    68 vulnerabilities found for laquis_scada by lcds

    FKIE_CVE-2021-32989

    Vulnerability from fkie_nvd - Published: 2022-05-25 14:15 - Updated: 2026-06-17 03:53
    Summary
    When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LAquis SCADA",
              "vendor": "LCDS\u2014Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME",
              "versions": [
                {
                  "lessThanOrEqual": "4.3.1.1011",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A067C375-E5C3-4E66-8F91-89E9F60DC326",
                  "versionEndIncluding": "4.3.1.1011",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting."
        },
        {
          "lang": "es",
          "value": "Cuando es solicitado un recurso no existente, la aplicaci\u00f3n LCDS LAquis SCADA (versiones 4.3.1.1011 y anteriores) devuelve mensajes de error que pueden permitir un ataque de tipo cross-site scripting reflejado"
        }
      ],
      "id": "CVE-2021-32989",
      "lastModified": "2026-06-17T03:53:57.760",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 9.3,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "LOW",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 4.7,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 2.7,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-32989",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-04-16T15:55:36.940023Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-05-25T14:15:08.450",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-208-04"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-208-04"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-79"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2020-10622

    Vulnerability from fkie_nvd - Published: 2020-05-04 19:15 - Updated: 2026-06-17 02:48
    Summary
    LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users
    References
    ics-cert@hq.dhs.govhttps://www.us-cert.gov/ics/advisories/icsa-20-119-01Mitigation, Third Party Advisory, US Government Resource
    af854a3a-2127-422b-91ae-364da2661108https://www.us-cert.gov/ics/advisories/icsa-20-119-01Mitigation, Third Party Advisory, US Government Resource
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS LAquis SCADA Versions 4.3.1 and prior",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "LCDS LAquis SCADA Versions 4.3.1 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "166A6CAB-0A15-4D8D-96F9-BD3E95A49075",
                  "versionEndIncluding": "4.3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users"
        },
        {
          "lang": "es",
          "value": "LCDS LAquis SCADA versiones 4.3.1 y anteriores. El producto afectado es vulnerable a una creaci\u00f3n de archivos arbitrarios por parte de usuarios no autorizados."
        }
      ],
      "id": "CVE-2020-10622",
      "lastModified": "2026-06-17T02:48:06.983",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-05-04T19:15:12.767",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Mitigation",
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mitigation",
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2020-10618

    Vulnerability from fkie_nvd - Published: 2020-05-04 19:15 - Updated: 2026-06-17 02:48
    Summary
    LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users.
    References
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS LAquis SCADA Versions 4.3.1 and prior",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "LCDS LAquis SCADA Versions 4.3.1 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "166A6CAB-0A15-4D8D-96F9-BD3E95A49075",
                  "versionEndIncluding": "4.3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users."
        },
        {
          "lang": "es",
          "value": "LCDS LAquis SCADA versiones 4.3.1 y anteriores. El producto afectado es vulnerable a una exposici\u00f3n de informaci\u00f3n confidencial por parte de usuarios no autorizados."
        }
      ],
      "id": "CVE-2020-10618",
      "lastModified": "2026-06-17T02:48:06.560",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-05-04T19:15:12.707",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-200"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-200"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2019-6536

    Vulnerability from fkie_nvd - Published: 2019-03-27 16:29 - Updated: 2026-06-17 02:39
    Summary
    Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process.
    Impacted products
    Vendor Product Version
    lcds laquis_scada 4.1.0.4150

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LAquis SCADA",
              "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003c 4.3.1.71"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:4.1.0.4150:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BA12D873-EB6A-4D64-BD12-8370ED063DDB",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process."
        },
        {
          "lang": "es",
          "value": "Abrir un archivo ELS especialmente manipulado de LCDS LAquis SCADA, en versiones anteriores a la 4.3.1.71, podr\u00eda resultar en una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado, lo que podr\u00eda permitir que un atacante ejecute c\u00f3digo remoto en el contexto del proceso actual."
        }
      ],
      "id": "CVE-2019-6536",
      "lastModified": "2026-06-17T02:39:12.760",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-03-27T16:29:00.780",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-307/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-307/"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-5463

    Vulnerability from fkie_nvd - Published: 2018-04-09 21:29 - Updated: 2026-06-17 02:00
    Summary
    A structured exception handler overflow vulnerability in Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA 4.1.0.3391 and earlier may allow code execution.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS - Le\u0026#195;\u0026#163;o Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.1.0.3391 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5986FBB6-AF75-45BE-8132-D5981B12B7B3",
                  "versionEndIncluding": "4.1.0.3391",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A structured exception handler overflow vulnerability in Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA 4.1.0.3391 and earlier may allow code execution."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad de desbordamiento del controlador de excepci\u00f3n estructurada en Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA, en versiones 4.1.0.3391 y anteriores, podr\u00edan permitir la ejecuci\u00f3n de c\u00f3digo."
        }
      ],
      "id": "CVE-2018-5463",
      "lastModified": "2026-06-17T02:00:21.583",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.6,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-04-09T21:29:00.210",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/103724"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-095-03"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/103724"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-095-03"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-703"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-19029

    Vulnerability from fkie_nvd - Published: 2019-02-05 18:29 - Updated: 2026-06-17 01:48
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "LCDS",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A410DB6E-D5ED-411B-85EF-8445506E147A",
                  "versionEndExcluding": "4.1.0.4150",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash."
        },
        {
          "lang": "es",
          "value": "LCDS Laquis SCADA, en versiones anteriores a la 4.1.0.4150, permite a un atacante utilizar un archivo de proyecto especialmente manipulado para proporcionar un puntero para una direcci\u00f3n de memoria controlada, lo que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo, la exfiltraci\u00f3n de datos o el cierre inesperado del sistema."
        }
      ],
      "id": "CVE-2018-19029",
      "lastModified": "2026-06-17T01:48:39.840",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 8.3,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 8.5,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-02-05T18:29:00.820",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-822"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-476"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-19004

    Vulnerability from fkie_nvd - Published: 2019-02-01 18:29 - Updated: 2026-06-17 01:48
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows out of bounds read when opening a specially crafted project file, which may allow data exfiltration.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A410DB6E-D5ED-411B-85EF-8445506E147A",
                  "versionEndExcluding": "4.1.0.4150",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows out of bounds read when opening a specially crafted project file, which may allow data exfiltration."
        },
        {
          "lang": "es",
          "value": "LCDS Laquis SCADA, en versiones anteriores a la 4.1.0.4150, permite una lectura fuera de l\u00edmites a la hora de abrir un archivo de proyecto especialmente manipulado, lo que podr\u00eda permitir la exfiltraci\u00f3n de datos."
        }
      ],
      "id": "CVE-2018-19004",
      "lastModified": "2026-06-17T01:48:37.347",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 3.3,
              "baseSeverity": "LOW",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-02-01T18:29:01.193",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-19002

    Vulnerability from fkie_nvd - Published: 2019-02-05 18:29 - Updated: 2026-06-17 01:48
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "LCDS",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A410DB6E-D5ED-411B-85EF-8445506E147A",
                  "versionEndExcluding": "4.1.0.4150",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash."
        },
        {
          "lang": "es",
          "value": "LCDS Laquis SCADA, en versiones anteriores a la 4.1.0.4150, permite el control incorrecto de la generaci\u00f3n de c\u00f3digo a la hora de abrir un archivo de proyecto especialmente manipulado, lo que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo, la exfiltraci\u00f3n de datos o el cierre inesperado del sistema."
        }
      ],
      "id": "CVE-2018-19002",
      "lastModified": "2026-06-17T01:48:37.093",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 8.3,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 8.5,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-02-05T18:29:00.773",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-94"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-94"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-19000

    Vulnerability from fkie_nvd - Published: 2019-02-05 18:29 - Updated: 2026-06-17 01:48
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows an authentication bypass, which may allow an attacker access to sensitive data.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A410DB6E-D5ED-411B-85EF-8445506E147A",
                  "versionEndExcluding": "4.1.0.4150",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows an authentication bypass, which may allow an attacker access to sensitive data."
        },
        {
          "lang": "es",
          "value": "LCDS Laquis SCADA, en versiones anteriores a la 4.1.0.4150, permite una omisi\u00f3n de autenticaci\u00f3n, lo que podr\u00eda permitir a un atacante acceder a datos sensibles."
        }
      ],
      "id": "CVE-2018-19000",
      "lastModified": "2026-06-17T01:48:36.837",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-02-05T18:29:00.743",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-288"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-287"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-18998

    Vulnerability from fkie_nvd - Published: 2019-02-05 18:29 - Updated: 2026-06-17 01:48
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A410DB6E-D5ED-411B-85EF-8445506E147A",
                  "versionEndExcluding": "4.1.0.4150",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges."
        },
        {
          "lang": "es",
          "value": "LCDS Laquis SCADA, en versiones anteriores a la 4.1.0.4150, utiliza credenciales embebidas, lo que podr\u00eda permitir a un atacante obtener acceso no autorizado al sistema con privilegios altos."
        }
      ],
      "id": "CVE-2018-18998",
      "lastModified": "2026-06-17T01:48:14.853",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-02-05T18:29:00.710",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-798"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-798"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-18996

    Vulnerability from fkie_nvd - Published: 2019-02-05 18:29 - Updated: 2026-06-17 01:48
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper authorization or sanitation, which may allow an attacker to execute remote code on the server.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A410DB6E-D5ED-411B-85EF-8445506E147A",
                  "versionEndExcluding": "4.1.0.4150",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper authorization or sanitation, which may allow an attacker to execute remote code on the server."
        },
        {
          "lang": "es",
          "value": "LCDS Laquis SCADA, en versiones anteriores a la 4.1.0.4150, permite la recepci\u00f3n de entradas del usuario sin que est\u00e9n saneadas o autorizadas correctamente, lo que podr\u00eda permitir a un atacante ejecutar c\u00f3digo remoto en el servidor."
        }
      ],
      "id": "CVE-2018-18996",
      "lastModified": "2026-06-17T01:48:14.620",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-02-05T18:29:00.663",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-74"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-862"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-18992

    Vulnerability from fkie_nvd - Published: 2019-02-05 18:29 - Updated: 2026-06-17 01:48
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the server.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A410DB6E-D5ED-411B-85EF-8445506E147A",
                  "versionEndExcluding": "4.1.0.4150",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the server."
        },
        {
          "lang": "es",
          "value": "LCDS Laquis SCADA, en versiones anteriores a la 4.1.0.4150, permite la recepci\u00f3n de entradas del usuario sin que est\u00e9n saneadas correctamente, lo que podr\u00eda permitir a un atacante ejecutar c\u00f3digo remoto en el servidor."
        }
      ],
      "id": "CVE-2018-18992",
      "lastModified": "2026-06-17T01:48:14.153",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-02-05T18:29:00.617",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-74"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-74"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-18990

    Vulnerability from fkie_nvd - Published: 2019-02-05 18:29 - Updated: 2026-06-17 01:48
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation. An attacker can leverage this vulnerability to disclose sensitive information under the context of the web server process.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A410DB6E-D5ED-411B-85EF-8445506E147A",
                  "versionEndExcluding": "4.1.0.4150",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation. An attacker can leverage this vulnerability to disclose sensitive information under the context of the web server process."
        },
        {
          "lang": "es",
          "value": "LCDS Laquis SCADA, en versiones anteriores a la 4.1.0.4150, permite una ruta proporcionada por el usuario en operaciones de archivo antes de validarse correctamente. Un atacante podr\u00eda aprovecharse de esta vulnerabilidad para divulgar informaci\u00f3n sensible en el contexto del proceso del servidor web."
        }
      ],
      "id": "CVE-2018-18990",
      "lastModified": "2026-06-17T01:48:13.930",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-02-05T18:29:00.587",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-23"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-18988

    Vulnerability from fkie_nvd - Published: 2019-02-01 17:29 - Updated: 2026-06-17 01:48
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows execution of script code by opening a specially crafted report format file. This may allow remote code execution, data exfiltration, or cause a system crash.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "ICS-CERT",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A410DB6E-D5ED-411B-85EF-8445506E147A",
                  "versionEndExcluding": "4.1.0.4150",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows execution of script code by opening a specially crafted report format file. This may allow remote code execution, data exfiltration, or cause a system crash."
        },
        {
          "lang": "es",
          "value": "LCDS Laquis SCADA, en versiones anteriores a la 4.1.0.4150, permite la ejecuci\u00f3n de c\u00f3digo script abriendo un archivo de formato de informe especialmente manipulado. Esto podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo, la exfiltraci\u00f3n de datos o provocar el cierre inesperado del sistema."
        }
      ],
      "id": "CVE-2018-18988",
      "lastModified": "2026-06-17T01:48:13.697",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 8.3,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 8.5,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-02-01T17:29:00.187",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-18986

    Vulnerability from fkie_nvd - Published: 2019-02-05 18:29 - Updated: 2026-06-17 01:48
    Summary
    LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LCDS Laquis SCADA",
              "vendor": "LCDS",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions prior to version 4.1.0.4150"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A410DB6E-D5ED-411B-85EF-8445506E147A",
                  "versionEndExcluding": "4.1.0.4150",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution."
        },
        {
          "lang": "es",
          "value": "LCDS Laquis SCADA, en versiones anteriores a la 4.1.0.4150, permite la apertura de un archivo de formato de informe especialmente manipulado que podr\u00eda causar el cierre inesperado del sistema, permitir la exfiltraci\u00f3n de datos o la ejecuci\u00f3n remota de c\u00f3digo."
        }
      ],
      "id": "CVE-2018-18986",
      "lastModified": "2026-06-17T01:48:13.477",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 8.3,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 8.5,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-02-05T18:29:00.553",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-17911

    Vulnerability from fkie_nvd - Published: 2018-10-17 02:29 - Updated: 2026-06-17 01:46
    Summary
    LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LAquis SCADA",
              "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.1.0.3870 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B5F605D9-73FC-4D5B-9884-50512081BF6F",
                  "versionEndIncluding": "4.1.0.3870",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution."
        },
        {
          "lang": "es",
          "value": "LAquis SCADA en versiones 4.1.0.3870 y anteriores tiene varias vulnerabilidades de desbordamiento de b\u00fafer basado en pila que podr\u00edan permitir la ejecuci\u00f3n remota de c\u00f3digo."
        }
      ],
      "id": "CVE-2018-17911",
      "lastModified": "2026-06-17T01:46:30.967",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-10-17T02:29:01.280",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Product",
            "Vendor Advisory"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        },
        {
          "source": "nvd@nist.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-18-1258/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product",
            "Vendor Advisory"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-17901

    Vulnerability from fkie_nvd - Published: 2018-10-17 02:29 - Updated: 2026-06-17 01:46
    Summary
    LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LAquis SCADA",
              "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.1.0.3870 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B5F605D9-73FC-4D5B-9884-50512081BF6F",
                  "versionEndIncluding": "4.1.0.3870",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process."
        },
        {
          "lang": "es",
          "value": "LAquis SCADA en versiones 4.1.0.3870 y anteriores, al procesar archivos de proyecto, no sanea las entradas del usuario antes de realizar operaciones de escritura en un objeto de la pila, lo que podr\u00eda permitir que el atacante ejecute c\u00f3digo en el proceso actual."
        }
      ],
      "id": "CVE-2018-17901",
      "lastModified": "2026-06-17T01:46:29.780",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-10-17T02:29:01.140",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Product",
            "Vendor Advisory"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        },
        {
          "source": "nvd@nist.gov",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/151421"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product",
            "Vendor Advisory"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-17899

    Vulnerability from fkie_nvd - Published: 2018-10-17 02:29 - Updated: 2026-06-17 01:46
    Summary
    LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LAquis SCADA",
              "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.1.0.3870 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B5F605D9-73FC-4D5B-9884-50512081BF6F",
                  "versionEndIncluding": "4.1.0.3870",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LAquis SCADA Versions 4.1.0.3870 and prior has a path traversal vulnerability, which may allow remote code execution."
        },
        {
          "lang": "es",
          "value": "LAquis SCADA en versiones 4.1.0.3870 y anteriores tiene una vulnerabilidad de salto de directorio que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo."
        }
      ],
      "id": "CVE-2018-17899",
      "lastModified": "2026-06-17T01:46:29.533",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-10-17T02:29:01.000",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Product",
            "Vendor Advisory"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/105719"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        },
        {
          "source": "nvd@nist.gov",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/151420"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product",
            "Vendor Advisory"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/105719"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-17897

    Vulnerability from fkie_nvd - Published: 2018-10-17 02:29 - Updated: 2026-06-17 01:46
    Summary
    LAquis SCADA Versions 4.1.0.3870 and prior has several integer overflow to buffer overflow vulnerabilities, which may allow remote code execution.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B5F605D9-73FC-4D5B-9884-50512081BF6F",
                  "versionEndIncluding": "4.1.0.3870",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LAquis SCADA Versions 4.1.0.3870 and prior has several integer overflow to buffer overflow vulnerabilities, which may allow remote code execution."
        },
        {
          "lang": "es",
          "value": "LAquis SCADA en versiones 4.1.0.3870 y anteriores tiene varias vulnerabilidades de desbordamiento de enteros y desbordamiento de b\u00fafer que podr\u00edan permitir la ejecuci\u00f3n remota de c\u00f3digo."
        }
      ],
      "id": "CVE-2018-17897",
      "lastModified": "2026-06-17T01:46:29.290",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-10-17T02:29:00.857",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Product",
            "Vendor Advisory"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/105719"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product",
            "Vendor Advisory"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/105719"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-190"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-17895

    Vulnerability from fkie_nvd - Published: 2018-10-17 02:29 - Updated: 2026-06-17 01:46
    Summary
    LAquis SCADA Versions 4.1.0.3870 and prior has several out-of-bounds read vulnerabilities, which may allow remote code execution.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LAquis SCADA",
              "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.1.0.3870 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B5F605D9-73FC-4D5B-9884-50512081BF6F",
                  "versionEndIncluding": "4.1.0.3870",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LAquis SCADA Versions 4.1.0.3870 and prior has several out-of-bounds read vulnerabilities, which may allow remote code execution."
        },
        {
          "lang": "es",
          "value": "LAquis SCADA en versiones 4.1.0.3870 y anteriores tiene varias vulnerabilidades de lectura fuera de l\u00edmites que podr\u00edan permitir la ejecuci\u00f3n remota de c\u00f3digo."
        }
      ],
      "id": "CVE-2018-17895",
      "lastModified": "2026-06-17T01:46:29.057",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-10-17T02:29:00.733",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Product",
            "Vendor Advisory"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/105719"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product",
            "Vendor Advisory"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/105719"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-17893

    Vulnerability from fkie_nvd - Published: 2018-10-17 02:29 - Updated: 2026-06-17 01:46
    Summary
    LAquis SCADA Versions 4.1.0.3870 and prior has an untrusted pointer dereference vulnerability, which may allow remote code execution.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LAquis SCADA",
              "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas LTDA ME",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.1.0.3870 and prior"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B5F605D9-73FC-4D5B-9884-50512081BF6F",
                  "versionEndIncluding": "4.1.0.3870",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "LAquis SCADA Versions 4.1.0.3870 and prior has an untrusted pointer dereference vulnerability, which may allow remote code execution."
        },
        {
          "lang": "es",
          "value": "LAquis SCADA en versiones 4.1.0.3870 y anteriores tiene una vulnerabilidad de desreferencia de puntero no fiable que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo."
        }
      ],
      "id": "CVE-2018-17893",
      "lastModified": "2026-06-17T01:46:28.820",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-10-17T02:29:00.593",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Product",
            "Vendor Advisory"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/105719"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        },
        {
          "source": "nvd@nist.gov",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/151417"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Product",
            "Vendor Advisory"
          ],
          "url": "http://laquisscada.com/instale1.php"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/105719"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-289-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-822"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-476"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2017-6020

    Vulnerability from fkie_nvd - Published: 2018-04-17 14:29 - Updated: 2026-06-17 01:21
    Summary
    Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA software versions prior to version 4.1.0.3237 do not neutralize external input to ensure that users are not calling for absolute path sequences outside of their privilege level.
    Impacted products
    Vendor Product Version
    lcds laquis_scada *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "LAquis SCADA software",
              "vendor": "LCDS - Le\u00c3\u00a3o Consultoria e Desenvolvimento de Sistemas LTDA ME",
              "versions": [
                {
                  "status": "affected",
                  "version": "versions prior to version 4.1.0.3237"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "16D7E67B-A131-425C-A3B5-1E8FD4C0EDFD",
                  "versionEndExcluding": "4.1.0.3237",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA software versions prior to version 4.1.0.3237 do not neutralize external input to ensure that users are not calling for absolute path sequences outside of their privilege level."
        },
        {
          "lang": "es",
          "value": "El software de Leao Consultoria e Desenvolvimento de Sistemas (LCDS), LTDA ME LAquis SCADA, en versiones anteriores a la 4.1.0.3237, no neutraliza las entradas externas para asegurarse de que los usuarios no est\u00e1n llamando a secuencias de ruta absolutas fuera de su nivel de privilegios."
        }
      ],
      "id": "CVE-2017-6020",
      "lastModified": "2026-06-17T01:21:38.387",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-04-17T14:29:00.290",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/97055"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-082-01"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://www.exploit-db.com/exploits/42885/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/97055"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-082-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://www.exploit-db.com/exploits/42885/"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2024-5040 (GCVE-0-2024-5040)

    Vulnerability from nvd – Published: 2024-05-21 20:19 – Updated: 2024-08-01 21:03
    VLAI
    Title
    LCDS LAquis SCADA Path Traversal
    Summary
    There are multiple ways in LCDS LAquis SCADA for an attacker to access locations outside of their own directory.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-22 14:29 UTC
    CWE
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 336 records in the last 180 days details
    Impacted products
    Vendor Product Version
    LCDS LAquis SCADA Affected: 0 , ≤ 4.7.1.7 (custom)
    Create a notification for this product.
    lcds laquis_scada Affected: *
        cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "laquis_scada",
                "vendor": "lcds",
                "versions": [
                  {
                    "status": "affected",
                    "version": "*"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-5040",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-22T14:29:23.705386Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T18:02:51.586Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T21:03:10.607Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-142-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "LAquis SCADA",
              "vendor": "LCDS",
              "versions": [
                {
                  "lessThanOrEqual": "4.7.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\nThere are multiple ways in \nLCDS LAquis SCADA for an attacker to access locations outside of their own directory.\n\n"
                }
              ],
              "value": "There are multiple ways in \nLCDS LAquis SCADA for an attacker to access locations outside of their own directory."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Path Traversal",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-21T20:19:19.456Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-142-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\nLCDS recommends users update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://laquisscada.com/\"\u003eversion 4.7.1.371 or newer of LAquis SCADA.\u003c/a\u003e which has been configured to resolve the reported path traversal issues.\n\n\u003cbr\u003e"
                }
              ],
              "value": "LCDS recommends users update to  version 4.7.1.371 or newer of LAquis SCADA. https://laquisscada.com/  which has been configured to resolve the reported path traversal issues."
            }
          ],
          "source": {
            "advisory": "ICSA-24-142-01",
            "discovery": "EXTERNAL"
          },
          "title": "LCDS LAquis SCADA Path Traversal",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-5040",
        "datePublished": "2024-05-21T20:19:19.456Z",
        "dateReserved": "2024-05-16T23:41:33.314Z",
        "dateUpdated": "2024-08-01T21:03:10.607Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-32989 (GCVE-0-2021-32989)

    Vulnerability from nvd – Published: 2022-05-25 13:31 – Updated: 2025-04-16 16:18
    VLAI
    Title
    LCDS LAquis SCADA - Cross-site Scripting
    Summary
    When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 15:55 UTC
    CWE
    • CWE-79 - Cross-site Scripting (XSS)
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 336 records in the last 180 days details
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:42:19.107Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-208-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-32989",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:55:36.940023Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:18:23.554Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LAquis SCADA",
              "vendor": "LCDS\u2014Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME",
              "versions": [
                {
                  "lessThanOrEqual": "4.3.1.1011",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Cross-site Scripting (XSS)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-25T13:31:36.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-208-04"
            }
          ],
          "source": {
            "advisory": "ICSA-21-208-04",
            "discovery": "UNKNOWN"
          },
          "title": "LCDS LAquis SCADA - Cross-site Scripting",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-32989",
              "STATE": "PUBLIC",
              "TITLE": "LCDS LAquis SCADA - Cross-site Scripting"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LAquis SCADA",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "All",
                                "version_value": "4.3.1.1011"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "LCDS\u2014Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported this vulnerability to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79 Cross-site Scripting (XSS)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-208-04",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-208-04"
                }
              ]
            },
            "source": {
              "advisory": "ICSA-21-208-04",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-32989",
        "datePublished": "2022-05-25T13:31:36.000Z",
        "dateReserved": "2021-05-13T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:18:23.554Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-10622 (GCVE-0-2020-10622)

    Vulnerability from nvd – Published: 2020-05-04 18:26 – Updated: 2024-08-04 11:06
    VLAI
    Summary
    LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users
    Severity
    No CVSS data available.
    CWE
    • CWE-20 - IMPROPER INPUT VALIDATION CWE-20
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 336 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a LCDS LAquis SCADA Versions 4.3.1 and prior Affected: LCDS LAquis SCADA Versions 4.3.1 and prior
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:06:10.160Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LCDS LAquis SCADA Versions 4.3.1 and prior",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "LCDS LAquis SCADA Versions 4.3.1 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "IMPROPER INPUT VALIDATION CWE-20",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-05-04T18:26:04.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-10622",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LCDS LAquis SCADA Versions 4.3.1 and prior",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "LCDS LAquis SCADA Versions 4.3.1 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "IMPROPER INPUT VALIDATION CWE-20"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-10622",
        "datePublished": "2020-05-04T18:26:04.000Z",
        "dateReserved": "2020-03-16T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:06:10.160Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-10618 (GCVE-0-2020-10618)

    Vulnerability from nvd – Published: 2020-05-04 18:24 – Updated: 2024-08-04 11:06
    VLAI
    Summary
    LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users.
    Severity
    No CVSS data available.
    CWE
    • CWE-200 - EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 336 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a LCDS LAquis SCADA Versions 4.3.1 and prior Affected: LCDS LAquis SCADA Versions 4.3.1 and prior
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:06:10.194Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LCDS LAquis SCADA Versions 4.3.1 and prior",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "LCDS LAquis SCADA Versions 4.3.1 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-05-04T18:24:38.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-10618",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LCDS LAquis SCADA Versions 4.3.1 and prior",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "LCDS LAquis SCADA Versions 4.3.1 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-10618",
        "datePublished": "2020-05-04T18:24:38.000Z",
        "dateReserved": "2020-03-16T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:06:10.194Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-5040 (GCVE-0-2024-5040)

    Vulnerability from cvelistv5 – Published: 2024-05-21 20:19 – Updated: 2024-08-01 21:03
    VLAI
    Title
    LCDS LAquis SCADA Path Traversal
    Summary
    There are multiple ways in LCDS LAquis SCADA for an attacker to access locations outside of their own directory.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-05-22 14:29 UTC
    CWE
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 336 records in the last 180 days details
    Impacted products
    Vendor Product Version
    LCDS LAquis SCADA Affected: 0 , ≤ 4.7.1.7 (custom)
    Create a notification for this product.
    lcds laquis_scada Affected: *
        cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "laquis_scada",
                "vendor": "lcds",
                "versions": [
                  {
                    "status": "affected",
                    "version": "*"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-5040",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-22T14:29:23.705386Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T18:02:51.586Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T21:03:10.607Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-142-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "LAquis SCADA",
              "vendor": "LCDS",
              "versions": [
                {
                  "lessThanOrEqual": "4.7.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\nThere are multiple ways in \nLCDS LAquis SCADA for an attacker to access locations outside of their own directory.\n\n"
                }
              ],
              "value": "There are multiple ways in \nLCDS LAquis SCADA for an attacker to access locations outside of their own directory."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Path Traversal",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-21T20:19:19.456Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-142-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\nLCDS recommends users update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://laquisscada.com/\"\u003eversion 4.7.1.371 or newer of LAquis SCADA.\u003c/a\u003e which has been configured to resolve the reported path traversal issues.\n\n\u003cbr\u003e"
                }
              ],
              "value": "LCDS recommends users update to  version 4.7.1.371 or newer of LAquis SCADA. https://laquisscada.com/  which has been configured to resolve the reported path traversal issues."
            }
          ],
          "source": {
            "advisory": "ICSA-24-142-01",
            "discovery": "EXTERNAL"
          },
          "title": "LCDS LAquis SCADA Path Traversal",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-5040",
        "datePublished": "2024-05-21T20:19:19.456Z",
        "dateReserved": "2024-05-16T23:41:33.314Z",
        "dateUpdated": "2024-08-01T21:03:10.607Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-32989 (GCVE-0-2021-32989)

    Vulnerability from cvelistv5 – Published: 2022-05-25 13:31 – Updated: 2025-04-16 16:18
    VLAI
    Title
    LCDS LAquis SCADA - Cross-site Scripting
    Summary
    When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-04-16 15:55 UTC
    CWE
    • CWE-79 - Cross-site Scripting (XSS)
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 336 records in the last 180 days details
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:42:19.107Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-208-04"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-32989",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:55:36.940023Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T16:18:23.554Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LAquis SCADA",
              "vendor": "LCDS\u2014Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME",
              "versions": [
                {
                  "lessThanOrEqual": "4.3.1.1011",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Michael Heinzl reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Cross-site Scripting (XSS)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-05-25T13:31:36.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-208-04"
            }
          ],
          "source": {
            "advisory": "ICSA-21-208-04",
            "discovery": "UNKNOWN"
          },
          "title": "LCDS LAquis SCADA - Cross-site Scripting",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2021-32989",
              "STATE": "PUBLIC",
              "TITLE": "LCDS LAquis SCADA - Cross-site Scripting"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LAquis SCADA",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "All",
                                "version_value": "4.3.1.1011"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "LCDS\u2014Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Michael Heinzl reported this vulnerability to CISA."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "When a non-existent resource is requested, the LCDS LAquis SCADA application (version 4.3.1.1011 and prior) returns error messages which may allow reflected cross-site scripting."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "LOW",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79 Cross-site Scripting (XSS)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-208-04",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-208-04"
                }
              ]
            },
            "source": {
              "advisory": "ICSA-21-208-04",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2021-32989",
        "datePublished": "2022-05-25T13:31:36.000Z",
        "dateReserved": "2021-05-13T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:18:23.554Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-10622 (GCVE-0-2020-10622)

    Vulnerability from cvelistv5 – Published: 2020-05-04 18:26 – Updated: 2024-08-04 11:06
    VLAI
    Summary
    LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users
    Severity
    No CVSS data available.
    CWE
    • CWE-20 - IMPROPER INPUT VALIDATION CWE-20
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 336 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a LCDS LAquis SCADA Versions 4.3.1 and prior Affected: LCDS LAquis SCADA Versions 4.3.1 and prior
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:06:10.160Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LCDS LAquis SCADA Versions 4.3.1 and prior",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "LCDS LAquis SCADA Versions 4.3.1 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "IMPROPER INPUT VALIDATION CWE-20",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-05-04T18:26:04.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-10622",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LCDS LAquis SCADA Versions 4.3.1 and prior",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "LCDS LAquis SCADA Versions 4.3.1 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "IMPROPER INPUT VALIDATION CWE-20"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-10622",
        "datePublished": "2020-05-04T18:26:04.000Z",
        "dateReserved": "2020-03-16T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:06:10.160Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-10618 (GCVE-0-2020-10618)

    Vulnerability from cvelistv5 – Published: 2020-05-04 18:24 – Updated: 2024-08-04 11:06
    VLAI
    Summary
    LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users.
    Severity
    No CVSS data available.
    CWE
    • CWE-200 - EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 336 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    n/a LCDS LAquis SCADA Versions 4.3.1 and prior Affected: LCDS LAquis SCADA Versions 4.3.1 and prior
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:06:10.194Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LCDS LAquis SCADA Versions 4.3.1 and prior",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "LCDS LAquis SCADA Versions 4.3.1 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-05-04T18:24:38.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2020-10618",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LCDS LAquis SCADA Versions 4.3.1 and prior",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "LCDS LAquis SCADA Versions 4.3.1 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01",
                  "refsource": "MISC",
                  "url": "https://www.us-cert.gov/ics/advisories/icsa-20-119-01"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-10618",
        "datePublished": "2020-05-04T18:24:38.000Z",
        "dateReserved": "2020-03-16T00:00:00.000Z",
        "dateUpdated": "2024-08-04T11:06:10.194Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }