    CVE-2018-14802 (GCVE-0-2018-14802)

    Vulnerability from nvd – Published: 2018-10-01 13:00 – Updated: 2024-09-16 19:47
    VLAI
    Summary
    Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly check user-supplied comments which may allow for arbitrary remote code execution.
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
    Assigner
    References
    Date Public
    2018-09-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.971Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "105408",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/105408"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "v3.3 v7.3.4.1a"
                }
              ]
            }
          ],
          "datePublic": "2018-09-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly check user-supplied comments which may allow for arbitrary remote code execution."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-02T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "105408",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/105408"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-09-27T00:00:00",
              "ID": "CVE-2018-14802",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "v3.3 v7.3.4.1a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly check user-supplied comments which may allow for arbitrary remote code execution."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "105408",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/105408"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-14802",
        "datePublished": "2018-10-01T13:00:00.000Z",
        "dateReserved": "2018-08-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T19:47:13.278Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14798 (GCVE-0-2018-14798)

    Vulnerability from nvd – Published: 2018-10-01 13:00 – Updated: 2024-09-16 23:41
    VLAI
    Summary
    Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly parse FNC files that may allow for information disclosure.
    Severity
    No CVSS data available.
    CWE
    • CWE-125 - OUT-OF-BOUNDS READ CWE-125
    Assigner
    References
    Date Public
    2018-09-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.975Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "105408",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/105408"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "v3.3 v7.3.4.1a"
                }
              ]
            }
          ],
          "datePublic": "2018-09-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly parse FNC files that may allow for information disclosure."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "OUT-OF-BOUNDS READ CWE-125",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-02T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "105408",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/105408"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-09-27T00:00:00",
              "ID": "CVE-2018-14798",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "v3.3 v7.3.4.1a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly parse FNC files that may allow for information disclosure."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "OUT-OF-BOUNDS READ CWE-125"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "105408",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/105408"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-14798",
        "datePublished": "2018-10-01T13:00:00.000Z",
        "dateReserved": "2018-08-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:41:07.456Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14790 (GCVE-0-2018-14790)

    Vulnerability from nvd – Published: 2018-10-01 13:00 – Updated: 2024-09-17 03:32
    VLAI
    Summary
    Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device.
    Severity
    No CVSS data available.
    CWE
    • CWE-126 - BUFFER OVER-READ CWE-126
    Assigner
    References
    Date Public
    2018-09-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.951Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "105408",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/105408"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "v3.3 v7.3.4.1a"
                }
              ]
            }
          ],
          "datePublic": "2018-09-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-126",
                  "description": "BUFFER OVER-READ CWE-126",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-02T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "105408",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/105408"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-09-27T00:00:00",
              "ID": "CVE-2018-14790",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "v3.3 v7.3.4.1a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "BUFFER OVER-READ CWE-126"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "105408",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/105408"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-14790",
        "datePublished": "2018-10-01T13:00:00.000Z",
        "dateReserved": "2018-08-01T00:00:00.000Z",
        "dateUpdated": "2024-09-17T03:32:22.942Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14790 (GCVE-0-2018-14790)

    Vulnerability from cvelistv5 – Published: 2018-10-01 13:00 – Updated: 2024-09-17 03:32
    VLAI
    Summary
    Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device.
    Severity
    No CVSS data available.
    CWE
    • CWE-126 - BUFFER OVER-READ CWE-126
    Assigner
    References
    Date Public
    2018-09-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.951Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "105408",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/105408"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "v3.3 v7.3.4.1a"
                }
              ]
            }
          ],
          "datePublic": "2018-09-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-126",
                  "description": "BUFFER OVER-READ CWE-126",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-02T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "105408",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/105408"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-09-27T00:00:00",
              "ID": "CVE-2018-14790",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "v3.3 v7.3.4.1a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "BUFFER OVER-READ CWE-126"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "105408",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/105408"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-14790",
        "datePublished": "2018-10-01T13:00:00.000Z",
        "dateReserved": "2018-08-01T00:00:00.000Z",
        "dateUpdated": "2024-09-17T03:32:22.942Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14802 (GCVE-0-2018-14802)

    Vulnerability from cvelistv5 – Published: 2018-10-01 13:00 – Updated: 2024-09-16 19:47
    VLAI
    Summary
    Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly check user-supplied comments which may allow for arbitrary remote code execution.
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
    Assigner
    References
    Date Public
    2018-09-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.971Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "105408",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/105408"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "v3.3 v7.3.4.1a"
                }
              ]
            }
          ],
          "datePublic": "2018-09-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly check user-supplied comments which may allow for arbitrary remote code execution."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-02T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "105408",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/105408"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-09-27T00:00:00",
              "ID": "CVE-2018-14802",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "v3.3 v7.3.4.1a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly check user-supplied comments which may allow for arbitrary remote code execution."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "105408",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/105408"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-14802",
        "datePublished": "2018-10-01T13:00:00.000Z",
        "dateReserved": "2018-08-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T19:47:13.278Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14798 (GCVE-0-2018-14798)

    Vulnerability from cvelistv5 – Published: 2018-10-01 13:00 – Updated: 2024-09-16 23:41
    VLAI
    Summary
    Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly parse FNC files that may allow for information disclosure.
    Severity
    No CVSS data available.
    CWE
    • CWE-125 - OUT-OF-BOUNDS READ CWE-125
    Assigner
    References
    Date Public
    2018-09-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.975Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "105408",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/105408"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
              "vendor": "Fuji Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "v3.3 v7.3.4.1a"
                }
              ]
            }
          ],
          "datePublic": "2018-09-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly parse FNC files that may allow for information disclosure."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "OUT-OF-BOUNDS READ CWE-125",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-02T09:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "name": "105408",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/105408"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-09-27T00:00:00",
              "ID": "CVE-2018-14798",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "FRENIC LOADER of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "v3.3 v7.3.4.1a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Fuji Electric"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly parse FNC files that may allow for information disclosure."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "OUT-OF-BOUNDS READ CWE-125"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "105408",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/105408"
                },
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-270-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-14798",
        "datePublished": "2018-10-01T13:00:00.000Z",
        "dateReserved": "2018-08-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T23:41:07.456Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }