200GB (V9.1.0u.6619_B20230130) y NR1800X (V9.1.0u.6681_B20230703) dentro del binario cstecgi.cgi (funci\u00f3n sub_42F32C). La interfaz web lee el par\u00e1metro \u2019lang\u2019 y construye cadenas de URL de ayuda usando sprintf() en b\u00faferes de pila de tama\u00f1o fijo sin una validaci\u00f3n de longitud adecuada. Una entrada creada maliciosamente puede desbordar estos b\u00faferes, lo que podr\u00eda llevar a ejecuci\u00f3n de c\u00f3digo arbitrario o corrupci\u00f3n de memoria, sin requerir autenticaci\u00f3n."
        }
      ],
      "id": "CVE-2025-60684",
      "lastModified": "2026-11-05T14:10:00.273",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 2.5,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-60684",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-11-13T17:32:41.749271Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-11-13T16:15:52.337",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/yifan20020708/SGTaint-0-day/blob/main/ToToLink/ToToLink-LR1200GB/CVE-2025-60684.md"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-60688

    Vulnerability from fkie_nvd - Published: 2025-11-13 16:15 - Updated: 2026-11-05 14:10
    Summary
    A stack buffer overflow vulnerability exists in the ToToLink LR1200GB (V9.1.0u.6619_B20230130) and NR1800X (V9.1.0u.6681_B20230703) Router firmware within the cstecgi.cgi binary (setDefResponse function). The binary reads the "IpAddress" parameter from a web request and copies it into a fixed-size stack buffer using strcpy() without any length validation. Maliciously crafted input can overflow the buffer, leading to potential arbitrary code execution or memory corruption, without requiring authentication.
    Impacted products
    Vendor Product Version
    totolink lr1200gb_firmware 9.1.0u.6619_b20230130
    totolink lr1200gb -
    totolink nr1800x_firmware 9.1.0u.6681_b20230703
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:lr1200gb_firmware:9.1.0u.6619_b20230130:*:*:*:*:*:*:*",
                  "matchCriteriaId": "00F36DE9-D043-4C8B-9EF9-8DA669589E85",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:lr1200gb:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8442849E-5B06-41A1-8DA8-827FBD7A34E5",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6681_b20230703:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F9DCAA5-1EC6-44A1-9606-B6FBF29DEC65",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A stack buffer overflow vulnerability exists in the ToToLink LR1200GB (V9.1.0u.6619_B20230130) and NR1800X (V9.1.0u.6681_B20230703) Router firmware within the cstecgi.cgi binary (setDefResponse function). The binary reads the \"IpAddress\" parameter from a web request and copies it into a fixed-size stack buffer using strcpy() without any length validation. Maliciously crafted input can overflow the buffer, leading to potential arbitrary code execution or memory corruption, without requiring authentication."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad de desbordamiento de b\u00fafer de pila existe en el firmware del router ToToLink LR1200GB (V9.1.0u.6619_B20230130) y NR1800X (V9.1.0u.6681_B20230703) dentro del binario cstecgi.cgi (funci\u00f3n setDefResponse). El binario lee el par\u00e1metro \u2019IpAddress\u2019 de una solicitud web y lo copia en un b\u00fafer de pila de tama\u00f1o fijo usando strcpy() sin ninguna validaci\u00f3n de longitud. Una entrada creada maliciosamente puede desbordar el b\u00fafer, lo que lleva a una potencial ejecuci\u00f3n de c\u00f3digo arbitrario o corrupci\u00f3n de memoria, sin requerir autenticaci\u00f3n."
        }
      ],
      "id": "CVE-2025-60688",
      "lastModified": "2026-11-05T14:10:00.273",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 2.5,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-60688",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-11-13T17:36:05.536063Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-11-13T16:15:52.850",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/yifan20020708/SGTaint-0-day/blob/main/ToToLink/ToToLink-LR1200GB/CVE-2025-60688.md"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-5030

    Vulnerability from fkie_nvd - Published: 2026-03-29 05:15 - Updated: 2026-06-17 10:58
    Summary
    A vulnerability has been found in Totolink NR1800X 9.1.0u.6279_B20210910. This issue affects the function NTPSyncWithHost of the file /cgi-bin/cstecgi.cgi of the component Telnet Service. The manipulation of the argument host_time leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:o:totolink:nr1800x_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Telnet Service"
              ],
              "product": "NR1800X",
              "vendor": "Totolink",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.1.0u.6279_B20210910"
                }
              ]
            }
          ],
          "source": "cna@vuldb.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Totolink NR1800X 9.1.0u.6279_B20210910. This issue affects the function NTPSyncWithHost of the file /cgi-bin/cstecgi.cgi of the component Telnet Service. The manipulation of the argument host_time leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "es",
          "value": "Se ha encontrado una vulnerabilidad en Totolink NR1800X 9.1.0u.6279_B20210910. Este problema afecta a la funci\u00f3n NTPSyncWithHost del archivo /cgi-bin/cstecgi.cgi del componente Servicio Telnet. La manipulaci\u00f3n del argumento host_time conduce a inyecci\u00f3n de comandos. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede ser utilizado."
        }
      ],
      "id": "CVE-2026-5030",
      "lastModified": "2026-06-17T10:58:18.290",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "cna@vuldb.com",
            "type": "Secondary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 6.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.4,
            "source": "cna@vuldb.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 2.1,
              "baseSeverity": "LOW",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "PROOF_OF_CONCEPT",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "LOW",
              "vulnConfidentialityImpact": "LOW",
              "vulnIntegrityImpact": "LOW",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-5030",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-03-30T13:28:35.305554Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-03-29T05:15:55.603",
      "references": [
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://lavender-bicycle-a5a.notion.site/TOTOLINK-NR1800X-NTPSyncWithHost-32153a41781f8032afebc0802b704e9c?source=copy_link"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/submit/778529"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/vuln/353952"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Permissions Required",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/vuln/353952/cti"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "sourceIdentifier": "cna@vuldb.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-74"
            },
            {
              "lang": "en",
              "value": "CWE-77"
            }
          ],
          "source": "cna@vuldb.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-77"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2026-1328

    Vulnerability from fkie_nvd - Published: 2026-01-22 15:16 - Updated: 2026-06-17 10:15
    Summary
    A vulnerability was detected in Totolink NR1800X 9.1.0u.6279_B20210910. Impacted is the function setWizardCfg of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. Performing a manipulation of the argument ssid results in buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:o:totolink:nr1800x_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "NR1800X",
              "vendor": "Totolink",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.1.0u.6279_B20210910"
                }
              ]
            }
          ],
          "source": "cna@vuldb.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was detected in Totolink NR1800X 9.1.0u.6279_B20210910. Impacted is the function setWizardCfg of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. Performing a manipulation of the argument ssid results in buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 una vulnerabilidad en Totolink NR1800X 9.1.0u.6279_B20210910. Afectada es la funci\u00f3n setWizardCfg del archivo /cgi-bin/cstecgi.cgi del componente POST Request Handler. Realizar una manipulaci\u00f3n del argumento ssid resulta en un desbordamiento de b\u00fafer. El ataque puede iniciarse de forma remota. El exploit ya es p\u00fablico y puede utilizarse."
        }
      ],
      "id": "CVE-2026-1328",
      "lastModified": "2026-06-17T10:15:36.570",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 9.0,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "cna@vuldb.com",
            "type": "Secondary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 7.4,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "PROOF_OF_CONCEPT",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-1328",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-01-22T16:14:38.515460Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-01-22T15:16:51.173",
      "references": [
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://lavender-bicycle-a5a.notion.site/TOTOLINK-NR1800X-setWizardCfg-2e453a41781f80568a54c9368082fbe9?source=copy_link"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Permissions Required",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/?ctiid.342304"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/?id.342304"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/?submit.735792"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "sourceIdentifier": "cna@vuldb.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            },
            {
              "lang": "en",
              "value": "CWE-120"
            }
          ],
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-1327

    Vulnerability from fkie_nvd - Published: 2026-01-22 15:16 - Updated: 2026-06-17 10:15
    Summary
    A security vulnerability has been detected in Totolink NR1800X 9.1.0u.6279_B20210910. This issue affects the function setTracerouteCfg of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. Such manipulation of the argument command leads to command injection. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:o:totolink:nr1800x_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "NR1800X",
              "vendor": "Totolink",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.1.0u.6279_B20210910"
                }
              ]
            }
          ],
          "source": "cna@vuldb.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Totolink NR1800X 9.1.0u.6279_B20210910. This issue affects the function setTracerouteCfg of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. Such manipulation of the argument command leads to command injection. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
        },
        {
          "lang": "es",
          "value": "Se ha detectado una vulnerabilidad de seguridad en Totolink NR1800X 9.1.0u.6279_B20210910. Este problema afecta a la funci\u00f3n setTracerouteCfg del archivo /cgi-bin/cstecgi.cgi del componente POST Request Handler. Dicha manipulaci\u00f3n del argumento command conduce a una inyecci\u00f3n de comandos. El ataque puede ser lanzado de forma remota. El exploit ha sido divulgado p\u00fablicamente y puede ser utilizado."
        }
      ],
      "id": "CVE-2026-1327",
      "lastModified": "2026-06-17T10:15:36.433",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "cna@vuldb.com",
            "type": "Secondary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 6.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.4,
            "source": "cna@vuldb.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 2.1,
              "baseSeverity": "LOW",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "PROOF_OF_CONCEPT",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "LOW",
              "vulnConfidentialityImpact": "LOW",
              "vulnIntegrityImpact": "LOW",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-1327",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-01-22T14:31:37.974783Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-01-22T15:16:50.967",
      "references": [
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://lavender-bicycle-a5a.notion.site/TOTOLINK-NR1800X-setTracerouteCfg-2e453a41781f80df8ef9d32983758502?source=copy_link"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Permissions Required",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/?ctiid.342303"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/?id.342303"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/?submit.735790"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "sourceIdentifier": "cna@vuldb.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-74"
            },
            {
              "lang": "en",
              "value": "CWE-77"
            }
          ],
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-1326

    Vulnerability from fkie_nvd - Published: 2026-01-22 15:16 - Updated: 2026-06-17 10:15
    Summary
    A weakness has been identified in Totolink NR1800X 9.1.0u.6279_B20210910. This vulnerability affects the function setWanCfg of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. This manipulation of the argument Hostname causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:o:totolink:nr1800x_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "NR1800X",
              "vendor": "Totolink",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.1.0u.6279_B20210910"
                }
              ]
            }
          ],
          "source": "cna@vuldb.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A weakness has been identified in Totolink NR1800X 9.1.0u.6279_B20210910. This vulnerability affects the function setWanCfg of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. This manipulation of the argument Hostname causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be used for attacks."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una debilidad en Totolink NR1800X 9.1.0u.6279_B20210910. Esta vulnerabilidad afecta a la funci\u00f3n setWanCfg del archivo /cgi-bin/cstecgi.cgi del componente POST Request Handler. Esta manipulaci\u00f3n del argumento Hostname causa inyecci\u00f3n de comandos. El ataque puede iniciarse de forma remota. El exploit ha sido puesto a disposici\u00f3n del p\u00fablico y podr\u00eda ser utilizado para ataques."
        }
      ],
      "id": "CVE-2026-1326",
      "lastModified": "2026-06-17T10:15:36.297",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "cna@vuldb.com",
            "type": "Secondary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 6.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.4,
            "source": "cna@vuldb.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 2.1,
              "baseSeverity": "LOW",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "PROOF_OF_CONCEPT",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "LOW",
              "vulnConfidentialityImpact": "LOW",
              "vulnIntegrityImpact": "LOW",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-1326",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-01-22T20:18:40.999365Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-01-22T15:16:50.790",
      "references": [
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://lavender-bicycle-a5a.notion.site/TOTOLINK-NR1800X-setWanCfg-2e453a41781f80b390f3e1ce0d9dd5b9?source=copy_link"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Permissions Required",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/?ctiid.342302"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/?id.342302"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/?submit.735787"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/"
        }
      ],
      "sourceIdentifier": "cna@vuldb.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-74"
            },
            {
              "lang": "en",
              "value": "CWE-77"
            }
          ],
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-45845

    Vulnerability from fkie_nvd - Published: 2025-05-08 16:15 - Updated: 2026-06-17 09:25
    Summary
    TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the ssid5g parameter in the setWiFiEasyGuestCfg function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6681_b20230703
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6681_b20230703:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F9DCAA5-1EC6-44A1-9606-B6FBF29DEC65",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the ssid5g parameter in the setWiFiEasyGuestCfg function."
        },
        {
          "lang": "es",
          "value": "Se descubri\u00f3 que TOTOLINK NR1800X V9.1.0u.6681_B20230703 conten\u00eda un desbordamiento de pila autenticado a trav\u00e9s del par\u00e1metro ssid5g en la funci\u00f3n setWiFiEasyGuestCfg."
        }
      ],
      "id": "CVE-2025-45845",
      "lastModified": "2026-06-17T09:25:45.710",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-45845",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-05-13T14:22:59.516580Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-05-08T16:15:26.910",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/regainer27/CVE-key/tree/main/bo5"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/home/menu/detail/menu_listtpl/download/id/225/ids/36.html"
        },
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/regainer27/CVE-key/tree/main/bo5"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-45844

    Vulnerability from fkie_nvd - Published: 2025-05-08 16:15 - Updated: 2026-06-17 09:25
    Summary
    TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the ssid parameter in the setWiFiBasicCfg function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6681_b20230703
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6681_b20230703:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F9DCAA5-1EC6-44A1-9606-B6FBF29DEC65",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the ssid parameter in the setWiFiBasicCfg function."
        },
        {
          "lang": "es",
          "value": "Se descubri\u00f3 que TOTOLINK NR1800X V9.1.0u.6681_B20230703 conten\u00eda un desbordamiento de pila autenticado a trav\u00e9s del par\u00e1metro ssid en la funci\u00f3n setWiFiBasicCfg."
        }
      ],
      "id": "CVE-2025-45844",
      "lastModified": "2026-06-17T09:25:45.540",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-45844",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-05-13T14:13:17.100783Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-05-08T16:15:26.813",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/regainer27/CVE-key/tree/main/bo6"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/home/menu/detail/menu_listtpl/download/id/225/ids/36.html"
        },
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/regainer27/CVE-key/tree/main/bo6"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-45843

    Vulnerability from fkie_nvd - Published: 2025-05-08 16:15 - Updated: 2026-06-17 09:25
    Summary
    TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the ssid parameter in the setWiFiGuestCfg function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6681_b20230703
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6681_b20230703:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F9DCAA5-1EC6-44A1-9606-B6FBF29DEC65",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the ssid parameter in the setWiFiGuestCfg function."
        },
        {
          "lang": "es",
          "value": "Se descubri\u00f3 que TOTOLINK NR1800X V9.1.0u.6681_B20230703 conten\u00eda un desbordamiento de pila autenticado a trav\u00e9s del par\u00e1metro ssid en la funci\u00f3n setWiFiGuestCfg."
        }
      ],
      "id": "CVE-2025-45843",
      "lastModified": "2026-06-17T09:25:45.373",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-45843",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-05-12T12:30:00.743619Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-05-08T16:15:26.730",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/regainer27/CVE-key/tree/main/bo2"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/home/menu/detail/menu_listtpl/download/id/225/ids/36.html"
        },
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/regainer27/CVE-key/tree/main/bo2"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-45842

    Vulnerability from fkie_nvd - Published: 2025-05-08 16:15 - Updated: 2026-06-17 09:25
    Summary
    TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the ssid5g parameter in the setWiFiEasyCfg function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6681_b20230703
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6681_b20230703:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F9DCAA5-1EC6-44A1-9606-B6FBF29DEC65",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the ssid5g parameter in the setWiFiEasyCfg function."
        },
        {
          "lang": "es",
          "value": "Se descubri\u00f3 que TOTOLINK NR1800X V9.1.0u.6681_B20230703 conten\u00eda un desbordamiento de pila autenticado a trav\u00e9s del par\u00e1metro ssid5g en la funci\u00f3n setWiFiEasyCfg."
        }
      ],
      "id": "CVE-2025-45842",
      "lastModified": "2026-06-17T09:25:45.197",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-45842",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-05-12T12:29:02.667839Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-05-08T16:15:26.647",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/regainer27/CVE-key/tree/main/bo3"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/home/menu/detail/menu_listtpl/download/id/225/ids/36.html"
        },
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/regainer27/CVE-key/tree/main/bo3"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2025-45841

    Vulnerability from fkie_nvd - Published: 2025-05-08 16:15 - Updated: 2026-06-17 09:25
    Summary
    TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the text parameter in the setSmsCfg function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6681_b20230703
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6681_b20230703:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F9DCAA5-1EC6-44A1-9606-B6FBF29DEC65",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6681_B20230703 was discovered to contain an authenticated stack overflow via the text parameter in the setSmsCfg function."
        },
        {
          "lang": "es",
          "value": "Se descubri\u00f3 que TOTOLINK NR1800X V9.1.0u.6681_B20230703 contiene un desbordamiento de pila autenticado a trav\u00e9s del par\u00e1metro de texto en la funci\u00f3n setSmsCfg."
        }
      ],
      "id": "CVE-2025-45841",
      "lastModified": "2026-06-17T09:25:45.027",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 2.5,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-45841",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-05-12T18:38:35.246907Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-05-08T16:15:26.557",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit"
          ],
          "url": "https://github.com/regainer27/CVE-key/blob/main/bo1/README.md"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Product"
          ],
          "url": "https://www.totolink.net/home/menu/detail/menu_listtpl/download/id/225/ids/36.html"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2024-35388

    Vulnerability from fkie_nvd - Published: 2024-05-24 19:15 - Updated: 2026-06-17 07:34
    Summary
    TOTOLINK NR1800X v9.1.0u.6681_B20230703 was discovered to contain a stack overflow via the password parameter in the function urldecode
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6681_b20230703
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "nr1800x",
              "vendor": "totolink",
              "versions": [
                {
                  "status": "affected",
                  "version": "v9.1.0u.6681_B20230703"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6681_b20230703:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F9DCAA5-1EC6-44A1-9606-B6FBF29DEC65",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X v9.1.0u.6681_B20230703 was discovered to contain a stack overflow via the password parameter in the function urldecode"
        },
        {
          "lang": "es",
          "value": "Se descubri\u00f3 que TOTOLINK NR1800X v9.1.0u.6681_B20230703 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro de contrase\u00f1a en la funci\u00f3n urldecode"
        }
      ],
      "id": "CVE-2024-35388",
      "lastModified": "2026-06-17T07:34:51.310",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2024-35388",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-05-28T11:16:21.268075Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-05-24T19:15:10.037",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Broken Link"
          ],
          "url": "https://github.com/s4ndw1ch136/IOT-vuln-reports/blob/main/TOTOLINK%20NR1800X/README.md"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Broken Link"
          ],
          "url": "https://github.com/s4ndw1ch136/IOT-vuln-reports/blob/main/TOTOLINK%20NR1800X/README.md"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-7220

    Vulnerability from fkie_nvd - Published: 2024-01-09 08:15 - Updated: 2026-06-17 06:52
    Summary
    A vulnerability was found in Totolink NR1800X 9.1.0u.6279_B20210910 and classified as critical. Affected by this issue is the function loginAuth of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-249854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "NR1800X",
              "vendor": "Totolink",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.1.0u.6279_B20210910"
                }
              ]
            }
          ],
          "source": "cna@vuldb.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Totolink NR1800X 9.1.0u.6279_B20210910 and classified as critical. Affected by this issue is the function loginAuth of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-249854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad fue encontrada en Totolink NR1800X 9.1.0u.6279_B20210910 y clasificada como cr\u00edtica. La funci\u00f3n loginAuth del archivo /cgi-bin/cstecgi.cgi es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento password provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede lanzarse de forma remota. La explotaci\u00f3n ha sido divulgada y puede utilizarse. VDB-249854 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
        }
      ],
      "id": "CVE-2023-7220",
      "lastModified": "2026-06-17T06:52:20.557",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 10.0,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "cna@vuldb.com",
            "type": "Secondary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "cna@vuldb.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-7220",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-01-10T16:23:23.665335Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2024-01-09T08:15:36.490",
      "references": [
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/jylsec/vuldb/blob/main/TOTOLINK/NR1800X/1/README.md"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://vuldb.com/?ctiid.249854"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://vuldb.com/?id.249854"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/jylsec/vuldb/blob/main/TOTOLINK/NR1800X/1/README.md"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://vuldb.com/?ctiid.249854"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://vuldb.com/?id.249854"
        }
      ],
      "sourceIdentifier": "cna@vuldb.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-36340

    Vulnerability from fkie_nvd - Published: 2023-10-16 05:15 - Updated: 2026-06-17 06:06
    Summary
    TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain a stack overflow via the http_host parameter in the function loginAuth.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        },
        {
          "affectedData": [
            {
              "cpes": [
                "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*"
              ],
              "defaultStatus": "unknown",
              "product": "nr1800x_firmware",
              "vendor": "totolink",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.1.0u.6279_b20210910"
                }
              ]
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain a stack overflow via the http_host parameter in the function loginAuth."
        },
        {
          "lang": "es",
          "value": "Se descubri\u00f3 que TOTOLINK NR1800X V9.1.0u.6279_B20210910 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro http_host en la funci\u00f3n loginAuth."
        }
      ],
      "id": "CVE-2023-36340",
      "lastModified": "2026-06-17T06:06:04.210",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-36340",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2024-09-16T18:52:30.727292Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-10-16T05:15:49.633",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/Archerber/bug_submit/blob/main/TOTOLINK/TOTOLINK-NR1800X.md"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/Archerber/bug_submit/blob/main/TOTOLINK/TOTOLINK-NR1800X.md"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-44256

    Vulnerability from fkie_nvd - Published: 2022-11-23 16:15 - Updated: 2026-06-17 05:08
    Summary
    TOTOLINK LR350 V9.3.5u.6369_B20220309 contains a post-authentication buffer overflow via parameter lang in the setLanguageCfg function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.3.5u.6369_b20220309
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.3.5u.6369_b20220309:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A7C001CA-BA4C-494F-A3B8-245505051016",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK LR350 V9.3.5u.6369_B20220309 contains a post-authentication buffer overflow via parameter lang in the setLanguageCfg function."
        },
        {
          "lang": "es",
          "value": "TOTOLINK LR350 V9.3.5u.6369_B20220309 contiene un desbordamiento del b\u00fafer posterior a la autenticaci\u00f3n a trav\u00e9s del par\u00e1metro lang en la funci\u00f3n setLanguageCfg."
        }
      ],
      "id": "CVE-2022-44256",
      "lastModified": "2026-06-17T05:08:00.340",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-44256",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-04-25T20:07:39.438593Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-11-23T16:15:10.820",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/LR350-bof-setLanguageCfg-ddd638b9bb2d4c72b8dba5125c293141"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/LR350-bof-setLanguageCfg-ddd638b9bb2d4c72b8dba5125c293141"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2022-41528

    Vulnerability from fkie_nvd - Published: 2022-10-06 19:15 - Updated: 2026-06-17 05:03
    Summary
    TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the text parameter in the setSmsCfg function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the text parameter in the setSmsCfg function."
        },
        {
          "lang": "es",
          "value": "Se ha detectado que TOTOLINK NR1800X versi\u00f3n V9.1.0u.6279_B20210910, contiene un desbordamiento de pila autenticado por medio del par\u00e1metro text en la funci\u00f3n setSmsCfg"
        }
      ],
      "id": "CVE-2022-41528",
      "lastModified": "2026-06-17T05:03:19.453",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-10-06T19:15:11.337",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-setSmsCfg-0f2be43baa9842d79ae6bafbded574f8"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-setSmsCfg-0f2be43baa9842d79ae6bafbded574f8"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-41527

    Vulnerability from fkie_nvd - Published: 2022-10-06 19:15 - Updated: 2026-06-17 05:03
    Summary
    TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the pppoeUser parameter in the setOpModeCfg function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the pppoeUser parameter in the setOpModeCfg function."
        },
        {
          "lang": "es",
          "value": "Se ha detectado que TOTOLINK NR1800X versi\u00f3n V9.1.0u.6279_B20210910, contiene un desbordamiento de pila autenticado por medio del par\u00e1metro pppoeUser en la funci\u00f3n setOpModeCfg"
        }
      ],
      "id": "CVE-2022-41527",
      "lastModified": "2026-06-17T05:03:19.340",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-10-06T19:15:11.217",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-setOpModeCfg-2e286823203c405bbdec4305b0924a02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-setOpModeCfg-2e286823203c405bbdec4305b0924a02"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-41526

    Vulnerability from fkie_nvd - Published: 2022-10-06 19:15 - Updated: 2026-06-17 05:03
    Summary
    TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the ip parameter in the setDiagnosisCfg function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the ip parameter in the setDiagnosisCfg function."
        },
        {
          "lang": "es",
          "value": "Se ha detectado que TOTOLINK NR1800X versi\u00f3n V9.1.0u.6279_B20210910, contiene un desbordamiento de pila autenticado por medio del par\u00e1metro ip en la funci\u00f3n setDiagnosisCfg"
        }
      ],
      "id": "CVE-2022-41526",
      "lastModified": "2026-06-17T05:03:19.223",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-10-06T19:15:11.117",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-setDiagnosisCfg-fcbc55a98e4b4bfbb94db610e666e834"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-setDiagnosisCfg-fcbc55a98e4b4bfbb94db610e666e834"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-41525

    Vulnerability from fkie_nvd - Published: 2022-10-06 19:15 - Updated: 2026-06-17 05:03
    Summary
    TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain a command injection vulnerability via the OpModeCfg function at /cgi-bin/cstecgi.cgi.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain a command injection vulnerability via the OpModeCfg function at /cgi-bin/cstecgi.cgi."
        },
        {
          "lang": "es",
          "value": "Se ha detectado que TOTOLINK NR1800X versi\u00f3n V9.1.0u.6279_B20210910, contiene una vulnerabilidad de inyecci\u00f3n de comandos por medio de la funci\u00f3n OpModeCfg en el archivo /cgi-bin/cstecgi.cgi"
        }
      ],
      "id": "CVE-2022-41525",
      "lastModified": "2026-06-17T05:03:19.107",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-10-06T19:15:11.007",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-command-injection-setOpModeCfg-7b10868ba53544148d9aa3100b5df5cc"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-command-injection-setOpModeCfg-7b10868ba53544148d9aa3100b5df5cc"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-78"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-41524

    Vulnerability from fkie_nvd - Published: 2022-10-06 19:15 - Updated: 2026-06-17 05:03
    Summary
    TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the week, sTime, and eTime parameters in the setParentalRules function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the week, sTime, and eTime parameters in the setParentalRules function."
        },
        {
          "lang": "es",
          "value": "Se ha detectado que TOTOLINK NR1800X versi\u00f3n V9.1.0u.6279_B20210910, contiene un desbordamiento de pila autenticado por medio de los par\u00e1metros week, sTime y eTime en la funci\u00f3n setParentalRules"
        }
      ],
      "id": "CVE-2022-41524",
      "lastModified": "2026-06-17T05:03:18.990",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-10-06T19:15:10.897",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-setParentalRules-0da79b5ce7d44212b275a33b77935a42"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-setParentalRules-0da79b5ce7d44212b275a33b77935a42"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-41523

    Vulnerability from fkie_nvd - Published: 2022-10-06 19:15 - Updated: 2026-06-17 05:03
    Summary
    TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the command parameter in the setTracerouteCfg function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the command parameter in the setTracerouteCfg function."
        },
        {
          "lang": "es",
          "value": "Se ha detectado que TOTOLINK NR1800X versi\u00f3n V9.1.0u.6279_B20210910, contiene un desbordamiento de pila autenticado por medio del par\u00e1metro command en la funci\u00f3n setTracerouteCfg"
        }
      ],
      "id": "CVE-2022-41523",
      "lastModified": "2026-06-17T05:03:18.877",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-10-06T19:15:10.787",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-setTracerouteCfg-0e29fc2fcba74a28a3e3822d71ddb2ef"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-setTracerouteCfg-0e29fc2fcba74a28a3e3822d71ddb2ef"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-41522

    Vulnerability from fkie_nvd - Published: 2022-10-06 19:15 - Updated: 2026-06-17 05:03
    Summary
    TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an unauthenticated stack overflow via the "main" function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an unauthenticated stack overflow via the \"main\" function."
        },
        {
          "lang": "es",
          "value": "Se ha detectado que TOTOLINK NR1800X versi\u00f3n V9.1.0u.6279_B20210910, contiene un desbordamiento de pila no autenticado por medio de la funci\u00f3n \"main\""
        }
      ],
      "id": "CVE-2022-41522",
      "lastModified": "2026-06-17T05:03:18.760",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-10-06T19:15:10.360",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-main-pre-authentication-29ccdaa7af054674828f7b3cf38aae82"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-main-pre-authentication-29ccdaa7af054674828f7b3cf38aae82"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-41521

    Vulnerability from fkie_nvd - Published: 2022-10-06 18:17 - Updated: 2026-06-17 05:03
    Summary
    TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the sPort/ePort parameter in the setIpPortFilterRules function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the sPort/ePort parameter in the setIpPortFilterRules function."
        },
        {
          "lang": "es",
          "value": "Se ha detectado que TOTOLINK NR1800X versi\u00f3n V9.1.0u.6279_B20210910, contiene un desbordamiento de pila autenticado por medio del par\u00e1metro sPort/ePort en la funci\u00f3n setIpPortFilterRules"
        }
      ],
      "id": "CVE-2022-41521",
      "lastModified": "2026-06-17T05:03:18.643",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-10-06T18:17:01.857",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-setIpPortFilterRules-fd99f83f37ad40fab7d7b376942633d2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-setIpPortFilterRules-fd99f83f37ad40fab7d7b376942633d2"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-41520

    Vulnerability from fkie_nvd - Published: 2022-10-06 18:17 - Updated: 2026-06-17 05:03
    Summary
    TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the File parameter in the UploadCustomModule function.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain an authenticated stack overflow via the File parameter in the UploadCustomModule function."
        },
        {
          "lang": "es",
          "value": "Se ha detectado que TOTOLINK NR1800X versi\u00f3n V9.1.0u.6279_B20210910, contiene un desbordamiento de pila autenticado por medio del par\u00e1metro File en la funci\u00f3n UploadCustomModule"
        }
      ],
      "id": "CVE-2022-41520",
      "lastModified": "2026-06-17T05:03:18.527",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-10-06T18:17:00.300",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-UploadCustomModule-2bcabf2017084213b9a238fab938d782"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-bof-UploadCustomModule-2bcabf2017084213b9a238fab938d782"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-41518

    Vulnerability from fkie_nvd - Published: 2022-10-06 18:16 - Updated: 2026-06-17 05:03
    Summary
    TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain a command injection vulnerability via the UploadFirmwareFile function at /cgi-bin/cstecgi.cgi.
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain a command injection vulnerability via the UploadFirmwareFile function at /cgi-bin/cstecgi.cgi."
        },
        {
          "lang": "es",
          "value": "Se ha detectado que TOTOLINK NR1800X versi\u00f3n V9.1.0u.6279_B20210910, contiene una vulnerabilidad de inyecci\u00f3n de comandos por medio de la funci\u00f3n UploadFirmwareFile en el archivo /cgi-bin/cstecgi.cgi"
        }
      ],
      "id": "CVE-2022-41518",
      "lastModified": "2026-06-17T05:03:18.410",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-10-06T18:16:59.107",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-command-injection-UploadFirmwareFile-a98e96086d824b7d8b788a8639322457"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/NR1800X-command-injection-UploadFirmwareFile-a98e96086d824b7d8b788a8639322457"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-78"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-41517

    Vulnerability from fkie_nvd - Published: 2022-10-06 18:16 - Updated: 2026-06-17 05:03
    Summary
    TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain a stack overflow in the lang parameter in the setLanguageCfg function
    Impacted products
    Vendor Product Version
    totolink nr1800x_firmware 9.1.0u.6279_b20210910
    totolink nr1800x -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:totolink:nr1800x_firmware:9.1.0u.6279_b20210910:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CFB91EF-6C07-45CB-AA17-A3D937FC9D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:totolink:nr1800x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4D2D0E8-2678-4238-8229-83450ECA1153",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK NR1800X V9.1.0u.6279_B20210910 was discovered to contain a stack overflow in the lang parameter in the setLanguageCfg function"
        },
        {
          "lang": "es",
          "value": "Se ha detectado que TOTOLINK NR1800X versi\u00f3n V9.1.0u.6279_B20210910, contiene un desbordamiento de pila en el par\u00e1metro lang de la funci\u00f3n setLanguageCfg"
        }
      ],
      "id": "CVE-2022-41517",
      "lastModified": "2026-06-17T05:03:18.293",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-10-06T18:16:57.880",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/TOTOLink-NR1800X-f97f2b9552c04eaf85fce31bccbfcf04"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://brief-nymphea-813.notion.site/TOTOLink-NR1800X-f97f2b9552c04eaf85fce31bccbfcf04"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2026-5030 (GCVE-0-2026-5030)

    Vulnerability from nvd – Published: 2026-03-29 03:30 – Updated: 2026-03-30 13:28
    VLAI
    Title
    Totolink NR1800X Telnet Service cstecgi.cgi NTPSyncWithHost command injection
    Summary
    A vulnerability has been found in Totolink NR1800X 9.1.0u.6279_B20210910. This issue affects the function NTPSyncWithHost of the file /cgi-bin/cstecgi.cgi of the component Telnet Service. The manipulation of the argument host_time leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-30 13:28 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3867 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Totolink NR1800X Affected: 9.1.0u.6279_B20210910
        cpe:2.3:o:totolink:nr1800x_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-5030",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-30T13:28:35.305554Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-30T13:28:48.091Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:totolink:nr1800x_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Telnet Service"
              ],
              "product": "NR1800X",
              "vendor": "Totolink",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.1.0u.6279_B20210910"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_mie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Totolink NR1800X 9.1.0u.6279_B20210910. This issue affects the function NTPSyncWithHost of the file /cgi-bin/cstecgi.cgi of the component Telnet Service. The manipulation of the argument host_time leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-29T03:30:15.254Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-353952 | Totolink NR1800X Telnet Service cstecgi.cgi NTPSyncWithHost command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/353952"
            },
            {
              "name": "VDB-353952 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/353952/cti"
            },
            {
              "name": "Submit #778529 | TOTOLINK NR1800X NR1800X_Firmware V9.1.0u.6279_B20210910 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/778529"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://lavender-bicycle-a5a.notion.site/TOTOLINK-NR1800X-NTPSyncWithHost-32153a41781f8032afebc0802b704e9c?source=copy_link"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.totolink.net/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-03-27T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-03-27T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-03-27T17:01:03.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Totolink NR1800X Telnet Service cstecgi.cgi NTPSyncWithHost command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-5030",
        "datePublished": "2026-03-29T03:30:15.254Z",
        "dateReserved": "2026-03-27T15:55:59.708Z",
        "dateUpdated": "2026-03-30T13:28:48.091Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-1328 (GCVE-0-2026-1328)

