Search criteria

26 vulnerabilities found for mendix by mendix

CVE-2024-50313 (GCVE-0-2024-50313)

Vulnerability from nvd – Published: 2024-11-12 12:49 – Updated: 2025-08-27 21:33
VLAI?
Summary
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions < V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions < V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions < V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures.
CWE
  • CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-50313",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T14:16:20.945053Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T21:33:05.238Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.16.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.12.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.6.15",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.24.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions \u003c V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions \u003c V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions \u003c V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions \u003c V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-362",
              "description": "CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:16:45.329Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-914892.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-50313",
    "datePublished": "2024-11-12T12:49:54.803Z",
    "dateReserved": "2024-10-22T15:35:51.132Z",
    "dateUpdated": "2025-08-27T21:33:05.238Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-23835 (GCVE-0-2023-23835)

Vulnerability from nvd – Published: 2023-02-14 10:36 – Updated: 2025-03-20 16:25
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.34), Mendix Applications using Mendix 8 (All versions < V8.18.23), Mendix Applications using Mendix 9 (All versions < V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions < V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.15). Some of the Mendix runtime API’s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors.
CWE
  • CWE-284 - Improper Access Control
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:42:27.044Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-252808.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-23835",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-20T16:18:41.457961Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-20T16:25:54.732Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.34"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.23"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.22.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 9 (V9.12)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.12.10"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 9 (V9.18)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.18.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 9 (V9.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.15"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.34), Mendix Applications using Mendix 8 (All versions \u003c V8.18.23), Mendix Applications using Mendix 9 (All versions \u003c V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions \u003c V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.15). Some of the Mendix runtime API\u2019s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-15T09:24:58.910Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-252808.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-23835",
    "datePublished": "2023-02-14T10:36:23.615Z",
    "dateReserved": "2023-01-18T10:28:31.589Z",
    "dateUpdated": "2025-03-20T16:25:54.732Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34466 (GCVE-0-2022-34466)

Vulnerability from nvd – Published: 2022-07-12 10:07 – Updated: 2024-08-03 09:15
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 9 (All versions >= V9.11 < V9.15), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.3). An expression injection vulnerability was discovered in the Workflow subsystem of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information in a certain configuration.
Severity ?
No CVSS data available.
CWE
  • CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:15:15.104Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V9.11 \u003c V9.15"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.12)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.12.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 9 (All versions \u003e= V9.11 \u003c V9.15), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.3). An expression injection vulnerability was discovered in the Workflow subsystem of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information in a certain configuration."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:07:22",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-34466",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V9.11 \u003c V9.15"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.12)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.12.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 9 (All versions \u003e= V9.11 \u003c V9.15), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.3). An expression injection vulnerability was discovered in the Workflow subsystem of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information in a certain configuration."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34466",
    "datePublished": "2022-07-12T10:07:22",
    "dateReserved": "2022-06-24T00:00:00",
    "dateUpdated": "2024-08-03T09:15:15.104Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-31257 (GCVE-0-2022-31257)

Vulnerability from nvd – Published: 2022-07-12 10:06 – Updated: 2024-08-03 07:11
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). In case of access to an active user session in an application that is built with an affected version, it’s possible to change that user’s password bypassing password validations within a Mendix application. This could allow to set weak passwords.
Severity ?
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:11:39.898Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.31"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.18"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.14.0"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.12)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.12.2"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.12"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). In case of access to an active user session in an application that is built with an affected version, it\u2019s possible to change that user\u2019s password bypassing password validations within a Mendix application. This could allow to set weak passwords."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:06:42",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-31257",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.31"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.18"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.14.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.12)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.12.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.6)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.12"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). In case of access to an active user session in an application that is built with an affected version, it\u2019s possible to change that user\u2019s password bypassing password validations within a Mendix application. This could allow to set weak passwords."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-31257",
    "datePublished": "2022-07-12T10:06:43",
    "dateReserved": "2022-05-20T00:00:00",
    "dateUpdated": "2024-08-03T07:11:39.898Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-27241 (GCVE-0-2022-27241)

Vulnerability from nvd – Published: 2022-04-12 09:08 – Updated: 2024-08-03 05:25
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information.
Severity ?
No CVSS data available.
CWE
  • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:25:32.284Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.31"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.18"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.11"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.12"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:06:37",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-27241",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.31"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.18"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.6)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.12"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-27241",
    "datePublished": "2022-04-12T09:08:00",
    "dateReserved": "2022-03-18T00:00:00",
    "dateUpdated": "2024-08-03T05:25:32.284Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25650 (GCVE-0-2022-25650)

Vulnerability from nvd – Published: 2022-04-12 09:07 – Updated: 2024-08-03 04:42
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.27), Mendix Applications using Mendix 8 (All versions < V8.18.14), Mendix Applications using Mendix 9 (All versions < V9.12.0), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.3). When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field.
Severity ?
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:50.611Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.27"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.14"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.12.0"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.27), Mendix Applications using Mendix 8 (All versions \u003c V8.18.14), Mendix Applications using Mendix 9 (All versions \u003c V9.12.0), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.3). When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:42",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-25650",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.27"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.14"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.6)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.27), Mendix Applications using Mendix 8 (All versions \u003c V8.18.14), Mendix Applications using Mendix 9 (All versions \u003c V9.12.0), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.3). When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-25650",
    "datePublished": "2022-04-12T09:07:42",
    "dateReserved": "2022-02-22T00:00:00",
    "dateUpdated": "2024-08-03T04:42:50.611Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26317 (GCVE-0-2022-26317)

Vulnerability from nvd – Published: 2022-03-08 11:31 – Updated: 2024-08-03 05:03
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.29). When returning the result of a completed Microflow execution call the affected framework does not correctly verify, if the request was initially made by the user requesting the result. Together with predictable identifiers for Microflow execution calls, this could allow a malicious attacker to retrieve information about arbitrary Microflow execution calls made by users within the affected system.
Severity ?
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Siemens Mendix Applications using Mendix 7 Affected: All versions < V7.23.29
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.443Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-415938.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.29"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.29). When returning the result of a completed Microflow execution call the affected framework does not correctly verify, if the request was initially made by the user requesting the result. Together with predictable identifiers for Microflow execution calls, this could allow a malicious attacker to retrieve information about arbitrary Microflow execution calls made by users within the affected system."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-08T11:31:37",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-415938.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-26317",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.29"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.29). When returning the result of a completed Microflow execution call the affected framework does not correctly verify, if the request was initially made by the user requesting the result. Together with predictable identifiers for Microflow execution calls, this could allow a malicious attacker to retrieve information about arbitrary Microflow execution calls made by users within the affected system."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-415938.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-415938.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-26317",
    "datePublished": "2022-03-08T11:31:37",
    "dateReserved": "2022-02-28T00:00:00",
    "dateUpdated": "2024-08-03T05:03:32.443Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-24309 (GCVE-0-2022-24309)

Vulnerability from nvd – Published: 2022-03-08 11:31 – Updated: 2024-10-08 08:39
VLAI?
Summary
A vulnerability has been identified in Mendix Runtime V7 (All versions < V7.23.29), Mendix Runtime V8 (All versions < V8.18.16), Mendix Runtime V9 (All versions < V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data.
CWE
  • CWE-284 - Improper Access Control
Assigner
Impacted products
Vendor Product Version
Siemens Mendix Runtime V7 Affected: 0 , < V7.23.29 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:07:02.516Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.23.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.18.16",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V7 (All versions \u003c V7.23.29), Mendix Runtime V8 (All versions \u003c V8.18.16), Mendix Runtime V9 (All versions \u003c V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:51.939Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-24309",
    "datePublished": "2022-03-08T11:31:29",
    "dateReserved": "2022-02-02T00:00:00",
    "dateUpdated": "2024-10-08T08:39:51.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-42026 (GCVE-0-2021-42026)

Vulnerability from nvd – Published: 2021-11-09 11:32 – Updated: 2024-08-04 03:22
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions < V8.18.13), Mendix Applications using Mendix 9 (All versions < V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control read access for certain client actions. This could allow authenticated attackers to retrieve the changedDate attribute of arbitrary objects, even when they don't have read access to them.
Severity ?
No CVSS data available.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:22:25.755Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.13"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions \u003c V8.18.13), Mendix Applications using Mendix 9 (All versions \u003c V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control read access for certain client actions. This could allow authenticated attackers to retrieve the changedDate attribute of arbitrary objects, even when they don\u0027t have read access to them."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863: Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-09T11:32:17",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-42026",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.13"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions \u003c V8.18.13), Mendix Applications using Mendix 9 (All versions \u003c V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control read access for certain client actions. This could allow authenticated attackers to retrieve the changedDate attribute of arbitrary objects, even when they don\u0027t have read access to them."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-863: Incorrect Authorization"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-42026",
    "datePublished": "2021-11-09T11:32:17",
    "dateReserved": "2021-10-06T00:00:00",
    "dateUpdated": "2024-08-04T03:22:25.755Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-42025 (GCVE-0-2021-42025)

Vulnerability from nvd – Published: 2021-11-09 11:32 – Updated: 2024-08-04 03:22
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions < V8.18.13), Mendix Applications using Mendix 9 (All versions < V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects in some cases, regardless whether they have write access to it.
Severity ?
No CVSS data available.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:22:25.924Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.13"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions \u003c V8.18.13), Mendix Applications using Mendix 9 (All versions \u003c V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects in some cases, regardless whether they have write access to it."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863: Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-09T11:32:16",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-42025",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.13"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions \u003c V8.18.13), Mendix Applications using Mendix 9 (All versions \u003c V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects in some cases, regardless whether they have write access to it."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-863: Incorrect Authorization"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-42025",
    "datePublished": "2021-11-09T11:32:16",
    "dateReserved": "2021-10-06T00:00:00",
    "dateUpdated": "2024-08-04T03:22:25.924Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-42015 (GCVE-0-2021-42015)

Vulnerability from nvd – Published: 2021-11-09 11:32 – Updated: 2024-08-04 03:22
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.26), Mendix Applications using Mendix 8 (All versions < V8.18.12), Mendix Applications using Mendix 9 (All versions < V9.6.1). Applications built with affected versions of Mendix Studio Pro do not prevent file documents from being cached when files are opened or downloaded using a browser. This could allow a local attacker to read those documents by exploring the browser cache.
Severity ?
No CVSS data available.
CWE
  • CWE-525 - Use of Web Browser Cache Containing Sensitive Information
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:22:25.646Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-338732.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.26"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.12"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.26), Mendix Applications using Mendix 8 (All versions \u003c V8.18.12), Mendix Applications using Mendix 9 (All versions \u003c V9.6.1). Applications built with affected versions of Mendix Studio Pro do not prevent file documents from being cached when files are opened or downloaded using a browser. This could allow a local attacker to read those documents by exploring the browser cache."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-525",
              "description": "CWE-525: Use of Web Browser Cache Containing Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-09T11:32:14",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-338732.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-42015",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.26"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.12"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.26), Mendix Applications using Mendix 8 (All versions \u003c V8.18.12), Mendix Applications using Mendix 9 (All versions \u003c V9.6.1). Applications built with affected versions of Mendix Studio Pro do not prevent file documents from being cached when files are opened or downloaded using a browser. This could allow a local attacker to read those documents by exploring the browser cache."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-525: Use of Web Browser Cache Containing Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-338732.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-338732.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-42015",
    "datePublished": "2021-11-09T11:32:14",
    "dateReserved": "2021-10-06T00:00:00",
    "dateUpdated": "2024-08-04T03:22:25.646Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27394 (GCVE-0-2021-27394)

Vulnerability from nvd – Published: 2021-04-16 20:00 – Updated: 2024-08-03 20:48
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.19), Mendix Applications using Mendix 8 (All versions < V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions < V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions < V8.6.9), Mendix Applications using Mendix 9 (All versions < V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges.
Severity ?
No CVSS data available.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:16.703Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.19"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.17.0"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8 (V8.12)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.12.5"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8 (V8.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.6.9"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.19), Mendix Applications using Mendix 8 (All versions \u003c V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions \u003c V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions \u003c V8.6.9), Mendix Applications using Mendix 9 (All versions \u003c V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269: Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-16T20:00:14",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-27394",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.17.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8 (V8.12)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.12.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8 (V8.6)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.6.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.19), Mendix Applications using Mendix 8 (All versions \u003c V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions \u003c V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions \u003c V8.6.9), Mendix Applications using Mendix 9 (All versions \u003c V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269: Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-27394",
    "datePublished": "2021-04-16T20:00:14",
    "dateReserved": "2021-02-18T00:00:00",
    "dateUpdated": "2024-08-03T20:48:16.703Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-12996 (GCVE-0-2019-12996)

Vulnerability from nvd – Published: 2019-09-10 18:43 – Updated: 2024-08-04 23:41
VLAI?
Summary
In Mendix 7.23.5 and earlier, issue in XML import mappings allow DOCTYPE declarations in the XML input that is potentially unsafe.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:41:10.054Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.mendix.com/releasenotes/studio-pro/7.23#7236"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Mendix 7.23.5 and earlier, issue in XML import mappings allow DOCTYPE declarations in the XML input that is potentially unsafe."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-11T16:06:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.mendix.com/releasenotes/studio-pro/7.23#7236"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2019-12996",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Mendix 7.23.5 and earlier, issue in XML import mappings allow DOCTYPE declarations in the XML input that is potentially unsafe."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.mendix.com/releasenotes/studio-pro/7.23#7236",
              "refsource": "CONFIRM",
              "url": "https://docs.mendix.com/releasenotes/studio-pro/7.23#7236"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2019-12996",
    "datePublished": "2019-09-10T18:43:06",
    "dateReserved": "2019-06-28T00:00:00",
    "dateUpdated": "2024-08-04T23:41:10.054Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-50313 (GCVE-0-2024-50313)

Vulnerability from cvelistv5 – Published: 2024-11-12 12:49 – Updated: 2025-08-27 21:33
VLAI?
Summary
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions < V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions < V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions < V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures.
CWE
  • CWE-362 - Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition')
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-50313",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T14:16:20.945053Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T21:33:05.238Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.16.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.12",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.12.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V10.6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.6.15",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.24.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions \u003c V10.16.0 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.12 (All versions \u003c V10.12.7 only if the basic authentication mechanism is used by the application), Mendix Runtime V10.6 (All versions \u003c V10.6.15 only if the basic authentication mechanism is used by the application), Mendix Runtime V8 (All versions only if the basic authentication mechanism is used by the application), Mendix Runtime V9 (All versions \u003c V9.24.29 only if the basic authentication mechanism is used by the application). The basic authentication implementation of affected applications contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-362",
              "description": "CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization (\u0027Race Condition\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:16:45.329Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-914892.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-50313",
    "datePublished": "2024-11-12T12:49:54.803Z",
    "dateReserved": "2024-10-22T15:35:51.132Z",
    "dateUpdated": "2025-08-27T21:33:05.238Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-23835 (GCVE-0-2023-23835)

Vulnerability from cvelistv5 – Published: 2023-02-14 10:36 – Updated: 2025-03-20 16:25
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.34), Mendix Applications using Mendix 8 (All versions < V8.18.23), Mendix Applications using Mendix 9 (All versions < V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions < V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.15). Some of the Mendix runtime API’s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors.
CWE
  • CWE-284 - Improper Access Control
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:42:27.044Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-252808.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-23835",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-20T16:18:41.457961Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-20T16:25:54.732Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.34"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.23"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.22.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 9 (V9.12)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.12.10"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 9 (V9.18)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.18.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Applications using Mendix 9 (V9.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.15"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.34), Mendix Applications using Mendix 8 (All versions \u003c V8.18.23), Mendix Applications using Mendix 9 (All versions \u003c V9.22.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.10), Mendix Applications using Mendix 9 (V9.18) (All versions \u003c V9.18.4), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.15). Some of the Mendix runtime API\u2019s allow attackers to bypass XPath constraints and retrieve information using XPath queries that trigger errors."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-15T09:24:58.910Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-252808.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-23835",
    "datePublished": "2023-02-14T10:36:23.615Z",
    "dateReserved": "2023-01-18T10:28:31.589Z",
    "dateUpdated": "2025-03-20T16:25:54.732Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34466 (GCVE-0-2022-34466)

Vulnerability from cvelistv5 – Published: 2022-07-12 10:07 – Updated: 2024-08-03 09:15
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 9 (All versions >= V9.11 < V9.15), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.3). An expression injection vulnerability was discovered in the Workflow subsystem of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information in a certain configuration.
Severity ?
No CVSS data available.
CWE
  • CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:15:15.104Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V9.11 \u003c V9.15"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.12)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.12.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 9 (All versions \u003e= V9.11 \u003c V9.15), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.3). An expression injection vulnerability was discovered in the Workflow subsystem of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information in a certain configuration."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:07:22",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-34466",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V9.11 \u003c V9.15"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.12)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.12.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 9 (All versions \u003e= V9.11 \u003c V9.15), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.3). An expression injection vulnerability was discovered in the Workflow subsystem of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information in a certain configuration."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-492173.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34466",
    "datePublished": "2022-07-12T10:07:22",
    "dateReserved": "2022-06-24T00:00:00",
    "dateUpdated": "2024-08-03T09:15:15.104Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-31257 (GCVE-0-2022-31257)

Vulnerability from cvelistv5 – Published: 2022-07-12 10:06 – Updated: 2024-08-03 07:11
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). In case of access to an active user session in an application that is built with an affected version, it’s possible to change that user’s password bypassing password validations within a Mendix application. This could allow to set weak passwords.
Severity ?
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:11:39.898Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.31"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.18"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.14.0"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.12)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.12.2"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.12"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). In case of access to an active user session in an application that is built with an affected version, it\u2019s possible to change that user\u2019s password bypassing password validations within a Mendix application. This could allow to set weak passwords."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:06:42",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-31257",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.31"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.18"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.14.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.12)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.12.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.6)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.12"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). In case of access to an active user session in an application that is built with an affected version, it\u2019s possible to change that user\u2019s password bypassing password validations within a Mendix application. This could allow to set weak passwords."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-31257",
    "datePublished": "2022-07-12T10:06:43",
    "dateReserved": "2022-05-20T00:00:00",
    "dateUpdated": "2024-08-03T07:11:39.898Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-27241 (GCVE-0-2022-27241)

Vulnerability from cvelistv5 – Published: 2022-04-12 09:08 – Updated: 2024-08-03 05:25
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information.
Severity ?
No CVSS data available.
CWE
  • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:25:32.284Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.31"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.18"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.11"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.12"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:06:37",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-27241",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.31"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.18"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.6)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.12"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-27241",
    "datePublished": "2022-04-12T09:08:00",
    "dateReserved": "2022-03-18T00:00:00",
    "dateUpdated": "2024-08-03T05:25:32.284Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25650 (GCVE-0-2022-25650)

Vulnerability from cvelistv5 – Published: 2022-04-12 09:07 – Updated: 2024-08-03 04:42
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.27), Mendix Applications using Mendix 8 (All versions < V8.18.14), Mendix Applications using Mendix 9 (All versions < V9.12.0), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.3). When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field.
Severity ?
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:50.611Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.27"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.14"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.12.0"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9 (V9.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.27), Mendix Applications using Mendix 8 (All versions \u003c V8.18.14), Mendix Applications using Mendix 9 (All versions \u003c V9.12.0), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.3). When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:42",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-25650",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.27"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.14"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.12.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9 (V9.6)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.27), Mendix Applications using Mendix 8 (All versions \u003c V8.18.14), Mendix Applications using Mendix 9 (All versions \u003c V9.12.0), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.3). When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-870917.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-25650",
    "datePublished": "2022-04-12T09:07:42",
    "dateReserved": "2022-02-22T00:00:00",
    "dateUpdated": "2024-08-03T04:42:50.611Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26317 (GCVE-0-2022-26317)

Vulnerability from cvelistv5 – Published: 2022-03-08 11:31 – Updated: 2024-08-03 05:03
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.29). When returning the result of a completed Microflow execution call the affected framework does not correctly verify, if the request was initially made by the user requesting the result. Together with predictable identifiers for Microflow execution calls, this could allow a malicious attacker to retrieve information about arbitrary Microflow execution calls made by users within the affected system.
Severity ?
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Siemens Mendix Applications using Mendix 7 Affected: All versions < V7.23.29
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.443Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-415938.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.29"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.29). When returning the result of a completed Microflow execution call the affected framework does not correctly verify, if the request was initially made by the user requesting the result. Together with predictable identifiers for Microflow execution calls, this could allow a malicious attacker to retrieve information about arbitrary Microflow execution calls made by users within the affected system."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-08T11:31:37",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-415938.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-26317",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.29"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.29). When returning the result of a completed Microflow execution call the affected framework does not correctly verify, if the request was initially made by the user requesting the result. Together with predictable identifiers for Microflow execution calls, this could allow a malicious attacker to retrieve information about arbitrary Microflow execution calls made by users within the affected system."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-415938.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-415938.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-26317",
    "datePublished": "2022-03-08T11:31:37",
    "dateReserved": "2022-02-28T00:00:00",
    "dateUpdated": "2024-08-03T05:03:32.443Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-24309 (GCVE-0-2022-24309)

Vulnerability from cvelistv5 – Published: 2022-03-08 11:31 – Updated: 2024-10-08 08:39
VLAI?
Summary
A vulnerability has been identified in Mendix Runtime V7 (All versions < V7.23.29), Mendix Runtime V8 (All versions < V8.18.16), Mendix Runtime V9 (All versions < V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data.
CWE
  • CWE-284 - Improper Access Control
Assigner
Impacted products
Vendor Product Version
Siemens Mendix Runtime V7 Affected: 0 , < V7.23.29 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:07:02.516Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.23.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.18.16",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V7 (All versions \u003c V7.23.29), Mendix Runtime V8 (All versions \u003c V8.18.16), Mendix Runtime V9 (All versions \u003c V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:51.939Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-24309",
    "datePublished": "2022-03-08T11:31:29",
    "dateReserved": "2022-02-02T00:00:00",
    "dateUpdated": "2024-10-08T08:39:51.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-42026 (GCVE-0-2021-42026)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:32 – Updated: 2024-08-04 03:22
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions < V8.18.13), Mendix Applications using Mendix 9 (All versions < V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control read access for certain client actions. This could allow authenticated attackers to retrieve the changedDate attribute of arbitrary objects, even when they don't have read access to them.
Severity ?
No CVSS data available.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:22:25.755Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.13"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions \u003c V8.18.13), Mendix Applications using Mendix 9 (All versions \u003c V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control read access for certain client actions. This could allow authenticated attackers to retrieve the changedDate attribute of arbitrary objects, even when they don\u0027t have read access to them."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863: Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-09T11:32:17",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-42026",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.13"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions \u003c V8.18.13), Mendix Applications using Mendix 9 (All versions \u003c V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control read access for certain client actions. This could allow authenticated attackers to retrieve the changedDate attribute of arbitrary objects, even when they don\u0027t have read access to them."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-863: Incorrect Authorization"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-42026",
    "datePublished": "2021-11-09T11:32:17",
    "dateReserved": "2021-10-06T00:00:00",
    "dateUpdated": "2024-08-04T03:22:25.755Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-42025 (GCVE-0-2021-42025)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:32 – Updated: 2024-08-04 03:22
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions < V8.18.13), Mendix Applications using Mendix 9 (All versions < V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects in some cases, regardless whether they have write access to it.
Severity ?
No CVSS data available.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:22:25.924Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.13"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions \u003c V8.18.13), Mendix Applications using Mendix 9 (All versions \u003c V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects in some cases, regardless whether they have write access to it."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863: Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-09T11:32:16",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-42025",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.13"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 8 (All versions \u003c V8.18.13), Mendix Applications using Mendix 9 (All versions \u003c V9.6.2). Applications built with affected versions of Mendix Studio Pro do not properly control write access for certain client actions. This could allow authenticated attackers to manipulate the content of System.FileDocument objects in some cases, regardless whether they have write access to it."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-863: Incorrect Authorization"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-42025",
    "datePublished": "2021-11-09T11:32:16",
    "dateReserved": "2021-10-06T00:00:00",
    "dateUpdated": "2024-08-04T03:22:25.924Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-42015 (GCVE-0-2021-42015)

Vulnerability from cvelistv5 – Published: 2021-11-09 11:32 – Updated: 2024-08-04 03:22
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.26), Mendix Applications using Mendix 8 (All versions < V8.18.12), Mendix Applications using Mendix 9 (All versions < V9.6.1). Applications built with affected versions of Mendix Studio Pro do not prevent file documents from being cached when files are opened or downloaded using a browser. This could allow a local attacker to read those documents by exploring the browser cache.
Severity ?
No CVSS data available.
CWE
  • CWE-525 - Use of Web Browser Cache Containing Sensitive Information
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:22:25.646Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-338732.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.26"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.18.12"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.6.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.26), Mendix Applications using Mendix 8 (All versions \u003c V8.18.12), Mendix Applications using Mendix 9 (All versions \u003c V9.6.1). Applications built with affected versions of Mendix Studio Pro do not prevent file documents from being cached when files are opened or downloaded using a browser. This could allow a local attacker to read those documents by exploring the browser cache."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-525",
              "description": "CWE-525: Use of Web Browser Cache Containing Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-09T11:32:14",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-338732.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-42015",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.26"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.18.12"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.6.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.26), Mendix Applications using Mendix 8 (All versions \u003c V8.18.12), Mendix Applications using Mendix 9 (All versions \u003c V9.6.1). Applications built with affected versions of Mendix Studio Pro do not prevent file documents from being cached when files are opened or downloaded using a browser. This could allow a local attacker to read those documents by exploring the browser cache."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-525: Use of Web Browser Cache Containing Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-338732.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-338732.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-42015",
    "datePublished": "2021-11-09T11:32:14",
    "dateReserved": "2021-10-06T00:00:00",
    "dateUpdated": "2024-08-04T03:22:25.646Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27394 (GCVE-0-2021-27394)

Vulnerability from cvelistv5 – Published: 2021-04-16 20:00 – Updated: 2024-08-03 20:48
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.19), Mendix Applications using Mendix 8 (All versions < V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions < V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions < V8.6.9), Mendix Applications using Mendix 9 (All versions < V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges.
Severity ?
No CVSS data available.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:16.703Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.19"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.17.0"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8 (V8.12)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.12.5"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 8 (V8.6)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.6.9"
            }
          ]
        },
        {
          "product": "Mendix Applications using Mendix 9",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.19), Mendix Applications using Mendix 8 (All versions \u003c V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions \u003c V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions \u003c V8.6.9), Mendix Applications using Mendix 9 (All versions \u003c V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269: Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-16T20:00:14",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-27394",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.17.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8 (V8.12)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.12.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 8 (V8.6)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.6.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mendix Applications using Mendix 9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.19), Mendix Applications using Mendix 8 (All versions \u003c V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions \u003c V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions \u003c V8.6.9), Mendix Applications using Mendix 9 (All versions \u003c V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269: Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-875726.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-27394",
    "datePublished": "2021-04-16T20:00:14",
    "dateReserved": "2021-02-18T00:00:00",
    "dateUpdated": "2024-08-03T20:48:16.703Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-12996 (GCVE-0-2019-12996)

Vulnerability from cvelistv5 – Published: 2019-09-10 18:43 – Updated: 2024-08-04 23:41
VLAI?
Summary
In Mendix 7.23.5 and earlier, issue in XML import mappings allow DOCTYPE declarations in the XML input that is potentially unsafe.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:41:10.054Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.mendix.com/releasenotes/studio-pro/7.23#7236"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Mendix 7.23.5 and earlier, issue in XML import mappings allow DOCTYPE declarations in the XML input that is potentially unsafe."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-11T16:06:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.mendix.com/releasenotes/studio-pro/7.23#7236"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2019-12996",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Mendix 7.23.5 and earlier, issue in XML import mappings allow DOCTYPE declarations in the XML input that is potentially unsafe."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.mendix.com/releasenotes/studio-pro/7.23#7236",
              "refsource": "CONFIRM",
              "url": "https://docs.mendix.com/releasenotes/studio-pro/7.23#7236"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2019-12996",
    "datePublished": "2019-09-10T18:43:06",
    "dateReserved": "2019-06-28T00:00:00",
    "dateUpdated": "2024-08-04T23:41:10.054Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}