Search criteria
12 vulnerabilities found for ht801_firmware by grandstream
CVE-2021-37915 (GCVE-0-2021-37915)
Vulnerability from nvd – Published: 2021-10-28 11:11 – Updated: 2024-08-04 01:30
VLAI?
Summary
An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:30:09.022Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-28T11:11:28",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-37915",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801",
"refsource": "MISC",
"url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
},
{
"name": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf",
"refsource": "MISC",
"url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
},
{
"name": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/",
"refsource": "MISC",
"url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-37915",
"datePublished": "2021-10-28T11:11:29",
"dateReserved": "2021-08-02T00:00:00",
"dateUpdated": "2024-08-04T01:30:09.022Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-37748 (GCVE-0-2021-37748)
Vulnerability from nvd – Published: 2021-10-28 11:11 – Updated: 2024-08-04 01:30
VLAI?
Summary
Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:30:07.528Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/SECFORCE/CVE-2021-37748"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-28T11:11:20",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/SECFORCE/CVE-2021-37748"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-37748",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801",
"refsource": "MISC",
"url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
},
{
"name": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/",
"refsource": "MISC",
"url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
},
{
"name": "https://github.com/SECFORCE/CVE-2021-37748",
"refsource": "MISC",
"url": "https://github.com/SECFORCE/CVE-2021-37748"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-37748",
"datePublished": "2021-10-28T11:11:20",
"dateReserved": "2021-07-30T00:00:00",
"dateUpdated": "2024-08-04T01:30:07.528Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5763 (GCVE-0-2020-5763)
Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.821Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "CWE-489",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:11",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5763",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-489"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5763",
"datePublished": "2020-07-29T18:51:50",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.821Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5762 (GCVE-0-2020-5762)
Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.894Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:10",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5762",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-476"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5762",
"datePublished": "2020-07-29T18:51:47",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.894Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5761 (GCVE-0-2020-5761)
Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.699Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-835",
"description": "CWE-835",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:10",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5761",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-835"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5761",
"datePublished": "2020-07-29T18:51:43",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.699Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5760 (GCVE-0-2020-5760)
Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.853Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:09",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5760",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5760",
"datePublished": "2020-07-29T18:51:40",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.853Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-37915 (GCVE-0-2021-37915)
Vulnerability from cvelistv5 – Published: 2021-10-28 11:11 – Updated: 2024-08-04 01:30
VLAI?
Summary
An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:30:09.022Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-28T11:11:28",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-37915",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on the Grandstream HT801 Analog Telephone Adaptor before 1.0.29.8. From the limited configuration shell, it is possible to set the malicious gdb_debug_server variable. As a result, after a reboot, the device downloads and executes malicious scripts from an attacker-defined host."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801",
"refsource": "MISC",
"url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
},
{
"name": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf",
"refsource": "MISC",
"url": "http://firmware.grandstream.com/BETA/Release_Note_HT80x_1.0.29.8.pdf"
},
{
"name": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/",
"refsource": "MISC",
"url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-37915",
"datePublished": "2021-10-28T11:11:29",
"dateReserved": "2021-08-02T00:00:00",
"dateUpdated": "2024-08-04T01:30:09.022Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-37748 (GCVE-0-2021-37748)
Vulnerability from cvelistv5 – Published: 2021-10-28 11:11 – Updated: 2024-08-04 01:30
VLAI?
Summary
Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:30:07.528Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/SECFORCE/CVE-2021-37748"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-28T11:11:20",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/SECFORCE/CVE-2021-37748"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-37748",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple buffer overflows in the limited configuration shell (/sbin/gs_config) on Grandstream HT801 devices before 1.0.29 allow remote authenticated users to execute arbitrary code as root via a crafted manage_if setting, thus bypassing the intended restrictions of this shell and taking full control of the device. There are default weak credentials that can be used to authenticate."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801",
"refsource": "MISC",
"url": "http://www.grandstream.com/products/gateways-and-atas/analog-telephone-adaptors/product/ht801"
},
{
"name": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/",
"refsource": "MISC",
"url": "https://www.secforce.com/blog/exploiting-grandstream-ht801-ata-cve-2021-37748-cve-2021-37915/"
},
{
"name": "https://github.com/SECFORCE/CVE-2021-37748",
"refsource": "MISC",
"url": "https://github.com/SECFORCE/CVE-2021-37748"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-37748",
"datePublished": "2021-10-28T11:11:20",
"dateReserved": "2021-07-30T00:00:00",
"dateUpdated": "2024-08-04T01:30:07.528Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5763 (GCVE-0-2020-5763)
Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.821Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "CWE-489",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:11",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5763",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-489"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5763",
"datePublished": "2020-07-29T18:51:50",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.821Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5762 (GCVE-0-2020-5762)
Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.894Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:10",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5762",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-476"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5762",
"datePublished": "2020-07-29T18:51:47",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.894Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5761 (GCVE-0-2020-5761)
Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.699Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-835",
"description": "CWE-835",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:10",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5761",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-835"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5761",
"datePublished": "2020-07-29T18:51:43",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.699Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5760 (GCVE-0-2020-5760)
Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.853Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:09",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5760",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5760",
"datePublished": "2020-07-29T18:51:40",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.853Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}