Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for inspiron_7460_firmware by dell

    CVE-2023-32471 (GCVE-0-2023-32471)

    Vulnerability from nvd – Published: 2024-07-24 07:08 – Updated: 2024-08-02 15:18
    VLAI
    Summary
    Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds read vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability to read contents of stack memory and use this information for further exploits.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Edge Gateway 5200 Affected: N/A , < v1.05.10 (semver)
    Create a notification for this product.
    Dell Dell Edge Gateway 3200 Affected: N/A , < v1.03.10 (semver)
    Create a notification for this product.
    dell dell_edge_gateway_5200 Affected: 0 , < v1.05.10 (semver)
        cpe:2.3:h:dell:dell_edge_gateway_5200:*:*:*:*:*:*:*:*
    Create a notification for this product.
    dell dell_edge_gateway_3200 Affected: 0 , < v1.03.10 (semver)
        cpe:2.3:h:dell:dell_edge_gateway_3200:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-06-14 06:30
    Credits
    Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:dell:dell_edge_gateway_5200:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "dell_edge_gateway_5200",
                "vendor": "dell",
                "versions": [
                  {
                    "lessThan": "v1.05.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:dell:dell_edge_gateway_3200:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "dell_edge_gateway_3200",
                "vendor": "dell",
                "versions": [
                  {
                    "lessThan": "v1.03.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32471",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-24T18:41:40.675410Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-24T19:02:33.270Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.608Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Edge Gateway 5200",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "v1.05.10",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Dell Edge Gateway 3200",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "v1.03.10",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues."
            }
          ],
          "datePublic": "2023-06-14T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds read vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability to read contents of stack memory and use this information for further exploits."
                }
              ],
              "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds read vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability to read contents of stack memory and use this information for further exploits."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-24T07:08:51.832Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32471",
        "datePublished": "2024-07-24T07:08:51.832Z",
        "dateReserved": "2023-05-09T06:07:41.364Z",
        "dateUpdated": "2024-08-02T15:18:37.608Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-3717 (GCVE-0-2019-3717)

    Vulnerability from nvd – Published: 2019-08-05 16:38 – Updated: 2024-09-16 16:43
    VLAI
    Summary
    Select Dell Client Commercial and Consumer platforms contain an Improper Access Vulnerability. An unauthenticated attacker with physical access to the system could potentially bypass intended Secure Boot restrictions to run unsigned and untrusted code on expansion cards installed in the system during platform boot. Refer to https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en for versions affected by this vulnerability.
    CWE
    • Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Client Commercial and Consumer platforms Affected: https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en
    Create a notification for this product.
    Date Public
    2019-07-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T19:19:17.451Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Dell Client Commercial and Consumer platforms",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en"
                }
              ]
            }
          ],
          "datePublic": "2019-07-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Select Dell Client Commercial and Consumer platforms contain an Improper Access Vulnerability. An unauthenticated attacker with physical access to the system could potentially bypass intended Secure Boot restrictions to run unsigned and untrusted code on expansion cards installed in the system during platform boot. Refer to https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en for versions affected by this vulnerability."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "HIGH",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:L/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Access Control",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-05T16:38:20.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.7"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2019-07-08T04:00:00.000Z",
              "ID": "CVE-2019-3717",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Dell Client Commercial and Consumer platforms",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Select Dell Client Commercial and Consumer platforms contain an Improper Access Vulnerability. An unauthenticated attacker with physical access to the system could potentially bypass intended Secure Boot restrictions to run unsigned and untrusted code on expansion cards installed in the system during platform boot. Refer to https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en for versions affected by this vulnerability."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.7"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:L/A:H",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en",
                  "refsource": "CONFIRM",
                  "url": "https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2019-3717",
        "datePublished": "2019-08-05T16:38:20.346Z",
        "dateReserved": "2019-01-03T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:43:43.212Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32471 (GCVE-0-2023-32471)

    Vulnerability from cvelistv5 – Published: 2024-07-24 07:08 – Updated: 2024-08-02 15:18
    VLAI
    Summary
    Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds read vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability to read contents of stack memory and use this information for further exploits.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Edge Gateway 5200 Affected: N/A , < v1.05.10 (semver)
    Create a notification for this product.
    Dell Dell Edge Gateway 3200 Affected: N/A , < v1.03.10 (semver)
    Create a notification for this product.
    dell dell_edge_gateway_5200 Affected: 0 , < v1.05.10 (semver)
        cpe:2.3:h:dell:dell_edge_gateway_5200:*:*:*:*:*:*:*:*
    Create a notification for this product.
    dell dell_edge_gateway_3200 Affected: 0 , < v1.03.10 (semver)
        cpe:2.3:h:dell:dell_edge_gateway_3200:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-06-14 06:30
    Credits
    Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:dell:dell_edge_gateway_5200:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "dell_edge_gateway_5200",
                "vendor": "dell",
                "versions": [
                  {
                    "lessThan": "v1.05.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:dell:dell_edge_gateway_3200:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "dell_edge_gateway_3200",
                "vendor": "dell",
                "versions": [
                  {
                    "lessThan": "v1.03.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-32471",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-24T18:41:40.675410Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-24T19:02:33.270Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.608Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dell Edge Gateway 5200",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "v1.05.10",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Dell Edge Gateway 3200",
              "vendor": "Dell",
              "versions": [
                {
                  "lessThan": "v1.03.10",
                  "status": "affected",
                  "version": "N/A",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues."
            }
          ],
          "datePublic": "2023-06-14T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds read vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability to read contents of stack memory and use this information for further exploits."
                }
              ],
              "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds read vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability to read contents of stack memory and use this information for further exploits."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-24T07:08:51.832Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32471",
        "datePublished": "2024-07-24T07:08:51.832Z",
        "dateReserved": "2023-05-09T06:07:41.364Z",
        "dateUpdated": "2024-08-02T15:18:37.608Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-3717 (GCVE-0-2019-3717)

    Vulnerability from cvelistv5 – Published: 2019-08-05 16:38 – Updated: 2024-09-16 16:43
    VLAI
    Summary
    Select Dell Client Commercial and Consumer platforms contain an Improper Access Vulnerability. An unauthenticated attacker with physical access to the system could potentially bypass intended Secure Boot restrictions to run unsigned and untrusted code on expansion cards installed in the system during platform boot. Refer to https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en for versions affected by this vulnerability.
    CWE
    • Improper Access Control
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell Dell Client Commercial and Consumer platforms Affected: https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en
    Create a notification for this product.
    Date Public
    2019-07-08 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T19:19:17.451Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Dell Client Commercial and Consumer platforms",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en"
                }
              ]
            }
          ],
          "datePublic": "2019-07-08T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Select Dell Client Commercial and Consumer platforms contain an Improper Access Vulnerability. An unauthenticated attacker with physical access to the system could potentially bypass intended Secure Boot restrictions to run unsigned and untrusted code on expansion cards installed in the system during platform boot. Refer to https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en for versions affected by this vulnerability."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "HIGH",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:L/A:H",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Improper Access Control",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-08-05T16:38:20.000Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.7"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "secure@dell.com",
              "DATE_PUBLIC": "2019-07-08T04:00:00.000Z",
              "ID": "CVE-2019-3717",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Dell Client Commercial and Consumer platforms",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Dell"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Select Dell Client Commercial and Consumer platforms contain an Improper Access Vulnerability. An unauthenticated attacker with physical access to the system could potentially bypass intended Secure Boot restrictions to run unsigned and untrusted code on expansion cards installed in the system during platform boot. Refer to https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en for versions affected by this vulnerability."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.7"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:L/A:H",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Improper Access Control"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en",
                  "refsource": "CONFIRM",
                  "url": "https://www.dell.com/support/article/us/en/04/sln317683/dsa-2019-043-dell-client-improper-access-control-vulnerability?lang=en"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2019-3717",
        "datePublished": "2019-08-05T16:38:20.346Z",
        "dateReserved": "2019-01-03T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:43:43.212Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }