Search

Find a vulnerability

Search criteria

    12 vulnerabilities found for ht801_firmware by grandstream

    CVE-2021-37915 (GCVE-0-2021-37915)

    Vulnerability from nvd – Published: 2021-10-28 11:11 – Updated: 2024-08-04 01:30
    VLAI
    Summary
    An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:30:09.022Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-28T11:11:28.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-37915",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801",
                  "refsource": "MISC",
                  "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
                },
                {
                  "name": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf",
                  "refsource": "MISC",
                  "url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
                },
                {
                  "name": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/",
                  "refsource": "MISC",
                  "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-37915",
        "datePublished": "2021-10-28T11:11:29.000Z",
        "dateReserved": "2021-08-02T00:00:00.000Z",
        "dateUpdated": "2024-08-04T01:30:09.022Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-37748 (GCVE-0-2021-37748)

    Vulnerability from nvd – Published: 2021-10-28 11:11 – Updated: 2024-08-04 01:30
    VLAI
    Summary
    Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:30:07.528Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/SECFORCE/CVE-2021-37748"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-28T11:11:20.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/SECFORCE/CVE-2021-37748"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-37748",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801",
                  "refsource": "MISC",
                  "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
                },
                {
                  "name": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/",
                  "refsource": "MISC",
                  "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
                },
                {
                  "name": "https://github.com/SECFORCE/CVE-2021-37748",
                  "refsource": "MISC",
                  "url": "https://github.com/SECFORCE/CVE-2021-37748"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-37748",
        "datePublished": "2021-10-28T11:11:20.000Z",
        "dateReserved": "2021-07-30T00:00:00.000Z",
        "dateUpdated": "2024-08-04T01:30:07.528Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5763 (GCVE-0-2020-5763)

    Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.821Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-489",
                  "description": "CWE-489",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:11.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5763",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-489"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5763",
        "datePublished": "2020-07-29T18:51:50.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.821Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5762 (GCVE-0-2020-5762)

    Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.894Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-476",
                  "description": "CWE-476",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:10.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5762",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-476"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5762",
        "datePublished": "2020-07-29T18:51:47.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.894Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5761 (GCVE-0-2020-5761)

    Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.699Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-835",
                  "description": "CWE-835",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:10.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5761",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-835"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5761",
        "datePublished": "2020-07-29T18:51:43.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.699Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5760 (GCVE-0-2020-5760)

    Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.853Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:09.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5760",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-78"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5760",
        "datePublished": "2020-07-29T18:51:40.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.853Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-37915 (GCVE-0-2021-37915)

    Vulnerability from cvelistv5 – Published: 2021-10-28 11:11 – Updated: 2024-08-04 01:30
    VLAI
    Summary
    An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:30:09.022Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-28T11:11:28.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-37915",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801",
                  "refsource": "MISC",
                  "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
                },
                {
                  "name": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf",
                  "refsource": "MISC",
                  "url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
                },
                {
                  "name": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/",
                  "refsource": "MISC",
                  "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-37915",
        "datePublished": "2021-10-28T11:11:29.000Z",
        "dateReserved": "2021-08-02T00:00:00.000Z",
        "dateUpdated": "2024-08-04T01:30:09.022Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-37748 (GCVE-0-2021-37748)

    Vulnerability from cvelistv5 – Published: 2021-10-28 11:11 – Updated: 2024-08-04 01:30
    VLAI
    Summary
    Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T01:30:07.528Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/SECFORCE/CVE-2021-37748"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-10-28T11:11:20.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/SECFORCE/CVE-2021-37748"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-37748",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801",
                  "refsource": "MISC",
                  "url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
                },
                {
                  "name": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/",
                  "refsource": "MISC",
                  "url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
                },
                {
                  "name": "https://github.com/SECFORCE/CVE-2021-37748",
                  "refsource": "MISC",
                  "url": "https://github.com/SECFORCE/CVE-2021-37748"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-37748",
        "datePublished": "2021-10-28T11:11:20.000Z",
        "dateReserved": "2021-07-30T00:00:00.000Z",
        "dateUpdated": "2024-08-04T01:30:07.528Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5763 (GCVE-0-2020-5763)

    Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.821Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-489",
                  "description": "CWE-489",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:11.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5763",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-489"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5763",
        "datePublished": "2020-07-29T18:51:50.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.821Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5762 (GCVE-0-2020-5762)

    Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.894Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-476",
                  "description": "CWE-476",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:10.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5762",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-476"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5762",
        "datePublished": "2020-07-29T18:51:47.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.894Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5761 (GCVE-0-2020-5761)

    Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.699Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-835",
                  "description": "CWE-835",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:10.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5761",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-835"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5761",
        "datePublished": "2020-07-29T18:51:43.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.699Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-5760 (GCVE-0-2020-5760)

    Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
    VLAI
    Summary
    Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    n/a Grandstream HT800 Series Affected: Versions 1.0.17.5 and below
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T08:39:25.853Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-43"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2020-47"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Grandstream HT800 Series",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions 1.0.17.5 and below"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-29T19:06:09.000Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-43"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.tenable.com/security/research/tra-2020-47"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vulnreport@tenable.com",
              "ID": "CVE-2020-5760",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Grandstream HT800 Series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Versions 1.0.17.5 and below"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-78"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-43",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-43"
                },
                {
                  "name": "https://www.tenable.com/security/research/tra-2020-47",
                  "refsource": "MISC",
                  "url": "https://www.tenable.com/security/research/tra-2020-47"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2020-5760",
        "datePublished": "2020-07-29T18:51:40.000Z",
        "dateReserved": "2020-01-06T00:00:00.000Z",
        "dateUpdated": "2024-08-04T08:39:25.853Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",