Search
Find a vulnerability
Search criteria
12 vulnerabilities found for g36_firmware by tp-link
FKIE_CVE-2025-6542
Vulnerability from fkie_nvd - Published: 2025-10-21 01:15 - Updated: 2026-10-18 21:10
Severity
Summary
An arbitrary OS command may be executed on the product by a remote unauthenticated attacker.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | er8411_firmware | * | |
| tp-link | er8411_firmware | 1.3.3 | |
| tp-link | er8411 | - | |
| tp-link | er7412-m2_firmware | * | |
| tp-link | er7412-m2_firmware | 1.1.0 | |
| tp-link | er7412-m2 | - | |
| tp-link | er707-m2_firmware | * | |
| tp-link | er707-m2_firmware | 1.3.1 | |
| tp-link | er707-m2 | - | |
| tp-link | er7206_firmware | * | |
| tp-link | er7206_firmware | 2.2.2 | |
| tp-link | er7206 | - | |
| tp-link | er605_firmware | * | |
| tp-link | er605_firmware | 2.3.1 | |
| tp-link | er605 | - | |
| tp-link | er706w_firmware | * | |
| tp-link | er706w_firmware | 1.2.1 | |
| tp-link | er706w | - | |
| tp-link | er706w-4g_firmware | * | |
| tp-link | er706w-4g_firmware | 1.2.1 | |
| tp-link | er706w-4g | - | |
| tp-link | er7212pc_firmware | * | |
| tp-link | er7212pc_firmware | 2.1.3 | |
| tp-link | er7212pc | - | |
| tp-link | g36_firmware | * | |
| tp-link | g36_firmware | 1.1.4 | |
| tp-link | g36 | - | |
| tp-link | g611_firmware | * | |
| tp-link | g611_firmware | 1.2.2 | |
| tp-link | g611 | - | |
| tp-link | fr365_firmware | * | |
| tp-link | fr365_firmware | 1.1.10 | |
| tp-link | fr365 | - | |
| tp-link | fr205_firmware | * | |
| tp-link | fr205_firmware | 1.0.3 | |
| tp-link | fr205 | - | |
| tp-link | fr307-m2_firmware | * | |
| tp-link | fr307-m2_firmware | 1.2.5 | |
| tp-link | fr307-m2 | - |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE0D8327-33EE-4EF0-BC2F-F2A16D55762A",
"versionEndExcluding": "1.3.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:1.3.3:-:*:*:*:*:*:*",
"matchCriteriaId": "6DB13EF6-0930-4575-92DC-AF431B2A2CEF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14CE8275-E546-4598-901C-F52355DED3C9",
"versionEndExcluding": "1.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:1.1.0:-:*:*:*:*:*:*",
"matchCriteriaId": "B79E0763-6D6F-4E59-91FC-D397A8BEF0F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48EDBC5B-BA54-4D11-9391-4FA7C7D4F5E7",
"versionEndExcluding": "1.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:1.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "359ADA2C-F1A5-4840-8F84-2DBA8F4573C4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF595A8A-72CF-406E-BB0C-B76FDD51150B",
"versionEndExcluding": "2.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:2.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "8F66B05E-0D03-4B59-BCA3-7A2F40F092EE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB65324D-FD72-4C28-92AF-85BFF1E8A993",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8EA51B29-39FB-4880-979B-3F612DE9D202",
"versionEndExcluding": "2.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:2.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "1D1D1C14-E0F9-430D-BAC5-4F0C7287FD26",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9892BC7C-6EA7-469B-AD26-6E5093DB5AB2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47273FE0-6E22-437E-B27F-058456E7602A",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "AC30DFD7-30FD-482C-B8EF-9DDB98E269BF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E1BC6D9F-A556-468A-8770-6A39F09F26D6",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "96944BD2-388F-4CF6-BFD3-473EE6624F74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6CE877B8-E287-4FE6-84D5-666FE27AC9A6",
"versionEndExcluding": "2.1.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:2.1.3:-:*:*:*:*:*:*",
"matchCriteriaId": "24860FF1-7CA9-47D4-90B6-CB8915F1D992",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F300A161-E1A3-469E-9DE3-9B052F6BA8AC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EB884461-7A80-44B0-A200-25D7E0EB5152",
"versionEndExcluding": "1.1.4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:1.1.4:-:*:*:*:*:*:*",
"matchCriteriaId": "BDA7D066-8443-4D6F-8E22-A0845236B490",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g36:-:*:*:*:*:*:*:*",
"matchCriteriaId": "153073B7-9FBD-47D0-A1AB-CEE323AE5512",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E6F8E98F-0C86-40C0-BBD3-D2B1889BAA87",
"versionEndExcluding": "1.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:1.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "5FF584E3-70F0-4B05-857B-CE07D87BA130",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g611:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D4BA74E1-BDA0-4FDD-820A-8DE32EEE2AA7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D38B9DBD-3397-40B8-B4A5-C1E0C248C300",
"versionEndExcluding": "1.1.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:1.1.10:-:*:*:*:*:*:*",
"matchCriteriaId": "4DA30139-EBED-40FD-BA20-CED14607B648",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr365:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFB3D95C-C64A-48A6-8D13-E158CFB3CC7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7FC1549-BC5C-45CF-8524-6DFFB4193D1B",
"versionEndExcluding": "1.0.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:1.0.3:-:*:*:*:*:*:*",
"matchCriteriaId": "532C5C8D-3AC4-4596-8D8C-6855686BD92A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr205:-:*:*:*:*:*:*:*",
"matchCriteriaId": "56799602-9EF3-47D5-86CC-9AA2AE3013CF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6952617F-CF3F-4EB4-89B3-0C7076EEEEBC",
"versionEndExcluding": "1.2.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:1.2.5:-:*:*:*:*:*:*",
"matchCriteriaId": "5FDFE511-0244-454D-8D3F-C7E46D499FC5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr307-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2559CDDD-2C81-49A8-BF42-B3F6AC68F5F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An arbitrary OS command may be executed on the product by a remote unauthenticated attacker."
},
{
"lang": "es",
"value": "Un comando arbitrario del SO puede ser ejecutado en el producto por un atacante remoto no autenticado."
}
],
"id": "CVE-2025-6542",
"lastModified": "2026-10-18T21:10:00.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-6542",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:14:50.370895Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-10-21T01:15:37.063",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://support.omadanetworks.com/en/document/108455/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-7851
Vulnerability from fkie_nvd - Published: 2025-10-21 01:15 - Updated: 2026-10-18 21:10
Severity
Summary
An attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | fr307-m2_firmware | * | |
| tp-link | fr307-m2_firmware | 1.2.5 | |
| tp-link | fr307-m2 | - | |
| tp-link | fr205_firmware | * | |
| tp-link | fr205_firmware | 1.0.3 | |
| tp-link | fr205 | - | |
| tp-link | fr365_firmware | * | |
| tp-link | fr365_firmware | 1.1.10 | |
| tp-link | fr365 | - | |
| tp-link | g611_firmware | * | |
| tp-link | g611_firmware | 1.2.2 | |
| tp-link | g611 | - | |
| tp-link | g36_firmware | * | |
| tp-link | g36_firmware | 1.1.4 | |
| tp-link | g36 | - | |
| tp-link | er7212pc_firmware | * | |
| tp-link | er7212pc_firmware | 2.1.3 | |
| tp-link | er7212pc | - | |
| tp-link | er706w-4g_firmware | * | |
| tp-link | er706w-4g_firmware | 1.2.1 | |
| tp-link | er706w-4g | - | |
| tp-link | er706w_firmware | * | |
| tp-link | er706w_firmware | 1.2.1 | |
| tp-link | er706w | - | |
| tp-link | er605_firmware | * | |
| tp-link | er605_firmware | 2.3.1 | |
| tp-link | er605 | - | |
| tp-link | er7206_firmware | * | |
| tp-link | er7206_firmware | 2.2.2 | |
| tp-link | er7206 | - | |
| tp-link | er707-m2_firmware | * | |
| tp-link | er707-m2_firmware | 1.3.1 | |
| tp-link | er707-m2 | - | |
| tp-link | er7412-m2_firmware | * | |
| tp-link | er7412-m2_firmware | 1.1.0 | |
| tp-link | er7412-m2 | - | |
| tp-link | er8411_firmware | * | |
| tp-link | er8411_firmware | 1.3.3 | |
| tp-link | er8411 | - |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6952617F-CF3F-4EB4-89B3-0C7076EEEEBC",
"versionEndExcluding": "1.2.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:1.2.5:-:*:*:*:*:*:*",
"matchCriteriaId": "5FDFE511-0244-454D-8D3F-C7E46D499FC5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr307-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2559CDDD-2C81-49A8-BF42-B3F6AC68F5F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7FC1549-BC5C-45CF-8524-6DFFB4193D1B",
"versionEndExcluding": "1.0.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:1.0.3:-:*:*:*:*:*:*",
"matchCriteriaId": "532C5C8D-3AC4-4596-8D8C-6855686BD92A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr205:-:*:*:*:*:*:*:*",
"matchCriteriaId": "56799602-9EF3-47D5-86CC-9AA2AE3013CF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D38B9DBD-3397-40B8-B4A5-C1E0C248C300",
"versionEndExcluding": "1.1.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:1.1.10:-:*:*:*:*:*:*",
"matchCriteriaId": "4DA30139-EBED-40FD-BA20-CED14607B648",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr365:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFB3D95C-C64A-48A6-8D13-E158CFB3CC7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E6F8E98F-0C86-40C0-BBD3-D2B1889BAA87",
"versionEndExcluding": "1.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:1.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "5FF584E3-70F0-4B05-857B-CE07D87BA130",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g611:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D4BA74E1-BDA0-4FDD-820A-8DE32EEE2AA7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EB884461-7A80-44B0-A200-25D7E0EB5152",
"versionEndExcluding": "1.1.4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:1.1.4:-:*:*:*:*:*:*",
"matchCriteriaId": "BDA7D066-8443-4D6F-8E22-A0845236B490",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g36:-:*:*:*:*:*:*:*",
"matchCriteriaId": "153073B7-9FBD-47D0-A1AB-CEE323AE5512",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6CE877B8-E287-4FE6-84D5-666FE27AC9A6",
"versionEndExcluding": "2.1.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:2.1.3:-:*:*:*:*:*:*",
"matchCriteriaId": "24860FF1-7CA9-47D4-90B6-CB8915F1D992",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F300A161-E1A3-469E-9DE3-9B052F6BA8AC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E1BC6D9F-A556-468A-8770-6A39F09F26D6",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "96944BD2-388F-4CF6-BFD3-473EE6624F74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47273FE0-6E22-437E-B27F-058456E7602A",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "AC30DFD7-30FD-482C-B8EF-9DDB98E269BF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8EA51B29-39FB-4880-979B-3F612DE9D202",
"versionEndExcluding": "2.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:2.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "1D1D1C14-E0F9-430D-BAC5-4F0C7287FD26",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9892BC7C-6EA7-469B-AD26-6E5093DB5AB2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF595A8A-72CF-406E-BB0C-B76FDD51150B",
"versionEndExcluding": "2.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:2.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "8F66B05E-0D03-4B59-BCA3-7A2F40F092EE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB65324D-FD72-4C28-92AF-85BFF1E8A993",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48EDBC5B-BA54-4D11-9391-4FA7C7D4F5E7",
"versionEndExcluding": "1.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:1.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "359ADA2C-F1A5-4840-8F84-2DBA8F4573C4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14CE8275-E546-4598-901C-F52355DED3C9",
"versionEndExcluding": "1.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:1.1.0:-:*:*:*:*:*:*",
"matchCriteriaId": "B79E0763-6D6F-4E59-91FC-D397A8BEF0F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE0D8327-33EE-4EF0-BC2F-F2A16D55762A",
"versionEndExcluding": "1.3.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:1.3.3:-:*:*:*:*:*:*",
"matchCriteriaId": "6DB13EF6-0930-4575-92DC-AF431B2A2CEF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways."
},
{
"lang": "es",
"value": "Un atacante puede obtener el shell de root en el sistema operativo subyacente con las condiciones restringidas en los gateways Omada."
}
],
"id": "CVE-2025-7851",
"lastModified": "2026-10-18T21:10:00.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-7851",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:07:19.825502Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-10-21T01:15:37.330",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://support.omadanetworks.com/en/document/108456/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"url": "https://www.forescout.com/blog/new-tp-link-router-vulnerabilities-a-primer-on-rooting-routers/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-6541
Vulnerability from fkie_nvd - Published: 2025-10-21 01:15 - Updated: 2026-10-18 21:10
Severity
Summary
An arbitrary OS command may be executed on the product by the user who can log in to the web management interface.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | er706w_firmware | * | |
| tp-link | er706w_firmware | 1.2.1 | |
| tp-link | er706w | - | |
| tp-link | er706w-4g_firmware | * | |
| tp-link | er706w-4g_firmware | 1.2.1 | |
| tp-link | er706w-4g | - | |
| tp-link | er7212pc_firmware | * | |
| tp-link | er7212pc_firmware | 2.1.3 | |
| tp-link | er7212pc | - | |
| tp-link | g36_firmware | * | |
| tp-link | g36_firmware | 1.1.4 | |
| tp-link | g36 | - | |
| tp-link | g611_firmware | * | |
| tp-link | g611_firmware | 1.2.2 | |
| tp-link | g611 | - | |
| tp-link | fr365_firmware | * | |
| tp-link | fr365_firmware | 1.1.10 | |
| tp-link | fr365 | - | |
| tp-link | fr205_firmware | * | |
| tp-link | fr205_firmware | 1.0.3 | |
| tp-link | fr205 | - | |
| tp-link | fr307-m2_firmware | * | |
| tp-link | fr307-m2_firmware | 1.2.5 | |
| tp-link | fr307-m2 | - | |
| tp-link | er8411_firmware | * | |
| tp-link | er8411_firmware | 1.3.3 | |
| tp-link | er8411 | - | |
| tp-link | er7412-m2_firmware | * | |
| tp-link | er7412-m2_firmware | 1.1.0 | |
| tp-link | er7412-m2 | - | |
| tp-link | er707-m2_firmware | * | |
| tp-link | er707-m2_firmware | 1.3.1 | |
| tp-link | er707-m2 | - | |
| tp-link | er7206_firmware | * | |
| tp-link | er7206_firmware | 2.2.2 | |
| tp-link | er7206 | - | |
| tp-link | er605_firmware | * | |
| tp-link | er605_firmware | 2.3.1 | |
| tp-link | er605 | - |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47273FE0-6E22-437E-B27F-058456E7602A",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "AC30DFD7-30FD-482C-B8EF-9DDB98E269BF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E1BC6D9F-A556-468A-8770-6A39F09F26D6",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "96944BD2-388F-4CF6-BFD3-473EE6624F74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6CE877B8-E287-4FE6-84D5-666FE27AC9A6",
"versionEndExcluding": "2.1.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:2.1.3:-:*:*:*:*:*:*",
"matchCriteriaId": "24860FF1-7CA9-47D4-90B6-CB8915F1D992",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F300A161-E1A3-469E-9DE3-9B052F6BA8AC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EB884461-7A80-44B0-A200-25D7E0EB5152",
"versionEndExcluding": "1.1.4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:1.1.4:-:*:*:*:*:*:*",
"matchCriteriaId": "BDA7D066-8443-4D6F-8E22-A0845236B490",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g36:-:*:*:*:*:*:*:*",
"matchCriteriaId": "153073B7-9FBD-47D0-A1AB-CEE323AE5512",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E6F8E98F-0C86-40C0-BBD3-D2B1889BAA87",
"versionEndExcluding": "1.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:1.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "5FF584E3-70F0-4B05-857B-CE07D87BA130",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g611:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D4BA74E1-BDA0-4FDD-820A-8DE32EEE2AA7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D38B9DBD-3397-40B8-B4A5-C1E0C248C300",
"versionEndExcluding": "1.1.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:1.1.10:-:*:*:*:*:*:*",
"matchCriteriaId": "4DA30139-EBED-40FD-BA20-CED14607B648",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr365:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFB3D95C-C64A-48A6-8D13-E158CFB3CC7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7FC1549-BC5C-45CF-8524-6DFFB4193D1B",
"versionEndExcluding": "1.0.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:1.0.3:-:*:*:*:*:*:*",
"matchCriteriaId": "532C5C8D-3AC4-4596-8D8C-6855686BD92A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr205:-:*:*:*:*:*:*:*",
"matchCriteriaId": "56799602-9EF3-47D5-86CC-9AA2AE3013CF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6952617F-CF3F-4EB4-89B3-0C7076EEEEBC",
"versionEndExcluding": "1.2.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:1.2.5:-:*:*:*:*:*:*",
"matchCriteriaId": "5FDFE511-0244-454D-8D3F-C7E46D499FC5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr307-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2559CDDD-2C81-49A8-BF42-B3F6AC68F5F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE0D8327-33EE-4EF0-BC2F-F2A16D55762A",
"versionEndExcluding": "1.3.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:1.3.3:-:*:*:*:*:*:*",
"matchCriteriaId": "6DB13EF6-0930-4575-92DC-AF431B2A2CEF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14CE8275-E546-4598-901C-F52355DED3C9",
"versionEndExcluding": "1.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:1.1.0:-:*:*:*:*:*:*",
"matchCriteriaId": "B79E0763-6D6F-4E59-91FC-D397A8BEF0F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48EDBC5B-BA54-4D11-9391-4FA7C7D4F5E7",
"versionEndExcluding": "1.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:1.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "359ADA2C-F1A5-4840-8F84-2DBA8F4573C4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF595A8A-72CF-406E-BB0C-B76FDD51150B",
"versionEndExcluding": "2.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:2.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "8F66B05E-0D03-4B59-BCA3-7A2F40F092EE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB65324D-FD72-4C28-92AF-85BFF1E8A993",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8EA51B29-39FB-4880-979B-3F612DE9D202",
"versionEndExcluding": "2.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:2.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "1D1D1C14-E0F9-430D-BAC5-4F0C7287FD26",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9892BC7C-6EA7-469B-AD26-6E5093DB5AB2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An arbitrary OS command may be executed on the product by the user who can log in to the web management interface."
},
{
"lang": "es",
"value": "Un comando arbitrario del sistema operativo puede ser ejecutado en el producto por el usuario que puede iniciar sesi\u00f3n en la interfaz de gesti\u00f3n web."
}
],
"id": "CVE-2025-6541",
"lastModified": "2026-10-18T21:10:00.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-6541",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T13:56:36.534414Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-10-21T01:15:36.103",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://support.omadanetworks.com/en/document/108455/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-7850
Vulnerability from fkie_nvd - Published: 2025-10-21 01:15 - Updated: 2026-10-18 21:10
Severity
Summary
A command injection vulnerability may be exploited after the admin's authentication on the web portal on Omada gateways.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | er8411_firmware | * | |
| tp-link | er8411_firmware | 1.3.3 | |
| tp-link | er8411 | - | |
| tp-link | er7412-m2_firmware | * | |
| tp-link | er7412-m2_firmware | 1.1.0 | |
| tp-link | er7412-m2 | - | |
| tp-link | er707-m2_firmware | * | |
| tp-link | er707-m2_firmware | 1.3.1 | |
| tp-link | er707-m2 | - | |
| tp-link | er7206_firmware | * | |
| tp-link | er7206_firmware | 2.2.2 | |
| tp-link | er7206 | - | |
| tp-link | er605_firmware | * | |
| tp-link | er605_firmware | 2.3.1 | |
| tp-link | er605 | - | |
| tp-link | er706w_firmware | * | |
| tp-link | er706w_firmware | 1.2.1 | |
| tp-link | er706w | - | |
| tp-link | er706w-4g_firmware | * | |
| tp-link | er706w-4g_firmware | 1.2.1 | |
| tp-link | er706w-4g | - | |
| tp-link | er7212pc_firmware | * | |
| tp-link | er7212pc_firmware | 2.1.3 | |
| tp-link | er7212pc | - | |
| tp-link | g36_firmware | * | |
| tp-link | g36_firmware | 1.1.4 | |
| tp-link | g36 | - | |
| tp-link | g611_firmware | * | |
| tp-link | g611_firmware | 1.2.2 | |
| tp-link | g611 | - | |
| tp-link | fr365_firmware | * | |
| tp-link | fr365_firmware | 1.1.10 | |
| tp-link | fr365 | - | |
| tp-link | fr205_firmware | * | |
| tp-link | fr205_firmware | 1.0.3 | |
| tp-link | fr205 | - | |
| tp-link | fr307-m2_firmware | * | |
| tp-link | fr307-m2_firmware | 1.2.5 | |
| tp-link | fr307-m2 | - |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE0D8327-33EE-4EF0-BC2F-F2A16D55762A",
"versionEndExcluding": "1.3.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:1.3.3:-:*:*:*:*:*:*",
"matchCriteriaId": "6DB13EF6-0930-4575-92DC-AF431B2A2CEF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14CE8275-E546-4598-901C-F52355DED3C9",
"versionEndExcluding": "1.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:1.1.0:-:*:*:*:*:*:*",
"matchCriteriaId": "B79E0763-6D6F-4E59-91FC-D397A8BEF0F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48EDBC5B-BA54-4D11-9391-4FA7C7D4F5E7",
"versionEndExcluding": "1.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:1.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "359ADA2C-F1A5-4840-8F84-2DBA8F4573C4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF595A8A-72CF-406E-BB0C-B76FDD51150B",
"versionEndExcluding": "2.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:2.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "8F66B05E-0D03-4B59-BCA3-7A2F40F092EE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB65324D-FD72-4C28-92AF-85BFF1E8A993",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8EA51B29-39FB-4880-979B-3F612DE9D202",
"versionEndExcluding": "2.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:2.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "1D1D1C14-E0F9-430D-BAC5-4F0C7287FD26",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9892BC7C-6EA7-469B-AD26-6E5093DB5AB2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47273FE0-6E22-437E-B27F-058456E7602A",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "AC30DFD7-30FD-482C-B8EF-9DDB98E269BF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E1BC6D9F-A556-468A-8770-6A39F09F26D6",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "96944BD2-388F-4CF6-BFD3-473EE6624F74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6CE877B8-E287-4FE6-84D5-666FE27AC9A6",
"versionEndExcluding": "2.1.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:2.1.3:-:*:*:*:*:*:*",
"matchCriteriaId": "24860FF1-7CA9-47D4-90B6-CB8915F1D992",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F300A161-E1A3-469E-9DE3-9B052F6BA8AC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EB884461-7A80-44B0-A200-25D7E0EB5152",
"versionEndExcluding": "1.1.4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:1.1.4:-:*:*:*:*:*:*",
"matchCriteriaId": "BDA7D066-8443-4D6F-8E22-A0845236B490",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g36:-:*:*:*:*:*:*:*",
"matchCriteriaId": "153073B7-9FBD-47D0-A1AB-CEE323AE5512",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E6F8E98F-0C86-40C0-BBD3-D2B1889BAA87",
"versionEndExcluding": "1.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:1.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "5FF584E3-70F0-4B05-857B-CE07D87BA130",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g611:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D4BA74E1-BDA0-4FDD-820A-8DE32EEE2AA7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D38B9DBD-3397-40B8-B4A5-C1E0C248C300",
"versionEndExcluding": "1.1.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:1.1.10:-:*:*:*:*:*:*",
"matchCriteriaId": "4DA30139-EBED-40FD-BA20-CED14607B648",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr365:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFB3D95C-C64A-48A6-8D13-E158CFB3CC7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7FC1549-BC5C-45CF-8524-6DFFB4193D1B",
"versionEndExcluding": "1.0.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:1.0.3:-:*:*:*:*:*:*",
"matchCriteriaId": "532C5C8D-3AC4-4596-8D8C-6855686BD92A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr205:-:*:*:*:*:*:*:*",
"matchCriteriaId": "56799602-9EF3-47D5-86CC-9AA2AE3013CF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6952617F-CF3F-4EB4-89B3-0C7076EEEEBC",
"versionEndExcluding": "1.2.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:1.2.5:-:*:*:*:*:*:*",
"matchCriteriaId": "5FDFE511-0244-454D-8D3F-C7E46D499FC5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr307-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2559CDDD-2C81-49A8-BF42-B3F6AC68F5F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A command injection vulnerability may be exploited after the admin\u0027s authentication on the web portal on Omada gateways."
},
{
"lang": "es",
"value": "Una vulnerabilidad de inyecci\u00f3n de comandos puede ser explotada despu\u00e9s de la autenticaci\u00f3n del administrador en el portal web en los gateways Omada."
}
],
"id": "CVE-2025-7850",
"lastModified": "2026-10-18T21:10:00.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-7850",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:09:38.276316Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-10-21T01:15:37.193",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://support.omadanetworks.com/en/document/108456/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"url": "https://www.forescout.com/blog/new-tp-link-router-vulnerabilities-a-primer-on-rooting-routers/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
]
}
CVE-2025-7851 (GCVE-0-2025-7851)
Vulnerability from nvd – Published: 2025-10-21 00:29 – Updated: 2025-10-24 17:00
VLAI
EPSS
VEX
Title
Unauthorized root access via debug functionality
Summary
An attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 14:07 UTC
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
5 references
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7851",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:07:19.825502Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:07:59.499Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Stanislav Dashevskyi and Francesco La Spina of Forescout"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eAn attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "An attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-24T17:00:06.753Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108456/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
},
{
"url": "https://www.forescout.com/blog/new-tp-link-router-vulnerabilities-a-primer-on-rooting-routers/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthorized root access via debug functionality",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-7851",
"datePublished": "2025-10-21T00:29:05.809Z",
"dateReserved": "2025-07-18T21:49:12.159Z",
"dateUpdated": "2025-10-24T17:00:06.753Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7850 (GCVE-0-2025-7850)
Vulnerability from nvd – Published: 2025-10-21 00:28 – Updated: 2025-10-24 16:59
VLAI
EPSS
VEX
Title
Authenticated OS command execution
Summary
A command injection vulnerability may be exploited after the admin's authentication on the web portal on Omada gateways.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 14:09 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
5 references
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7850",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:09:38.276316Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:10:11.876Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Stanislav Dashevskyi and Francesco La Spina of Forescout"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eA command injection vulnerability may be exploited after the admin\u0027s authentication on the web portal on Omada gateways.\u003cbr\u003e\u003c/div\u003e"
}
],
"value": "A command injection vulnerability may be exploited after the admin\u0027s authentication on the web portal on Omada gateways."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-24T16:59:25.310Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108456/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
},
{
"url": "https://www.forescout.com/blog/new-tp-link-router-vulnerabilities-a-primer-on-rooting-routers/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authenticated OS command execution",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-7850",
"datePublished": "2025-10-21T00:28:11.589Z",
"dateReserved": "2025-07-18T21:49:10.486Z",
"dateUpdated": "2025-10-24T16:59:25.310Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6542 (GCVE-0-2025-6542)
Vulnerability from nvd – Published: 2025-10-21 00:23 – Updated: 2025-10-21 14:15
VLAI
EPSS
VEX
Title
OS command injection in multiple parameters
Summary
An arbitrary OS command may be executed on the product by a remote unauthenticated attacker.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 14:14 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://support.omadanetworks.com/en/document/108455/ | vendor-advisory |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.tp-link.com/us/business-networking/so… | product |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6542",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:14:50.370895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:15:13.774Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An arbitrary OS command may be executed on the product by a remote unauthenticated attacker."
}
],
"value": "An arbitrary OS command may be executed on the product by a remote unauthenticated attacker."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T01:16:09.887Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108455/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "OS command injection in multiple parameters",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-6542",
"datePublished": "2025-10-21T00:23:08.908Z",
"dateReserved": "2025-06-23T17:48:10.419Z",
"dateUpdated": "2025-10-21T14:15:13.774Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6541 (GCVE-0-2025-6541)
Vulnerability from nvd – Published: 2025-10-21 00:21 – Updated: 2025-10-21 13:57
VLAI
EPSS
VEX
Title
OS command injection using information obtained from the web management interface
Summary
An arbitrary OS command may be executed on the product by the user who can log in to the web management interface.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 13:56 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://support.omadanetworks.com/en/document/108455/ | vendor-advisory |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.tp-link.com/us/business-networking/so… | product |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6541",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T13:56:36.534414Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T13:57:51.728Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An arbitrary OS command may be executed on the product by the user who can log in to the web management interface."
}
],
"value": "An arbitrary OS command may be executed on the product by the user who can log in to the web management interface."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T00:21:42.535Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108455/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "OS command injection using information obtained from the web management interface",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-6541",
"datePublished": "2025-10-21T00:21:42.535Z",
"dateReserved": "2025-06-23T17:48:07.425Z",
"dateUpdated": "2025-10-21T13:57:51.728Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7851 (GCVE-0-2025-7851)
Vulnerability from cvelistv5 – Published: 2025-10-21 00:29 – Updated: 2025-10-24 17:00
VLAI
EPSS
VEX
Title
Unauthorized root access via debug functionality
Summary
An attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 14:07 UTC
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
5 references
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7851",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:07:19.825502Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:07:59.499Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Stanislav Dashevskyi and Francesco La Spina of Forescout"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eAn attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "An attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-24T17:00:06.753Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108456/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
},
{
"url": "https://www.forescout.com/blog/new-tp-link-router-vulnerabilities-a-primer-on-rooting-routers/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthorized root access via debug functionality",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-7851",
"datePublished": "2025-10-21T00:29:05.809Z",
"dateReserved": "2025-07-18T21:49:12.159Z",
"dateUpdated": "2025-10-24T17:00:06.753Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7850 (GCVE-0-2025-7850)
Vulnerability from cvelistv5 – Published: 2025-10-21 00:28 – Updated: 2025-10-24 16:59
VLAI
EPSS
VEX
Title
Authenticated OS command execution
Summary
A command injection vulnerability may be exploited after the admin's authentication on the web portal on Omada gateways.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 14:09 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
5 references
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7850",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:09:38.276316Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:10:11.876Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Stanislav Dashevskyi and Francesco La Spina of Forescout"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eA command injection vulnerability may be exploited after the admin\u0027s authentication on the web portal on Omada gateways.\u003cbr\u003e\u003c/div\u003e"
}
],
"value": "A command injection vulnerability may be exploited after the admin\u0027s authentication on the web portal on Omada gateways."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-24T16:59:25.310Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108456/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
},
{
"url": "https://www.forescout.com/blog/new-tp-link-router-vulnerabilities-a-primer-on-rooting-routers/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authenticated OS command execution",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-7850",
"datePublished": "2025-10-21T00:28:11.589Z",
"dateReserved": "2025-07-18T21:49:10.486Z",
"dateUpdated": "2025-10-24T16:59:25.310Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6542 (GCVE-0-2025-6542)
Vulnerability from cvelistv5 – Published: 2025-10-21 00:23 – Updated: 2025-10-21 14:15
VLAI
EPSS
VEX
Title
OS command injection in multiple parameters
Summary
An arbitrary OS command may be executed on the product by a remote unauthenticated attacker.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 14:14 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://support.omadanetworks.com/en/document/108455/ | vendor-advisory |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.tp-link.com/us/business-networking/so… | product |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6542",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:14:50.370895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:15:13.774Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An arbitrary OS command may be executed on the product by a remote unauthenticated attacker."
}
],
"value": "An arbitrary OS command may be executed on the product by a remote unauthenticated attacker."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T01:16:09.887Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108455/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "OS command injection in multiple parameters",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-6542",
"datePublished": "2025-10-21T00:23:08.908Z",
"dateReserved": "2025-06-23T17:48:10.419Z",
"dateUpdated": "2025-10-21T14:15:13.774Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6541 (GCVE-0-2025-6541)
Vulnerability from cvelistv5 – Published: 2025-10-21 00:21 – Updated: 2025-10-21 13:57
VLAI
EPSS
VEX
Title
OS command injection using information obtained from the web management interface
Summary
An arbitrary OS command may be executed on the product by the user who can log in to the web management interface.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 13:56 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://support.omadanetworks.com/en/document/108455/ | vendor-advisory |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.tp-link.com/us/business-networking/so… | product |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6541",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T13:56:36.534414Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T13:57:51.728Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An arbitrary OS command may be executed on the product by the user who can log in to the web management interface."
}
],
"value": "An arbitrary OS command may be executed on the product by the user who can log in to the web management interface."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T00:21:42.535Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108455/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "OS command injection using information obtained from the web management interface",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-6541",
"datePublished": "2025-10-21T00:21:42.535Z",
"dateReserved": "2025-06-23T17:48:07.425Z",
"dateUpdated": "2025-10-21T13:57:51.728Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}