FKIE_CVE-2023-37559
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
},
{
"lang": "es",
"value": "Despu\u00e9s de una autenticaci\u00f3n exitosa como usuario en m\u00faltiples productos Codesys en m\u00faltiples versiones, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpAppForce lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda conducir a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37558"
}
],
"id": "CVE-2023-37559",
"lastModified": "2026-06-17T06:08:27.490",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37559",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:28.102576Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.977",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37558
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
},
{
"lang": "es",
"value": "Despu\u00e9s de una autenticaci\u00f3n exitosa como usuario en m\u00faltiples productos Codesys en m\u00faltiples versiones, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpAppForce lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda conducir a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37559"
}
],
"id": "CVE-2023-37558",
"lastModified": "2026-06-17T06:08:27.347",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37558",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:13.616622Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.890",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37557
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
},
{
"lang": "es",
"value": "Despu\u00e9s de una autenticaci\u00f3n exitosa como usuario en m\u00faltiples productos Codesys en m\u00faltiples versiones, solicitudes de comunicaci\u00f3n remota dise\u00f1adas espec\u00edficamente pueden hacer que el componente CmpAppBP sobrescriba un desbordamiento de b\u00fafer, lo que puede conducir a una condici\u00f3n de denegaci\u00f3n de servicio."
}
],
"id": "CVE-2023-37557",
"lastModified": "2026-06-17T06:08:27.190",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37557",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:48:56.664856Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.797",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-37556
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and CVE-2023-37555.\n\n"
},
{
"lang": "es",
"value": "En varias versiones de varios productos Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpAppBP lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda provocar una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 y CVE-2023-37555."
}
],
"id": "CVE-2023-37556",
"lastModified": "2026-06-17T06:08:27.037",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37556",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:03.697246Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.707",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37555
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and\u00a0CVE-2023-37556.\n\n"
},
{
"lang": "es",
"value": "En m\u00faltiples versiones de m\u00faltiples productos de Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, las solicitudes de comunicaci\u00f3n de red espec\u00edficas con contenido inconsistente pueden causar que el componente CmpAppBP lea internamente desde una direcci\u00f3n inv\u00e1lida, potencialmente llevando a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente de CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 y CVE-2023-37556."
}
],
"id": "CVE-2023-37555",
"lastModified": "2026-06-17T06:08:26.887",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37555",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:10.954455Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.620",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37554
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553, CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
},
{
"lang": "es",
"value": "En m\u00faltiples versiones de m\u00faltiples productos de Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, las solicitudes de comunicaci\u00f3n de red espec\u00edficas con contenido inconsistente pueden causar que el componente CmpAppBP lea internamente desde una direcci\u00f3n inv\u00e1lida, potencialmente conduciendo a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente de CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 y CVE-2023-37556."
}
],
"id": "CVE-2023-37554",
"lastModified": "2026-06-17T06:08:26.737",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37554",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:05:06.756495Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.530",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37553
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
},
{
"lang": "es",
"value": "En m\u00faltiples versiones de m\u00faltiples productos de Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, las solicitudes de comunicaci\u00f3n de red con contenido inconsistente pueden causar que el componente CmpAppBP lea internamente desde una direcci\u00f3n inv\u00e1lida, potencialmente llevando a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente de CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 y CVE-2023-37556."
}
],
"id": "CVE-2023-37553",
"lastModified": "2026-06-17T06:08:26.590",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37553",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:05:01.815292Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.443",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37552
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
},
{
"lang": "es",
"value": "En varias versiones de varios productos Codesys, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpAppBP lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda provocar una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 y CVE-2023-37556."
}
],
"id": "CVE-2023-37552",
"lastModified": "2026-06-17T06:08:26.440",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37552",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:04:09.376275Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.353",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37551
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
6.5 (Medium) - CVSS:3.1/
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019/ | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
},
{
"lang": "es",
"value": "En m\u00faltiples productos Codesys en m\u00faltiples versiones , despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, las solicitudes de comunicaci\u00f3n de red especialmente dise\u00f1adas pueden utilizar el componente CmpApp para descargar archivos con cualquier extensi\u00f3n de archivo al controlador. A diferencia de la descarga de archivos normal a trav\u00e9s de CmpFileTransfer, aqu\u00ed no se realiza ning\u00fan filtrado de determinados tipos de archivos. Como resultado, la integridad del sistema de ejecuci\u00f3n de control CODESYS puede verse comprometida por los archivos cargados en el controlador."
}
],
"id": "CVE-2023-37551",
"lastModified": "2026-06-17T06:08:26.290",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37551",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:50.770279Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.257",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-552"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-37550
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\n\n"
},
{
"lang": "es",
"value": "En muchos productos Codesys en m\u00faltiples versiones, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, solicitudes de comunicaci\u00f3n de red espec\u00edficas dise\u00f1adas con contenido inconsistente pueden hacer que el componente CmpApp lea internamente desde una direcci\u00f3n no v\u00e1lida, lo que podr\u00eda conducir a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente a CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 y CVE-2023-37549."
}
],
"id": "CVE-2023-37550",
"lastModified": "2026-06-17T06:08:26.137",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37550",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:46.088420Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.170",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37549
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550\n\n"
},
{
"lang": "es",
"value": "En m\u00faltiples productos de Codesys en m\u00faltiples versiones, despu\u00e9s de una autenticaci\u00f3n exitosa como usuario, solicitudes espec\u00edficas de comunicaci\u00f3n de red con contenido inconsistente pueden causar que el componente CmpApp lea internamente desde una direcci\u00f3n inv\u00e1lida, potencialmente llevando a una condici\u00f3n de denegaci\u00f3n de servicio. Esta vulnerabilidad es diferente de CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 y CVE-2023-37550."
}
],
"id": "CVE-2023-37549",
"lastModified": "2026-06-17T06:08:25.990",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37549",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:40.613696Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:10.083",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37548
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"id": "CVE-2023-37548",
"lastModified": "2026-06-17T06:08:25.840",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37548",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:49.760916Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:09.997",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37547
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"id": "CVE-2023-37547",
"lastModified": "2026-06-17T06:08:25.693",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37547",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:39.095120Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:09.910",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37546
Vulnerability from fkie_nvd - Published: 2023-08-03 12:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"id": "CVE-2023-37546",
"lastModified": "2026-06-17T06:08:25.510",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37546",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:33.810402Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T12:15:09.790",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-37545
Vulnerability from fkie_nvd - Published: 2023-08-03 11:15 - Updated: 2026-06-17 06:08
Severity
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550
References
| URL | Tags | ||
|---|---|---|---|
| info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2023-019 | Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80D9DB34-C2BD-441F-B8D9-02EFA27BECD8",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49AA0C0C-F2F2-4F11-9615-FDCA6BC410B4",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74FE662F-5397-4CB7-9243-1E6ED0AAEC29",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8896E77C-EB29-4CB9-BC98-D5A34791A961",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56101551-21ED-4409-9932-9EFA225AF20C",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1239AA8-B094-4DA3-82B7-38F85B6C3940",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAA7FE72-41A0-42E7-8E66-9B4A50A5B08F",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C248B53C-3C09-4068-9E57-8F9A4D2B7AD0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7995687-1BCD-454D-8546-52B80B5F22B0",
"versionEndExcluding": "4.10.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC253D-32BC-4B9E-BDEE-CFFDCDBBE9FB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "297D8781-B331-40B2-BD34-0041A316D5C8",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA76230A-C7E7-4223-BAB7-4CDE8F5CB5DB",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09CC9B78-B3B4-4D49-9F23-DC5C80D52588",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACDCB65A-1328-422D-99A0-1D0FFE9AC793",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81E2FE85-347D-42DE-9360-D5DB79AAD085",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7DF2418-1EC1-4672-941E-098EBC9BDF4F",
"versionEndExcluding": "3.5.19.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550\n\n"
}
],
"id": "CVE-2023-37545",
"lastModified": "2026-06-17T06:08:25.257",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-37545",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:27.383050Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-08-03T11:15:09.837",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-30792
Vulnerability from fkie_nvd - Published: 2022-07-11 11:15 - Updated: 2026-06-17 04:44
Severity
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/
Summary
In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Gateway",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Edge Gateway for Windows",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.10",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Embedded Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Remote Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for Beckhoff CX9020 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Edge Gateway for Linux",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B5D6E827-7AD1-4248-82E6-C879771A2FBA",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E07464D3-D8E5-45CC-8703-B445A866F015",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AD1474A7-A282-4929-A9E4-721322DCAE15",
"versionEndExcluding": "4.6.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AB585AB5-D0AC-46DC-9723-A0FEFBFB015C",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4F6E2A1D-0187-4C71-A87D-48B3EC3D99DD",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A78E493B-6D9E-4196-830C-24BCF25D3D44",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BD0BCA34-FE68-4933-B189-746D2DA3E062",
"versionEndExcluding": "4.6.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9D5DE9D1-C334-452C-A64B-D74A48017B6D",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600:*:*:*:*:*:*:*:*",
"matchCriteriaId": "966AEA54-4939-4C84-8D8B-7C70D361555B",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A33E4442-F316-439F-83BD-047A34EF6E14",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "8AC245C1-F19D-417A-801E-D08B0ED81651",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F1A0B9C6-534C-4D2C-BC62-620786CE748F",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "22F16730-93D3-41D4-B5D0-F507BC2D5A03",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "05792C1C-C4BB-4084-96A3-69544076F944",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:edge_gateway:*:*:*:*:*:windows:*:*",
"matchCriteriaId": "6C919501-6AFE-4D4C-84EF-C6AF30EBB769",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:edge_gateway:*:*:*:*:*:linux:*:*",
"matchCriteriaId": "E36291AE-21CB-4ECB-8816-D50712C70E30",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "26B19D43-1A55-45E5-9C0A-00E9487B4282",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "73C1F863-AAC0-446A-98E1-436916DA66B9",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C26E9A35-AEB3-4856-8410-989D422A6D95",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "26CA4951-7DD0-4477-8C36-EC07191CAC8F",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected."
},
{
"lang": "es",
"value": "En CmpChannelServer de CODESYS versi\u00f3n V3 en m\u00faltiples versiones un consumo no controlado de recursos permite a un atacante no autorizado bloquear nuevas conexiones de canales de comunicaci\u00f3n. Las conexiones existentes no est\u00e1n afectadas"
}
],
"id": "CVE-2022-30792",
"lastModified": "2026-06-17T04:44:18.923",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
},
"published": "2022-07-11T11:15:08.240",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-30791
Vulnerability from fkie_nvd - Published: 2022-07-11 11:15 - Updated: 2026-06-17 04:44
Severity
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/
Summary
In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Gateway",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Edge Gateway for Windows",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.10",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Embedded Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Remote Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.18.20",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for Beckhoff CX9020 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
},
{
"product": "CODESYS Edge Gateway for Linux",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.5.0.0",
"status": "affected",
"version": "V3",
"versionType": "custom"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B5D6E827-7AD1-4248-82E6-C879771A2FBA",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E07464D3-D8E5-45CC-8703-B445A866F015",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AD1474A7-A282-4929-A9E4-721322DCAE15",
"versionEndExcluding": "4.6.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AB585AB5-D0AC-46DC-9723-A0FEFBFB015C",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4F6E2A1D-0187-4C71-A87D-48B3EC3D99DD",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A78E493B-6D9E-4196-830C-24BCF25D3D44",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BD0BCA34-FE68-4933-B189-746D2DA3E062",
"versionEndExcluding": "4.6.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9D5DE9D1-C334-452C-A64B-D74A48017B6D",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600:*:*:*:*:*:*:*:*",
"matchCriteriaId": "966AEA54-4939-4C84-8D8B-7C70D361555B",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A33E4442-F316-439F-83BD-047A34EF6E14",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*",
"matchCriteriaId": "8AC245C1-F19D-417A-801E-D08B0ED81651",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F1A0B9C6-534C-4D2C-BC62-620786CE748F",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "22F16730-93D3-41D4-B5D0-F507BC2D5A03",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "05792C1C-C4BB-4084-96A3-69544076F944",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:edge_gateway:*:*:*:*:*:windows:*:*",
"matchCriteriaId": "6C919501-6AFE-4D4C-84EF-C6AF30EBB769",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:edge_gateway:*:*:*:*:*:linux:*:*",
"matchCriteriaId": "E36291AE-21CB-4ECB-8816-D50712C70E30",
"versionEndExcluding": "4.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "26B19D43-1A55-45E5-9C0A-00E9487B4282",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "73C1F863-AAC0-446A-98E1-436916DA66B9",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C26E9A35-AEB3-4856-8410-989D422A6D95",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "26CA4951-7DD0-4477-8C36-EC07191CAC8F",
"versionEndExcluding": "3.5.18.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected."
},
{
"lang": "es",
"value": "En CmpBlkDrvTcp de CODESYS versi\u00f3n V3 en m\u00faltiples versiones un consumo no controlado de recursos permite a un atacante no autorizado bloquear nuevas conexiones TCP. Las conexiones existentes no est\u00e1n afectadas"
}
],
"id": "CVE-2022-30791",
"lastModified": "2026-06-17T04:44:18.740",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
},
"published": "2022-07-11T11:15:08.177",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download="
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-36763
Vulnerability from fkie_nvd - Published: 2021-08-03 16:15 - Updated: 2026-06-17 03:59
Severity
Summary
In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control_rte | * | |
| codesys | control_rte | * | |
| codesys | control_runtime_system_toolkit | * | |
| codesys | control_win_sl | * | |
| codesys | embedded_target_visu_toolkit | * | |
| codesys | hmi | * | |
| codesys | remote_target_visu_toolkit | * |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:beaglebone_sl:*:*",
"matchCriteriaId": "57DD6E2E-9B12-4C30-9CCF-26C5EFCFC0EA",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:empc-a\\/imx6_sl:*:*",
"matchCriteriaId": "79E8DFCC-74F7-4B0D-A476-D13CBB32EDEF",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:iot2000_sl:*:*",
"matchCriteriaId": "58160302-830A-463B-AE5F-782B01893F40",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:linux_sl:*:*",
"matchCriteriaId": "2E740918-B35E-4583-8580-046A7C7F3113",
"versionEndIncluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:pfc100_sl:*:*",
"matchCriteriaId": "F00E63D5-8CA2-4082-B522-4B0C51772A4C",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:pfc200_sl:*:*",
"matchCriteriaId": "6890F3F3-6DF2-4D0C-A431-B3705900E1EB",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:plcnext_sl:*:*",
"matchCriteriaId": "7D6CA947-A0F3-4F45-804B-BAD4BD24CBC4",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:raspberry_pi_sl:*:*",
"matchCriteriaId": "1545D5A9-739E-4C36-933A-B87A3D593A22",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:wago_touch_panels_600_sl:*:*",
"matchCriteriaId": "7D0A2D1F-F297-4D5D-8FB1-1C80297E91A1",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:-:*:*",
"matchCriteriaId": "102C898A-8CA9-4C6E-AAAD-ED947F6DCEA2",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:beckhoff_cx:*:*",
"matchCriteriaId": "C629084B-E59E-4FA4-A866-7F2FE8C6D26B",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48B1957E-472D-4A21-A8FC-DF2AF0C118F5",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FBCFD26C-0262-4D2B-99CA-E7EA0E6B75E3",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B640C5A9-8241-4191-87F6-E31D6902702E",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9116B38E-7B7C-48DB-B742-A8741EB63892",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C86F931B-F172-4B00-B484-48048756655F",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties."
},
{
"lang": "es",
"value": "En CODESYS V3 web server versiones anteriores a 3.5.17.10, los archivos o directorios son accesibles para las partes externas"
}
],
"id": "CVE-2021-36763",
"lastModified": "2026-06-17T03:59:07.600",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-08-03T16:15:08.657",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=16803\u0026token=0b8edf9276dc39ee52f43026c415c5b38085d90a\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=16803\u0026token=0b8edf9276dc39ee52f43026c415c5b38085d90a\u0026download="
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-552"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-33485
Vulnerability from fkie_nvd - Published: 2021-08-03 16:15 - Updated: 2026-06-17 03:54
Severity
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/
Summary
CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control | * | |
| codesys | control_rte | * | |
| codesys | control_rte | * | |
| codesys | control_runtime_system_toolkit | * | |
| codesys | control_win_sl | * | |
| codesys | embedded_target_visu_toolkit | * | |
| codesys | hmi | * | |
| codesys | remote_target_visu_toolkit | * |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:beaglebone_sl:*:*",
"matchCriteriaId": "57DD6E2E-9B12-4C30-9CCF-26C5EFCFC0EA",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:empc-a\\/imx6_sl:*:*",
"matchCriteriaId": "79E8DFCC-74F7-4B0D-A476-D13CBB32EDEF",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:iot2000_sl:*:*",
"matchCriteriaId": "58160302-830A-463B-AE5F-782B01893F40",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:linux_sl:*:*",
"matchCriteriaId": "2E740918-B35E-4583-8580-046A7C7F3113",
"versionEndIncluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:pfc100_sl:*:*",
"matchCriteriaId": "F00E63D5-8CA2-4082-B522-4B0C51772A4C",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:pfc200_sl:*:*",
"matchCriteriaId": "6890F3F3-6DF2-4D0C-A431-B3705900E1EB",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:plcnext_sl:*:*",
"matchCriteriaId": "7D6CA947-A0F3-4F45-804B-BAD4BD24CBC4",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:raspberry_pi_sl:*:*",
"matchCriteriaId": "1545D5A9-739E-4C36-933A-B87A3D593A22",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control:*:*:*:*:*:wago_touch_panels_600_sl:*:*",
"matchCriteriaId": "7D0A2D1F-F297-4D5D-8FB1-1C80297E91A1",
"versionEndExcluding": "4.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:-:*:*",
"matchCriteriaId": "102C898A-8CA9-4C6E-AAAD-ED947F6DCEA2",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:beckhoff_cx:*:*",
"matchCriteriaId": "C629084B-E59E-4FA4-A866-7F2FE8C6D26B",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48B1957E-472D-4A21-A8FC-DF2AF0C118F5",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FBCFD26C-0262-4D2B-99CA-E7EA0E6B75E3",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B640C5A9-8241-4191-87F6-E31D6902702E",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9116B38E-7B7C-48DB-B742-A8741EB63892",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C86F931B-F172-4B00-B484-48048756655F",
"versionEndExcluding": "3.5.17.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow."
},
{
"lang": "es",
"value": "CODESYS Control Runtime system versiones anteriores a 3.5.17.10, presenta un Desbordamiento de Buffer en la regi\u00f3n Heap de la memoria"
}
],
"id": "CVE-2021-33485",
"lastModified": "2026-06-17T03:54:39.427",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2021-33485",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:02:26.023609Z",
"version": "2.0.3"
}
}
]
},
"published": "2021-08-03T16:15:08.583",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14805\u0026token=f0b86f99bb302ddd4aadec483aed5f5d3fddbf1a\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14805\u0026token=f0b86f99bb302ddd4aadec483aed5f5d3fddbf1a\u0026download="
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-122"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2021-29242
Vulnerability from fkie_nvd - Published: 2021-05-03 14:15 - Updated: 2026-06-17 03:47
Severity
Summary
CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://customers.codesys.com/index.php | Permissions Required, Vendor Advisory | |
| cve@mitre.org | https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=14640&token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873&download= | Vendor Advisory | |
| cve@mitre.org | https://www.codesys.com/security/security-reports.html | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://customers.codesys.com/index.php | Permissions Required, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=14640&token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873&download= | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.codesys.com/security/security-reports.html | Vendor Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5EA5176A-EC2A-4D06-A180-CE7204DBAF92",
"versionEndExcluding": "4.1.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "089B01CE-0023-44E9-8149-95A9C8BFC544",
"versionEndExcluding": "4.1.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "150D1F73-22B1-4B41-97A0-B02EF5CE92A9",
"versionEndExcluding": "4.1.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "11A71DCF-8007-4693-BD0F-22FCD0FC0C62",
"versionEndExcluding": "4.1.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6ADB2C58-D545-451E-BE60-7B989E9EBCEF",
"versionEndExcluding": "4.1.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6C535337-0082-4C76-B9E9-E0F9EA4D1E36",
"versionEndExcluding": "4.1.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ADCF1EDB-6FED-4421-BF16-A14EE6EB0505",
"versionEndExcluding": "4.1.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9DB284A7-76D5-4BD1-972B-751AC0B378D8",
"versionEndExcluding": "4.1.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BA3C058E-AE70-4E64-B3A0-60DED7A26B18",
"versionEndExcluding": "4.1.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"matchCriteriaId": "67D475FB-BF84-4EEE-B096-8B81C2ED36A5",
"versionEndExcluding": "4.1.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "64A83FD0-A545-459B-860F-70DE8E4A69DC",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:beckhoff_cx:*:*",
"matchCriteriaId": "9BFCCFA4-A803-4B5E-BAD5-C26A6FE33A4C",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0224CA62-8670-4135-9A50-5E523D89CB25",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "25458B55-414D-4CB4-BD51-4E4D101BB24A",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:edge_gateway:*:*:*:*:*:windows:*:*",
"matchCriteriaId": "E331194D-C80D-4C81-A332-9F67F6425FD0",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:edge_gateway:*:*:*:*:*:linux:*:*",
"matchCriteriaId": "FFBA19D6-9436-4E14-B9D3-28B82CB0321D",
"versionEndExcluding": "4.1.0.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A59EBA23-C9F0-4A7A-9483-2EB9377023CE",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E3954149-77D5-4FEE-B236-578D0ED18592",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A39C361B-514B-423C-B917-2E13935DF1A9",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:opc_server:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E59EF90A-4580-41AD-8DAB-1259C766E230",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:plchandler:*:*:*:*:*:*:*:*",
"matchCriteriaId": "242B0BB4-1E48-4CD1-AFF3-F96561D2A885",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "74AB840C-88D7-47CA-8716-0C0F6ABEE8E2",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FEF5325B-B72B-46BB-9DCB-F8054621DA6D",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:simulation_runtime:*:*:*:*:*:*:*:*",
"matchCriteriaId": "61972DA3-9423-4C13-98E3-F287BD414A59",
"versionEndExcluding": "3.5.17.0",
"versionStartIncluding": "3.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router\u0027s addressing scheme and may re-route, add, remove or change low level communication packages."
},
{
"lang": "es",
"value": "El sistema CODESYS Control Runtime versiones anteriores a 3.5.17.0, presenta una comprobaci\u00f3n inapropiada de entrada.\u0026#xa0;Los atacantes pueden enviar paquetes de comunicaci\u00f3n dise\u00f1ados para cambiar el esquema de direccionamiento del enrutador y pueden redireccionar, agregar, eliminar o cambiar paquetes de comunicaci\u00f3n de bajo nivel."
}
],
"id": "CVE-2021-29242",
"lastModified": "2026-06-17T03:47:26.127",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-05-03T14:15:07.667",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.codesys.com/security/security-reports.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=14640\u0026token=623b6fceb0579ef0f7505e29beefa5b3f8ac7873\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.codesys.com/security/security-reports.html"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-7052
Vulnerability from fkie_nvd - Published: 2020-01-24 20:15 - Updated: 2026-06-17 03:24
Severity
Summary
CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B4E5BF9F-79C9-48D3-9F2D-CCDF73144FCA",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "221CAFE3-1BC7-4CAC-B3F8-981B3F267CFE",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9B048CEB-E1D0-4EF1-9BD3-966CB9E147D8",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A72217A3-4591-4C52-AB37-7FD652276569",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
"matchCriteriaId": "51EFD6C4-C1AC-45D7-909F-6B074B32090E",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8C1B75F5-F426-4877-9004-1F714B2A4968",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2F150E51-4E03-40A8-8099-E5BE13234DD9",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8D839D59-8090-4158-A2C2-847DEDD9674D",
"versionEndExcluding": "3.5.15.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E278A9AE-5684-4F7E-B253-0F70CA835322",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.5.8.60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:beckhoff_cx:*:*",
"matchCriteriaId": "650315EF-4AC2-4B5B-A5A1-8ABBE6C398B6",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.5.8.60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B8C46635-3068-4DDA-8527-2E473763E652",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B7F22E48-0C8D-47C2-8C88-F35ED1027465",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.5.9.80",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5A487191-D2CD-484B-88D3-C7A1EFD8C19B",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.5.15.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0B3462D2-9AA7-4046-B491-36A2A9970BA7",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.5.10.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4F4FCCC9-6069-47D6-AB46-65697F7AE58D",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:simulation_runtime:*:*:*:*:*:*:*:*",
"matchCriteriaId": "375689F5-9B58-491C-BD1C-2CF5C9CEB474",
"versionEndExcluding": "3.5.15.30",
"versionStartIncluding": "3.5.9.40",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition."
},
{
"lang": "es",
"value": "CODESYS Control versi\u00f3n V3, Gateway versi\u00f3n V3 y HMI versiones V3 anteriores a 3.5.15.30, permiten una asignaci\u00f3n de memoria no controlada que puede resultar en una condici\u00f3n de denegaci\u00f3n de servicio remota."
}
],
"id": "CVE-2020-7052",
"lastModified": "2026-06-17T03:24:14.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-01-24T20:15:10.970",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12977\u0026token=33f948eed0c2fd69d238d9515779be337ef7592d\u0026download="
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12977\u0026token=33f948eed0c2fd69d238d9515779be337ef7592d\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-04"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-770"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-15806
Vulnerability from fkie_nvd - Published: 2020-07-22 19:15 - Updated: 2026-06-17 02:57
Severity
Summary
CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=13199&token=3e283c3e73fed61f7c181a7fa1169477efaf0c58&download= | Mitigation, Vendor Advisory | |
| cve@mitre.org | https://www.codesys.com | Vendor Advisory | |
| cve@mitre.org | https://www.tenable.com/security/research/tra-2020-46 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=13199&token=3e283c3e73fed61f7c181a7fa1169477efaf0c58&download= | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.codesys.com | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2020-46 | Exploit, Third Party Advisory |
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4AE57E7D-63C1-470F-A95B-B9DA3A586E04",
"versionEndExcluding": "3.5.16.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7B5F06D0-5224-4D76-A856-9AB57BF87D59",
"versionEndExcluding": "3.5.16.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CB388FBB-8512-4FCE-A754-A82239A911B9",
"versionEndExcluding": "3.5.16.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux:*:*:*:*:*:*:*:*",
"matchCriteriaId": "41722BB1-40F6-4D12-9A00-156D04C92097",
"versionEndExcluding": "3.5.16.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5E56A636-9DC3-411D-B287-308A2BAC759D",
"versionEndExcluding": "3.5.16.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
"matchCriteriaId": "82614FBA-2612-4FA4-988B-D67E80B5DDA7",
"versionEndExcluding": "3.5.16.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext:*:*:*:*:*:*:*:*",
"matchCriteriaId": "387FB2B8-5435-4054-94A4-0AE60A42FB0C",
"versionEndExcluding": "3.5.16.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4B7517E0-0D9C-4AA8-B8A9-7F1420FE4616",
"versionEndExcluding": "3.5.16.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1C80CDF5-5264-41CD-A475-E46C3E941F4A",
"versionEndExcluding": "3.5.16.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:-:*:*",
"matchCriteriaId": "6097C902-F24A-4408-8E2C-C90F0AB67E13",
"versionEndExcluding": "3.5.16.10",
"versionStartIncluding": "3.5.8.60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:beckhoff_cx:*:*",
"matchCriteriaId": "2DDE8129-4CEE-440B-B0D1-29BB93D1ACE8",
"versionEndExcluding": "3.5.16.10",
"versionStartIncluding": "3.5.8.60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6CF52B1D-7AF9-4DAD-A8E7-6CB7CC060E08",
"versionEndExcluding": "3.5.16.10",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E86A4C83-B82D-4D2F-96C6-C8F66B7AB947",
"versionEndExcluding": "3.5.16.10",
"versionStartIncluding": "3.5.9.80",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "890104AC-5CB4-466D-9CC0-F39E8B24BD9D",
"versionEndExcluding": "3.5.16.10",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7CE9850A-47B3-4C37-90C0-FF9516DF025F",
"versionEndExcluding": "3.5.16.10",
"versionStartIncluding": "3.5.10.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "31C2638C-D4C4-4C71-A873-E7836802E6FE",
"versionEndExcluding": "3.5.16.10",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:simulation_runtime:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9A09DAE1-678B-49A2-88CE-CFF4F514673E",
"versionEndExcluding": "3.5.16.10",
"versionStartIncluding": "3.5.9.40",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation."
},
{
"lang": "es",
"value": "El sistema del tiempo de ejecuci\u00f3n de Control CODESYS, versiones anteriores a 3.5.16.10, permite una Asignaci\u00f3n de Memoria No Controlada"
}
],
"id": "CVE-2020-15806",
"lastModified": "2026-06-17T02:57:13.557",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-07-22T19:15:12.317",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=13199\u0026token=3e283c3e73fed61f7c181a7fa1169477efaf0c58\u0026download="
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.codesys.com"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-46"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=13199\u0026token=3e283c3e73fed61f7c181a7fa1169477efaf0c58\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.codesys.com"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-46"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-401"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-12068
Vulnerability from fkie_nvd - Published: 2020-05-14 21:15 - Updated: 2026-06-17 02:51
Severity
Summary
An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2A5313A0-4D9B-4B1F-B432-F84130717DE7",
"versionEndExcluding": "3.5.16.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C9EA03EF-F424-4AC6-AC0B-A284A2553092",
"versionEndExcluding": "3.5.16.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "38ECECFA-13C2-459E-B509-5F663E72CDE9",
"versionEndExcluding": "3.5.16.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B7BD8B5A-8CD7-463C-82D7-06F6DE7E6DB0",
"versionEndExcluding": "3.5.16.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1CC12843-4775-46BF-BB7F-35D7A4825027",
"versionEndExcluding": "3.5.16.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext:*:*:*:*:*:*:*:*",
"matchCriteriaId": "84E46BF9-F5A0-4C09-BE2B-486263D89E85",
"versionEndExcluding": "3.5.16.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C17614A6-F334-4955-824D-A237A9672ECD",
"versionEndExcluding": "3.5.16.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BFAF3E76-D917-48FA-BE80-7CEF592359F3",
"versionEndExcluding": "3.5.16.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "977B88F5-FA46-41A6-B65E-034EEBA19755",
"versionEndExcluding": "3.5.16.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C6E1A555-20F2-4C1D-824C-9BFE5A8C1184",
"versionEndExcluding": "3.5.16.0",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "03FB53F8-F076-41FB-B556-077F99584B76",
"versionEndExcluding": "3.5.16.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C2B23429-F3C9-4414-A3C8-FDEA5D0DFE96",
"versionEndExcluding": "3.5.16.0",
"versionStartIncluding": "3.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en CODESYS Development System versiones anteriores a 3.5.16.0. CODESYS WebVisu y CODESYS Remote TargetVisu son susceptibles a una escalada de privilegios."
}
],
"id": "CVE-2020-12068",
"lastModified": "2026-06-17T02:51:22.310",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 2.5,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-05-14T21:15:13.260",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=13136\u0026token=c267875c01ea70bc9613bc39c684eedc17f55420\u0026download="
},
{
"source": "cve@mitre.org",
"tags": [
"Product"
],
"url": "https://www.codesys.com"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=13136\u0026token=c267875c01ea70bc9613bc39c684eedc17f55420\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://www.codesys.com"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-10245
Vulnerability from fkie_nvd - Published: 2020-03-26 04:15 - Updated: 2026-06-17 02:47
Severity
Summary
CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0EA61ACB-5690-42D7-8420-E77E58D5BA4D",
"versionEndExcluding": "3.5.15.40",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A5FB5ED1-0B3C-4426-AC3E-621C230AE38C",
"versionEndExcluding": "3.5.15.40",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1477C3BF-2636-4D41-B951-CED7CAE6731A",
"versionEndExcluding": "3.5.15.40",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux:*:*:*:*:*:*:*:*",
"matchCriteriaId": "82047F2C-2D3D-4D6C-9DAE-512BD9639747",
"versionEndExcluding": "3.5.15.40",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E832FD04-9206-4881-8695-8FA7FE788EE7",
"versionEndExcluding": "3.5.15.40",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C21D2A80-B830-483F-A748-2F082D369C73",
"versionEndExcluding": "3.5.15.40",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9CD92E41-9C0A-47E0-8B90-181A2ECC4627",
"versionEndExcluding": "3.5.15.40",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "491C7EFF-D620-40EB-B112-9D0B2AC62B76",
"versionEndExcluding": "3.5.15.40",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "75BA05C4-3066-4354-9F99-232D181D0CA6",
"versionEndExcluding": "3.5.15.40",
"versionStartIncluding": "3.5.8.60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:beckhoff_cx:*:*",
"matchCriteriaId": "D3281307-8315-42A5-84FD-C683C54B603A",
"versionEndExcluding": "3.5.15.40",
"versionStartIncluding": "3.5.8.60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E095D809-8408-4FEE-874F-1F021EC7E97E",
"versionEndExcluding": "3.5.15.40",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "43EBED50-DFA9-430B-8B3C-8994E2E43470",
"versionEndExcluding": "3.5.15.40",
"versionStartIncluding": "3.5.9.80",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93ACEEA3-B958-4070-86F0-5C84869A13E7",
"versionEndExcluding": "3.5.15.40",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A4CF0416-A09F-46CF-8285-A46E7F1A2F8C",
"versionEndExcluding": "3.5.15.40",
"versionStartIncluding": "3.5.10.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CBC06C9A-3D60-46FF-BCF4-B1C472DB3850",
"versionEndExcluding": "3.5.15.40",
"versionStartIncluding": "3.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow."
},
{
"lang": "es",
"value": "El servidor web CODESYS versiones V3 anteriores a 3.5.15.40, como es usado en los sistemas de tiempo de ejecuci\u00f3n CODESYS Control, presenta un desbordamiento del b\u00fafer."
}
],
"id": "CVE-2020-10245",
"lastModified": "2026-06-17T02:47:33.447",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-03-26T04:15:11.533",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=13078\u0026token=de344ca65252463cc581ef144e0c53bd97b8f211\u0026download="
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-16"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=13078\u0026token=de344ca65252463cc581ef144e0c53bd97b8f211\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-16"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-9009
Vulnerability from fkie_nvd - Published: 2019-09-17 16:15 - Updated: 2026-06-17 02:42
Severity
Summary
An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12941&token=50fabe3870c7bdc41701eb1799dddeec103de40c&download= | Vendor Advisory | |
| cve@mitre.org | https://www.us-cert.gov/ics/advisories/icsa-19-255-05 | Mitigation, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12941&token=50fabe3870c7bdc41701eb1799dddeec103de40c&download= | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-255-05 | Mitigation, Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| codesys | control_for_beaglebone | * | |
| codesys | control_for_empc-a\/imx6 | * | |
| codesys | control_for_iot2000 | * | |
| codesys | control_for_pfc100 | * | |
| codesys | control_for_pfc200 | * | |
| codesys | control_for_raspberry_pi | * | |
| codesys | control_rte | * | |
| codesys | control_win | * | |
| codesys | gateway | * | |
| codesys | hmi | * | |
| codesys | linux | * | |
| codesys | runtime_system_toolkit | * | |
| codesys | safety_sil2 | * | |
| codesys | simulation_runtime | * |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "958821C8-142A-4B67-857B-63A6AD53E1B8",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B9940444-8CFD-4044-8662-FDC11E93E6E4",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "805D48DF-DA8F-40AB-B7AE-B2F0A75616E9",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EAEAC81A-4FFA-4692-961D-7DF58E2B0CDE",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2506A775-D1FB-4C2F-98EC-B781AA19E340",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "963C9351-B167-4C1F-914E-A7009A532A0F",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0A5F978B-5245-41D9-B11C-B27703A2A090",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1429532E-76A8-4987-B916-AA3FD7C37E06",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "563FD9B0-D6F5-4A4C-A43D-555C2DC60DD4",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ABFC0D89-BD79-4032-B0CA-08C4F8EA1776",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:linux:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4A2B09D6-8FD2-46FA-A1B2-55B7E996D71B",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "417EFF04-1584-44C3-8AD9-593174089A31",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*",
"matchCriteriaId": "139851DD-0E16-4C8D-AA55-0231B2C443A7",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:simulation_runtime:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3FB11CE8-8B22-4D2D-A0A9-4D23C30A3FF5",
"versionEndExcluding": "3.5.15.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash."
},
{
"lang": "es",
"value": "Se descubri\u00f3 un problema en 3S-Smart CODESYS versiones anteriores a 3.5.15.0. Unos paquetes de red dise\u00f1ados causan que el Control Runtime se bloquee."
}
],
"id": "CVE-2019-9009",
"lastModified": "2026-06-17T02:42:54.843",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-09-17T16:15:11.077",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12941\u0026token=50fabe3870c7bdc41701eb1799dddeec103de40c\u0026download="
},
{
"source": "cve@mitre.org",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-05"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12941\u0026token=50fabe3870c7bdc41701eb1799dddeec103de40c\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-05"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-755"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-9008
Vulnerability from fkie_nvd - Published: 2019-09-17 14:15 - Updated: 2026-06-17 02:42
Severity
Summary
An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12939&token=5b93f0d95a68ff7461d2c249d8da00f16b8f9987&download= | Vendor Advisory | |
| cve@mitre.org | https://www.codesys.com/ | Vendor Advisory | |
| cve@mitre.org | https://www.us-cert.gov/ics/advisories/icsa-19-255-03 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12939&token=5b93f0d95a68ff7461d2c249d8da00f16b8f9987&download= | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.codesys.com/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-255-03 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| codesys | control_for_beaglebone | * | |
| codesys | control_for_empc-a\/imx6 | * | |
| codesys | control_for_iot2000 | * | |
| codesys | control_for_pfc100 | * | |
| codesys | control_for_pfc200 | * | |
| codesys | control_for_raspberry_pi | * | |
| codesys | control_rte | * | |
| codesys | control_win | * | |
| codesys | hmi | * | |
| codesys | simulation_runtime | * |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A5C54235-616B-47A4-A1C5-E8AB7347AFAC",
"versionEndExcluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0AF7E264-FB36-4BB4-8A8F-4437D637334F",
"versionEndExcluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9EB64F24-4001-4874-83D3-38413FC94ADD",
"versionEndExcluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E3A61193-758A-4540-A039-1C8DC0D61B67",
"versionEndExcluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
"matchCriteriaId": "54022CAB-4847-4E4F-AB14-172649195ACB",
"versionEndExcluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "43B850F0-C963-4C99-9D66-6D72936B4CD7",
"versionEndExcluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C62EF2A3-DF28-4B1E-91C3-25F105CDCA39",
"versionEndExcluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CF2E5D2E-2E4C-44B1-8A17-58439295ADE1",
"versionEndExcluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "35EE8235-EF64-4FF7-AFD5-F14D7C0A7BCF",
"versionEndExcluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:simulation_runtime:*:*:*:*:*:*:*:*",
"matchCriteriaId": "44D78350-294B-4477-828D-C9289A1D985E",
"versionEndExcluding": "3.5.13.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en 3S-Smart CODESYS V3 versiones hasta 3.5.12.30. Un usuario con pocos privilegios puede tomar el control total sobre el tiempo de ejecuci\u00f3n."
}
],
"id": "CVE-2019-9008",
"lastModified": "2026-06-17T02:42:54.730",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-09-17T14:15:10.890",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12939\u0026token=5b93f0d95a68ff7461d2c249d8da00f16b8f9987\u0026download="
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.codesys.com/"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=12939\u0026token=5b93f0d95a68ff7461d2c249d8da00f16b8f9987\u0026download="
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.codesys.com/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-03"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-18858
Vulnerability from fkie_nvd - Published: 2019-11-20 18:15 - Updated: 2026-06-17 02:25
Severity
Summary
CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0EC6B28E-A811-41B3-8211-5C00F43501B0",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C35E21FB-D148-4295-8F6E-250276198B78",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5B3FD146-88C2-4091-9A95-5F1734B4FBC9",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9A300E3F-5BF6-455E-ADDC-D7443254F049",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1502A884-95A6-4587-8EFA-82374251CD3A",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
"matchCriteriaId": "02BEA387-FF44-4AF9-8B80-CD8D6E7F4549",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_plcnext:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8D16B0FB-C69F-4D02-9598-22ADD027D9AA",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AA7D956E-7844-4F3D-BF27-E38E5D2B0A68",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "15CFC3A8-1D5C-486E-97CB-0F38E9874B96",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "02ED0463-8628-488A-B931-683A2C0205B9",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9CFF4CBE-6291-479D-BC3C-379C7F7D8337",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A4D32C64-2C59-461B-8E33-A4EDF31E886E",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "95BE3C03-7A36-4AD8-B5E9-BD91BD729B72",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1451AE82-855F-425C-9C30-2B96F4B8F2EC",
"versionEndExcluding": "3.5.15.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow."
},
{
"lang": "es",
"value": "El servidor web CODESYS 3 versiones anteriores a la versi\u00f3n 3.5.15.20, distribuido con los sistemas de tiempo de ejecuci\u00f3n CODESYS Control, tiene un desbordamiento de b\u00fafer."
}
],
"id": "CVE-2019-18858",
"lastModified": "2026-06-17T02:25:29.023",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-11-20T18:15:10.917",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/fileadmin/data/customers/security/2019/Advisory2019-10_CDS-68341.pdf"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2019-48"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://customers.codesys.com/fileadmin/data/customers/security/2019/Advisory2019-10_CDS-68341.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2019-48"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-13548
Vulnerability from fkie_nvd - Published: 2019-09-13 17:15 - Updated: 2026-06-17 02:16
Severity
Summary
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.us-cert.gov/ics/advisories/icsa-19-255-01 | Mitigation, Patch, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-255-01 | Mitigation, Patch, Third Party Advisory, US Government Resource |
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "CODESYS V3 web server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "all versions prior to 3.5.14.10"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BC95996F-4E60-4CCE-BC7D-2F998969455D",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CCE0D6F6-86D9-488A-A02B-48F4BD6F67D4",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "08C05889-826B-411F-AD6A-F18C432A3B1F",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux:*:*:*:*:*:*:*:*",
"matchCriteriaId": "225A5B49-7DB5-4B80-A560-5BEE65A7FC3D",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3E6DD82E-5047-4E7B-8C73-3BF8FD112F3A",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47A9B7EB-229C-4A23-9BB7-72A5ABD61279",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "43092C73-1302-4915-B2BC-59058FF61EFA",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B9392852-7BEF-402C-9ED4-2D7D40955311",
"versionEndExcluding": "3.5.12.80",
"versionStartIncluding": "3.5.8.60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FB77946F-7038-40FD-8204-B777ED0E59D2",
"versionEndExcluding": "3.5.14.10",
"versionStartIncluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F1CB113B-1207-43D9-A999-42B08AD50EB2",
"versionEndExcluding": "3.5.12.80",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE519838-FADF-43EA-9723-9283C0E18E85",
"versionEndIncluding": "3.5.12.80",
"versionStartIncluding": "3.5.9.80",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3466070E-1377-4272-AC73-717B9DEC144C",
"versionEndExcluding": "3.5.14.10",
"versionStartIncluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "07A7C9E7-ABF4-4C29-AF16-E697E35CFFC7",
"versionEndExcluding": "3.5.12.80",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BD2CDAC2-F8EB-45F4-82E2-5E5601F49D8A",
"versionEndExcluding": "3.5.12.80",
"versionStartIncluding": "3.5.10.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1AC3C628-281A-4E8E-ADE6-4CE976E187D4",
"versionEndExcluding": "3.5.14.10",
"versionStartIncluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "08230AB2-9EA0-4F98-8CE5-0A9ADB2B2334",
"versionEndExcluding": "3.5.12.80",
"versionStartIncluding": "3.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution."
},
{
"lang": "es",
"value": "El servidor web de CODESYS V3, todas las versiones anteriores a 3.5.14.10, permite a un atacante enviar peticiones http o https especialmente dise\u00f1adas que podr\u00edan causar un desbordamiento de la pila y crear una condici\u00f3n de denegaci\u00f3n de servicio o permitir la ejecuci\u00f3n de c\u00f3digo remota."
}
],
"id": "CVE-2019-13548",
"lastModified": "2026-06-17T02:16:57.440",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-09-13T17:15:11.693",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-01"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-13532
Vulnerability from fkie_nvd - Published: 2019-09-13 17:15 - Updated: 2026-06-17 02:16
Severity
Summary
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.us-cert.gov/ics/advisories/icsa-19-255-01 | Mitigation, Patch, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-255-01 | Mitigation, Patch, Third Party Advisory, US Government Resource |
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "CODESYS V3 web server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "all versions prior to 3.5.14.10"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BC95996F-4E60-4CCE-BC7D-2F998969455D",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CCE0D6F6-86D9-488A-A02B-48F4BD6F67D4",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "08C05889-826B-411F-AD6A-F18C432A3B1F",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_linux:*:*:*:*:*:*:*:*",
"matchCriteriaId": "225A5B49-7DB5-4B80-A560-5BEE65A7FC3D",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3E6DD82E-5047-4E7B-8C73-3BF8FD112F3A",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47A9B7EB-229C-4A23-9BB7-72A5ABD61279",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "43092C73-1302-4915-B2BC-59058FF61EFA",
"versionEndExcluding": "3.5.14.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B9392852-7BEF-402C-9ED4-2D7D40955311",
"versionEndExcluding": "3.5.12.80",
"versionStartIncluding": "3.5.8.60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FB77946F-7038-40FD-8204-B777ED0E59D2",
"versionEndExcluding": "3.5.14.10",
"versionStartIncluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F1CB113B-1207-43D9-A999-42B08AD50EB2",
"versionEndExcluding": "3.5.12.80",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE519838-FADF-43EA-9723-9283C0E18E85",
"versionEndIncluding": "3.5.12.80",
"versionStartIncluding": "3.5.9.80",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3466070E-1377-4272-AC73-717B9DEC144C",
"versionEndExcluding": "3.5.14.10",
"versionStartIncluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "07A7C9E7-ABF4-4C29-AF16-E697E35CFFC7",
"versionEndExcluding": "3.5.12.80",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BD2CDAC2-F8EB-45F4-82E2-5E5601F49D8A",
"versionEndExcluding": "3.5.12.80",
"versionStartIncluding": "3.5.10.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1AC3C628-281A-4E8E-ADE6-4CE976E187D4",
"versionEndExcluding": "3.5.14.10",
"versionStartIncluding": "3.5.13.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "08230AB2-9EA0-4F98-8CE5-0A9ADB2B2334",
"versionEndExcluding": "3.5.12.80",
"versionStartIncluding": "3.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller."
},
{
"lang": "es",
"value": "El servidor web de CODESYS V3, todas las versiones anteriores a 3.5.14.10, permite a un atacante enviar peticiones http o https especialmente dise\u00f1adas que pueden conceder el acceso a archivos fuera del directorio de trabajo restringido del controlador."
}
],
"id": "CVE-2019-13532",
"lastModified": "2026-06-17T02:16:55.407",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-09-13T17:15:11.617",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-255-01"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2018-25048
Vulnerability from fkie_nvd - Published: 2023-03-23 11:15 - Updated: 2026-06-17 01:54
Severity
Summary
The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Control for BeagleBone",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": " Control for emPC-A/iMX6",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for IOT2000",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for PFC100",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for PFC200",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control for Raspberry Pi",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control RTE V3 (all variants)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control Win V3 (all variants)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "V3 Simulation Runtime (part of the CODESYS Development System)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "HMI V3 (all variants)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "V3 Remote Target Visu (all variants)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Control V3 Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "V3 Embedded Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "V3 Remote Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.12.30",
"status": "affected",
"version": "3.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Runtime Toolkit 32 bit embedded",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "2.3.2.10",
"status": "affected",
"version": "2.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Runtime Toolkit 32 bit full",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "2.4.7.52",
"status": "affected",
"version": "2.0.0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Runtime PLCWinNT",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "2.4.7.52",
"status": "affected",
"version": "2.0.0.0",
"versionType": "custom"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:control_for_beaglebone:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B29080C3-A6D8-40D6-8C24-177C00FA27F0",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B980C936-557F-4F14-A692-165129625A62",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_iot2000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D282ECAB-FA07-4A81-8F43-AC46A08422D4",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc100:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AC1C508C-6817-42E7-9B4C-CDCAC7477304",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_pfc200:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1ECCA6D-3F95-4924-9CC6-7315B1608217",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "093C888E-8328-45E9-882C-39D7FBE8E251",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_rte:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4E767B6C-7762-4F3C-A8B0-BEC9C1C238D8",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_v3_runtime_system_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2DDCE092-30E5-43FB-A20F-A712DFD7B1C3",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:control_win:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A47EA342-7BDA-4707-9A23-142126C407C1",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A0FE0CC3-99BF-46BF-907D-E8F2785310BB",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*",
"matchCriteriaId": "157E617E-7432-464A-AEC4-29D3806FA2D2",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D95B012B-C9B0-4E2A-934B-3ECDE463722E",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:runtime_plcwinnt:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8931A117-72B6-4B1C-BF56-E7925D07A790",
"versionEndExcluding": "2.4.7.52",
"versionStartIncluding": "2.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:runtime_system_toolkit:*:*:*:*:*:*:x86:*",
"matchCriteriaId": "46335A20-A1BF-4E5B-BB1D-B7A4AFF6DB08",
"versionEndExcluding": "2.4.7.52",
"versionStartIncluding": "2.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:runtime_system_toolkit:3.5.15.0:*:*:*:*:*:*:*",
"matchCriteriaId": "7A3A8DFF-705F-4562-87CE-E899C5DC2D18",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:codesys:simulation_runtime:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9DD3AD40-BEE7-428D-B1F0-1349E10A9DD5",
"versionEndExcluding": "3.5.12.30",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device."
}
],
"id": "CVE-2018-25048",
"lastModified": "2026-06-17T01:54:36.137",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2018-25048",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-19T21:00:23.308028Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-03-23T11:15:12.730",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Not Applicable"
],
"url": "https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable"
],
"url": "https://customers.codesys.com/fileadmin/data/customers/security/2018/Advisory2018-04_CDS-59017.pdf"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}