    FKIE_CVE-2026-27772

    Vulnerability from fkie_nvd - Published: 2026-02-27 00:16 - Updated: 2026-06-17 10:27
    Summary
    WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend.
    Impacted products
    Vendor Product Version
    ev.energy ev.energy *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "ev.energy",
              "vendor": "EV Energy",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:ev.energy:ev.energy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6F8630FC-2F5D-4362-8AD7-F2A2A73A20F2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "WebSocket endpoints lack proper authentication mechanisms, enabling \nattackers to perform unauthorized station impersonation and manipulate \ndata sent to the backend. An unauthenticated attacker can connect to the\n OCPP WebSocket endpoint using a known or discovered charging station \nidentifier, then issue or receive OCPP commands as a legitimate charger.\n Given that no authentication is required, this can lead to privilege \nescalation, unauthorized control of charging infrastructure, and \ncorruption of charging network data reported to the backend."
        },
        {
          "lang": "es",
          "value": "Los puntos finales WebSocket carecen de mecanismos de autenticaci\u00f3n adecuados, lo que permite a los atacantes realizar suplantaci\u00f3n de estaci\u00f3n no autorizada y manipular datos enviados al backend. Un atacante no autenticado puede conectarse al punto final WebSocket de OCPP utilizando un identificador de estaci\u00f3n de carga conocido o descubierto, luego emitir o recibir comandos OCPP como un cargador leg\u00edtimo. Dado que no se requiere autenticaci\u00f3n, esto puede llevar a escalada de privilegios, control no autorizado de la infraestructura de carga y corrupci\u00f3n de los datos de la red de carga reportados al backend."
        }
      ],
      "id": "CVE-2026-27772",
      "lastModified": "2026-06-17T10:27:39.900",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 9.4,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.5,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 9.3,
              "baseSeverity": "CRITICAL",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "LOW",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-27772",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-03-02T20:08:56.902918Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-02-27T00:16:58.250",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-057-07.json"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-07"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Product"
          ],
          "url": "https://www.ev.energy/en-us"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-306"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-26290

    Vulnerability from fkie_nvd - Published: 2026-02-27 01:16 - Updated: 2026-06-17 10:26
    Summary
    The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.
    Impacted products
    Vendor Product Version
    ev.energy ev.energy *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "ev.energy",
              "vendor": "EV Energy",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:ev.energy:ev.energy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6F8630FC-2F5D-4362-8AD7-F2A2A73A20F2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The WebSocket backend uses charging station identifiers to uniquely \nassociate sessions but allows multiple endpoints to connect using the \nsame session identifier. This implementation results in predictable \nsession identifiers and enables session hijacking or shadowing, where \nthe most recent connection displaces the legitimate charging station and\n receives backend commands intended for that station. This vulnerability\n may allow unauthorized users to authenticate as other users or enable a\n malicious actor to cause a denial-of-service condition by overwhelming \nthe backend with valid session requests."
        },
        {
          "lang": "es",
          "value": "El backend de WebSocket utiliza identificadores de estaciones de carga para asociar sesiones de forma \u00fanica, pero permite que m\u00faltiples puntos finales se conecten utilizando el mismo identificador de sesi\u00f3n. Esta implementaci\u00f3n da lugar a identificadores de sesi\u00f3n predecibles y permite el secuestro de sesi\u00f3n o shadowing, donde la conexi\u00f3n m\u00e1s reciente desplaza a la estaci\u00f3n de carga leg\u00edtima y recibe comandos del backend destinados a esa estaci\u00f3n. Esta vulnerabilidad puede permitir a usuarios no autorizados autenticarse como otros usuarios o permitir a un actor malicioso causar una condici\u00f3n de denegaci\u00f3n de servicio al sobrecargar el backend con solicitudes de sesi\u00f3n v\u00e1lidas."
        }
      ],
      "id": "CVE-2026-26290",
      "lastModified": "2026-06-17T10:26:03.110",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 7.3,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.4,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 6.9,
              "baseSeverity": "MEDIUM",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "LOW",
              "vulnConfidentialityImpact": "LOW",
              "vulnIntegrityImpact": "LOW",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-26290",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-03-03T01:31:16.300918Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-02-27T01:16:20.433",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-057-07.json"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-07"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Product"
          ],
          "url": "https://www.ev.energy/en-us"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-613"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-25774

    Vulnerability from fkie_nvd - Published: 2026-02-27 01:16 - Updated: 2026-06-17 10:25
    Summary
    Charging station authentication identifiers are publicly accessible via web-based mapping platforms.
    Impacted products
    Vendor Product Version
    ev.energy ev.energy *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "ev.energy",
              "vendor": "EV Energy",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:ev.energy:ev.energy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6F8630FC-2F5D-4362-8AD7-F2A2A73A20F2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Charging station authentication identifiers are publicly accessible via web-based mapping platforms."
        },
        {
          "lang": "es",
          "value": "Los identificadores de autenticaci\u00f3n de las estaciones de carga son de acceso p\u00fablico a trav\u00e9s de plataformas de mapeo basadas en la web."
        }
      ],
      "id": "CVE-2026-25774",
      "lastModified": "2026-06-17T10:25:12.723",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 2.5,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 6.9,
              "baseSeverity": "MEDIUM",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "NONE",
              "vulnConfidentialityImpact": "LOW",
              "vulnIntegrityImpact": "LOW",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-25774",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-03-03T01:30:35.931159Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-02-27T01:16:20.123",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-057-07.json"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-07"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Product"
          ],
          "url": "https://www.ev.energy/en-us"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-522"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-24445

    Vulnerability from fkie_nvd - Published: 2026-02-27 01:16 - Updated: 2026-06-17 10:23
    Summary
    The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access.
    Impacted products
    Vendor Product Version
    ev.energy ev.energy *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "ev.energy",
              "vendor": "EV Energy",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "ics-cert@hq.dhs.gov"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:ev.energy:ev.energy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6F8630FC-2F5D-4362-8AD7-F2A2A73A20F2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The WebSocket Application Programming Interface lacks restrictions on \nthe number of authentication requests. This absence of rate limiting may\n allow an attacker to conduct denial-of-service attacks by suppressing \nor mis-routing legitimate charger telemetry, or conduct brute-force \nattacks to gain unauthorized access."
        },
        {
          "lang": "es",
          "value": "La Interfaz de Programaci\u00f3n de Aplicaciones WebSocket carece de restricciones sobre el n\u00famero de solicitudes de autenticaci\u00f3n. Esta ausencia de limitaci\u00f3n de velocidad puede permitir a un atacante realizar ataques de denegaci\u00f3n de servicio al suprimir o redirigir incorrectamente la telemetr\u00eda leg\u00edtima del cargador, o realizar ataques de fuerza bruta para obtener acceso no autorizado."
        }
      ],
      "id": "CVE-2026-24445",
      "lastModified": "2026-06-17T10:23:05.303",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 8.7,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "NONE",
              "vulnIntegrityImpact": "NONE",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-24445",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-03-03T01:32:01.764241Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-02-27T01:16:18.430",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-057-07.json"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-07"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Product"
          ],
          "url": "https://www.ev.energy/en-us"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-307"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Secondary"
        }
      ]
    }

    CVE-2026-26290 (GCVE-0-2026-26290)

    Vulnerability from nvd – Published: 2026-02-27 00:13 – Updated: 2026-03-31 14:20
    VLAI
    Title
    EV Energy ev.energy Insufficient Session Expiration
    Summary
    The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-03 01:31 UTC
    CWE
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    Impacted products
    Vendor Product Version
    EV Energy ev.energy Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-26290",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-03T01:31:16.300918Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-31T14:20:41.450Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ev.energy",
              "vendor": "EV Energy",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Khaled Sarieddine and Mohammad Ali Sayed reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The WebSocket backend uses charging station identifiers to uniquely \nassociate sessions but allows multiple endpoints to connect using the \nsame session identifier. This implementation results in predictable \nsession identifiers and enables session hijacking or shadowing, where \nthe most recent connection displaces the legitimate charging station and\n receives backend commands intended for that station. This vulnerability\n may allow unauthorized users to authenticate as other users or enable a\n malicious actor to cause a denial-of-service condition by overwhelming \nthe backend with valid session requests."
                }
              ],
              "value": "The WebSocket backend uses charging station identifiers to uniquely \nassociate sessions but allows multiple endpoints to connect using the \nsame session identifier. This implementation results in predictable \nsession identifiers and enables session hijacking or shadowing, where \nthe most recent connection displaces the legitimate charging station and\n receives backend commands intended for that station. This vulnerability\n may allow unauthorized users to authenticate as other users or enable a\n malicious actor to cause a denial-of-service condition by overwhelming \nthe backend with valid session requests."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-613",
                  "description": "CWE-613",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-05T20:36:19.330Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.ev.energy/en-us"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-07"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-057-07.json"
            }
          ],
          "source": {
            "advisory": "ICSA-26-057-07",
            "discovery": "EXTERNAL"
          },
          "title": "EV Energy ev.energy Insufficient Session Expiration",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ev.energy/en-us\"\u003ehttps://www.ev.energy/en-us\u003c/a\u003e for \nmore information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here:  https://www.ev.energy/en-us  for \nmore information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-26290",
        "datePublished": "2026-02-27T00:13:16.357Z",
        "dateReserved": "2026-02-24T00:16:49.674Z",
        "dateUpdated": "2026-03-31T14:20:41.450Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-25774 (GCVE-0-2026-25774)

    Vulnerability from nvd – Published: 2026-02-27 00:15 – Updated: 2026-04-08 15:03
    VLAI
    Title
    EV Energy ev.energy Insufficiently Protected Credentials
    Summary
    Charging station authentication identifiers are publicly accessible via web-based mapping platforms.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-03 01:30 UTC
    CWE
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    Impacted products
    Vendor Product Version
    EV Energy ev.energy Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-25774",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-03T01:30:35.931159Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-08T15:03:34.669Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ev.energy",
              "vendor": "EV Energy",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Khaled Sarieddine and Mohammad Ali Sayed reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Charging station authentication identifiers are publicly accessible via web-based mapping platforms."
                }
              ],
              "value": "Charging station authentication identifiers are publicly accessible via web-based mapping platforms."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-522",
                  "description": "CWE-522",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-05T20:27:06.569Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.ev.energy/en-us"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-07"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-057-07.json"
            }
          ],
          "source": {
            "advisory": "ICSA-26-057-07",
            "discovery": "EXTERNAL"
          },
          "title": "EV Energy ev.energy Insufficiently Protected Credentials",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ev.energy/en-us\"\u003ehttps://www.ev.energy/en-us\u003c/a\u003e for \nmore information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here:  https://www.ev.energy/en-us  for \nmore information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-25774",
        "datePublished": "2026-02-27T00:15:14.924Z",
        "dateReserved": "2026-02-24T00:16:49.664Z",
        "dateUpdated": "2026-04-08T15:03:34.669Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-24445 (GCVE-0-2026-24445)

    Vulnerability from nvd – Published: 2026-02-27 00:11 – Updated: 2026-03-31 14:20
    VLAI
    Title
    EV Energy ev.energy Improper Restriction of Excessive Authentication Attempts
    Summary
    The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-03 01:32 UTC
    CWE
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    Impacted products
    Vendor Product Version
    EV Energy ev.energy Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-24445",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-03T01:32:01.764241Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-31T14:20:24.074Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ev.energy",
              "vendor": "EV Energy",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Khaled Sarieddine and Mohammad Ali Sayed reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The WebSocket Application Programming Interface lacks restrictions on \nthe number of authentication requests. This absence of rate limiting may\n allow an attacker to conduct denial-of-service attacks by suppressing \nor mis-routing legitimate charger telemetry, or conduct brute-force \nattacks to gain unauthorized access."
                }
              ],
              "value": "The WebSocket Application Programming Interface lacks restrictions on \nthe number of authentication requests. This absence of rate limiting may\n allow an attacker to conduct denial-of-service attacks by suppressing \nor mis-routing legitimate charger telemetry, or conduct brute-force \nattacks to gain unauthorized access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-307",
                  "description": "CWE-307",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-05T20:15:06.591Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.ev.energy/en-us"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-07"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-057-07.json"
            }
          ],
          "source": {
            "advisory": "ICSA-26-057-07",
            "discovery": "EXTERNAL"
          },
          "title": "EV Energy ev.energy Improper Restriction of Excessive Authentication Attempts",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ev.energy/en-us\"\u003ehttps://www.ev.energy/en-us\u003c/a\u003e for \nmore information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here:  https://www.ev.energy/en-us  for \nmore information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-24445",
        "datePublished": "2026-02-27T00:11:15.055Z",
        "dateReserved": "2026-02-24T00:16:49.682Z",
        "dateUpdated": "2026-03-31T14:20:24.074Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-27772 (GCVE-0-2026-27772)

    Vulnerability from nvd – Published: 2026-02-27 00:09 – Updated: 2026-03-05 20:45
    VLAI
    Title
    EV Energy ev.energy Missing Authentication for Critical Function
    Summary
    WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-02 20:08 UTC
    CWE
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    Impacted products
    Vendor Product Version
    EV Energy ev.energy Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-27772",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-02T20:08:56.902918Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-02T20:09:05.523Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ev.energy",
              "vendor": "EV Energy",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Khaled Sarieddine and Mohammad Ali Sayed reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "WebSocket endpoints lack proper authentication mechanisms, enabling \nattackers to perform unauthorized station impersonation and manipulate \ndata sent to the backend. An unauthenticated attacker can connect to the\n OCPP WebSocket endpoint using a known or discovered charging station \nidentifier, then issue or receive OCPP commands as a legitimate charger.\n Given that no authentication is required, this can lead to privilege \nescalation, unauthorized control of charging infrastructure, and \ncorruption of charging network data reported to the backend."
                }
              ],
              "value": "WebSocket endpoints lack proper authentication mechanisms, enabling \nattackers to perform unauthorized station impersonation and manipulate \ndata sent to the backend. An unauthenticated attacker can connect to the\n OCPP WebSocket endpoint using a known or discovered charging station \nidentifier, then issue or receive OCPP commands as a legitimate charger.\n Given that no authentication is required, this can lead to privilege \nescalation, unauthorized control of charging infrastructure, and \ncorruption of charging network data reported to the backend."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-05T20:45:17.841Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.ev.energy/en-us"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-07"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-057-07.json"
            }
          ],
          "source": {
            "advisory": "ICSA-26-057-07",
            "discovery": "EXTERNAL"
          },
          "title": "EV Energy ev.energy Missing Authentication for Critical Function",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ev.energy/en-us\"\u003ehttps://www.ev.energy/en-us\u003c/a\u003e for \nmore information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here:  https://www.ev.energy/en-us  for \nmore information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-27772",
        "datePublished": "2026-02-27T00:09:12.986Z",
        "dateReserved": "2026-02-24T00:16:49.691Z",
        "dateUpdated": "2026-03-05T20:45:17.841Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-25774 (GCVE-0-2026-25774)

    Vulnerability from cvelistv5 – Published: 2026-02-27 00:15 – Updated: 2026-04-08 15:03
    VLAI
    Title
    EV Energy ev.energy Insufficiently Protected Credentials
    Summary
    Charging station authentication identifiers are publicly accessible via web-based mapping platforms.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-03 01:30 UTC
    CWE
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    Impacted products
    Vendor Product Version
    EV Energy ev.energy Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-25774",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-03T01:30:35.931159Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-08T15:03:34.669Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ev.energy",
              "vendor": "EV Energy",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Khaled Sarieddine and Mohammad Ali Sayed reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Charging station authentication identifiers are publicly accessible via web-based mapping platforms."
                }
              ],
              "value": "Charging station authentication identifiers are publicly accessible via web-based mapping platforms."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-522",
                  "description": "CWE-522",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-05T20:27:06.569Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.ev.energy/en-us"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-07"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-057-07.json"
            }
          ],
          "source": {
            "advisory": "ICSA-26-057-07",
            "discovery": "EXTERNAL"
          },
          "title": "EV Energy ev.energy Insufficiently Protected Credentials",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ev.energy/en-us\"\u003ehttps://www.ev.energy/en-us\u003c/a\u003e for \nmore information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here:  https://www.ev.energy/en-us  for \nmore information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-25774",
        "datePublished": "2026-02-27T00:15:14.924Z",
        "dateReserved": "2026-02-24T00:16:49.664Z",
        "dateUpdated": "2026-04-08T15:03:34.669Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-26290 (GCVE-0-2026-26290)

    Vulnerability from cvelistv5 – Published: 2026-02-27 00:13 – Updated: 2026-03-31 14:20
    VLAI
    Title
    EV Energy ev.energy Insufficient Session Expiration
    Summary
    The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-03 01:31 UTC
    CWE
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    Impacted products
    Vendor Product Version
    EV Energy ev.energy Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-26290",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-03T01:31:16.300918Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-31T14:20:41.450Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ev.energy",
              "vendor": "EV Energy",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Khaled Sarieddine and Mohammad Ali Sayed reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The WebSocket backend uses charging station identifiers to uniquely \nassociate sessions but allows multiple endpoints to connect using the \nsame session identifier. This implementation results in predictable \nsession identifiers and enables session hijacking or shadowing, where \nthe most recent connection displaces the legitimate charging station and\n receives backend commands intended for that station. This vulnerability\n may allow unauthorized users to authenticate as other users or enable a\n malicious actor to cause a denial-of-service condition by overwhelming \nthe backend with valid session requests."
                }
              ],
              "value": "The WebSocket backend uses charging station identifiers to uniquely \nassociate sessions but allows multiple endpoints to connect using the \nsame session identifier. This implementation results in predictable \nsession identifiers and enables session hijacking or shadowing, where \nthe most recent connection displaces the legitimate charging station and\n receives backend commands intended for that station. This vulnerability\n may allow unauthorized users to authenticate as other users or enable a\n malicious actor to cause a denial-of-service condition by overwhelming \nthe backend with valid session requests."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-613",
                  "description": "CWE-613",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-05T20:36:19.330Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.ev.energy/en-us"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-07"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-057-07.json"
            }
          ],
          "source": {
            "advisory": "ICSA-26-057-07",
            "discovery": "EXTERNAL"
          },
          "title": "EV Energy ev.energy Insufficient Session Expiration",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ev.energy/en-us\"\u003ehttps://www.ev.energy/en-us\u003c/a\u003e for \nmore information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here:  https://www.ev.energy/en-us  for \nmore information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-26290",
        "datePublished": "2026-02-27T00:13:16.357Z",
        "dateReserved": "2026-02-24T00:16:49.674Z",
        "dateUpdated": "2026-03-31T14:20:41.450Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-24445 (GCVE-0-2026-24445)

    Vulnerability from cvelistv5 – Published: 2026-02-27 00:11 – Updated: 2026-03-31 14:20
    VLAI
    Title
    EV Energy ev.energy Improper Restriction of Excessive Authentication Attempts
    Summary
    The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-03 01:32 UTC
    CWE
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    Impacted products
    Vendor Product Version
    EV Energy ev.energy Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-24445",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-03T01:32:01.764241Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-31T14:20:24.074Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ev.energy",
              "vendor": "EV Energy",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Khaled Sarieddine and Mohammad Ali Sayed reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The WebSocket Application Programming Interface lacks restrictions on \nthe number of authentication requests. This absence of rate limiting may\n allow an attacker to conduct denial-of-service attacks by suppressing \nor mis-routing legitimate charger telemetry, or conduct brute-force \nattacks to gain unauthorized access."
                }
              ],
              "value": "The WebSocket Application Programming Interface lacks restrictions on \nthe number of authentication requests. This absence of rate limiting may\n allow an attacker to conduct denial-of-service attacks by suppressing \nor mis-routing legitimate charger telemetry, or conduct brute-force \nattacks to gain unauthorized access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-307",
                  "description": "CWE-307",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-05T20:15:06.591Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.ev.energy/en-us"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-07"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-057-07.json"
            }
          ],
          "source": {
            "advisory": "ICSA-26-057-07",
            "discovery": "EXTERNAL"
          },
          "title": "EV Energy ev.energy Improper Restriction of Excessive Authentication Attempts",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ev.energy/en-us\"\u003ehttps://www.ev.energy/en-us\u003c/a\u003e for \nmore information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here:  https://www.ev.energy/en-us  for \nmore information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-24445",
        "datePublished": "2026-02-27T00:11:15.055Z",
        "dateReserved": "2026-02-24T00:16:49.682Z",
        "dateUpdated": "2026-03-31T14:20:24.074Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-27772 (GCVE-0-2026-27772)

    Vulnerability from cvelistv5 – Published: 2026-02-27 00:09 – Updated: 2026-03-05 20:45
    VLAI
    Title
    EV Energy ev.energy Missing Authentication for Critical Function
    Summary
    WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-03-02 20:08 UTC
    CWE
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 344 records in the last 180 days details
    Impacted products
    Vendor Product Version
    EV Energy ev.energy Affected: All versions
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-27772",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-02T20:08:56.902918Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-02T20:09:05.523Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ev.energy",
              "vendor": "EV Energy",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Khaled Sarieddine and Mohammad Ali Sayed reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "WebSocket endpoints lack proper authentication mechanisms, enabling \nattackers to perform unauthorized station impersonation and manipulate \ndata sent to the backend. An unauthenticated attacker can connect to the\n OCPP WebSocket endpoint using a known or discovered charging station \nidentifier, then issue or receive OCPP commands as a legitimate charger.\n Given that no authentication is required, this can lead to privilege \nescalation, unauthorized control of charging infrastructure, and \ncorruption of charging network data reported to the backend."
                }
              ],
              "value": "WebSocket endpoints lack proper authentication mechanisms, enabling \nattackers to perform unauthorized station impersonation and manipulate \ndata sent to the backend. An unauthenticated attacker can connect to the\n OCPP WebSocket endpoint using a known or discovered charging station \nidentifier, then issue or receive OCPP commands as a legitimate charger.\n Given that no authentication is required, this can lead to privilege \nescalation, unauthorized control of charging infrastructure, and \ncorruption of charging network data reported to the backend."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-05T20:45:17.841Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.ev.energy/en-us"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-057-07"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-057-07.json"
            }
          ],
          "source": {
            "advisory": "ICSA-26-057-07",
            "discovery": "EXTERNAL"
          },
          "title": "EV Energy ev.energy Missing Authentication for Critical Function",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ev.energy/en-us\"\u003ehttps://www.ev.energy/en-us\u003c/a\u003e for \nmore information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "EV Energy did not respond to CISA\u0027s request for coordination. Contact EV\n Energy using their contact page here:  https://www.ev.energy/en-us  for \nmore information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-27772",
        "datePublished": "2026-02-27T00:09:12.986Z",
        "dateReserved": "2026-02-24T00:16:49.691Z",
        "dateUpdated": "2026-03-05T20:45:17.841Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }