Search criteria

6 vulnerabilities found for modbus_serial_driver by schneider-electric

CVE-2020-7523 (GCVE-0-2020-7523)

Vulnerability from nvd – Published: 2020-08-31 16:11 – Updated: 2024-08-04 09:33
VLAI?
Summary
Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.
Severity ?
No CVSS data available.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
n/a Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0 Affected: Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.426Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269: Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-08-31T16:11:46.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2020-7523",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269: Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2020-7523",
    "datePublished": "2020-08-31T16:11:46.000Z",
    "dateReserved": "2020-01-21T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:33:19.426Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7824 (GCVE-0-2018-7824)

Vulnerability from nvd – Published: 2019-05-22 19:27 – Updated: 2024-08-05 06:37
VLAI?
Summary
An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files.
Severity ?
No CVSS data available.
CWE
  • CWE-610 - Externally Controlled Reference to a Resource (CWE-610)
Assigner
References
Impacted products
Vendor Product Version
Schneider Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) Affected: Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior
Affected: For 32-bit Windows OS:V2.17 IE 27 and prior
Affected: and as part of the Driver Suite version:V14.12 and prior)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.163Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior)",
          "vendor": "Schneider",
          "versions": [
            {
              "status": "affected",
              "version": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior"
            },
            {
              "status": "affected",
              "version": "For 32-bit Windows OS:V2.17 IE 27 and prior"
            },
            {
              "status": "affected",
              "version": "and as part of the Driver Suite version:V14.12 and prior)"
            }
          ]
        }
      ],
      "datePublic": "2019-04-09T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-610",
              "description": "Externally Controlled Reference to a Resource (CWE-610)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-22T19:27:44.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2018-7824",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior"
                          },
                          {
                            "version_value": "For 32-bit Windows OS:V2.17 IE 27 and prior"
                          },
                          {
                            "version_value": "and as part of the Driver Suite version:V14.12 and prior)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Externally Controlled Reference to a Resource (CWE-610)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7824",
    "datePublished": "2019-05-22T19:27:44.000Z",
    "dateReserved": "2018-03-08T00:00:00.000Z",
    "dateUpdated": "2024-08-05T06:37:59.163Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-0662 (GCVE-0-2013-0662)

Vulnerability from nvd – Published: 2014-03-28 19:00 – Updated: 2024-08-06 14:33
VLAI?
Summary
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T14:33:05.415Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
          },
          {
            "name": "45219",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/45219/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
          },
          {
            "name": "66500",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/66500"
          },
          {
            "name": "45220",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/45220/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2014-03-27T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-08-22T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
        },
        {
          "name": "45219",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/45219/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
        },
        {
          "name": "66500",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/66500"
        },
        {
          "name": "45220",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/45220/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-0662",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01",
              "refsource": "CONFIRM",
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
            },
            {
              "name": "45219",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/45219/"
            },
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
            },
            {
              "name": "66500",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/66500"
            },
            {
              "name": "45220",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/45220/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-0662",
    "datePublished": "2014-03-28T19:00:00.000Z",
    "dateReserved": "2012-12-19T00:00:00.000Z",
    "dateUpdated": "2024-08-06T14:33:05.415Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7523 (GCVE-0-2020-7523)

Vulnerability from cvelistv5 – Published: 2020-08-31 16:11 – Updated: 2024-08-04 09:33
VLAI?
Summary
Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.
Severity ?
No CVSS data available.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
n/a Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0 Affected: Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.426Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269: Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-08-31T16:11:46.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2020-7523",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Schneider Electric Modbus Serial Driver (64 bits) versions prior to V3.20 IE 30, Schneider Electric Modbus Serial Driver (32 bits) versions prior to V2.20 IE 30, and Schneider Electric Modbus Driver Suite versions prior to V14.15.0.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269: Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2020-7523",
    "datePublished": "2020-08-31T16:11:46.000Z",
    "dateReserved": "2020-01-21T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:33:19.426Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7824 (GCVE-0-2018-7824)

Vulnerability from cvelistv5 – Published: 2019-05-22 19:27 – Updated: 2024-08-05 06:37
VLAI?
Summary
An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files.
Severity ?
No CVSS data available.
CWE
  • CWE-610 - Externally Controlled Reference to a Resource (CWE-610)
Assigner
References
Impacted products
Vendor Product Version
Schneider Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) Affected: Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior
Affected: For 32-bit Windows OS:V2.17 IE 27 and prior
Affected: and as part of the Driver Suite version:V14.12 and prior)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.163Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior)",
          "vendor": "Schneider",
          "versions": [
            {
              "status": "affected",
              "version": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior"
            },
            {
              "status": "affected",
              "version": "For 32-bit Windows OS:V2.17 IE 27 and prior"
            },
            {
              "status": "affected",
              "version": "and as part of the Driver Suite version:V14.12 and prior)"
            }
          ]
        }
      ],
      "datePublic": "2019-04-09T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-610",
              "description": "Externally Controlled Reference to a Resource (CWE-610)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-22T19:27:44.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2018-7824",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior"
                          },
                          {
                            "version_value": "For 32-bit Windows OS:V2.17 IE 27 and prior"
                          },
                          {
                            "version_value": "and as part of the Driver Suite version:V14.12 and prior)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit Windows OS:V3.17 IE 37 and prior , For 32-bit Windows OS:V2.17 IE 27 and prior, and as part of the Driver Suite version:V14.12 and prior) which could allow write access to system files available only to users with SYSTEM privilege or other important user files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Externally Controlled Reference to a Resource (CWE-610)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-099-01/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7824",
    "datePublished": "2019-05-22T19:27:44.000Z",
    "dateReserved": "2018-03-08T00:00:00.000Z",
    "dateUpdated": "2024-08-05T06:37:59.163Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-0662 (GCVE-0-2013-0662)

Vulnerability from cvelistv5 – Published: 2014-03-28 19:00 – Updated: 2024-08-06 14:33
VLAI?
Summary
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T14:33:05.415Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
          },
          {
            "name": "45219",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/45219/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
          },
          {
            "name": "66500",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/66500"
          },
          {
            "name": "45220",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/45220/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2014-03-27T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-08-22T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
        },
        {
          "name": "45219",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/45219/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
        },
        {
          "name": "66500",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/66500"
        },
        {
          "name": "45220",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/45220/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-0662",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01",
              "refsource": "CONFIRM",
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
            },
            {
              "name": "45219",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/45219/"
            },
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
            },
            {
              "name": "66500",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/66500"
            },
            {
              "name": "45220",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/45220/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-0662",
    "datePublished": "2014-03-28T19:00:00.000Z",
    "dateReserved": "2012-12-19T00:00:00.000Z",
    "dateUpdated": "2024-08-06T14:33:05.415Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}