Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for iC7-Automation SP by Danfoss

    CVE-2026-15203 (GCVE-0-2026-15203)

    Vulnerability from nvd – Published: 2026-08-26 05:36 – Updated: 2026-08-26 14:58
    VLAI
    Title
    Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software
    Summary
    Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-26 14:55 UTC
    CWE
    • CWE-1191 - On-Chip debug and test interface with improper access control
    Impacted products
    Vendor Product Version
    Danfoss iC7-Automation SP Affected: 0 , ≤ 2025.3.3 (custom)
    Create a notification for this product.
    Danfoss iC7-Marine Affected: 0 , ≤ 2025.8.19 (custom)
    Create a notification for this product.
    Danfoss iC7-Hybrid Affected: 0 , ≤ 2025.10.300845 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-15203",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-26T14:55:58.163499Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-26T14:58:01.137Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "iC7-Automation SP",
              "vendor": "Danfoss",
              "versions": [
                {
                  "lessThanOrEqual": "2025.3.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iC7-Marine",
              "vendor": "Danfoss",
              "versions": [
                {
                  "lessThanOrEqual": "2025.8.19",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iC7-Hybrid",
              "vendor": "Danfoss",
              "versions": [
                {
                  "lessThanOrEqual": "2025.10.300845",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003e\u003cdiv\u003eImproper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms\u003cbr\u003e\u003c/div\u003e\u003c/div\u003e"
                }
              ],
              "value": "Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms"
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1191",
                  "description": "CWE-1191 On-Chip debug and test interface with improper access control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-26T05:36:02.006Z",
            "orgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
            "shortName": "Danfoss"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003e\u003cul\u003e\u003cli\u003eiC7-Automation SP:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\" title=\"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\"\u003ehttps://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.2.5-26A)\u003c/li\u003e\u003cli\u003eiC7-Marine:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\" title=\"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\"\u003ehttps://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.6.30-GR4.4)\u003c/li\u003e\u003cli\u003eiC7-Hybrid:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\" title=\"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\"\u003ehttps://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.7.2-GR4.5)\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e"
                }
              ],
              "value": "*  iC7-Automation SP:\u00a0 https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip \u00a0(Release\u00a02026.2.5-26A)\n  *  iC7-Marine:\u00a0 https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip \u00a0(Release\u00a02026.6.30-GR4.4)\n  *  iC7-Hybrid:\u00a0 https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip \u00a0(Release\u00a02026.7.2-GR4.5)"
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
        "assignerShortName": "Danfoss",
        "cveId": "CVE-2026-15203",
        "datePublished": "2026-08-26T05:36:02.006Z",
        "dateReserved": "2026-07-09T06:41:49.174Z",
        "dateUpdated": "2026-08-26T14:58:01.137Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-15203 (GCVE-0-2026-15203)

    Vulnerability from cvelistv5 – Published: 2026-08-26 05:36 – Updated: 2026-08-26 14:58
    VLAI
    Title
    Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software
    Summary
    Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-26 14:55 UTC
    CWE
    • CWE-1191 - On-Chip debug and test interface with improper access control
    Impacted products
    Vendor Product Version
    Danfoss iC7-Automation SP Affected: 0 , ≤ 2025.3.3 (custom)
    Create a notification for this product.
    Danfoss iC7-Marine Affected: 0 , ≤ 2025.8.19 (custom)
    Create a notification for this product.
    Danfoss iC7-Hybrid Affected: 0 , ≤ 2025.10.300845 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-15203",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-26T14:55:58.163499Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-26T14:58:01.137Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "iC7-Automation SP",
              "vendor": "Danfoss",
              "versions": [
                {
                  "lessThanOrEqual": "2025.3.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iC7-Marine",
              "vendor": "Danfoss",
              "versions": [
                {
                  "lessThanOrEqual": "2025.8.19",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "iC7-Hybrid",
              "vendor": "Danfoss",
              "versions": [
                {
                  "lessThanOrEqual": "2025.10.300845",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003e\u003cdiv\u003eImproper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms\u003cbr\u003e\u003c/div\u003e\u003c/div\u003e"
                }
              ],
              "value": "Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms"
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1191",
                  "description": "CWE-1191 On-Chip debug and test interface with improper access control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-26T05:36:02.006Z",
            "orgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
            "shortName": "Danfoss"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003e\u003cul\u003e\u003cli\u003eiC7-Automation SP:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\" title=\"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\"\u003ehttps://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.2.5-26A)\u003c/li\u003e\u003cli\u003eiC7-Marine:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\" title=\"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\"\u003ehttps://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.6.30-GR4.4)\u003c/li\u003e\u003cli\u003eiC7-Hybrid:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\" title=\"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\"\u003ehttps://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.7.2-GR4.5)\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e"
                }
              ],
              "value": "*  iC7-Automation SP:\u00a0 https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip \u00a0(Release\u00a02026.2.5-26A)\n  *  iC7-Marine:\u00a0 https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip \u00a0(Release\u00a02026.6.30-GR4.4)\n  *  iC7-Hybrid:\u00a0 https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip \u00a0(Release\u00a02026.7.2-GR4.5)"
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software",
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
        "assignerShortName": "Danfoss",
        "cveId": "CVE-2026-15203",
        "datePublished": "2026-08-26T05:36:02.006Z",
        "dateReserved": "2026-07-09T06:41:49.174Z",
        "dateUpdated": "2026-08-26T14:58:01.137Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }