    4 vulnerabilities found for logiq_e_firmware by gehealthcare

    CVE-2024-1630 (GCVE-0-2024-1630)

    Vulnerability from nvd – Published: 2024-05-14 16:55 – Updated: 2024-08-22 17:51
    VLAI
    Title
    Path traversal vulnerability in “getAllFolderContents” function of Common Service Desktop, a GE HealthCare ultrasound device component
    Summary
    Path traversal vulnerability in “getAllFolderContents” function of Common Service Desktop, a GE HealthCare ultrasound device component
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 19:43 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    GEHC CNA
    CNA scorecard – unranked: 0 records in the last 180 days, 10 needed details
    References
    Impacted products
    Vendor Product Version
    GE HealthCare Venue Affected: R1
    Affected: R2
    Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.3 (custom)
    Create a notification for this product.
    GE HealthCare Venue Go Affected: R2
    Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.3 (custom)
    Create a notification for this product.
    GE HealthCare Venue Fit Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.3 (custom)
    Create a notification for this product.
    GE HealthCare LOGIQ e Affected: R7 , ≤ R9.1.4 (custom)
    Affected: R8 , ≤ R10.1.3 (custom)
    Affected: R9 , ≤ R11.0.3 (custom)
    Create a notification for this product.
    GE HealthCare LOGIQ He Affected: 0 , ≤ R9.3.1 (custom)
    Create a notification for this product.
    GE HealthCare Vivid E Affected: E95 , < 206 (custom)
    Affected: E90 , < 206 (custom)
    Affected: E80 , < 206 (custom)
    Create a notification for this product.
    GE HealthCare Vivid T Affected: T8 , < 206 (custom)
    Affected: T9 , < 206 (custom)
    Create a notification for this product.
    GE HealthCare Vivid iq Affected: 0 , < 206 (custom)
    Create a notification for this product.
    GE HealthCare Voluson Expert 16 Affected: 0
    Affected: BT24
    Create a notification for this product.
    GE HealthCare Voluson Expert 18 Affected: 0
    Affected: BT24
    Create a notification for this product.
    GE HealthCare Voluson Expert 22 Affected: 0
    Affected: BT24
    Create a notification for this product.
    GE HealthCare Voluson SWIFT Affected: 0
    Affected: BT24
    Create a notification for this product.
    GE HealthCare LOGIQ E10 Affected: 0 , < R3.2.0 (custom)
    Create a notification for this product.
    GE HealthCare LOGIQ E10s Affected: 0 , < R3.2.0 (custom)
    Create a notification for this product.
    GE HealthCare LOGIQ Fortis Affected: 0 , < R3.2.0 (custom)
    Create a notification for this product.
    gehealthcare venue_firmware Affected: r1
    Affected: r2
    Affected: r3 , ≤ r3.3 (custom)
    Affected: r4 , ≤ r4.3 (custom)
        cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare venue_go_firmware Affected: r2
    Affected: r3 , ≤ r3.3 (custom)
    Affected: r4 , ≤ r4.3 (custom)
        cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare venue_fit_firmware Affected: r3 , ≤ r3.3 (custom)
    Affected: r4 , ≤ r4.3 (custom)
        cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_e_firmware Affected: r7 , ≤ r9.1.4 (custom)
    Affected: r8 , ≤ r10.1.3 (custom)
    Affected: r9 , ≤ r11.0.3 (custom)
        cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_he_firmware Affected: 0 , ≤ r9.3.1 (custom)
        cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_e_firmware Affected: e95 , < 206 (custom)
    Affected: e90 , < 206 (custom)
    Affected: e80 , < 206 (custom)
        cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_t_firmware Affected: t8 , < 206 (custom)
    Affected: t9 , < 206 (custom)
        cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_iq_firmware Affected: 0 , < 206 (custom)
        cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare voluson_expert_16 Affected: 0
    Affected: bt24
        cpe:2.3:a:gehealthcare:voluson_expert_16:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare voluson_expert_18 Affected: 0
    Affected: bt24
        cpe:2.3:a:gehealthcare:voluson_expert_18:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare voluson_expert_22 Affected: 0
    Affected: bt24
        cpe:2.3:a:gehealthcare:voluson_expert_22:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare voluson_swift Affected: 0
    Affected: bt24
        cpe:2.3:a:gehealthcare:voluson_swift:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_e10 Affected: 0 , < r3.2.0 (custom)
        cpe:2.3:a:gehealthcare:logiq_e10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_e10s Affected: 0 , < r3.2.0 (custom)
        cpe:2.3:a:gehealthcare:logiq_e10s:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_fortis Affected: 0 , < r3.2.0 (custom)
        cpe:2.3:a:gehealthcare:logiq_fortis:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:48:21.818Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://securityupdate.gehealthcare.com/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "venue_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "r1"
                  },
                  {
                    "status": "affected",
                    "version": "r2"
                  },
                  {
                    "lessThanOrEqual": "r3.3",
                    "status": "affected",
                    "version": "r3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "r4.3",
                    "status": "affected",
                    "version": "r4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "venue_go_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "r2"
                  },
                  {
                    "lessThanOrEqual": "r3.3",
                    "status": "affected",
                    "version": "r3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "r4.3",
                    "status": "affected",
                    "version": "r4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "venue_fit_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThanOrEqual": "r3.3",
                    "status": "affected",
                    "version": "r3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "r4.3",
                    "status": "affected",
                    "version": "r4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "logiq_e_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThanOrEqual": "r9.1.4",
                    "status": "affected",
                    "version": "r7",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "r10.1.3",
                    "status": "affected",
                    "version": "r8",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "r11.0.3",
                    "status": "affected",
                    "version": "r9",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "logiq_he_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThanOrEqual": "r9.3.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vivid_e_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "e95",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "e90",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "e80",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vivid_t_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "t8",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "t9",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vivid_iq_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:voluson_expert_16:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "voluson_expert_16",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  },
                  {
                    "status": "affected",
                    "version": "bt24"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:voluson_expert_18:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "voluson_expert_18",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  },
                  {
                    "status": "affected",
                    "version": "bt24"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:voluson_expert_22:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "voluson_expert_22",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  },
                  {
                    "status": "affected",
                    "version": "bt24"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:voluson_swift:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "voluson_swift",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  },
                  {
                    "status": "affected",
                    "version": "bt24"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:logiq_e10:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "logiq_e10",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "r3.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:logiq_e10s:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "logiq_e10s",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "r3.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:logiq_fortis:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "logiq_fortis",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "r3.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1630",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T19:43:01.721848Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-22T17:51:14.776Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Venue",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "R1"
                },
                {
                  "status": "affected",
                  "version": "R2"
                },
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.3",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Venue Go",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "R2"
                },
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.3",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Venue Fit",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.3",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ e",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R9.1.4",
                  "status": "affected",
                  "version": "R7",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R10.1.3",
                  "status": "affected",
                  "version": "R8",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R11.0.3",
                  "status": "affected",
                  "version": "R9",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ He",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R9.3.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid E",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E95",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E90",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E80",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid T",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "T8",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "T9",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid iq",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Voluson Expert 16",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                },
                {
                  "status": "affected",
                  "version": "BT24"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Voluson Expert 18",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                },
                {
                  "status": "affected",
                  "version": "BT24"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Voluson Expert 22",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                },
                {
                  "status": "affected",
                  "version": "BT24"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Voluson SWIFT",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                },
                {
                  "status": "affected",
                  "version": "BT24"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ E10",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "R3.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ E10s",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "R3.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ Fortis",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "R3.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component"
                }
              ],
              "value": "Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-14T16:55:56.853Z",
            "orgId": "171caf72-b841-4e04-a68e-93493aff2b94",
            "shortName": "GEHC"
          },
          "references": [
            {
              "url": "https://securityupdate.gehealthcare.com/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94",
        "assignerShortName": "GEHC",
        "cveId": "CVE-2024-1630",
        "datePublished": "2024-05-14T16:55:56.853Z",
        "dateReserved": "2024-02-19T15:28:03.794Z",
        "dateUpdated": "2024-08-22T17:51:14.776Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-1486 (GCVE-0-2024-1486)

    Vulnerability from nvd – Published: 2024-05-14 15:10 – Updated: 2024-08-16 18:15
    VLAI
    Title
    Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices
    Summary
    Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-12 14:08 UTC
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    GEHC CNA
    CNA scorecard – unranked: 0 records in the last 180 days, 10 needed details
    References
    Impacted products
    Vendor Product Version
    GE HealthCare Venue Affected: R1
    Affected: R2
    Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.2 (custom)
    Create a notification for this product.
    GE HealthCare Venue Go Affected: R2
    Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.2 (custom)
    Create a notification for this product.
    GE HealthCare Venue Fit Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.2 (custom)
    Create a notification for this product.
    GE HealthCare LOGIQ e Affected: R7 , ≤ R9.1.4 (custom)
    Affected: R8 , ≤ R10.1.3 (custom)
    Affected: R9 , ≤ R11.0.2 (custom)
    Create a notification for this product.
    GE HealthCare LOGIQ He Affected: 0 , ≤ R9.3.1 (custom)
    Create a notification for this product.
    GE HealthCare Vivid E Affected: E95 , < 206 (custom)
    Affected: E90 , < 206 (custom)
    Affected: E80 , < 206 (custom)
    Affected: E9 113.2 , ≤ 113.2 (custom)
    Create a notification for this product.
    GE HealthCare Vivid S Affected: 70N , < 206 (custom)
    Affected: 60N , < 206 (custom)
    Create a notification for this product.
    GE HealthCare Vivid T Affected: T8 , < 206 (custom)
    Affected: T9 , < 206 (custom)
    Create a notification for this product.
    GE HealthCare Vivid iq Affected: 0 , < 206 (custom)
    Create a notification for this product.
    GE HealthCare Invenia ABUS Affected: 1.2.3
    Create a notification for this product.
    GE HealthCare Invenia ABUS 2.0 Affected: 0 , < 2.2.9 (custom)
    Create a notification for this product.
    gehealthcare venue_firmware Affected: R1
    Affected: R2
    Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.2 (custom)
        cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare venue_go_firmware Affected: R2
    Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.2 (custom)
        cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare venue_fit_firmware Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.2 (custom)
        cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_e_firmware Affected: R7 , ≤ R9.1.4 (custom)
    Affected: R8 , ≤ R10.1.3 (custom)
    Affected: R9 , ≤ R11.0.2 (custom)
        cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_he_firmware Affected: 0 , ≤ R9.3.1 (custom)
        cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_e_firmware Affected: E95 , < 206 (custom)
    Affected: E90 , < 206 (custom)
    Affected: E80 , < 206 (custom)
    Affected: E9 113.2 , ≤ 113.2 (custom)
        cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_s_firmware Affected: 70N , < 206 (custom)
    Affected: 60N , < 206 (custom)
        cpe:2.3:o:gehealthcare:vivid_s_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_t_firmware Affected: T8 , < 206 (custom)
    Affected: T9 , < 206 (custom)
        cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_iq_firmware Affected: 0 , < 206 (custom)
        cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare invenia_abus_firmware Affected: 1.2.3
        cpe:2.3:o:gehealthcare:invenia_abus_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare invenia_abus_2.0_firmware Affected: 0 , < 2.2.9 (custom)
        cpe:2.3:o:gehealthcare:invenia_abus_2.0_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:40:21.121Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://securityupdate.gehealthcare.com/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "venue_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "R1"
                  },
                  {
                    "status": "affected",
                    "version": "R2"
                  },
                  {
                    "lessThanOrEqual": "R3.3",
                    "status": "affected",
                    "version": "R3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R4.2",
                    "status": "affected",
                    "version": "R4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "venue_go_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "R2"
                  },
                  {
                    "lessThanOrEqual": "R3.3",
                    "status": "affected",
                    "version": "R3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R4.2",
                    "status": "affected",
                    "version": "R4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "venue_fit_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThanOrEqual": "R3.3",
                    "status": "affected",
                    "version": "R3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R4.2",
                    "status": "affected",
                    "version": "R4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "logiq_e_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThanOrEqual": "R9.1.4",
                    "status": "affected",
                    "version": "R7",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R10.1.3",
                    "status": "affected",
                    "version": "R8",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R11.0.2",
                    "status": "affected",
                    "version": "R9",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "logiq_he_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThanOrEqual": "R9.3.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "vivid_e_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "E95",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "E90",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "E80",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "113.2",
                    "status": "affected",
                    "version": "E9 113.2",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_s_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "vivid_s_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "70N",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "60N",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "vivid_t_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "T8",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "T9",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "vivid_iq_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:invenia_abus_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "invenia_abus_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.2.3"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:invenia_abus_2.0_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "invenia_abus_2.0_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "2.2.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1486",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-12T14:08:59.014421Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-16T18:15:02.675Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Venue",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "R1"
                },
                {
                  "status": "affected",
                  "version": "R2"
                },
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.2",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Venue Go",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "R2"
                },
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.2",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Venue Fit",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.2",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ e",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R9.1.4",
                  "status": "affected",
                  "version": "R7",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R10.1.3",
                  "status": "affected",
                  "version": "R8",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R11.0.2",
                  "status": "affected",
                  "version": "R9",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ He",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R9.3.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid E",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E95",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E90",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E80",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "113.2",
                  "status": "affected",
                  "version": "E9 113.2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid S",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "70N",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "60N",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid T",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "T8",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "T9",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid iq",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Invenia ABUS",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.3"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Invenia ABUS 2.0",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "2.2.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices"
                }
              ],
              "value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-1",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-14T15:10:22.262Z",
            "orgId": "171caf72-b841-4e04-a68e-93493aff2b94",
            "shortName": "GEHC"
          },
          "references": [
            {
              "url": "https://securityupdate.gehealthcare.com/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94",
        "assignerShortName": "GEHC",
        "cveId": "CVE-2024-1486",
        "datePublished": "2024-05-14T15:10:22.262Z",
        "dateReserved": "2024-02-13T22:34:57.386Z",
        "dateUpdated": "2024-08-16T18:15:02.675Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-1630 (GCVE-0-2024-1630)

    Vulnerability from cvelistv5 – Published: 2024-05-14 16:55 – Updated: 2024-08-22 17:51
    VLAI
    Title
    Path traversal vulnerability in “getAllFolderContents” function of Common Service Desktop, a GE HealthCare ultrasound device component
    Summary
    Path traversal vulnerability in “getAllFolderContents” function of Common Service Desktop, a GE HealthCare ultrasound device component
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-14 19:43 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    GEHC CNA
    CNA scorecard – unranked: 0 records in the last 180 days, 10 needed details
    References
    Impacted products
    Vendor Product Version
    GE HealthCare Venue Affected: R1
    Affected: R2
    Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.3 (custom)
    Create a notification for this product.
    GE HealthCare Venue Go Affected: R2
    Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.3 (custom)
    Create a notification for this product.
    GE HealthCare Venue Fit Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.3 (custom)
    Create a notification for this product.
    GE HealthCare LOGIQ e Affected: R7 , ≤ R9.1.4 (custom)
    Affected: R8 , ≤ R10.1.3 (custom)
    Affected: R9 , ≤ R11.0.3 (custom)
    Create a notification for this product.
    GE HealthCare LOGIQ He Affected: 0 , ≤ R9.3.1 (custom)
    Create a notification for this product.
    GE HealthCare Vivid E Affected: E95 , < 206 (custom)
    Affected: E90 , < 206 (custom)
    Affected: E80 , < 206 (custom)
    Create a notification for this product.
    GE HealthCare Vivid T Affected: T8 , < 206 (custom)
    Affected: T9 , < 206 (custom)
    Create a notification for this product.
    GE HealthCare Vivid iq Affected: 0 , < 206 (custom)
    Create a notification for this product.
    GE HealthCare Voluson Expert 16 Affected: 0
    Affected: BT24
    Create a notification for this product.
    GE HealthCare Voluson Expert 18 Affected: 0
    Affected: BT24
    Create a notification for this product.
    GE HealthCare Voluson Expert 22 Affected: 0
    Affected: BT24
    Create a notification for this product.
    GE HealthCare Voluson SWIFT Affected: 0
    Affected: BT24
    Create a notification for this product.
    GE HealthCare LOGIQ E10 Affected: 0 , < R3.2.0 (custom)
    Create a notification for this product.
    GE HealthCare LOGIQ E10s Affected: 0 , < R3.2.0 (custom)
    Create a notification for this product.
    GE HealthCare LOGIQ Fortis Affected: 0 , < R3.2.0 (custom)
    Create a notification for this product.
    gehealthcare venue_firmware Affected: r1
    Affected: r2
    Affected: r3 , ≤ r3.3 (custom)
    Affected: r4 , ≤ r4.3 (custom)
        cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare venue_go_firmware Affected: r2
    Affected: r3 , ≤ r3.3 (custom)
    Affected: r4 , ≤ r4.3 (custom)
        cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare venue_fit_firmware Affected: r3 , ≤ r3.3 (custom)
    Affected: r4 , ≤ r4.3 (custom)
        cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_e_firmware Affected: r7 , ≤ r9.1.4 (custom)
    Affected: r8 , ≤ r10.1.3 (custom)
    Affected: r9 , ≤ r11.0.3 (custom)
        cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_he_firmware Affected: 0 , ≤ r9.3.1 (custom)
        cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_e_firmware Affected: e95 , < 206 (custom)
    Affected: e90 , < 206 (custom)
    Affected: e80 , < 206 (custom)
        cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_t_firmware Affected: t8 , < 206 (custom)
    Affected: t9 , < 206 (custom)
        cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_iq_firmware Affected: 0 , < 206 (custom)
        cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare voluson_expert_16 Affected: 0
    Affected: bt24
        cpe:2.3:a:gehealthcare:voluson_expert_16:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare voluson_expert_18 Affected: 0
    Affected: bt24
        cpe:2.3:a:gehealthcare:voluson_expert_18:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare voluson_expert_22 Affected: 0
    Affected: bt24
        cpe:2.3:a:gehealthcare:voluson_expert_22:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare voluson_swift Affected: 0
    Affected: bt24
        cpe:2.3:a:gehealthcare:voluson_swift:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_e10 Affected: 0 , < r3.2.0 (custom)
        cpe:2.3:a:gehealthcare:logiq_e10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_e10s Affected: 0 , < r3.2.0 (custom)
        cpe:2.3:a:gehealthcare:logiq_e10s:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_fortis Affected: 0 , < r3.2.0 (custom)
        cpe:2.3:a:gehealthcare:logiq_fortis:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:48:21.818Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://securityupdate.gehealthcare.com/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "venue_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "r1"
                  },
                  {
                    "status": "affected",
                    "version": "r2"
                  },
                  {
                    "lessThanOrEqual": "r3.3",
                    "status": "affected",
                    "version": "r3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "r4.3",
                    "status": "affected",
                    "version": "r4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "venue_go_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "r2"
                  },
                  {
                    "lessThanOrEqual": "r3.3",
                    "status": "affected",
                    "version": "r3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "r4.3",
                    "status": "affected",
                    "version": "r4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "venue_fit_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThanOrEqual": "r3.3",
                    "status": "affected",
                    "version": "r3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "r4.3",
                    "status": "affected",
                    "version": "r4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "logiq_e_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThanOrEqual": "r9.1.4",
                    "status": "affected",
                    "version": "r7",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "r10.1.3",
                    "status": "affected",
                    "version": "r8",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "r11.0.3",
                    "status": "affected",
                    "version": "r9",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "logiq_he_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThanOrEqual": "r9.3.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vivid_e_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "e95",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "e90",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "e80",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vivid_t_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "t8",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "t9",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vivid_iq_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:voluson_expert_16:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "voluson_expert_16",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  },
                  {
                    "status": "affected",
                    "version": "bt24"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:voluson_expert_18:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "voluson_expert_18",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  },
                  {
                    "status": "affected",
                    "version": "bt24"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:voluson_expert_22:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "voluson_expert_22",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  },
                  {
                    "status": "affected",
                    "version": "bt24"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:voluson_swift:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "voluson_swift",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  },
                  {
                    "status": "affected",
                    "version": "bt24"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:logiq_e10:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "logiq_e10",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "r3.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:logiq_e10s:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "logiq_e10s",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "r3.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:gehealthcare:logiq_fortis:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "logiq_fortis",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "r3.2.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1630",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-14T19:43:01.721848Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-22T17:51:14.776Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Venue",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "R1"
                },
                {
                  "status": "affected",
                  "version": "R2"
                },
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.3",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Venue Go",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "R2"
                },
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.3",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Venue Fit",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.3",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ e",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R9.1.4",
                  "status": "affected",
                  "version": "R7",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R10.1.3",
                  "status": "affected",
                  "version": "R8",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R11.0.3",
                  "status": "affected",
                  "version": "R9",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ He",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R9.3.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid E",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E95",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E90",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E80",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid T",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "T8",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "T9",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid iq",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Voluson Expert 16",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                },
                {
                  "status": "affected",
                  "version": "BT24"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Voluson Expert 18",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                },
                {
                  "status": "affected",
                  "version": "BT24"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Voluson Expert 22",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                },
                {
                  "status": "affected",
                  "version": "BT24"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Voluson SWIFT",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "0"
                },
                {
                  "status": "affected",
                  "version": "BT24"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ E10",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "R3.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ E10s",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "R3.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ Fortis",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "R3.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component"
                }
              ],
              "value": "Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-126",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-126 Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-14T16:55:56.853Z",
            "orgId": "171caf72-b841-4e04-a68e-93493aff2b94",
            "shortName": "GEHC"
          },
          "references": [
            {
              "url": "https://securityupdate.gehealthcare.com/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94",
        "assignerShortName": "GEHC",
        "cveId": "CVE-2024-1630",
        "datePublished": "2024-05-14T16:55:56.853Z",
        "dateReserved": "2024-02-19T15:28:03.794Z",
        "dateUpdated": "2024-08-22T17:51:14.776Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-1486 (GCVE-0-2024-1486)

    Vulnerability from cvelistv5 – Published: 2024-05-14 15:10 – Updated: 2024-08-16 18:15
    VLAI
    Title
    Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices
    Summary
    Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-12 14:08 UTC
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    GEHC CNA
    CNA scorecard – unranked: 0 records in the last 180 days, 10 needed details
    References
    Impacted products
    Vendor Product Version
    GE HealthCare Venue Affected: R1
    Affected: R2
    Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.2 (custom)
    Create a notification for this product.
    GE HealthCare Venue Go Affected: R2
    Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.2 (custom)
    Create a notification for this product.
    GE HealthCare Venue Fit Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.2 (custom)
    Create a notification for this product.
    GE HealthCare LOGIQ e Affected: R7 , ≤ R9.1.4 (custom)
    Affected: R8 , ≤ R10.1.3 (custom)
    Affected: R9 , ≤ R11.0.2 (custom)
    Create a notification for this product.
    GE HealthCare LOGIQ He Affected: 0 , ≤ R9.3.1 (custom)
    Create a notification for this product.
    GE HealthCare Vivid E Affected: E95 , < 206 (custom)
    Affected: E90 , < 206 (custom)
    Affected: E80 , < 206 (custom)
    Affected: E9 113.2 , ≤ 113.2 (custom)
    Create a notification for this product.
    GE HealthCare Vivid S Affected: 70N , < 206 (custom)
    Affected: 60N , < 206 (custom)
    Create a notification for this product.
    GE HealthCare Vivid T Affected: T8 , < 206 (custom)
    Affected: T9 , < 206 (custom)
    Create a notification for this product.
    GE HealthCare Vivid iq Affected: 0 , < 206 (custom)
    Create a notification for this product.
    GE HealthCare Invenia ABUS Affected: 1.2.3
    Create a notification for this product.
    GE HealthCare Invenia ABUS 2.0 Affected: 0 , < 2.2.9 (custom)
    Create a notification for this product.
    gehealthcare venue_firmware Affected: R1
    Affected: R2
    Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.2 (custom)
        cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare venue_go_firmware Affected: R2
    Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.2 (custom)
        cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare venue_fit_firmware Affected: R3 , ≤ R3.3 (custom)
    Affected: R4 , ≤ R4.2 (custom)
        cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_e_firmware Affected: R7 , ≤ R9.1.4 (custom)
    Affected: R8 , ≤ R10.1.3 (custom)
    Affected: R9 , ≤ R11.0.2 (custom)
        cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare logiq_he_firmware Affected: 0 , ≤ R9.3.1 (custom)
        cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_e_firmware Affected: E95 , < 206 (custom)
    Affected: E90 , < 206 (custom)
    Affected: E80 , < 206 (custom)
    Affected: E9 113.2 , ≤ 113.2 (custom)
        cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_s_firmware Affected: 70N , < 206 (custom)
    Affected: 60N , < 206 (custom)
        cpe:2.3:o:gehealthcare:vivid_s_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_t_firmware Affected: T8 , < 206 (custom)
    Affected: T9 , < 206 (custom)
        cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare vivid_iq_firmware Affected: 0 , < 206 (custom)
        cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare invenia_abus_firmware Affected: 1.2.3
        cpe:2.3:o:gehealthcare:invenia_abus_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    gehealthcare invenia_abus_2.0_firmware Affected: 0 , < 2.2.9 (custom)
        cpe:2.3:o:gehealthcare:invenia_abus_2.0_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:40:21.121Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://securityupdate.gehealthcare.com/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "venue_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "R1"
                  },
                  {
                    "status": "affected",
                    "version": "R2"
                  },
                  {
                    "lessThanOrEqual": "R3.3",
                    "status": "affected",
                    "version": "R3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R4.2",
                    "status": "affected",
                    "version": "R4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "venue_go_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "R2"
                  },
                  {
                    "lessThanOrEqual": "R3.3",
                    "status": "affected",
                    "version": "R3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R4.2",
                    "status": "affected",
                    "version": "R4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "venue_fit_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThanOrEqual": "R3.3",
                    "status": "affected",
                    "version": "R3",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R4.2",
                    "status": "affected",
                    "version": "R4",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "logiq_e_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThanOrEqual": "R9.1.4",
                    "status": "affected",
                    "version": "R7",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R10.1.3",
                    "status": "affected",
                    "version": "R8",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "R11.0.2",
                    "status": "affected",
                    "version": "R9",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "logiq_he_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThanOrEqual": "R9.3.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "vivid_e_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "E95",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "E90",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "E80",
                    "versionType": "custom"
                  },
                  {
                    "lessThanOrEqual": "113.2",
                    "status": "affected",
                    "version": "E9 113.2",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_s_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "vivid_s_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "70N",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "60N",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "vivid_t_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "T8",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "T9",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "vivid_iq_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "206",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:invenia_abus_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "invenia_abus_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.2.3"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:gehealthcare:invenia_abus_2.0_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "invenia_abus_2.0_firmware",
                "vendor": "gehealthcare",
                "versions": [
                  {
                    "lessThan": "2.2.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1486",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-12T14:08:59.014421Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-16T18:15:02.675Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Venue",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "R1"
                },
                {
                  "status": "affected",
                  "version": "R2"
                },
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.2",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Venue Go",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "R2"
                },
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.2",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Venue Fit",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R3.3",
                  "status": "affected",
                  "version": "R3",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R4.2",
                  "status": "affected",
                  "version": "R4",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ e",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R9.1.4",
                  "status": "affected",
                  "version": "R7",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R10.1.3",
                  "status": "affected",
                  "version": "R8",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "R11.0.2",
                  "status": "affected",
                  "version": "R9",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "LOGIQ He",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThanOrEqual": "R9.3.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid E",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E95",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E90",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "E80",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "113.2",
                  "status": "affected",
                  "version": "E9 113.2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid S",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "70N",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "60N",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid T",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "T8",
                  "versionType": "custom"
                },
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "T9",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Vivid iq",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "206",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Invenia ABUS",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.2.3"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Invenia ABUS 2.0",
              "vendor": "GE HealthCare",
              "versions": [
                {
                  "lessThan": "2.2.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices"
                }
              ],
              "value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-1",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-14T15:10:22.262Z",
            "orgId": "171caf72-b841-4e04-a68e-93493aff2b94",
            "shortName": "GEHC"
          },
          "references": [
            {
              "url": "https://securityupdate.gehealthcare.com/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94",
        "assignerShortName": "GEHC",
        "cveId": "CVE-2024-1486",
        "datePublished": "2024-05-14T15:10:22.262Z",
        "dateReserved": "2024-02-13T22:34:57.386Z",
        "dateUpdated": "2024-08-16T18:15:02.675Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }