    CVE-2020-5763 (GCVE-0-2020-5763)

    Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.821Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-489",
                  "description": "CWE-489",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:11.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5763",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-489"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5763",
        "datePublished": "2020-07-29T18:51:50.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.821Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5762 (GCVE-0-2020-5762)

    Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.894Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-476",
                  "description": "CWE-476",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:10.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5762",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-476"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5762",
        "datePublished": "2020-07-29T18:51:47.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.894Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5761 (GCVE-0-2020-5761)

    Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.699Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-835",
                  "description": "CWE-835",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:10.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5761",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-835"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5761",
        "datePublished": "2020-07-29T18:51:43.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.699Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5760 (GCVE-0-2020-5760)

    Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.853Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:09.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5760",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-78"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5760",
        "datePublished": "2020-07-29T18:51:40.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.853Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5763 (GCVE-0-2020-5763)

    Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.821Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-489",
                  "description": "CWE-489",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:11.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5763",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-489"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5763",
        "datePublished": "2020-07-29T18:51:50.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.821Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5762 (GCVE-0-2020-5762)

    Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.894Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-476",
                  "description": "CWE-476",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:10.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5762",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-476"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5762",
        "datePublished": "2020-07-29T18:51:47.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.894Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5761 (GCVE-0-2020-5761)

    Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.699Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-835",
                  "description": "CWE-835",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:10.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5761",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-835"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5761",
        "datePublished": "2020-07-29T18:51:43.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.699Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5760 (GCVE-0-2020-5760)

    Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.853Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:09.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5760",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-78"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5760",
        "datePublished": "2020-07-29T18:51:40.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.853Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }