Search
Find a vulnerability
Search criteria
27 vulnerabilities found for n-central by solarwinds
FKIE_CVE-2020-7984
Vulnerability from fkie_nvd - Published: 2020-01-26 21:15 - Updated: 2026-06-17 03:25
Severity
Summary
SolarWinds N-central before 12.1 SP1 HF5 and 12.2 before SP1 HF2 allows remote attackers to retrieve cleartext domain admin credentials from the Agent & Probe settings, and obtain other sensitive information. The attacker can use a customer ID to self register and read any aspects of the agent/appliance configuration.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| solarwinds | n-central | * | |
| solarwinds | n-central | * |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:solarwinds:n-central:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0D6491E4-72F5-4F8D-AEAA-6DA7590F6FAB",
"versionEndExcluding": "12.1.1.404",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:solarwinds:n-central:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5357BA14-B1C9-4E9F-9412-8961014B38A1",
"versionEndExcluding": "12.2.1.280",
"versionStartIncluding": "12.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "SolarWinds N-central before 12.1 SP1 HF5 and 12.2 before SP1 HF2 allows remote attackers to retrieve cleartext domain admin credentials from the Agent \u0026 Probe settings, and obtain other sensitive information. The attacker can use a customer ID to self register and read any aspects of the agent/appliance configuration."
},
{
"lang": "es",
"value": "SolarWinds N-central versiones anteriores a 12.1 SP1 HF5 y versiones 12.2 anteriores a SP1 HF2, permite a atacantes remotos recuperar credenciales de administrador de dominio de texto sin cifrar de la configuraci\u00f3n de Agent \u0026amp; Probe, y obtener otra informaci\u00f3n confidencial. El atacante puede utilizar un ID de cliente para registrarse a si mismo y leer cualquier aspecto de la configuraci\u00f3n de agent/appliance."
}
],
"id": "CVE-2020-7984",
"lastModified": "2026-06-17T03:25:44.447",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-01-26T21:15:10.387",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Patch",
"Third Party Advisory"
],
"url": "https://blog.huntresslabs.com/validating-the-solarwinds-n-central-dumpster-diver-vulnerability-5e3a045982e5"
},
{
"source": "cve@mitre.org",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-1-SP1-HF5"
},
{
"source": "cve@mitre.org",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-2-SP1-HF2"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://github.com/flipflopfpv"
},
{
"source": "cve@mitre.org",
"tags": [
"Broken Link",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://packetstormsecurity.com/files/156033"
},
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://success.solarwindsmsp.com/kb/solarwinds_n-central/How-to-Expunge-credentials-for-Customer-levels-of-SolarWinds-N-central"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://twitter.com/SecurityNewsbot/status/1219722631898812416"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.crn.com/news/managed-services/solarwinds-rmm-tool-has-open-zero-day-exploit-huntress-labs"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Patch",
"Third Party Advisory"
],
"url": "https://blog.huntresslabs.com/validating-the-solarwinds-n-central-dumpster-diver-vulnerability-5e3a045982e5"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-1-SP1-HF5"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-2-SP1-HF2"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://github.com/flipflopfpv"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://packetstormsecurity.com/files/156033"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://success.solarwindsmsp.com/kb/solarwinds_n-central/How-to-Expunge-credentials-for-Customer-levels-of-SolarWinds-N-central"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://twitter.com/SecurityNewsbot/status/1219722631898812416"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.crn.com/news/managed-services/solarwinds-rmm-tool-has-open-zero-day-exploit-huntress-labs"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-319"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-25622
Vulnerability from fkie_nvd - Published: 2020-12-16 15:15 - Updated: 2026-06-17 03:06
Severity
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows CSRF.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://ernw.de/en/publications.html | Third Party Advisory | |
| cve@mitre.org | https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/ | Third Party Advisory | |
| cve@mitre.org | https://support.solarwinds.com/SuccessCenter/s/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ernw.de/en/publications.html | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://support.solarwinds.com/SuccessCenter/s/ | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| solarwinds | n-central | 12.3.0.670 |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:solarwinds:n-central:12.3.0.670:*:*:*:*:*:*:*",
"matchCriteriaId": "252F566A-58BC-4CFF-BEC8-467935E3979B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows CSRF."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en SolarWinds N-Central versi\u00f3n 12.3.0.670.\u0026#xa0;El endpoint HTTP AdvancedScripts permite un ataque de tipo CSRF"
}
],
"id": "CVE-2020-25622",
"lastModified": "2026-06-17T03:06:59.760",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-12-16T15:15:12.663",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://ernw.de/en/publications.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://ernw.de/en/publications.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-25621
Vulnerability from fkie_nvd - Published: 2020-12-16 15:15 - Updated: 2026-06-17 03:06
Severity
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The local database does not require authentication: security is only based on ability to access a network interface. The database has keys and passwords.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://ernw.de/en/publications.html | Third Party Advisory | |
| cve@mitre.org | https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/ | Third Party Advisory | |
| cve@mitre.org | https://support.solarwinds.com/SuccessCenter/s/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ernw.de/en/publications.html | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://support.solarwinds.com/SuccessCenter/s/ | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| solarwinds | n-central | 12.3.0.670 |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:solarwinds:n-central:12.3.0.670:*:*:*:*:*:*:*",
"matchCriteriaId": "252F566A-58BC-4CFF-BEC8-467935E3979B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The local database does not require authentication: security is only based on ability to access a network interface. The database has keys and passwords."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en SolarWinds N-Central versi\u00f3n 12.3.0.670.\u0026#xa0;La base de datos local no requiere autenticaci\u00f3n: la seguridad solo es basada en la capacidad de acceder a una interfaz de red.\u0026#xa0;La base de datos contiene claves y contrase\u00f1as"
}
],
"id": "CVE-2020-25621",
"lastModified": "2026-06-17T03:06:59.650",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.5,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-12-16T15:15:12.600",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://ernw.de/en/publications.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://ernw.de/en/publications.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-25620
Vulnerability from fkie_nvd - Published: 2020-12-16 15:15 - Updated: 2026-06-17 03:06
Severity
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. Hard-coded Credentials exist by default for local user accounts named support@n-able.com and nableadmin@n-able.com. These allow logins to the N-Central Administrative Console (NAC) and/or the regular web interface.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://ernw.de/en/publications.html | Third Party Advisory | |
| cve@mitre.org | https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/ | Third Party Advisory | |
| cve@mitre.org | https://support.solarwinds.com/SuccessCenter/s/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ernw.de/en/publications.html | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://support.solarwinds.com/SuccessCenter/s/ | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| solarwinds | n-central | 12.3.0.670 |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:solarwinds:n-central:12.3.0.670:*:*:*:*:*:*:*",
"matchCriteriaId": "252F566A-58BC-4CFF-BEC8-467935E3979B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. Hard-coded Credentials exist by default for local user accounts named support@n-able.com and nableadmin@n-able.com. These allow logins to the N-Central Administrative Console (NAC) and/or the regular web interface."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en SolarWinds N-Central versi\u00f3n 12.3.0.670.\u0026#xa0;Se presentan Credenciales Embebidas por defecto para las cuentas de usuario locales denominadas support@n-able.com y nableadmin@n-able.com.\u0026#xa0;Estos permiten inicios de sesi\u00f3n en el N-Central Administrative Console (NAC) y/o la interfaz web normal"
}
],
"id": "CVE-2020-25620",
"lastModified": "2026-06-17T03:06:59.543",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-12-16T15:15:12.523",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://ernw.de/en/publications.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://ernw.de/en/publications.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-25619
Vulnerability from fkie_nvd - Published: 2020-12-16 14:15 - Updated: 2026-06-17 03:06
Severity
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The SSH component does not restrict the Communication Channel to Intended Endpoints. An attacker can leverage an SSH feature (port forwarding with a temporary key pair) to access network services on the 127.0.0.1 interface, even though this feature was only intended for user-to-agent communication.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://ernw.de/en/publications.html | Third Party Advisory | |
| cve@mitre.org | https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/ | Third Party Advisory | |
| cve@mitre.org | https://support.solarwinds.com/SuccessCenter/s/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ernw.de/en/publications.html | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://support.solarwinds.com/SuccessCenter/s/ | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| solarwinds | n-central | 12.3.0.670 |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:solarwinds:n-central:12.3.0.670:*:*:*:*:*:*:*",
"matchCriteriaId": "252F566A-58BC-4CFF-BEC8-467935E3979B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The SSH component does not restrict the Communication Channel to Intended Endpoints. An attacker can leverage an SSH feature (port forwarding with a temporary key pair) to access network services on the 127.0.0.1 interface, even though this feature was only intended for user-to-agent communication."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en SolarWinds N-Central versi\u00f3n 12.3.0.670.\u0026#xa0;El componente SSH no restringe el Canal de Comunicaci\u00f3n a unos Endpoints Previstos.\u0026#xa0;Un atacante puede aprovechar una funci\u00f3n SSH (reenv\u00edo de puertos con un par de claves temporales) para acceder a los servicios de red en la interfaz 127.0.0.1, aunque esta funci\u00f3n solo estaba destinada a la comunicaci\u00f3n de usuario a agente"
}
],
"id": "CVE-2020-25619",
"lastModified": "2026-06-17T03:06:59.433",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 3.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 2.5,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-12-16T14:15:12.620",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://ernw.de/en/publications.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://ernw.de/en/publications.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-25618
Vulnerability from fkie_nvd - Published: 2020-12-16 14:15 - Updated: 2026-06-17 03:06
Severity
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The sudo configuration has incorrect access control because the nable web user account is effectively able to run arbitrary OS commands as root (i.e., the use of root privileges is not limited to specific programs listed in the sudoers file).
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://ernw.de/en/publications.html | Third Party Advisory | |
| cve@mitre.org | https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/ | Third Party Advisory | |
| cve@mitre.org | https://support.solarwinds.com/SuccessCenter/s/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ernw.de/en/publications.html | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://support.solarwinds.com/SuccessCenter/s/ | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| solarwinds | n-central | 12.3.0.670 |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:solarwinds:n-central:12.3.0.670:*:*:*:*:*:*:*",
"matchCriteriaId": "252F566A-58BC-4CFF-BEC8-467935E3979B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The sudo configuration has incorrect access control because the nable web user account is effectively able to run arbitrary OS commands as root (i.e., the use of root privileges is not limited to specific programs listed in the sudoers file)."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en SolarWinds N-Central versi\u00f3n 12.3.0.670.\u0026#xa0;La configuraci\u00f3n de sudo presenta un control de acceso incorrecto porque la cuenta de usuario web nable puede ejecutar comandos arbitrarios del Sistema Operativo como root (es decir, el uso de privilegios root no se limita a los programas espec\u00edficos listados en el archivo sudoers)"
}
],
"id": "CVE-2020-25618",
"lastModified": "2026-06-17T03:06:59.320",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-12-16T14:15:12.557",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://ernw.de/en/publications.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://ernw.de/en/publications.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-25617
Vulnerability from fkie_nvd - Published: 2020-12-16 14:15 - Updated: 2026-06-17 03:06
Severity
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows Relative Path Traversal by an authenticated user of the N-Central Administration Console (NAC), leading to execution of OS commands as root.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://ernw.de/en/publications.html | Third Party Advisory | |
| cve@mitre.org | https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/ | Third Party Advisory | |
| cve@mitre.org | https://support.solarwinds.com/SuccessCenter/s/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ernw.de/en/publications.html | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://support.solarwinds.com/SuccessCenter/s/ | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| solarwinds | n-central | 12.3.0.670 |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:solarwinds:n-central:12.3.0.670:*:*:*:*:*:*:*",
"matchCriteriaId": "252F566A-58BC-4CFF-BEC8-467935E3979B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows Relative Path Traversal by an authenticated user of the N-Central Administration Console (NAC), leading to execution of OS commands as root."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en SolarWinds N-Central versi\u00f3n 12.3.0.670.\u0026#xa0;El endpoint HTTP AdvancedScripts permite un Salto de Ruta Relativo por parte de un usuario autenticado del N-Central Administration Console (NAC), conllevando a una ejecuci\u00f3n de los comandos del Sistema Operativo como root"
}
],
"id": "CVE-2020-25617",
"lastModified": "2026-06-17T03:06:59.203",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-12-16T14:15:12.480",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://ernw.de/en/publications.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://ernw.de/en/publications.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-15910
Vulnerability from fkie_nvd - Published: 2020-10-19 13:15 - Updated: 2026-06-17 02:57
Severity
Summary
SolarWinds N-Central version 12.3 GA and lower does not set the JSESSIONID attribute to HTTPOnly. This makes it possible to influence the cookie with javascript. An attacker could send the user to a prepared webpage or by influencing JavaScript to the extract the JESSIONID. This could then be forwarded to the attacker.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| solarwinds | n-central | * |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:solarwinds:n-central:*:*:*:*:general_availability:*:*:*",
"matchCriteriaId": "A83180E9-B67B-4DDE-B91F-2DDA022A610E",
"versionEndIncluding": "12.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "SolarWinds N-Central version 12.3 GA and lower does not set the JSESSIONID attribute to HTTPOnly. This makes it possible to influence the cookie with javascript. An attacker could send the user to a prepared webpage or by influencing JavaScript to the extract the JESSIONID. This could then be forwarded to the attacker."
},
{
"lang": "es",
"value": "SolarWinds N-Central versiones hasta 12.3 GA y anteriores, no establece el atributo JSESSIONID en HTTPOnly.\u0026#xa0;Esto permite influir en la cookie con javascript.\u0026#xa0;Un atacante podr\u00eda enviar al usuario a una p\u00e1gina web preparada o al influir en un JavaScript para extraer el JESSIONID.\u0026#xa0;Esto podr\u00eda ser reenviado al atacante"
}
],
"id": "CVE-2020-15910",
"lastModified": "2026-06-17T02:57:23.490",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-10-19T13:15:13.313",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
},
{
"source": "cve@mitre.org",
"tags": [
"Product"
],
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://www.solarwindsmsp.com/products/n-central"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-15909
Vulnerability from fkie_nvd - Published: 2020-10-19 13:15 - Updated: 2026-06-17 02:57
Severity
Summary
SolarWinds N-central through 2020.1 allows session hijacking and requires user interaction or physical access. The N-Central JSESSIONID cookie attribute is not checked against multiple sources such as sourceip, MFA claim, etc. as long as the victim stays logged in within N-Central. To take advantage of this, cookie could be stolen and the JSESSIONID can be captured. On its own this is not a surprising result; low security tools allow the cookie to roam from machine to machine. The JSESSION cookie can then be used on the attackers’ workstation by browsing to the victim’s NCentral server URL and replacing the JSESSIONID attribute value by the captured value. Expected behavior would be to check this against a second source and enforce at least a reauthentication or multi factor request as N-Central is a highly privileged service.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf | Exploit, Third Party Advisory | |
| cve@mitre.org | https://www.solarwindsmsp.com/products/n-central | Product, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.solarwindsmsp.com/products/n-central | Product, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| solarwinds | n-central | * |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:solarwinds:n-central:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5B3A0E0D-1539-4F2F-9541-BBECD11C4038",
"versionEndIncluding": "2020.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "SolarWinds N-central through 2020.1 allows session hijacking and requires user interaction or physical access. The N-Central JSESSIONID cookie attribute is not checked against multiple sources such as sourceip, MFA claim, etc. as long as the victim stays logged in within N-Central. To take advantage of this, cookie could be stolen and the JSESSIONID can be captured. On its own this is not a surprising result; low security tools allow the cookie to roam from machine to machine. The JSESSION cookie can then be used on the attackers\u2019 workstation by browsing to the victim\u2019s NCentral server URL and replacing the JSESSIONID attribute value by the captured value. Expected behavior would be to check this against a second source and enforce at least a reauthentication or multi factor request as N-Central is a highly privileged service."
},
{
"lang": "es",
"value": "SolarWinds N-central versiones hasta 2020.1, permite el secuestro de sesiones y requiere la interacci\u00f3n del usuario o acceso f\u00edsico.\u0026#xa0;El atributo de la cookie JSESSIONID de N-Central no se compara con varias fuentes, como sourceip, MFA claim, etc., siempre que la v\u00edctima permanezca conectada dentro de N-Central.\u0026#xa0;Para aprovechar esto, se podr\u00eda robar la cookie y capturar el JSESSIONID.\u0026#xa0;Por s\u00ed solo, este no es un resultado sorprendente;\u0026#xa0;las herramientas de baja seguridad permiten que la cookie se mueva de una m\u00e1quina a otra.\u0026#xa0;La cookie JSESSION se puede usar en la estaci\u00f3n de trabajo de los atacantes navegando hasta la URL del servidor NCentral de la v\u00edctima y reemplazando el valor del atributo JSESSIONID por el valor capturado.\u0026#xa0;El comportamiento esperado ser\u00eda comparar esto con una segunda fuente y hacer cumplir al menos una nueva autenticaci\u00f3n o una petici\u00f3n de m\u00faltiples factores, ya que N-Central es un servicio con muchos privilegios"
}
],
"id": "CVE-2020-15909",
"lastModified": "2026-06-17T02:57:23.380",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-10-19T13:15:13.267",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
},
{
"source": "cve@mitre.org",
"tags": [
"Product",
"Vendor Advisory"
],
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product",
"Vendor Advisory"
],
"url": "https://www.solarwindsmsp.com/products/n-central"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-384"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2020-25622 (GCVE-0-2020-25622)
Vulnerability from nvd – Published: 2020-12-16 14:07 – Updated: 2024-08-04 15:40
VLAI
EPSS
VEX
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows CSRF.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.solarwinds.com/SuccessCenter/s/ | x_refsource_MISC |
| https://ernw.de/en/publications.html | x_refsource_MISC |
| https://insinuator.net/2020/12/security-advisorie… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:40:35.479Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows CSRF."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T14:07:32.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25622",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows CSRF."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.solarwinds.com/SuccessCenter/s/",
"refsource": "MISC",
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"name": "https://ernw.de/en/publications.html",
"refsource": "MISC",
"url": "https://ernw.de/en/publications.html"
},
{
"name": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/",
"refsource": "MISC",
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25622",
"datePublished": "2020-12-16T14:07:32.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:40:35.479Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25621 (GCVE-0-2020-25621)
Vulnerability from nvd – Published: 2020-12-16 14:07 – Updated: 2024-08-04 15:40
VLAI
EPSS
VEX
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The local database does not require authentication: security is only based on ability to access a network interface. The database has keys and passwords.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.solarwinds.com/SuccessCenter/s/ | x_refsource_MISC |
| https://ernw.de/en/publications.html | x_refsource_MISC |
| https://insinuator.net/2020/12/security-advisorie… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:40:35.469Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The local database does not require authentication: security is only based on ability to access a network interface. The database has keys and passwords."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T14:07:07.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25621",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The local database does not require authentication: security is only based on ability to access a network interface. The database has keys and passwords."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.solarwinds.com/SuccessCenter/s/",
"refsource": "MISC",
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"name": "https://ernw.de/en/publications.html",
"refsource": "MISC",
"url": "https://ernw.de/en/publications.html"
},
{
"name": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/",
"refsource": "MISC",
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25621",
"datePublished": "2020-12-16T14:07:07.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:40:35.469Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25620 (GCVE-0-2020-25620)
Vulnerability from nvd – Published: 2020-12-16 14:04 – Updated: 2024-08-04 15:40
VLAI
EPSS
VEX
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. Hard-coded Credentials exist by default for local user accounts named support@n-able.com and nableadmin@n-able.com. These allow logins to the N-Central Administrative Console (NAC) and/or the regular web interface.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.solarwinds.com/SuccessCenter/s/ | x_refsource_MISC |
| https://ernw.de/en/publications.html | x_refsource_MISC |
| https://insinuator.net/2020/12/security-advisorie… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:40:35.433Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. Hard-coded Credentials exist by default for local user accounts named support@n-able.com and nableadmin@n-able.com. These allow logins to the N-Central Administrative Console (NAC) and/or the regular web interface."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T14:04:59.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25620",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. Hard-coded Credentials exist by default for local user accounts named support@n-able.com and nableadmin@n-able.com. These allow logins to the N-Central Administrative Console (NAC) and/or the regular web interface."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.solarwinds.com/SuccessCenter/s/",
"refsource": "MISC",
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"name": "https://ernw.de/en/publications.html",
"refsource": "MISC",
"url": "https://ernw.de/en/publications.html"
},
{
"name": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/",
"refsource": "MISC",
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25620",
"datePublished": "2020-12-16T14:04:59.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:40:35.433Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25619 (GCVE-0-2020-25619)
Vulnerability from nvd – Published: 2020-12-16 14:01 – Updated: 2024-08-04 15:33
VLAI
EPSS
VEX
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The SSH component does not restrict the Communication Channel to Intended Endpoints. An attacker can leverage an SSH feature (port forwarding with a temporary key pair) to access network services on the 127.0.0.1 interface, even though this feature was only intended for user-to-agent communication.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.solarwinds.com/SuccessCenter/s/ | x_refsource_MISC |
| https://ernw.de/en/publications.html | x_refsource_MISC |
| https://insinuator.net/2020/12/security-advisorie… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.827Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The SSH component does not restrict the Communication Channel to Intended Endpoints. An attacker can leverage an SSH feature (port forwarding with a temporary key pair) to access network services on the 127.0.0.1 interface, even though this feature was only intended for user-to-agent communication."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T14:01:36.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25619",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The SSH component does not restrict the Communication Channel to Intended Endpoints. An attacker can leverage an SSH feature (port forwarding with a temporary key pair) to access network services on the 127.0.0.1 interface, even though this feature was only intended for user-to-agent communication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.solarwinds.com/SuccessCenter/s/",
"refsource": "MISC",
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"name": "https://ernw.de/en/publications.html",
"refsource": "MISC",
"url": "https://ernw.de/en/publications.html"
},
{
"name": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/",
"refsource": "MISC",
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25619",
"datePublished": "2020-12-16T14:01:36.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:33:05.827Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25618 (GCVE-0-2020-25618)
Vulnerability from nvd – Published: 2020-12-16 13:56 – Updated: 2024-08-04 15:33
VLAI
EPSS
VEX
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The sudo configuration has incorrect access control because the nable web user account is effectively able to run arbitrary OS commands as root (i.e., the use of root privileges is not limited to specific programs listed in the sudoers file).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.solarwinds.com/SuccessCenter/s/ | x_refsource_MISC |
| https://ernw.de/en/publications.html | x_refsource_MISC |
| https://insinuator.net/2020/12/security-advisorie… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.761Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The sudo configuration has incorrect access control because the nable web user account is effectively able to run arbitrary OS commands as root (i.e., the use of root privileges is not limited to specific programs listed in the sudoers file)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T13:56:58.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25618",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The sudo configuration has incorrect access control because the nable web user account is effectively able to run arbitrary OS commands as root (i.e., the use of root privileges is not limited to specific programs listed in the sudoers file)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.solarwinds.com/SuccessCenter/s/",
"refsource": "MISC",
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"name": "https://ernw.de/en/publications.html",
"refsource": "MISC",
"url": "https://ernw.de/en/publications.html"
},
{
"name": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/",
"refsource": "MISC",
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25618",
"datePublished": "2020-12-16T13:56:58.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:33:05.761Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25617 (GCVE-0-2020-25617)
Vulnerability from nvd – Published: 2020-12-16 13:52 – Updated: 2024-08-04 15:33
VLAI
EPSS
VEX
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows Relative Path Traversal by an authenticated user of the N-Central Administration Console (NAC), leading to execution of OS commands as root.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.solarwinds.com/SuccessCenter/s/ | x_refsource_MISC |
| https://ernw.de/en/publications.html | x_refsource_MISC |
| https://insinuator.net/2020/12/security-advisorie… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.751Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows Relative Path Traversal by an authenticated user of the N-Central Administration Console (NAC), leading to execution of OS commands as root."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T13:52:03.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25617",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows Relative Path Traversal by an authenticated user of the N-Central Administration Console (NAC), leading to execution of OS commands as root."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.solarwinds.com/SuccessCenter/s/",
"refsource": "MISC",
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"name": "https://ernw.de/en/publications.html",
"refsource": "MISC",
"url": "https://ernw.de/en/publications.html"
},
{
"name": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/",
"refsource": "MISC",
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25617",
"datePublished": "2020-12-16T13:52:03.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:33:05.751Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-15910 (GCVE-0-2020-15910)
Vulnerability from nvd – Published: 2020-10-19 12:57 – Updated: 2024-08-04 13:30
VLAI
EPSS
VEX
Summary
SolarWinds N-Central version 12.3 GA and lower does not set the JSESSIONID attribute to HTTPOnly. This makes it possible to influence the cookie with javascript. An attacker could send the user to a prepared webpage or by influencing JavaScript to the extract the JESSIONID. This could then be forwarded to the attacker.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.solarwindsmsp.com/products/n-central | x_refsource_MISC |
| https://limenetworks.nl/wp-content/uploads/CVE-93… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:30:23.240Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SolarWinds N-Central version 12.3 GA and lower does not set the JSESSIONID attribute to HTTPOnly. This makes it possible to influence the cookie with javascript. An attacker could send the user to a prepared webpage or by influencing JavaScript to the extract the JESSIONID. This could then be forwarded to the attacker."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-19T18:39:28.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15910",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "SolarWinds N-Central version 12.3 GA and lower does not set the JSESSIONID attribute to HTTPOnly. This makes it possible to influence the cookie with javascript. An attacker could send the user to a prepared webpage or by influencing JavaScript to the extract the JESSIONID. This could then be forwarded to the attacker."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.solarwindsmsp.com/products/n-central",
"refsource": "MISC",
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"name": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf",
"refsource": "MISC",
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-15910",
"datePublished": "2020-10-19T12:57:26.000Z",
"dateReserved": "2020-07-23T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:30:23.240Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-15909 (GCVE-0-2020-15909)
Vulnerability from nvd – Published: 2020-10-19 12:57 – Updated: 2024-08-04 13:30
VLAI
EPSS
VEX
Summary
SolarWinds N-central through 2020.1 allows session hijacking and requires user interaction or physical access. The N-Central JSESSIONID cookie attribute is not checked against multiple sources such as sourceip, MFA claim, etc. as long as the victim stays logged in within N-Central. To take advantage of this, cookie could be stolen and the JSESSIONID can be captured. On its own this is not a surprising result; low security tools allow the cookie to roam from machine to machine. The JSESSION cookie can then be used on the attackers’ workstation by browsing to the victim’s NCentral server URL and replacing the JSESSIONID attribute value by the captured value. Expected behavior would be to check this against a second source and enforce at least a reauthentication or multi factor request as N-Central is a highly privileged service.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.solarwindsmsp.com/products/n-central | x_refsource_MISC |
| https://limenetworks.nl/wp-content/uploads/CVE-93… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:30:22.986Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SolarWinds N-central through 2020.1 allows session hijacking and requires user interaction or physical access. The N-Central JSESSIONID cookie attribute is not checked against multiple sources such as sourceip, MFA claim, etc. as long as the victim stays logged in within N-Central. To take advantage of this, cookie could be stolen and the JSESSIONID can be captured. On its own this is not a surprising result; low security tools allow the cookie to roam from machine to machine. The JSESSION cookie can then be used on the attackers\u2019 workstation by browsing to the victim\u2019s NCentral server URL and replacing the JSESSIONID attribute value by the captured value. Expected behavior would be to check this against a second source and enforce at least a reauthentication or multi factor request as N-Central is a highly privileged service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-19T18:34:21.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15909",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "SolarWinds N-central through 2020.1 allows session hijacking and requires user interaction or physical access. The N-Central JSESSIONID cookie attribute is not checked against multiple sources such as sourceip, MFA claim, etc. as long as the victim stays logged in within N-Central. To take advantage of this, cookie could be stolen and the JSESSIONID can be captured. On its own this is not a surprising result; low security tools allow the cookie to roam from machine to machine. The JSESSION cookie can then be used on the attackers\u2019 workstation by browsing to the victim\u2019s NCentral server URL and replacing the JSESSIONID attribute value by the captured value. Expected behavior would be to check this against a second source and enforce at least a reauthentication or multi factor request as N-Central is a highly privileged service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.solarwindsmsp.com/products/n-central",
"refsource": "MISC",
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"name": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf",
"refsource": "MISC",
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-15909",
"datePublished": "2020-10-19T12:57:26.000Z",
"dateReserved": "2020-07-23T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:30:22.986Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7984 (GCVE-0-2020-7984)
Vulnerability from nvd – Published: 2020-01-26 20:04 – Updated: 2024-08-04 09:48
VLAI
EPSS
VEX
Summary
SolarWinds N-central before 12.1 SP1 HF5 and 12.2 before SP1 HF2 allows remote attackers to retrieve cleartext domain admin credentials from the Agent & Probe settings, and obtain other sensitive information. The attacker can use a customer ID to self register and read any aspects of the agent/appliance configuration.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
8 references
| URL | Tags |
|---|---|
| https://blog.huntresslabs.com/validating-the-sola… | x_refsource_MISC |
| https://www.crn.com/news/managed-services/solarwi… | x_refsource_MISC |
| https://success.solarwindsmsp.com/kb/solarwinds_n… | x_refsource_MISC |
| https://community.solarwindsmsp.com/Support/Softw… | x_refsource_MISC |
| https://community.solarwindsmsp.com/Support/Softw… | x_refsource_MISC |
| https://github.com/flipflopfpv | x_refsource_MISC |
| https://packetstormsecurity.com/files/156033 | x_refsource_MISC |
| https://twitter.com/SecurityNewsbot/status/121972… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:48:24.994Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://blog.huntresslabs.com/validating-the-solarwinds-n-central-dumpster-diver-vulnerability-5e3a045982e5"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.crn.com/news/managed-services/solarwinds-rmm-tool-has-open-zero-day-exploit-huntress-labs"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://success.solarwindsmsp.com/kb/solarwinds_n-central/How-to-Expunge-credentials-for-Customer-levels-of-SolarWinds-N-central"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-2-SP1-HF2"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-1-SP1-HF5"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/flipflopfpv"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://packetstormsecurity.com/files/156033"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://twitter.com/SecurityNewsbot/status/1219722631898812416"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SolarWinds N-central before 12.1 SP1 HF5 and 12.2 before SP1 HF2 allows remote attackers to retrieve cleartext domain admin credentials from the Agent \u0026 Probe settings, and obtain other sensitive information. The attacker can use a customer ID to self register and read any aspects of the agent/appliance configuration."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-26T20:04:06.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://blog.huntresslabs.com/validating-the-solarwinds-n-central-dumpster-diver-vulnerability-5e3a045982e5"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.crn.com/news/managed-services/solarwinds-rmm-tool-has-open-zero-day-exploit-huntress-labs"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://success.solarwindsmsp.com/kb/solarwinds_n-central/How-to-Expunge-credentials-for-Customer-levels-of-SolarWinds-N-central"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-2-SP1-HF2"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-1-SP1-HF5"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/flipflopfpv"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://packetstormsecurity.com/files/156033"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://twitter.com/SecurityNewsbot/status/1219722631898812416"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-7984",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "SolarWinds N-central before 12.1 SP1 HF5 and 12.2 before SP1 HF2 allows remote attackers to retrieve cleartext domain admin credentials from the Agent \u0026 Probe settings, and obtain other sensitive information. The attacker can use a customer ID to self register and read any aspects of the agent/appliance configuration."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://blog.huntresslabs.com/validating-the-solarwinds-n-central-dumpster-diver-vulnerability-5e3a045982e5",
"refsource": "MISC",
"url": "https://blog.huntresslabs.com/validating-the-solarwinds-n-central-dumpster-diver-vulnerability-5e3a045982e5"
},
{
"name": "https://www.crn.com/news/managed-services/solarwinds-rmm-tool-has-open-zero-day-exploit-huntress-labs",
"refsource": "MISC",
"url": "https://www.crn.com/news/managed-services/solarwinds-rmm-tool-has-open-zero-day-exploit-huntress-labs"
},
{
"name": "https://success.solarwindsmsp.com/kb/solarwinds_n-central/How-to-Expunge-credentials-for-Customer-levels-of-SolarWinds-N-central",
"refsource": "MISC",
"url": "https://success.solarwindsmsp.com/kb/solarwinds_n-central/How-to-Expunge-credentials-for-Customer-levels-of-SolarWinds-N-central"
},
{
"name": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-2-SP1-HF2",
"refsource": "MISC",
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-2-SP1-HF2"
},
{
"name": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-1-SP1-HF5",
"refsource": "MISC",
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-1-SP1-HF5"
},
{
"name": "https://github.com/flipflopfpv",
"refsource": "MISC",
"url": "https://github.com/flipflopfpv"
},
{
"name": "https://packetstormsecurity.com/files/156033",
"refsource": "MISC",
"url": "https://packetstormsecurity.com/files/156033"
},
{
"name": "https://twitter.com/SecurityNewsbot/status/1219722631898812416",
"refsource": "MISC",
"url": "https://twitter.com/SecurityNewsbot/status/1219722631898812416"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-7984",
"datePublished": "2020-01-26T20:04:06.000Z",
"dateReserved": "2020-01-26T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:48:24.994Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25622 (GCVE-0-2020-25622)
Vulnerability from cvelistv5 – Published: 2020-12-16 14:07 – Updated: 2024-08-04 15:40
VLAI
EPSS
VEX
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows CSRF.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.solarwinds.com/SuccessCenter/s/ | x_refsource_MISC |
| https://ernw.de/en/publications.html | x_refsource_MISC |
| https://insinuator.net/2020/12/security-advisorie… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:40:35.479Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows CSRF."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T14:07:32.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25622",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows CSRF."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.solarwinds.com/SuccessCenter/s/",
"refsource": "MISC",
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"name": "https://ernw.de/en/publications.html",
"refsource": "MISC",
"url": "https://ernw.de/en/publications.html"
},
{
"name": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/",
"refsource": "MISC",
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25622",
"datePublished": "2020-12-16T14:07:32.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:40:35.479Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25621 (GCVE-0-2020-25621)
Vulnerability from cvelistv5 – Published: 2020-12-16 14:07 – Updated: 2024-08-04 15:40
VLAI
EPSS
VEX
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The local database does not require authentication: security is only based on ability to access a network interface. The database has keys and passwords.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.solarwinds.com/SuccessCenter/s/ | x_refsource_MISC |
| https://ernw.de/en/publications.html | x_refsource_MISC |
| https://insinuator.net/2020/12/security-advisorie… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:40:35.469Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The local database does not require authentication: security is only based on ability to access a network interface. The database has keys and passwords."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T14:07:07.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25621",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The local database does not require authentication: security is only based on ability to access a network interface. The database has keys and passwords."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.solarwinds.com/SuccessCenter/s/",
"refsource": "MISC",
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"name": "https://ernw.de/en/publications.html",
"refsource": "MISC",
"url": "https://ernw.de/en/publications.html"
},
{
"name": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/",
"refsource": "MISC",
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25621",
"datePublished": "2020-12-16T14:07:07.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:40:35.469Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25620 (GCVE-0-2020-25620)
Vulnerability from cvelistv5 – Published: 2020-12-16 14:04 – Updated: 2024-08-04 15:40
VLAI
EPSS
VEX
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. Hard-coded Credentials exist by default for local user accounts named support@n-able.com and nableadmin@n-able.com. These allow logins to the N-Central Administrative Console (NAC) and/or the regular web interface.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.solarwinds.com/SuccessCenter/s/ | x_refsource_MISC |
| https://ernw.de/en/publications.html | x_refsource_MISC |
| https://insinuator.net/2020/12/security-advisorie… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:40:35.433Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. Hard-coded Credentials exist by default for local user accounts named support@n-able.com and nableadmin@n-able.com. These allow logins to the N-Central Administrative Console (NAC) and/or the regular web interface."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T14:04:59.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25620",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. Hard-coded Credentials exist by default for local user accounts named support@n-able.com and nableadmin@n-able.com. These allow logins to the N-Central Administrative Console (NAC) and/or the regular web interface."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.solarwinds.com/SuccessCenter/s/",
"refsource": "MISC",
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"name": "https://ernw.de/en/publications.html",
"refsource": "MISC",
"url": "https://ernw.de/en/publications.html"
},
{
"name": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/",
"refsource": "MISC",
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25620",
"datePublished": "2020-12-16T14:04:59.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:40:35.433Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25619 (GCVE-0-2020-25619)
Vulnerability from cvelistv5 – Published: 2020-12-16 14:01 – Updated: 2024-08-04 15:33
VLAI
EPSS
VEX
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The SSH component does not restrict the Communication Channel to Intended Endpoints. An attacker can leverage an SSH feature (port forwarding with a temporary key pair) to access network services on the 127.0.0.1 interface, even though this feature was only intended for user-to-agent communication.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.solarwinds.com/SuccessCenter/s/ | x_refsource_MISC |
| https://ernw.de/en/publications.html | x_refsource_MISC |
| https://insinuator.net/2020/12/security-advisorie… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.827Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The SSH component does not restrict the Communication Channel to Intended Endpoints. An attacker can leverage an SSH feature (port forwarding with a temporary key pair) to access network services on the 127.0.0.1 interface, even though this feature was only intended for user-to-agent communication."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T14:01:36.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25619",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The SSH component does not restrict the Communication Channel to Intended Endpoints. An attacker can leverage an SSH feature (port forwarding with a temporary key pair) to access network services on the 127.0.0.1 interface, even though this feature was only intended for user-to-agent communication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.solarwinds.com/SuccessCenter/s/",
"refsource": "MISC",
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"name": "https://ernw.de/en/publications.html",
"refsource": "MISC",
"url": "https://ernw.de/en/publications.html"
},
{
"name": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/",
"refsource": "MISC",
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25619",
"datePublished": "2020-12-16T14:01:36.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:33:05.827Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25618 (GCVE-0-2020-25618)
Vulnerability from cvelistv5 – Published: 2020-12-16 13:56 – Updated: 2024-08-04 15:33
VLAI
EPSS
VEX
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The sudo configuration has incorrect access control because the nable web user account is effectively able to run arbitrary OS commands as root (i.e., the use of root privileges is not limited to specific programs listed in the sudoers file).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.solarwinds.com/SuccessCenter/s/ | x_refsource_MISC |
| https://ernw.de/en/publications.html | x_refsource_MISC |
| https://insinuator.net/2020/12/security-advisorie… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.761Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The sudo configuration has incorrect access control because the nable web user account is effectively able to run arbitrary OS commands as root (i.e., the use of root privileges is not limited to specific programs listed in the sudoers file)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T13:56:58.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25618",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The sudo configuration has incorrect access control because the nable web user account is effectively able to run arbitrary OS commands as root (i.e., the use of root privileges is not limited to specific programs listed in the sudoers file)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.solarwinds.com/SuccessCenter/s/",
"refsource": "MISC",
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"name": "https://ernw.de/en/publications.html",
"refsource": "MISC",
"url": "https://ernw.de/en/publications.html"
},
{
"name": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/",
"refsource": "MISC",
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25618",
"datePublished": "2020-12-16T13:56:58.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:33:05.761Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25617 (GCVE-0-2020-25617)
Vulnerability from cvelistv5 – Published: 2020-12-16 13:52 – Updated: 2024-08-04 15:33
VLAI
EPSS
VEX
Summary
An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows Relative Path Traversal by an authenticated user of the N-Central Administration Console (NAC), leading to execution of OS commands as root.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.solarwinds.com/SuccessCenter/s/ | x_refsource_MISC |
| https://ernw.de/en/publications.html | x_refsource_MISC |
| https://insinuator.net/2020/12/security-advisorie… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.751Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows Relative Path Traversal by an authenticated user of the N-Central Administration Console (NAC), leading to execution of OS commands as root."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T13:52:03.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ernw.de/en/publications.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25617",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SolarWinds N-Central 12.3.0.670. The AdvancedScripts HTTP endpoint allows Relative Path Traversal by an authenticated user of the N-Central Administration Console (NAC), leading to execution of OS commands as root."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.solarwinds.com/SuccessCenter/s/",
"refsource": "MISC",
"url": "https://support.solarwinds.com/SuccessCenter/s/"
},
{
"name": "https://ernw.de/en/publications.html",
"refsource": "MISC",
"url": "https://ernw.de/en/publications.html"
},
{
"name": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/",
"refsource": "MISC",
"url": "https://insinuator.net/2020/12/security-advisories-for-solarwinds-n-central/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25617",
"datePublished": "2020-12-16T13:52:03.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:33:05.751Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-15909 (GCVE-0-2020-15909)
Vulnerability from cvelistv5 – Published: 2020-10-19 12:57 – Updated: 2024-08-04 13:30
VLAI
EPSS
VEX
Summary
SolarWinds N-central through 2020.1 allows session hijacking and requires user interaction or physical access. The N-Central JSESSIONID cookie attribute is not checked against multiple sources such as sourceip, MFA claim, etc. as long as the victim stays logged in within N-Central. To take advantage of this, cookie could be stolen and the JSESSIONID can be captured. On its own this is not a surprising result; low security tools allow the cookie to roam from machine to machine. The JSESSION cookie can then be used on the attackers’ workstation by browsing to the victim’s NCentral server URL and replacing the JSESSIONID attribute value by the captured value. Expected behavior would be to check this against a second source and enforce at least a reauthentication or multi factor request as N-Central is a highly privileged service.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.solarwindsmsp.com/products/n-central | x_refsource_MISC |
| https://limenetworks.nl/wp-content/uploads/CVE-93… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:30:22.986Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SolarWinds N-central through 2020.1 allows session hijacking and requires user interaction or physical access. The N-Central JSESSIONID cookie attribute is not checked against multiple sources such as sourceip, MFA claim, etc. as long as the victim stays logged in within N-Central. To take advantage of this, cookie could be stolen and the JSESSIONID can be captured. On its own this is not a surprising result; low security tools allow the cookie to roam from machine to machine. The JSESSION cookie can then be used on the attackers\u2019 workstation by browsing to the victim\u2019s NCentral server URL and replacing the JSESSIONID attribute value by the captured value. Expected behavior would be to check this against a second source and enforce at least a reauthentication or multi factor request as N-Central is a highly privileged service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-19T18:34:21.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15909",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "SolarWinds N-central through 2020.1 allows session hijacking and requires user interaction or physical access. The N-Central JSESSIONID cookie attribute is not checked against multiple sources such as sourceip, MFA claim, etc. as long as the victim stays logged in within N-Central. To take advantage of this, cookie could be stolen and the JSESSIONID can be captured. On its own this is not a surprising result; low security tools allow the cookie to roam from machine to machine. The JSESSION cookie can then be used on the attackers\u2019 workstation by browsing to the victim\u2019s NCentral server URL and replacing the JSESSIONID attribute value by the captured value. Expected behavior would be to check this against a second source and enforce at least a reauthentication or multi factor request as N-Central is a highly privileged service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.solarwindsmsp.com/products/n-central",
"refsource": "MISC",
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"name": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf",
"refsource": "MISC",
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-15909",
"datePublished": "2020-10-19T12:57:26.000Z",
"dateReserved": "2020-07-23T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:30:22.986Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-15910 (GCVE-0-2020-15910)
Vulnerability from cvelistv5 – Published: 2020-10-19 12:57 – Updated: 2024-08-04 13:30
VLAI
EPSS
VEX
Summary
SolarWinds N-Central version 12.3 GA and lower does not set the JSESSIONID attribute to HTTPOnly. This makes it possible to influence the cookie with javascript. An attacker could send the user to a prepared webpage or by influencing JavaScript to the extract the JESSIONID. This could then be forwarded to the attacker.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.solarwindsmsp.com/products/n-central | x_refsource_MISC |
| https://limenetworks.nl/wp-content/uploads/CVE-93… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:30:23.240Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SolarWinds N-Central version 12.3 GA and lower does not set the JSESSIONID attribute to HTTPOnly. This makes it possible to influence the cookie with javascript. An attacker could send the user to a prepared webpage or by influencing JavaScript to the extract the JESSIONID. This could then be forwarded to the attacker."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-19T18:39:28.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-15910",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "SolarWinds N-Central version 12.3 GA and lower does not set the JSESSIONID attribute to HTTPOnly. This makes it possible to influence the cookie with javascript. An attacker could send the user to a prepared webpage or by influencing JavaScript to the extract the JESSIONID. This could then be forwarded to the attacker."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.solarwindsmsp.com/products/n-central",
"refsource": "MISC",
"url": "https://www.solarwindsmsp.com/products/n-central"
},
{
"name": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf",
"refsource": "MISC",
"url": "https://limenetworks.nl/wp-content/uploads/CVE-934261-v-1.2.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-15910",
"datePublished": "2020-10-19T12:57:26.000Z",
"dateReserved": "2020-07-23T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:30:23.240Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7984 (GCVE-0-2020-7984)
Vulnerability from cvelistv5 – Published: 2020-01-26 20:04 – Updated: 2024-08-04 09:48
VLAI
EPSS
VEX
Summary
SolarWinds N-central before 12.1 SP1 HF5 and 12.2 before SP1 HF2 allows remote attackers to retrieve cleartext domain admin credentials from the Agent & Probe settings, and obtain other sensitive information. The attacker can use a customer ID to self register and read any aspects of the agent/appliance configuration.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
8 references
| URL | Tags |
|---|---|
| https://blog.huntresslabs.com/validating-the-sola… | x_refsource_MISC |
| https://www.crn.com/news/managed-services/solarwi… | x_refsource_MISC |
| https://success.solarwindsmsp.com/kb/solarwinds_n… | x_refsource_MISC |
| https://community.solarwindsmsp.com/Support/Softw… | x_refsource_MISC |
| https://community.solarwindsmsp.com/Support/Softw… | x_refsource_MISC |
| https://github.com/flipflopfpv | x_refsource_MISC |
| https://packetstormsecurity.com/files/156033 | x_refsource_MISC |
| https://twitter.com/SecurityNewsbot/status/121972… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:48:24.994Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://blog.huntresslabs.com/validating-the-solarwinds-n-central-dumpster-diver-vulnerability-5e3a045982e5"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.crn.com/news/managed-services/solarwinds-rmm-tool-has-open-zero-day-exploit-huntress-labs"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://success.solarwindsmsp.com/kb/solarwinds_n-central/How-to-Expunge-credentials-for-Customer-levels-of-SolarWinds-N-central"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-2-SP1-HF2"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-1-SP1-HF5"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/flipflopfpv"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://packetstormsecurity.com/files/156033"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://twitter.com/SecurityNewsbot/status/1219722631898812416"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SolarWinds N-central before 12.1 SP1 HF5 and 12.2 before SP1 HF2 allows remote attackers to retrieve cleartext domain admin credentials from the Agent \u0026 Probe settings, and obtain other sensitive information. The attacker can use a customer ID to self register and read any aspects of the agent/appliance configuration."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-26T20:04:06.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://blog.huntresslabs.com/validating-the-solarwinds-n-central-dumpster-diver-vulnerability-5e3a045982e5"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.crn.com/news/managed-services/solarwinds-rmm-tool-has-open-zero-day-exploit-huntress-labs"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://success.solarwindsmsp.com/kb/solarwinds_n-central/How-to-Expunge-credentials-for-Customer-levels-of-SolarWinds-N-central"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-2-SP1-HF2"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-1-SP1-HF5"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/flipflopfpv"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://packetstormsecurity.com/files/156033"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://twitter.com/SecurityNewsbot/status/1219722631898812416"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-7984",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "SolarWinds N-central before 12.1 SP1 HF5 and 12.2 before SP1 HF2 allows remote attackers to retrieve cleartext domain admin credentials from the Agent \u0026 Probe settings, and obtain other sensitive information. The attacker can use a customer ID to self register and read any aspects of the agent/appliance configuration."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://blog.huntresslabs.com/validating-the-solarwinds-n-central-dumpster-diver-vulnerability-5e3a045982e5",
"refsource": "MISC",
"url": "https://blog.huntresslabs.com/validating-the-solarwinds-n-central-dumpster-diver-vulnerability-5e3a045982e5"
},
{
"name": "https://www.crn.com/news/managed-services/solarwinds-rmm-tool-has-open-zero-day-exploit-huntress-labs",
"refsource": "MISC",
"url": "https://www.crn.com/news/managed-services/solarwinds-rmm-tool-has-open-zero-day-exploit-huntress-labs"
},
{
"name": "https://success.solarwindsmsp.com/kb/solarwinds_n-central/How-to-Expunge-credentials-for-Customer-levels-of-SolarWinds-N-central",
"refsource": "MISC",
"url": "https://success.solarwindsmsp.com/kb/solarwinds_n-central/How-to-Expunge-credentials-for-Customer-levels-of-SolarWinds-N-central"
},
{
"name": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-2-SP1-HF2",
"refsource": "MISC",
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-2-SP1-HF2"
},
{
"name": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-1-SP1-HF5",
"refsource": "MISC",
"url": "https://community.solarwindsmsp.com/Support/Software-Downloads/MSP-N-Central/MSP-N-central-12-1-SP1-HF5"
},
{
"name": "https://github.com/flipflopfpv",
"refsource": "MISC",
"url": "https://github.com/flipflopfpv"
},
{
"name": "https://packetstormsecurity.com/files/156033",
"refsource": "MISC",
"url": "https://packetstormsecurity.com/files/156033"
},
{
"name": "https://twitter.com/SecurityNewsbot/status/1219722631898812416",
"refsource": "MISC",
"url": "https://twitter.com/SecurityNewsbot/status/1219722631898812416"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-7984",
"datePublished": "2020-01-26T20:04:06.000Z",
"dateReserved": "2020-01-26T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:48:24.994Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}