    6 vulnerabilities found for modbus_serial_driver by schneider-electric

    CVE-2020-7523 (GCVE-0-2020-7523)

    Vulnerability from nvd – Published: 2020-08-31 16:11 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.
    Severity
    No CVSS data available.
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0 Affected: Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.426Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269: Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-08-31T16:11:46.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7523",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-269: Improper Privilege Management"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7523",
        "datePublished": "2020-08-31T16:11:46.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.426Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7824 (GCVE-0-2018-7824)

    Vulnerability from nvd – Published: 2019-05-22 19:27 – Updated: 2024-08-05 06:37
    VLAI
    Summary
    An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files.
    Severity
    No CVSS data available.
    CWE
    • CWE-610 - Externally Controlled Reference to a Resource (CWE-610)
    Assigner
    References
    Impacted products
    Vendor Product Version
    Schneider Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) Affected: Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior
    Affected: For 32-bit Windows OS:V2.17 IE 27 and prior
    Affected: and as part of the Driver Suite version:V14.12 and prior)
    Create a notification for this product.
    Date Public
    2019-04-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:37:59.163Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior)",
              "vendor": "Schneider",
              "versions": [
                {
                  "status": "affected",
                  "version": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior"
                },
                {
                  "status": "affected",
                  "version": "For 32-bit Windows OS:V2.17 IE 27 and prior"
                },
                {
                  "status": "affected",
                  "version": "and as part of the Driver Suite version:V14.12 and prior)"
                }
              ]
            }
          ],
          "datePublic": "2019-04-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-610",
                  "description": "Externally Controlled Reference to a Resource (CWE-610)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-05-22T19:27:44.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2018-7824",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior"
                              },
                              {
                                "version_value": "For 32-bit Windows OS:V2.17 IE 27 and prior"
                              },
                              {
                                "version_value": "and as part of the Driver Suite version:V14.12 and prior)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Externally Controlled Reference to a Resource (CWE-610)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2018-7824",
        "datePublished": "2019-05-22T19:27:44.000Z",
        "dateReserved": "2018-03-08T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:37:59.163Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-0662 (GCVE-0-2013-0662)

    Vulnerability from nvd – Published: 2014-03-28 19:00 – Updated: 2024-08-06 14:33
    VLAI
    Summary
    Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2014-03-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T14:33:05.415Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
              },
              {
                "name": "45219",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/45219/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
              },
              {
                "name": "66500",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/66500"
              },
              {
                "name": "45220",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/45220/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-03-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-08-22T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
            },
            {
              "name": "45219",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/45219/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
            },
            {
              "name": "66500",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/66500"
            },
            {
              "name": "45220",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/45220/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2013-0662",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01",
                  "refsource": "CONFIRM",
                  "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
                },
                {
                  "name": "45219",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/45219/"
                },
                {
                  "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01",
                  "refsource": "MISC",
                  "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
                },
                {
                  "name": "66500",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/66500"
                },
                {
                  "name": "45220",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/45220/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2013-0662",
        "datePublished": "2014-03-28T19:00:00.000Z",
        "dateReserved": "2012-12-19T00:00:00.000Z",
        "dateUpdated": "2024-08-06T14:33:05.415Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-7523 (GCVE-0-2020-7523)

    Vulnerability from cvelistv5 – Published: 2020-08-31 16:11 – Updated: 2024-08-04 09:33
    VLAI
    Summary
    Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.
    Severity
    No CVSS data available.
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    References
    Impacted products
    Vendor Product Version
    n/a Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0 Affected: Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:33:19.426Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269: Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-08-31T16:11:46.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2020-7523",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-269: Improper Privilege Management"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/",
                  "refsource": "MISC",
                  "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2020-7523",
        "datePublished": "2020-08-31T16:11:46.000Z",
        "dateReserved": "2020-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-04T09:33:19.426Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-7824 (GCVE-0-2018-7824)

    Vulnerability from cvelistv5 – Published: 2019-05-22 19:27 – Updated: 2024-08-05 06:37
    VLAI
    Summary
    An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files.
    Severity
    No CVSS data available.
    CWE
    • CWE-610 - Externally Controlled Reference to a Resource (CWE-610)
    Assigner
    References
    Impacted products
    Vendor Product Version
    Schneider Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) Affected: Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior
    Affected: For 32-bit Windows OS:V2.17 IE 27 and prior
    Affected: and as part of the Driver Suite version:V14.12 and prior)
    Create a notification for this product.
    Date Public
    2019-04-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:37:59.163Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior)",
              "vendor": "Schneider",
              "versions": [
                {
                  "status": "affected",
                  "version": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior"
                },
                {
                  "status": "affected",
                  "version": "For 32-bit Windows OS:V2.17 IE 27 and prior"
                },
                {
                  "status": "affected",
                  "version": "and as part of the Driver Suite version:V14.12 and prior)"
                }
              ]
            }
          ],
          "datePublic": "2019-04-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-610",
                  "description": "Externally Controlled Reference to a Resource (CWE-610)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-05-22T19:27:44.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@schneider-electric.com",
              "ID": "CVE-2018-7824",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior)",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior"
                              },
                              {
                                "version_value": "For 32-bit Windows OS:V2.17 IE 27 and prior"
                              },
                              {
                                "version_value": "and as part of the Driver Suite version:V14.12 and prior)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schneider"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Externally Controlled Reference to a Resource (CWE-610)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/",
                  "refsource": "CONFIRM",
                  "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2018-7824",
        "datePublished": "2019-05-22T19:27:44.000Z",
        "dateReserved": "2018-03-08T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:37:59.163Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-0662 (GCVE-0-2013-0662)

    Vulnerability from cvelistv5 – Published: 2014-03-28 19:00 – Updated: 2024-08-06 14:33
    VLAI
    Summary
    Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2014-03-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T14:33:05.415Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
              },
              {
                "name": "45219",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/45219/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
              },
              {
                "name": "66500",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/66500"
              },
              {
                "name": "45220",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/45220/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2014-03-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-08-22T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
            },
            {
              "name": "45219",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/45219/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
            },
            {
              "name": "66500",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/66500"
            },
            {
              "name": "45220",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/45220/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2013-0662",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01",
                  "refsource": "CONFIRM",
                  "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
                },
                {
                  "name": "45219",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/45219/"
                },
                {
                  "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01",
                  "refsource": "MISC",
                  "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
                },
                {
                  "name": "66500",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/66500"
                },
                {
                  "name": "45220",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/45220/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2013-0662",
        "datePublished": "2014-03-28T19:00:00.000Z",
        "dateReserved": "2012-12-19T00:00:00.000Z",
        "dateUpdated": "2024-08-06T14:33:05.415Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }