Search criteria
10 vulnerabilities found for modicon_quantum_plc by schneider-electric
CVE-2013-0664 (GCVE-0-2013-0664)
Vulnerability from nvd – Published: 2013-04-04 10:00 – Updated: 2024-09-16 19:30
VLAI?
Summary
The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T14:33:05.668Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-04-04T10:00:00Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2013-0664",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"
},
{
"name": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper"
},
{
"name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2013-0664",
"datePublished": "2013-04-04T10:00:00Z",
"dateReserved": "2012-12-19T00:00:00Z",
"dateUpdated": "2024-09-16T19:30:03.282Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-0663 (GCVE-0-2013-0663)
Vulnerability from nvd – Published: 2013-04-04 10:00 – Updated: 2024-08-06 14:33
VLAI?
Summary
Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T14:33:05.456Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "44678",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/44678/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2013-01-23T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-05-23T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "44678",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/44678/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2013-0663",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "44678",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/44678/"
},
{
"name": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"
},
{
"name": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper"
},
{
"name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2013-0663",
"datePublished": "2013-04-04T10:00:00",
"dateReserved": "2012-12-19T00:00:00",
"dateUpdated": "2024-08-06T14:33:05.456Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2012-0931 (GCVE-0-2012-0931)
Vulnerability from nvd – Published: 2012-01-28 01:00 – Updated: 2024-08-06 18:38
VLAI?
Summary
Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T18:38:15.007Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-unity-dos(72586)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72586"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-01-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-21T14:04:12",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-unity-dos(72586)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72586"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2012-0931",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-unity-dos(72586)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72586"
},
{
"name": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2012-0931",
"datePublished": "2012-01-28T01:00:00",
"dateReserved": "2012-01-27T00:00:00",
"dateUpdated": "2024-08-06T18:38:15.007Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2012-0930 (GCVE-0-2012-0930)
Vulnerability from nvd – Published: 2012-01-28 01:00 – Updated: 2024-08-06 18:38
VLAI?
Summary
Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T18:38:15.056Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-unspec-xss(72590)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72590"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-01-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-21T14:06:08",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-unspec-xss(72590)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72590"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2012-0930",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-unspec-xss(72590)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72590"
},
{
"name": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2012-0930",
"datePublished": "2012-01-28T01:00:00",
"dateReserved": "2012-01-27T00:00:00",
"dateUpdated": "2024-08-06T18:38:15.056Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2012-0929 (GCVE-0-2012-0929)
Vulnerability from nvd – Published: 2012-01-28 01:00 – Updated: 2024-08-06 18:38
VLAI?
Summary
Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T18:38:15.010Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-http-dos(72588)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72588"
},
{
"name": "schneider-modicon-ftp-dos(72589)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72589"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-01-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-21T14:00:05",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-http-dos(72588)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72588"
},
{
"name": "schneider-modicon-ftp-dos(72589)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72589"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2012-0929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-http-dos(72588)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72588"
},
{
"name": "schneider-modicon-ftp-dos(72589)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72589"
},
{
"name": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2012-0929",
"datePublished": "2012-01-28T01:00:00",
"dateReserved": "2012-01-27T00:00:00",
"dateUpdated": "2024-08-06T18:38:15.010Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-0664 (GCVE-0-2013-0664)
Vulnerability from cvelistv5 – Published: 2013-04-04 10:00 – Updated: 2024-09-16 19:30
VLAI?
Summary
The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T14:33:05.668Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-04-04T10:00:00Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2013-0664",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"
},
{
"name": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper"
},
{
"name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2013-0664",
"datePublished": "2013-04-04T10:00:00Z",
"dateReserved": "2012-12-19T00:00:00Z",
"dateUpdated": "2024-09-16T19:30:03.282Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-0663 (GCVE-0-2013-0663)
Vulnerability from cvelistv5 – Published: 2013-04-04 10:00 – Updated: 2024-08-06 14:33
VLAI?
Summary
Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T14:33:05.456Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "44678",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/44678/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2013-01-23T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-05-23T09:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "44678",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/44678/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2013-0663",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "44678",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/44678/"
},
{
"name": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/download/ww/en/details/35081317-Vulnerability-Disclosure-for-Quantum-Premium-and-M340/"
},
{
"name": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/download/ww/en/file/36555639-SEVD-2013-023-01.pdf/?fileName=SEVD-2013-023-01.pdf\u0026reference=SEVD-2013-023-01\u0026docType=Technical-paper"
},
{
"name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-077-01A.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2013-0663",
"datePublished": "2013-04-04T10:00:00",
"dateReserved": "2012-12-19T00:00:00",
"dateUpdated": "2024-08-06T14:33:05.456Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2012-0931 (GCVE-0-2012-0931)
Vulnerability from cvelistv5 – Published: 2012-01-28 01:00 – Updated: 2024-08-06 18:38
VLAI?
Summary
Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T18:38:15.007Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-unity-dos(72586)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72586"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-01-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-21T14:04:12",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-unity-dos(72586)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72586"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2012-0931",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-unity-dos(72586)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72586"
},
{
"name": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2012-0931",
"datePublished": "2012-01-28T01:00:00",
"dateReserved": "2012-01-27T00:00:00",
"dateUpdated": "2024-08-06T18:38:15.007Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2012-0930 (GCVE-0-2012-0930)
Vulnerability from cvelistv5 – Published: 2012-01-28 01:00 – Updated: 2024-08-06 18:38
VLAI?
Summary
Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T18:38:15.056Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-unspec-xss(72590)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72590"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-01-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-21T14:06:08",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-unspec-xss(72590)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72590"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2012-0930",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-unspec-xss(72590)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72590"
},
{
"name": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2012-0930",
"datePublished": "2012-01-28T01:00:00",
"dateReserved": "2012-01-27T00:00:00",
"dateUpdated": "2024-08-06T18:38:15.056Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2012-0929 (GCVE-0-2012-0929)
Vulnerability from cvelistv5 – Published: 2012-01-28 01:00 – Updated: 2024-08-06 18:38
VLAI?
Summary
Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T18:38:15.010Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-http-dos(72588)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72588"
},
{
"name": "schneider-modicon-ftp-dos(72589)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72589"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-01-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-21T14:00:05",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-http-dos(72588)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72588"
},
{
"name": "schneider-modicon-ftp-dos(72589)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72589"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2012-0929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the (1) FTP server or (2) HTTP server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-12-020-03.pdf"
},
{
"name": "51605",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/51605"
},
{
"name": "47723",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/47723"
},
{
"name": "schneider-modicon-http-dos(72588)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72588"
},
{
"name": "schneider-modicon-ftp-dos(72589)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72589"
},
{
"name": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-12-020-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2012-0929",
"datePublished": "2012-01-28T01:00:00",
"dateReserved": "2012-01-27T00:00:00",
"dateUpdated": "2024-08-06T18:38:15.010Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}