    Vulnerability from nvd – Published: 2026-01-22 14:32 – Updated: 2026-02-23 08:53
    VLAI
    Title
    Totolink NR1800X POST Request cstecgi.cgi setWizardCfg buffer overflow
    Summary
    A vulnerability was detected in Totolink NR1800X 9.1.0u.6279_B20210910. Impacted is the function setWizardCfg of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. Performing a manipulation of the argument ssid results in buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-01-22 16:14 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3867 records in the last 180 days details
    References
    URL Tags
    https://vuldb.com/?id.342304 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.342304 signaturepermissions-required
    https://vuldb.com/?submit.735792 third-party-advisory
    https://lavender-bicycle-a5a.notion.site/TOTOLINK… exploit
    https://www.totolink.net/ product
    Impacted products
    Vendor Product Version
    Totolink NR1800X Affected: 9.1.0u.6279_B20210910
        cpe:2.3:o:totolink:nr1800x_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-1328",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-22T16:14:38.515460Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-22T16:14:48.638Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:totolink:nr1800x_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "POST Request Handler"
              ],
              "product": "NR1800X",
              "vendor": "Totolink",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.1.0u.6279_B20210910"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_mie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Totolink NR1800X 9.1.0u.6279_B20210910. Impacted is the function setWizardCfg of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. Performing a manipulation of the argument ssid results in buffer overflow. The attack may be initiated remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T08:53:16.410Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-342304 | Totolink NR1800X POST Request cstecgi.cgi setWizardCfg buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.342304"
            },
            {
              "name": "VDB-342304 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.342304"
            },
            {
              "name": "Submit #735792 | TOTOLINK NR1800X NR1800X_Firmware V9.1.0u.6279_B20210910 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.735792"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://lavender-bicycle-a5a.notion.site/TOTOLINK-NR1800X-setWizardCfg-2e453a41781f80568a54c9368082fbe9?source=copy_link"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.totolink.net/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-01-22T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-01-22T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-01-24T15:20:19.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Totolink NR1800X POST Request cstecgi.cgi setWizardCfg buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-1328",
        "datePublished": "2026-01-22T14:32:13.191Z",
        "dateReserved": "2026-01-22T07:43:48.228Z",
        "dateUpdated": "2026-02-23T08:53:16.410Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-5030 (GCVE-0-2026-5030)

    Vulnerability from cvelistv5 – Published: 2026-03-29 03:30 – Updated: 2026-03-30 13:28
    VLAI
    Title
    Totolink NR1800X Telnet Service cstecgi.cgi NTPSyncWithHost command injection
    Summary
    A vulnerability has been found in Totolink NR1800X 9.1.0u.6279_B20210910. This issue affects the function NTPSyncWithHost of the file /cgi-bin/cstecgi.cgi of the component Telnet Service. The manipulation of the argument host_time leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-30 13:28 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3867 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    Totolink NR1800X Affected: 9.1.0u.6279_B20210910
        cpe:2.3:o:totolink:nr1800x_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-5030",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-30T13:28:35.305554Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-30T13:28:48.091Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:totolink:nr1800x_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Telnet Service"
              ],
              "product": "NR1800X",
              "vendor": "Totolink",
              "versions": [
                {
                  "status": "affected",
                  "version": "9.1.0u.6279_B20210910"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "wxhwxhwxh_mie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been found in Totolink NR1800X 9.1.0u.6279_B20210910. This issue affects the function NTPSyncWithHost of the file /cgi-bin/cstecgi.cgi of the component Telnet Service. The manipulation of the argument host_time leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-29T03:30:15.254Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-353952 | Totolink NR1800X Telnet Service cstecgi.cgi NTPSyncWithHost command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/353952"
            },
            {
              "name": "VDB-353952 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/353952/cti"
            },
            {
              "name": "Submit #778529 | TOTOLINK NR1800X NR1800X_Firmware V9.1.0u.6279_B20210910 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/778529"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://lavender-bicycle-a5a.notion.site/TOTOLINK-NR1800X-NTPSyncWithHost-32153a41781f8032afebc0802b704e9c?source=copy_link"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.totolink.net/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-03-27T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-03-27T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-03-27T17:01:03.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Totolink NR1800X Telnet Service cstecgi.cgi NTPSyncWithHost command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-5030",
        "datePublished": "2026-03-29T03:30:15.254Z",
        "dateReserved": "2026-03-27T15:55:59.708Z",
        "dateUpdated": "2026-03-30T13:28:48.091Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }