Search
Find a vulnerability
Search criteria
24 vulnerabilities found for er707-m2_firmware by tp-link
FKIE_CVE-2026-19586
Vulnerability from fkie_nvd - Published: 2026-08-20 19:16 - Updated: 2026-10-26 10:10
Severity
Summary
A pre-authentication OS command injection vulnerability has been identified in Omada gateways configured to operate as an OpenVPN Server due to insufficient validation of client-supplied data during OpenVPN connection establishment. An unauthenticated remote attacker may provide specially crafted input influencing backend command execution logic before authentication completes. Exploitation requires the OpenVPN Server feature to be enabled, VPN service reachable by the attacker and attacker to be able to initiate an OpenVPN connection attempt.
Successful exploitation may allow arbitrary command execution, potentially
leading to full compromise of the affected device.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "ER7212PC v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.3 Build 20260722 Rel.40250",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.4 Build 20260630 Rel.14398",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7206 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.5 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7406 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.3.4 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER707-M2 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.4 Build 20260625 Rel.43063",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7412-M2 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82947",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER8411 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.1 Build 20260708 Rel.64832",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.11 Build 20260723 Rel.41567",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.6 Build 20260723 Rel.41321",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706WP-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER703WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.7 Build 20260723 Rel.41712",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3220v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82652",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83311",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83347",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER603WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.2 Build 20260723 Rel.43271",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3150 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20260722 Rel.16854",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER701-5G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20260723 Rel.40931",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605W v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.4 Build 20260723 Rel.43763",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7D4F7E2D-BC8F-473D-938B-8E907538FB84",
"versionEndExcluding": "2.4.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "939EE8A4-1CA6-495C-83B0-369B4367A402",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7DE29DB-20CA-4C32-A050-22C0C208683D",
"versionEndExcluding": "2.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "11B180B7-7FE9-4971-9F1A-9FD2A73FA9C3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6BEB928F-A260-4ADC-8AE7-EA118D6CBA4E",
"versionEndExcluding": "2.0.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605w:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "5AE8F6F3-D20F-4151-9BEA-F3BF930A9060",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9FEBEB59-E7F4-45CE-A4FF-01169FB6D7A4",
"versionEndExcluding": "2.3.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "4B8866B3-837C-47E0-94DD-CE771083CCD6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7406_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "36C3A9CA-B374-4B30-8647-867DCBDA888F",
"versionEndExcluding": "1.3.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7406:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3064CDE7-9329-4D22-8853-B4EE6D050D4B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5C8E5FC5-FB02-4884-8561-16462A7FB015",
"versionEndExcluding": "1.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "52DFB291-70BB-49C1-B50F-E084CDCE56D6",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14F8B834-3A2F-4B8B-BF3C-4C915F9C91B2",
"versionEndExcluding": "1.4.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1DC2E6EB-47E1-4B3F-AE07-6E9C1120885E",
"versionEndExcluding": "1.2.11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "41F765B0-E24B-4EED-AC37-B54638DFBD3F",
"versionEndExcluding": "1.2.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C596A89-C9E9-4F8E-BD9F-6B807E3D568E",
"versionEndExcluding": "2.1.11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DE1504A8-4FDC-44E0-9C97-2AC838DC4FBF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706wp-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8886DEC9-65FE-4D88-B829-7082B7F27B8E",
"versionEndExcluding": "1.1.11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706wp-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDF76B4C-3657-4C55-AC76-A31FC5A988A8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er703wp-4g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FFB8FCED-5F12-4631-857F-6F713558CA67",
"versionEndExcluding": "1.1.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er703wp-4g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9984C375-4F11-4C3A-AB3D-9A23C4B9EE77",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er603wp-4g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C516C8C6-29EB-4614-B8B3-C1D15AED69E8",
"versionEndExcluding": "1.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er603wp-4g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE399BF3-D90E-4B4C-80B5-819715DC366F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er701-5g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F5D2B103-3A11-4F8D-B94E-E9394BF39A35",
"versionEndExcluding": "1.0.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er701-5g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2082ECC6-BC83-4D1A-A9E3-D8F3215D43E1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3220v-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8F715148-236F-4EA0-9389-39AC93E3217C",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3220v-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CAA74D58-481A-40B3-BEC7-AD1782802C51",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3650v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "16677C43-4338-4444-BBA6-C3A05AF167E5",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3650v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CD34FB5F-D4EA-41E3-B625-78A8045AC916",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3650v-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "178A4ACF-15AB-4BAD-8EE9-1AB660220489",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3650v-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "121CBA17-EB12-4611-B05B-A39C8DE06410",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3150_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "36033FDC-3905-4958-9B0E-2A834A4CDF80",
"versionEndExcluding": "1.0.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3150:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E4B44058-8C05-4A29-81A7-113B0B6BCAE2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A pre-authentication OS command injection vulnerability has been identified in Omada gateways configured to operate as an OpenVPN Server due to insufficient validation of client-supplied data during OpenVPN connection establishment. An unauthenticated remote attacker may provide specially crafted input influencing backend command execution logic before authentication completes. Exploitation requires the OpenVPN Server feature to be enabled, VPN service reachable by the attacker and attacker to be able to initiate an OpenVPN connection attempt.\u00a0\n\n\n\nSuccessful exploitation may allow arbitrary command execution,\u00a0potentially\nleading to full compromise of the affected device."
},
{
"lang": "es",
"value": "Una vulnerabilidad de inyecci\u00f3n de comandos del sistema operativo pre-autenticaci\u00f3n ha sido identificada en gateways Omada configurados para operar como un servidor OpenVPN debido a una validaci\u00f3n insuficiente de los datos proporcionados por el cliente durante el establecimiento de la conexi\u00f3n OpenVPN. Un atacante remoto no autenticado puede proporcionar una entrada especialmente dise\u00f1ada que influye en la l\u00f3gica de ejecuci\u00f3n de comandos del backend antes de que la autenticaci\u00f3n se complete. La explotaci\u00f3n requiere que la caracter\u00edstica de servidor OpenVPN est\u00e9 habilitada, que el servicio VPN sea accesible por el atacante y que el atacante pueda iniciar un intento de conexi\u00f3n OpenVPN.\n\nLa explotaci\u00f3n exitosa puede permitir la ejecuci\u00f3n arbitraria de comandos, lo que podr\u00eda llevar a un compromiso total del dispositivo afectado."
}
],
"id": "CVE-2026-19586",
"lastModified": "2026-10-26T10:10:00.140",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-19586",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T00:00:00+00:00",
"version": "2.0.3"
}
}
]
},
"published": "2026-08-20T19:16:51.103",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://mattg.systems/posts/cve-2026-19586/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/en/support/download/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/support/download/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://www.tp-link.com/us/support/faq/5256/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
]
}
FKIE_CVE-2026-9033
Vulnerability from fkie_nvd - Published: 2026-08-20 19:17 - Updated: 2026-10-26 10:10
Severity
Summary
An unauthenticated attacker with network access to the captive portal service of an affected device can terminate active captive portal sessions, including forcing logout of specific users or clearing all active sessions. Affected users must re-authenticate to regain access.
Successful exploitation may allow termination of individual or all active captive portal sessions, causing temporary service disruption and requiring users to re-authenticate.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "ER7212PC v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.3 Build 20260722 Rel.40250",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.4 Build 20260630 Rel.14398",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7206 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.5 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7406 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.3.4 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER707-M2 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.4 Build 20260625 Rel.43063",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7412-M2 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82947",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER8411 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.1 Build 20260708 Rel.64832",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.11 Build 20260723 Rel.41567",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.6 Build 20260723 Rel.41321",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706WP-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER703WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.7 Build 20260723 Rel.41712",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3220v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82652",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83311",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83347",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER603WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.2 Build 20260723 Rel.43271",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3150 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20260722 Rel.16854",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER701-5G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20260723 Rel.40931",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605W v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.4 Build 20260723 Rel.43763",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7D4F7E2D-BC8F-473D-938B-8E907538FB84",
"versionEndExcluding": "2.4.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "939EE8A4-1CA6-495C-83B0-369B4367A402",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7DE29DB-20CA-4C32-A050-22C0C208683D",
"versionEndExcluding": "2.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "11B180B7-7FE9-4971-9F1A-9FD2A73FA9C3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9FEBEB59-E7F4-45CE-A4FF-01169FB6D7A4",
"versionEndExcluding": "2.3.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "4B8866B3-837C-47E0-94DD-CE771083CCD6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7406_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "36C3A9CA-B374-4B30-8647-867DCBDA888F",
"versionEndExcluding": "1.3.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7406:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3064CDE7-9329-4D22-8853-B4EE6D050D4B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5C8E5FC5-FB02-4884-8561-16462A7FB015",
"versionEndExcluding": "1.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "52DFB291-70BB-49C1-B50F-E084CDCE56D6",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14F8B834-3A2F-4B8B-BF3C-4C915F9C91B2",
"versionEndExcluding": "1.4.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1DC2E6EB-47E1-4B3F-AE07-6E9C1120885E",
"versionEndExcluding": "1.2.11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "41F765B0-E24B-4EED-AC37-B54638DFBD3F",
"versionEndExcluding": "1.2.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C596A89-C9E9-4F8E-BD9F-6B807E3D568E",
"versionEndExcluding": "2.1.11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DE1504A8-4FDC-44E0-9C97-2AC838DC4FBF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706wp-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8886DEC9-65FE-4D88-B829-7082B7F27B8E",
"versionEndExcluding": "1.1.11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706wp-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDF76B4C-3657-4C55-AC76-A31FC5A988A8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er703wp-4g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FFB8FCED-5F12-4631-857F-6F713558CA67",
"versionEndExcluding": "1.1.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er703wp-4g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9984C375-4F11-4C3A-AB3D-9A23C4B9EE77",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3220v-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8F715148-236F-4EA0-9389-39AC93E3217C",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3220v-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CAA74D58-481A-40B3-BEC7-AD1782802C51",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3650v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "16677C43-4338-4444-BBA6-C3A05AF167E5",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3650v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CD34FB5F-D4EA-41E3-B625-78A8045AC916",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3650v-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "178A4ACF-15AB-4BAD-8EE9-1AB660220489",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3650v-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "121CBA17-EB12-4611-B05B-A39C8DE06410",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er603wp-4g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C516C8C6-29EB-4614-B8B3-C1D15AED69E8",
"versionEndExcluding": "1.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er603wp-4g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE399BF3-D90E-4B4C-80B5-819715DC366F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3150_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "36033FDC-3905-4958-9B0E-2A834A4CDF80",
"versionEndExcluding": "1.0.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3150:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E4B44058-8C05-4A29-81A7-113B0B6BCAE2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er701-5g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F5D2B103-3A11-4F8D-B94E-E9394BF39A35",
"versionEndExcluding": "1.0.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er701-5g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2082ECC6-BC83-4D1A-A9E3-D8F3215D43E1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6BEB928F-A260-4ADC-8AE7-EA118D6CBA4E",
"versionEndExcluding": "2.0.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605w:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "5AE8F6F3-D20F-4151-9BEA-F3BF930A9060",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated attacker with network access to the captive portal service of an affected device can terminate active captive portal sessions, including forcing logout of specific users or clearing all active sessions. Affected users must re-authenticate to regain access.\u00a0\n\n\n\nSuccessful exploitation may allow termination of individual or all active captive portal sessions, causing temporary service disruption and requiring users to re-authenticate."
},
{
"lang": "es",
"value": "Un atacante no autenticado con acceso de red al servicio de portal cautivo de un dispositivo afectado puede terminar sesiones activas de portal cautivo, incluyendo forzar el cierre de sesi\u00f3n de usuarios espec\u00edficos o borrar todas las sesiones activas. Los usuarios afectados deben volver a autenticarse para recuperar el acceso.\n\nLa explotaci\u00f3n exitosa puede permitir la terminaci\u00f3n de sesiones individuales o de todas las sesiones activas de portal cautivo, causando una interrupci\u00f3n temporal del servicio y requiriendo que los usuarios se vuelvan a autenticar."
}
],
"id": "CVE-2026-9033",
"lastModified": "2026-10-26T10:10:00.140",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.0,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-9033",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T18:59:29.032581Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-08-20T19:17:04.950",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/en/support/download/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/support/download/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://www.tp-link.com/us/support/faq/5256/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
]
}
FKIE_CVE-2026-19683
Vulnerability from fkie_nvd - Published: 2026-08-20 19:16 - Updated: 2026-10-26 10:10
Severity
Summary
A vulnerability exists in the Dynamic DNS (DDNS) functionality of TP-Link Omada Gateways. During communication with a third-party DDNS service, authentication credentials are transmitted over an unencrypted channel. An attacker who can observe or manipulate traffic between an affected device and the DDNS service may obtain sensitive authentication information or interfere with DDNS update operations. Exploitation requires DDNS to be configured, communication with an external DDNS service, and attacker visibility or control of the relevant network path.
Successful exploitation may result in disclosure of DDNS account credentials, unauthorized access to DDNS management functionality, or modification of DNS records associated with the affected deployment.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "ER7212PC v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.3 Build 20260722 Rel.40250",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.4 Build 20260630 Rel.14398",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7206 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.5 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7406 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.3.4 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER707-M2 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.4 Build 20260625 Rel.43063",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7412-M2 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82947",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER8411 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.1 Build 20260708 Rel.64832",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.11 Build 20260723 Rel.41567",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.6 Build 20260723 Rel.41321",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706WP-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER703WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.7 Build 20260723 Rel.41712",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3220v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82652",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83311",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83347",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER603WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.2 Build 20260723 Rel.43271",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3150 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20260722 Rel.16854",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER701-5G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20260723 Rel.40931",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605W v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.4 Build 20260723 Rel.43763",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7D4F7E2D-BC8F-473D-938B-8E907538FB84",
"versionEndExcluding": "2.4.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "939EE8A4-1CA6-495C-83B0-369B4367A402",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7DE29DB-20CA-4C32-A050-22C0C208683D",
"versionEndExcluding": "2.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "11B180B7-7FE9-4971-9F1A-9FD2A73FA9C3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9FEBEB59-E7F4-45CE-A4FF-01169FB6D7A4",
"versionEndExcluding": "2.3.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "4B8866B3-837C-47E0-94DD-CE771083CCD6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7406_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "36C3A9CA-B374-4B30-8647-867DCBDA888F",
"versionEndExcluding": "1.3.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7406:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3064CDE7-9329-4D22-8853-B4EE6D050D4B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5C8E5FC5-FB02-4884-8561-16462A7FB015",
"versionEndExcluding": "1.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "52DFB291-70BB-49C1-B50F-E084CDCE56D6",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14F8B834-3A2F-4B8B-BF3C-4C915F9C91B2",
"versionEndExcluding": "1.4.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1DC2E6EB-47E1-4B3F-AE07-6E9C1120885E",
"versionEndExcluding": "1.2.11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "41F765B0-E24B-4EED-AC37-B54638DFBD3F",
"versionEndExcluding": "1.2.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C596A89-C9E9-4F8E-BD9F-6B807E3D568E",
"versionEndExcluding": "2.1.11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DE1504A8-4FDC-44E0-9C97-2AC838DC4FBF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706wp-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8886DEC9-65FE-4D88-B829-7082B7F27B8E",
"versionEndExcluding": "1.1.11",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706wp-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDF76B4C-3657-4C55-AC76-A31FC5A988A8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er703wp-4g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FFB8FCED-5F12-4631-857F-6F713558CA67",
"versionEndExcluding": "1.1.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er703wp-4g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9984C375-4F11-4C3A-AB3D-9A23C4B9EE77",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3220v-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8F715148-236F-4EA0-9389-39AC93E3217C",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3220v-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CAA74D58-481A-40B3-BEC7-AD1782802C51",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3650v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "16677C43-4338-4444-BBA6-C3A05AF167E5",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3650v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CD34FB5F-D4EA-41E3-B625-78A8045AC916",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3650v-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "178A4ACF-15AB-4BAD-8EE9-1AB660220489",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3650v-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "121CBA17-EB12-4611-B05B-A39C8DE06410",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er603wp-4g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C516C8C6-29EB-4614-B8B3-C1D15AED69E8",
"versionEndExcluding": "1.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er603wp-4g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EE399BF3-D90E-4B4C-80B5-819715DC366F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3150_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "36033FDC-3905-4958-9B0E-2A834A4CDF80",
"versionEndExcluding": "1.0.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3150:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E4B44058-8C05-4A29-81A7-113B0B6BCAE2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er701-5g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F5D2B103-3A11-4F8D-B94E-E9394BF39A35",
"versionEndExcluding": "1.0.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er701-5g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2082ECC6-BC83-4D1A-A9E3-D8F3215D43E1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6BEB928F-A260-4ADC-8AE7-EA118D6CBA4E",
"versionEndExcluding": "2.0.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605w:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "5AE8F6F3-D20F-4151-9BEA-F3BF930A9060",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the Dynamic DNS (DDNS) functionality of TP-Link Omada Gateways. During communication with a third-party DDNS service, authentication credentials are transmitted over an unencrypted channel. An attacker who can\u00a0observe\u00a0or manipulate traffic between an affected device and the DDNS service may obtain sensitive authentication information or interfere with DDNS update operations. Exploitation requires DDNS to be configured, communication with an external DDNS service, and attacker visibility or control of the relevant network path.\u00a0\n\n\n\n\n\nSuccessful exploitation may result in disclosure of DDNS account credentials, unauthorized access to DDNS management functionality, or modification of DNS records associated with the affected deployment."
},
{
"lang": "es",
"value": "Una vulnerabilidad existe en la funcionalidad de DNS Din\u00e1mico (DDNS) de los Gateways TP-Link Omada. Durante la comunicaci\u00f3n con un servicio DDNS de terceros, las credenciales de autenticaci\u00f3n se transmiten a trav\u00e9s de un canal no cifrado. Un atacante que puede observar o manipular el tr\u00e1fico entre un dispositivo afectado y el servicio DDNS puede obtener informaci\u00f3n de autenticaci\u00f3n sensible o interferir con las operaciones de actualizaci\u00f3n de DDNS. La explotaci\u00f3n requiere que el DDNS est\u00e9 configurado, comunicaci\u00f3n con un servicio DDNS externo, y visibilidad o control del atacante de la ruta de red relevante.\n\nLa explotaci\u00f3n exitosa puede resultar en la divulgaci\u00f3n de credenciales de cuenta DDNS, acceso no autorizado a la funcionalidad de gesti\u00f3n de DDNS, o la modificaci\u00f3n de registros DNS asociados con la implementaci\u00f3n afectada."
}
],
"id": "CVE-2026-19683",
"lastModified": "2026-10-26T10:10:00.140",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-19683",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T18:55:44.295305Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-08-20T19:16:51.303",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/en/support/download/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/support/download/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://www.tp-link.com/us/support/faq/5256/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-319"
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-6542
Vulnerability from fkie_nvd - Published: 2025-10-21 01:15 - Updated: 2026-10-18 21:10
Severity
Summary
An arbitrary OS command may be executed on the product by a remote unauthenticated attacker.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | er8411_firmware | * | |
| tp-link | er8411_firmware | 1.3.3 | |
| tp-link | er8411 | - | |
| tp-link | er7412-m2_firmware | * | |
| tp-link | er7412-m2_firmware | 1.1.0 | |
| tp-link | er7412-m2 | - | |
| tp-link | er707-m2_firmware | * | |
| tp-link | er707-m2_firmware | 1.3.1 | |
| tp-link | er707-m2 | - | |
| tp-link | er7206_firmware | * | |
| tp-link | er7206_firmware | 2.2.2 | |
| tp-link | er7206 | - | |
| tp-link | er605_firmware | * | |
| tp-link | er605_firmware | 2.3.1 | |
| tp-link | er605 | - | |
| tp-link | er706w_firmware | * | |
| tp-link | er706w_firmware | 1.2.1 | |
| tp-link | er706w | - | |
| tp-link | er706w-4g_firmware | * | |
| tp-link | er706w-4g_firmware | 1.2.1 | |
| tp-link | er706w-4g | - | |
| tp-link | er7212pc_firmware | * | |
| tp-link | er7212pc_firmware | 2.1.3 | |
| tp-link | er7212pc | - | |
| tp-link | g36_firmware | * | |
| tp-link | g36_firmware | 1.1.4 | |
| tp-link | g36 | - | |
| tp-link | g611_firmware | * | |
| tp-link | g611_firmware | 1.2.2 | |
| tp-link | g611 | - | |
| tp-link | fr365_firmware | * | |
| tp-link | fr365_firmware | 1.1.10 | |
| tp-link | fr365 | - | |
| tp-link | fr205_firmware | * | |
| tp-link | fr205_firmware | 1.0.3 | |
| tp-link | fr205 | - | |
| tp-link | fr307-m2_firmware | * | |
| tp-link | fr307-m2_firmware | 1.2.5 | |
| tp-link | fr307-m2 | - |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE0D8327-33EE-4EF0-BC2F-F2A16D55762A",
"versionEndExcluding": "1.3.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:1.3.3:-:*:*:*:*:*:*",
"matchCriteriaId": "6DB13EF6-0930-4575-92DC-AF431B2A2CEF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14CE8275-E546-4598-901C-F52355DED3C9",
"versionEndExcluding": "1.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:1.1.0:-:*:*:*:*:*:*",
"matchCriteriaId": "B79E0763-6D6F-4E59-91FC-D397A8BEF0F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48EDBC5B-BA54-4D11-9391-4FA7C7D4F5E7",
"versionEndExcluding": "1.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:1.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "359ADA2C-F1A5-4840-8F84-2DBA8F4573C4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF595A8A-72CF-406E-BB0C-B76FDD51150B",
"versionEndExcluding": "2.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:2.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "8F66B05E-0D03-4B59-BCA3-7A2F40F092EE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB65324D-FD72-4C28-92AF-85BFF1E8A993",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8EA51B29-39FB-4880-979B-3F612DE9D202",
"versionEndExcluding": "2.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:2.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "1D1D1C14-E0F9-430D-BAC5-4F0C7287FD26",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9892BC7C-6EA7-469B-AD26-6E5093DB5AB2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47273FE0-6E22-437E-B27F-058456E7602A",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "AC30DFD7-30FD-482C-B8EF-9DDB98E269BF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E1BC6D9F-A556-468A-8770-6A39F09F26D6",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "96944BD2-388F-4CF6-BFD3-473EE6624F74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6CE877B8-E287-4FE6-84D5-666FE27AC9A6",
"versionEndExcluding": "2.1.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:2.1.3:-:*:*:*:*:*:*",
"matchCriteriaId": "24860FF1-7CA9-47D4-90B6-CB8915F1D992",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F300A161-E1A3-469E-9DE3-9B052F6BA8AC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EB884461-7A80-44B0-A200-25D7E0EB5152",
"versionEndExcluding": "1.1.4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:1.1.4:-:*:*:*:*:*:*",
"matchCriteriaId": "BDA7D066-8443-4D6F-8E22-A0845236B490",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g36:-:*:*:*:*:*:*:*",
"matchCriteriaId": "153073B7-9FBD-47D0-A1AB-CEE323AE5512",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E6F8E98F-0C86-40C0-BBD3-D2B1889BAA87",
"versionEndExcluding": "1.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:1.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "5FF584E3-70F0-4B05-857B-CE07D87BA130",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g611:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D4BA74E1-BDA0-4FDD-820A-8DE32EEE2AA7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D38B9DBD-3397-40B8-B4A5-C1E0C248C300",
"versionEndExcluding": "1.1.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:1.1.10:-:*:*:*:*:*:*",
"matchCriteriaId": "4DA30139-EBED-40FD-BA20-CED14607B648",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr365:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFB3D95C-C64A-48A6-8D13-E158CFB3CC7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7FC1549-BC5C-45CF-8524-6DFFB4193D1B",
"versionEndExcluding": "1.0.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:1.0.3:-:*:*:*:*:*:*",
"matchCriteriaId": "532C5C8D-3AC4-4596-8D8C-6855686BD92A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr205:-:*:*:*:*:*:*:*",
"matchCriteriaId": "56799602-9EF3-47D5-86CC-9AA2AE3013CF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6952617F-CF3F-4EB4-89B3-0C7076EEEEBC",
"versionEndExcluding": "1.2.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:1.2.5:-:*:*:*:*:*:*",
"matchCriteriaId": "5FDFE511-0244-454D-8D3F-C7E46D499FC5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr307-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2559CDDD-2C81-49A8-BF42-B3F6AC68F5F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An arbitrary OS command may be executed on the product by a remote unauthenticated attacker."
},
{
"lang": "es",
"value": "Un comando arbitrario del SO puede ser ejecutado en el producto por un atacante remoto no autenticado."
}
],
"id": "CVE-2025-6542",
"lastModified": "2026-10-18T21:10:00.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-6542",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:14:50.370895Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-10-21T01:15:37.063",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://support.omadanetworks.com/en/document/108455/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-7851
Vulnerability from fkie_nvd - Published: 2025-10-21 01:15 - Updated: 2026-10-18 21:10
Severity
Summary
An attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | fr307-m2_firmware | * | |
| tp-link | fr307-m2_firmware | 1.2.5 | |
| tp-link | fr307-m2 | - | |
| tp-link | fr205_firmware | * | |
| tp-link | fr205_firmware | 1.0.3 | |
| tp-link | fr205 | - | |
| tp-link | fr365_firmware | * | |
| tp-link | fr365_firmware | 1.1.10 | |
| tp-link | fr365 | - | |
| tp-link | g611_firmware | * | |
| tp-link | g611_firmware | 1.2.2 | |
| tp-link | g611 | - | |
| tp-link | g36_firmware | * | |
| tp-link | g36_firmware | 1.1.4 | |
| tp-link | g36 | - | |
| tp-link | er7212pc_firmware | * | |
| tp-link | er7212pc_firmware | 2.1.3 | |
| tp-link | er7212pc | - | |
| tp-link | er706w-4g_firmware | * | |
| tp-link | er706w-4g_firmware | 1.2.1 | |
| tp-link | er706w-4g | - | |
| tp-link | er706w_firmware | * | |
| tp-link | er706w_firmware | 1.2.1 | |
| tp-link | er706w | - | |
| tp-link | er605_firmware | * | |
| tp-link | er605_firmware | 2.3.1 | |
| tp-link | er605 | - | |
| tp-link | er7206_firmware | * | |
| tp-link | er7206_firmware | 2.2.2 | |
| tp-link | er7206 | - | |
| tp-link | er707-m2_firmware | * | |
| tp-link | er707-m2_firmware | 1.3.1 | |
| tp-link | er707-m2 | - | |
| tp-link | er7412-m2_firmware | * | |
| tp-link | er7412-m2_firmware | 1.1.0 | |
| tp-link | er7412-m2 | - | |
| tp-link | er8411_firmware | * | |
| tp-link | er8411_firmware | 1.3.3 | |
| tp-link | er8411 | - |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6952617F-CF3F-4EB4-89B3-0C7076EEEEBC",
"versionEndExcluding": "1.2.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:1.2.5:-:*:*:*:*:*:*",
"matchCriteriaId": "5FDFE511-0244-454D-8D3F-C7E46D499FC5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr307-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2559CDDD-2C81-49A8-BF42-B3F6AC68F5F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7FC1549-BC5C-45CF-8524-6DFFB4193D1B",
"versionEndExcluding": "1.0.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:1.0.3:-:*:*:*:*:*:*",
"matchCriteriaId": "532C5C8D-3AC4-4596-8D8C-6855686BD92A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr205:-:*:*:*:*:*:*:*",
"matchCriteriaId": "56799602-9EF3-47D5-86CC-9AA2AE3013CF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D38B9DBD-3397-40B8-B4A5-C1E0C248C300",
"versionEndExcluding": "1.1.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:1.1.10:-:*:*:*:*:*:*",
"matchCriteriaId": "4DA30139-EBED-40FD-BA20-CED14607B648",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr365:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFB3D95C-C64A-48A6-8D13-E158CFB3CC7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E6F8E98F-0C86-40C0-BBD3-D2B1889BAA87",
"versionEndExcluding": "1.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:1.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "5FF584E3-70F0-4B05-857B-CE07D87BA130",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g611:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D4BA74E1-BDA0-4FDD-820A-8DE32EEE2AA7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EB884461-7A80-44B0-A200-25D7E0EB5152",
"versionEndExcluding": "1.1.4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:1.1.4:-:*:*:*:*:*:*",
"matchCriteriaId": "BDA7D066-8443-4D6F-8E22-A0845236B490",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g36:-:*:*:*:*:*:*:*",
"matchCriteriaId": "153073B7-9FBD-47D0-A1AB-CEE323AE5512",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6CE877B8-E287-4FE6-84D5-666FE27AC9A6",
"versionEndExcluding": "2.1.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:2.1.3:-:*:*:*:*:*:*",
"matchCriteriaId": "24860FF1-7CA9-47D4-90B6-CB8915F1D992",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F300A161-E1A3-469E-9DE3-9B052F6BA8AC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E1BC6D9F-A556-468A-8770-6A39F09F26D6",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "96944BD2-388F-4CF6-BFD3-473EE6624F74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47273FE0-6E22-437E-B27F-058456E7602A",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "AC30DFD7-30FD-482C-B8EF-9DDB98E269BF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8EA51B29-39FB-4880-979B-3F612DE9D202",
"versionEndExcluding": "2.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:2.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "1D1D1C14-E0F9-430D-BAC5-4F0C7287FD26",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9892BC7C-6EA7-469B-AD26-6E5093DB5AB2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF595A8A-72CF-406E-BB0C-B76FDD51150B",
"versionEndExcluding": "2.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:2.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "8F66B05E-0D03-4B59-BCA3-7A2F40F092EE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB65324D-FD72-4C28-92AF-85BFF1E8A993",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48EDBC5B-BA54-4D11-9391-4FA7C7D4F5E7",
"versionEndExcluding": "1.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:1.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "359ADA2C-F1A5-4840-8F84-2DBA8F4573C4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14CE8275-E546-4598-901C-F52355DED3C9",
"versionEndExcluding": "1.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:1.1.0:-:*:*:*:*:*:*",
"matchCriteriaId": "B79E0763-6D6F-4E59-91FC-D397A8BEF0F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE0D8327-33EE-4EF0-BC2F-F2A16D55762A",
"versionEndExcluding": "1.3.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:1.3.3:-:*:*:*:*:*:*",
"matchCriteriaId": "6DB13EF6-0930-4575-92DC-AF431B2A2CEF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways."
},
{
"lang": "es",
"value": "Un atacante puede obtener el shell de root en el sistema operativo subyacente con las condiciones restringidas en los gateways Omada."
}
],
"id": "CVE-2025-7851",
"lastModified": "2026-10-18T21:10:00.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-7851",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:07:19.825502Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-10-21T01:15:37.330",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://support.omadanetworks.com/en/document/108456/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"url": "https://www.forescout.com/blog/new-tp-link-router-vulnerabilities-a-primer-on-rooting-routers/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-6541
Vulnerability from fkie_nvd - Published: 2025-10-21 01:15 - Updated: 2026-10-18 21:10
Severity
Summary
An arbitrary OS command may be executed on the product by the user who can log in to the web management interface.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | er706w_firmware | * | |
| tp-link | er706w_firmware | 1.2.1 | |
| tp-link | er706w | - | |
| tp-link | er706w-4g_firmware | * | |
| tp-link | er706w-4g_firmware | 1.2.1 | |
| tp-link | er706w-4g | - | |
| tp-link | er7212pc_firmware | * | |
| tp-link | er7212pc_firmware | 2.1.3 | |
| tp-link | er7212pc | - | |
| tp-link | g36_firmware | * | |
| tp-link | g36_firmware | 1.1.4 | |
| tp-link | g36 | - | |
| tp-link | g611_firmware | * | |
| tp-link | g611_firmware | 1.2.2 | |
| tp-link | g611 | - | |
| tp-link | fr365_firmware | * | |
| tp-link | fr365_firmware | 1.1.10 | |
| tp-link | fr365 | - | |
| tp-link | fr205_firmware | * | |
| tp-link | fr205_firmware | 1.0.3 | |
| tp-link | fr205 | - | |
| tp-link | fr307-m2_firmware | * | |
| tp-link | fr307-m2_firmware | 1.2.5 | |
| tp-link | fr307-m2 | - | |
| tp-link | er8411_firmware | * | |
| tp-link | er8411_firmware | 1.3.3 | |
| tp-link | er8411 | - | |
| tp-link | er7412-m2_firmware | * | |
| tp-link | er7412-m2_firmware | 1.1.0 | |
| tp-link | er7412-m2 | - | |
| tp-link | er707-m2_firmware | * | |
| tp-link | er707-m2_firmware | 1.3.1 | |
| tp-link | er707-m2 | - | |
| tp-link | er7206_firmware | * | |
| tp-link | er7206_firmware | 2.2.2 | |
| tp-link | er7206 | - | |
| tp-link | er605_firmware | * | |
| tp-link | er605_firmware | 2.3.1 | |
| tp-link | er605 | - |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47273FE0-6E22-437E-B27F-058456E7602A",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "AC30DFD7-30FD-482C-B8EF-9DDB98E269BF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E1BC6D9F-A556-468A-8770-6A39F09F26D6",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "96944BD2-388F-4CF6-BFD3-473EE6624F74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6CE877B8-E287-4FE6-84D5-666FE27AC9A6",
"versionEndExcluding": "2.1.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:2.1.3:-:*:*:*:*:*:*",
"matchCriteriaId": "24860FF1-7CA9-47D4-90B6-CB8915F1D992",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F300A161-E1A3-469E-9DE3-9B052F6BA8AC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EB884461-7A80-44B0-A200-25D7E0EB5152",
"versionEndExcluding": "1.1.4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:1.1.4:-:*:*:*:*:*:*",
"matchCriteriaId": "BDA7D066-8443-4D6F-8E22-A0845236B490",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g36:-:*:*:*:*:*:*:*",
"matchCriteriaId": "153073B7-9FBD-47D0-A1AB-CEE323AE5512",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E6F8E98F-0C86-40C0-BBD3-D2B1889BAA87",
"versionEndExcluding": "1.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:1.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "5FF584E3-70F0-4B05-857B-CE07D87BA130",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g611:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D4BA74E1-BDA0-4FDD-820A-8DE32EEE2AA7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D38B9DBD-3397-40B8-B4A5-C1E0C248C300",
"versionEndExcluding": "1.1.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:1.1.10:-:*:*:*:*:*:*",
"matchCriteriaId": "4DA30139-EBED-40FD-BA20-CED14607B648",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr365:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFB3D95C-C64A-48A6-8D13-E158CFB3CC7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7FC1549-BC5C-45CF-8524-6DFFB4193D1B",
"versionEndExcluding": "1.0.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:1.0.3:-:*:*:*:*:*:*",
"matchCriteriaId": "532C5C8D-3AC4-4596-8D8C-6855686BD92A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr205:-:*:*:*:*:*:*:*",
"matchCriteriaId": "56799602-9EF3-47D5-86CC-9AA2AE3013CF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6952617F-CF3F-4EB4-89B3-0C7076EEEEBC",
"versionEndExcluding": "1.2.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:1.2.5:-:*:*:*:*:*:*",
"matchCriteriaId": "5FDFE511-0244-454D-8D3F-C7E46D499FC5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr307-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2559CDDD-2C81-49A8-BF42-B3F6AC68F5F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE0D8327-33EE-4EF0-BC2F-F2A16D55762A",
"versionEndExcluding": "1.3.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:1.3.3:-:*:*:*:*:*:*",
"matchCriteriaId": "6DB13EF6-0930-4575-92DC-AF431B2A2CEF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14CE8275-E546-4598-901C-F52355DED3C9",
"versionEndExcluding": "1.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:1.1.0:-:*:*:*:*:*:*",
"matchCriteriaId": "B79E0763-6D6F-4E59-91FC-D397A8BEF0F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48EDBC5B-BA54-4D11-9391-4FA7C7D4F5E7",
"versionEndExcluding": "1.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:1.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "359ADA2C-F1A5-4840-8F84-2DBA8F4573C4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF595A8A-72CF-406E-BB0C-B76FDD51150B",
"versionEndExcluding": "2.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:2.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "8F66B05E-0D03-4B59-BCA3-7A2F40F092EE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB65324D-FD72-4C28-92AF-85BFF1E8A993",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8EA51B29-39FB-4880-979B-3F612DE9D202",
"versionEndExcluding": "2.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:2.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "1D1D1C14-E0F9-430D-BAC5-4F0C7287FD26",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9892BC7C-6EA7-469B-AD26-6E5093DB5AB2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An arbitrary OS command may be executed on the product by the user who can log in to the web management interface."
},
{
"lang": "es",
"value": "Un comando arbitrario del sistema operativo puede ser ejecutado en el producto por el usuario que puede iniciar sesi\u00f3n en la interfaz de gesti\u00f3n web."
}
],
"id": "CVE-2025-6541",
"lastModified": "2026-10-18T21:10:00.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-6541",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T13:56:36.534414Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-10-21T01:15:36.103",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://support.omadanetworks.com/en/document/108455/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-7850
Vulnerability from fkie_nvd - Published: 2025-10-21 01:15 - Updated: 2026-10-18 21:10
Severity
Summary
A command injection vulnerability may be exploited after the admin's authentication on the web portal on Omada gateways.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | er8411_firmware | * | |
| tp-link | er8411_firmware | 1.3.3 | |
| tp-link | er8411 | - | |
| tp-link | er7412-m2_firmware | * | |
| tp-link | er7412-m2_firmware | 1.1.0 | |
| tp-link | er7412-m2 | - | |
| tp-link | er707-m2_firmware | * | |
| tp-link | er707-m2_firmware | 1.3.1 | |
| tp-link | er707-m2 | - | |
| tp-link | er7206_firmware | * | |
| tp-link | er7206_firmware | 2.2.2 | |
| tp-link | er7206 | - | |
| tp-link | er605_firmware | * | |
| tp-link | er605_firmware | 2.3.1 | |
| tp-link | er605 | - | |
| tp-link | er706w_firmware | * | |
| tp-link | er706w_firmware | 1.2.1 | |
| tp-link | er706w | - | |
| tp-link | er706w-4g_firmware | * | |
| tp-link | er706w-4g_firmware | 1.2.1 | |
| tp-link | er706w-4g | - | |
| tp-link | er7212pc_firmware | * | |
| tp-link | er7212pc_firmware | 2.1.3 | |
| tp-link | er7212pc | - | |
| tp-link | g36_firmware | * | |
| tp-link | g36_firmware | 1.1.4 | |
| tp-link | g36 | - | |
| tp-link | g611_firmware | * | |
| tp-link | g611_firmware | 1.2.2 | |
| tp-link | g611 | - | |
| tp-link | fr365_firmware | * | |
| tp-link | fr365_firmware | 1.1.10 | |
| tp-link | fr365 | - | |
| tp-link | fr205_firmware | * | |
| tp-link | fr205_firmware | 1.0.3 | |
| tp-link | fr205 | - | |
| tp-link | fr307-m2_firmware | * | |
| tp-link | fr307-m2_firmware | 1.2.5 | |
| tp-link | fr307-m2 | - |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE0D8327-33EE-4EF0-BC2F-F2A16D55762A",
"versionEndExcluding": "1.3.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:1.3.3:-:*:*:*:*:*:*",
"matchCriteriaId": "6DB13EF6-0930-4575-92DC-AF431B2A2CEF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14CE8275-E546-4598-901C-F52355DED3C9",
"versionEndExcluding": "1.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:1.1.0:-:*:*:*:*:*:*",
"matchCriteriaId": "B79E0763-6D6F-4E59-91FC-D397A8BEF0F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48EDBC5B-BA54-4D11-9391-4FA7C7D4F5E7",
"versionEndExcluding": "1.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:1.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "359ADA2C-F1A5-4840-8F84-2DBA8F4573C4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF595A8A-72CF-406E-BB0C-B76FDD51150B",
"versionEndExcluding": "2.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:2.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "8F66B05E-0D03-4B59-BCA3-7A2F40F092EE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB65324D-FD72-4C28-92AF-85BFF1E8A993",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8EA51B29-39FB-4880-979B-3F612DE9D202",
"versionEndExcluding": "2.3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:2.3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "1D1D1C14-E0F9-430D-BAC5-4F0C7287FD26",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9892BC7C-6EA7-469B-AD26-6E5093DB5AB2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47273FE0-6E22-437E-B27F-058456E7602A",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "AC30DFD7-30FD-482C-B8EF-9DDB98E269BF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E1BC6D9F-A556-468A-8770-6A39F09F26D6",
"versionEndExcluding": "1.2.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:1.2.1:-:*:*:*:*:*:*",
"matchCriteriaId": "96944BD2-388F-4CF6-BFD3-473EE6624F74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6CE877B8-E287-4FE6-84D5-666FE27AC9A6",
"versionEndExcluding": "2.1.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:2.1.3:-:*:*:*:*:*:*",
"matchCriteriaId": "24860FF1-7CA9-47D4-90B6-CB8915F1D992",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F300A161-E1A3-469E-9DE3-9B052F6BA8AC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EB884461-7A80-44B0-A200-25D7E0EB5152",
"versionEndExcluding": "1.1.4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g36_firmware:1.1.4:-:*:*:*:*:*:*",
"matchCriteriaId": "BDA7D066-8443-4D6F-8E22-A0845236B490",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g36:-:*:*:*:*:*:*:*",
"matchCriteriaId": "153073B7-9FBD-47D0-A1AB-CEE323AE5512",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E6F8E98F-0C86-40C0-BBD3-D2B1889BAA87",
"versionEndExcluding": "1.2.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:g611_firmware:1.2.2:-:*:*:*:*:*:*",
"matchCriteriaId": "5FF584E3-70F0-4B05-857B-CE07D87BA130",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g611:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D4BA74E1-BDA0-4FDD-820A-8DE32EEE2AA7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D38B9DBD-3397-40B8-B4A5-C1E0C248C300",
"versionEndExcluding": "1.1.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:1.1.10:-:*:*:*:*:*:*",
"matchCriteriaId": "4DA30139-EBED-40FD-BA20-CED14607B648",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr365:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFB3D95C-C64A-48A6-8D13-E158CFB3CC7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7FC1549-BC5C-45CF-8524-6DFFB4193D1B",
"versionEndExcluding": "1.0.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr205_firmware:1.0.3:-:*:*:*:*:*:*",
"matchCriteriaId": "532C5C8D-3AC4-4596-8D8C-6855686BD92A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr205:-:*:*:*:*:*:*:*",
"matchCriteriaId": "56799602-9EF3-47D5-86CC-9AA2AE3013CF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6952617F-CF3F-4EB4-89B3-0C7076EEEEBC",
"versionEndExcluding": "1.2.5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tp-link:fr307-m2_firmware:1.2.5:-:*:*:*:*:*:*",
"matchCriteriaId": "5FDFE511-0244-454D-8D3F-C7E46D499FC5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr307-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2559CDDD-2C81-49A8-BF42-B3F6AC68F5F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A command injection vulnerability may be exploited after the admin\u0027s authentication on the web portal on Omada gateways."
},
{
"lang": "es",
"value": "Una vulnerabilidad de inyecci\u00f3n de comandos puede ser explotada despu\u00e9s de la autenticaci\u00f3n del administrador en el portal web en los gateways Omada."
}
],
"id": "CVE-2025-7850",
"lastModified": "2026-10-18T21:10:00.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-7850",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:09:38.276316Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-10-21T01:15:37.193",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://support.omadanetworks.com/en/document/108456/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"url": "https://www.forescout.com/blog/new-tp-link-router-vulnerabilities-a-primer-on-rooting-routers/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-9290
Vulnerability from fkie_nvd - Published: 2026-01-23 00:15 - Updated: 2026-10-07 00:17
Severity
Summary
An authentication weakness was identified in Omada Controllers, Gateways and Access Points, controller-device adoption due to improper handling of random values. Exploitation requires advanced network positioning and allows an attacker to intercept adoption traffic and forge valid authentication through offline precomputation, potentially exposing sensitive information and compromising confidentiality.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows",
"Linux"
],
"product": "Omada Software Controller",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "6.0.0.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Cloud Controller",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "6.0.0.100",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Hardware Controller (OC200, OC300, OC400)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "6.0.0.34",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Hardware Controller OC220",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "5.15.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER605 v2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.2 Build 20251029 Rel.12727",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER7206 v2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.2.2 Build 20250724 Rel.11109",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER7406, ER706W, ER706-4G)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.x",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER707-M2, ER-8411)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.3.x",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER7412-M2, ER706WP-4G, ER703WP-4G-Outdoor, DR3220v-4G, DR3650v, DR3650v-4G)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER8411)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.3.5 Build 20251028 Rel.06811",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER706W-4G 2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0 Build 20250810 Rel.77020",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER701-5G-Outdoor)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.0 Build 20250826 Rel.68862",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER605W 2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.2 Build 20250723 Rel.39048",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway ER7212PC 2.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.2.1 Build 20251027 Rel.75129",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Festa Gateway FR365",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.10 Build 20250626 Rel.81746",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway G36W-4G",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.5 Build 20250710 Rel.62142",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP660 HD v1.0/v2.0, EAP620 HD v2.0/v3.0/v3.20, EAP610/EAP610-Outdoor v1.0/v2.0, EAP623-Outdoor HD v1.0, EAP625-Outdoor HD v1.0)EAP",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.6.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP655-Wall v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.6.2 Build 20251107 Rel.35700",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP772 v1.0, EAP773 v1.0, EAP783 v1.0, EAP787 v1.0, EAP720 v1.0, EAP725-Wall v1.0, EAp723 v2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP723 v1.0, EAP772 v2.0, EAP772-Outdoor v 1.0, EAP770 v2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.3.2 Build 20250901 Rel.52255",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP215 Bridge KIT 3.0, EAP211 Bridge KIT 3.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.4 Build 20251112 Rel.34769",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Beam Bridge 5 UR v1.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.5 Build 20250928 Rel.68499",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP603GP-Desktop, EAP615GP-Wall 1.20, EAP625GP-Wall 1.0/1.20, EAP610GP-Desktop 1.0/1.20/1.26), EAP650-Desktop v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP650GP-Desktop 1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20250819 Rel.60298",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP653 v1.0, EAP650-Outdoor v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.3.3 Build 20251111 Rel.72627",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP230-Wall v1.0, EAP235-Wall v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "3.3.1 Build 20251203 Rel.58135",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP603-Outdoor v1.0, EAP615-Wall v1.0/v1.20)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.5.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP653 UR v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.2 Build 20251208 Rel.43830",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP615-Wall v1.0/v1.20)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.5.10 Build 20250903 Rel.49784",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada EAP100-Bridge KIT v1.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20251015 Rel.62058",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:tp-link:omada_controller:*:*:*:*:-:*:*:*",
"matchCriteriaId": "3B623F6F-B033-44B4-9F50-97CE3C0F84E1",
"versionEndExcluding": "6.0.0.24",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:tp-link:omada_controller:*:*:*:*:cloud:*:*:*",
"matchCriteriaId": "DB01AAAF-90A1-4DA2-8810-D5A02D11ABCC",
"versionEndExcluding": "6.0.0.100",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:oc200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "036DEE09-EB29-4F38-A472-181FE88A1EAC",
"versionEndExcluding": "1.37.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:oc200:1:*:*:*:*:*:*:*",
"matchCriteriaId": "D994D0D1-FE36-4CB9-A641-CAAC8D643783",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:oc220_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EBEF0143-6106-468B-BAED-F2FEDDA4F4D8",
"versionEndExcluding": "1.1.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:oc220:1:*:*:*:*:*:*:*",
"matchCriteriaId": "077DD2BF-32E3-434E-B040-9B4C48F419CA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:oc300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1188840C-7B7B-4D07-A4D4-DED7D02E2971",
"versionEndExcluding": "1.31.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:oc300:1.6:*:*:*:*:*:*:*",
"matchCriteriaId": "8E90417C-17A3-4D55-9764-4EF93D19B610",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:oc400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5B04AEC9-E614-4C99-98B5-568D845C3153",
"versionEndExcluding": "1.9.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:oc400:1.6:*:*:*:*:*:*:*",
"matchCriteriaId": "15655343-B8B7-4C17-8F9B-E90823407861",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:oc200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4F791A1D-CF64-44C9-B17C-FF8632E3B6BF",
"versionEndExcluding": "2.22.9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:oc200:2:*:*:*:*:*:*:*",
"matchCriteriaId": "86D6AE05-E5BE-41A6-B3ED-16C5B15BF2A2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:oc220_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A57FF3FD-0CEF-4999-9FAB-CBDEB6DEB72C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:oc220:2:*:*:*:*:*:*:*",
"matchCriteriaId": "3B92B1CF-71F7-4833-BE9E-DE8A6F914DC0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C8FEB440-CE78-4049-973D-389C3344F16A",
"versionEndExcluding": "2.3.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "11B180B7-7FE9-4971-9F1A-9FD2A73FA9C3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7206_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF595A8A-72CF-406E-BB0C-B76FDD51150B",
"versionEndExcluding": "2.2.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7206:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "4B8866B3-837C-47E0-94DD-CE771083CCD6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7406_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EF1485B3-EAA6-4FF2-B74F-03F25EE1C3B6",
"versionEndExcluding": "1.2.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7406:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3064CDE7-9329-4D22-8853-B4EE6D050D4B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er707-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48EDBC5B-BA54-4D11-9391-4FA7C7D4F5E7",
"versionEndExcluding": "1.3.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er707-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E45AF81F-1346-4FD8-9E38-CAB330D79AB6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7412-m2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "14CE8275-E546-4598-901C-F52355DED3C9",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7412-m2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBB89DAE-6264-4F26-B34A-E1B84FB927D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er8411_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7F401B17-FA22-42FD-B8FD-E35CC537AAB6",
"versionEndExcluding": "1.3.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er8411:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2F16D8-5D7B-4E01-8BB3-F324B6011F72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47273FE0-6E22-437E-B27F-058456E7602A",
"versionEndExcluding": "1.2.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D599C4B-4A58-45EC-BA17-332FBF6E9805",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E1BC6D9F-A556-468A-8770-6A39F09F26D6",
"versionEndExcluding": "1.2.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "559FA8D2-3055-41CB-81A4-A7996D93588D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706wp-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C4901A66-199A-49CD-A3D7-CD914D0BD7E6",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706wp-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDF76B4C-3657-4C55-AC76-A31FC5A988A8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er703wp-4g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7C91F4E8-8D0E-440A-8B26-41DF45D6607F",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er703wp-4g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9984C375-4F11-4C3A-AB3D-9A23C4B9EE77",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3220v-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "33E52E83-05FC-4577-A7C4-8A525FC404F0",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3220v-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CAA74D58-481A-40B3-BEC7-AD1782802C51",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3650v-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5D7C9714-1A94-4E99-8D46-625F58E7CECF",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3650v-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "121CBA17-EB12-4611-B05B-A39C8DE06410",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:dr3650v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1616C0E5-4342-4E2F-91C9-0D3C931D28D6",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:dr3650v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CD34FB5F-D4EA-41E3-B625-78A8045AC916",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er701-5g-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C97069D2-AD05-4D72-9979-C62874416705",
"versionEndExcluding": "1.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er701-5g-outdoor:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2082ECC6-BC83-4D1A-A9E3-D8F3215D43E1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er605w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8FB2EABE-2535-4CCB-A33F-F7A98A539775",
"versionEndExcluding": "2.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er605w:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "5AE8F6F3-D20F-4151-9BEA-F3BF930A9060",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er7212pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "343DD4B4-412D-4EDA-B4BE-2B093DCAF673",
"versionEndExcluding": "2.2.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er7212pc:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "939EE8A4-1CA6-495C-83B0-369B4367A402",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:fr365_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D38B9DBD-3397-40B8-B4A5-C1E0C248C300",
"versionEndExcluding": "1.1.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:fr365:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFB3D95C-C64A-48A6-8D13-E158CFB3CC7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:g36w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6FC4816C-9B91-469D-B9CC-3EB035CC22B5",
"versionEndExcluding": "1.1.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:g36w-4g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F7F61184-DD0F-422F-A06C-E770B0864808",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap655-wall_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D7CD091C-C66E-482B-B12D-B1B204B89863",
"versionEndExcluding": "1.6.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap655-wall:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "991B3213-D888-4FC3-8674-8EF32A3E43BB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap660_hd_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "29540BAE-EA7E-4C34-911C-A6C48834213E",
"versionEndExcluding": "1.6.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap660_hd:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "C36753B9-2F82-422D-9494-3103D42B1627",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:tp-link:eap660_hd:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DDE928DD-D6DB-48F0-A210-62E3B390E943",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap620_hd_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9B3ECEBB-9E53-4FAD-9080-457FEDB26DE7",
"versionEndExcluding": "1.6.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap620_hd:3.0:*:*:*:*:*:*:*",
"matchCriteriaId": "3594AE8D-23A4-4AD2-BDE7-D528E767E721",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:tp-link:eap620_hd:3.20:*:*:*:*:*:*:*",
"matchCriteriaId": "02B7834A-1096-4C0E-B1FE-2E67F4541F5C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap610-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B982BA88-24A5-4E86-938D-494D7DC3FFE3",
"versionEndExcluding": "1.6.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap610-outdoor:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "1CEA1A5A-FF50-483E-A940-5871F471E576",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:tp-link:eap610-outdoor:1.20:*:*:*:*:*:*:*",
"matchCriteriaId": "642BCE38-3F3C-4526-9689-8DEBEEE67CBB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap610_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7AEEE687-D5A3-4F9D-B123-EDE7F7EA78B8",
"versionEndExcluding": "1.6.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap610:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "1D622F57-4F1C-45B5-A5AB-AEE5BD966DA6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:tp-link:eap610:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "91F00BE0-DA73-4111-8FD7-56415602A9D5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap623-outdoor_hd_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1C86152-9506-47A7-9E04-CB44E049065B",
"versionEndExcluding": "1.6.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap623-outdoor_hd:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "73D823C4-E53F-45B6-8113-0296D807AEAF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap625-outdoor_hd_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6A3D423B-73F2-4CD5-BA6B-EE0686FBA3E1",
"versionEndExcluding": "1.6.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap625-outdoor_hd:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "220A7284-B7B0-4F9B-87CE-4C34C97D5FC0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap772_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BE730B6A-5018-4DF8-9E9C-2DCBE179658A",
"versionEndExcluding": "1.3.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap772:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "C6C119B9-AF17-4E30-BDF0-A5AC6D571A3E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap772-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FB420727-461E-4CD5-8883-E00E6C8C5AA5",
"versionEndExcluding": "1.3.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap772-outdoor:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "06AFD633-F439-447A-A495-830BE6AFF5DE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap770_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "362060E8-4C1E-43D7-91D7-116E9144C485",
"versionEndExcluding": "1.3.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap770:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "165538BB-DB64-455F-A92B-7322A1900B41",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap723_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACF9B776-5756-453D-8224-EDDDF7113E9B",
"versionEndExcluding": "1.3.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap723:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "52985636-B6D6-476B-9AA3-D84D7DC1B2F5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap773_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "96E8198A-61A7-43C8-8000-197883114066",
"versionEndExcluding": "1.1.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap773:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "62C1CE1F-458E-4F41-AE4F-E8D22C246499",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap783_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1FFFA0FD-0F26-4C3C-A559-E20C1FC3D55F",
"versionEndExcluding": "1.1.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap783:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "C458401A-AD3B-4E28-905C-4BEEEABF9138",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap772_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F0064A29-C3E0-4471-86CB-F7C38B94F429",
"versionEndExcluding": "1.1.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap772:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "D211DAED-EDAD-457A-95B3-8282D0C3D145",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap787_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56E16E4A-7705-4154-BD36-CAAEF45550ED",
"versionEndExcluding": "1.1.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap787:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "FB4D1955-75DE-438B-89CE-1C1E4ADF6A93",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap720_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "732D7357-1F6E-4A08-A10E-C7DC04F423AC",
"versionEndExcluding": "1.1.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap720:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "FEFEBBB9-27BB-4228-95D1-007451659D15",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap723_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F6C50AE2-F6EF-423A-9C77-5D8EAC3A8BE1",
"versionEndExcluding": "1.1.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap723:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "C3492865-EBDD-43D8-B826-94254723DA14",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap725-wall_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "06A5A307-EE80-4B6D-B622-9891DB2D90CA",
"versionEndExcluding": "1.1.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap725-wall:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "CB708AE3-FEAD-47E1-8DBA-AB0DD7AF525F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap215_bridge_kit_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF314DDD-12AD-474D-AC55-B07071682620",
"versionEndExcluding": "1.1.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap215_bridge_kit:3.0:*:*:*:*:*:*:*",
"matchCriteriaId": "D8804436-64F2-4D7B-92E3-E2664F7FFCB0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap211_bridge_kit_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "76D7B3DC-D4CC-48B3-BBD7-1DEF6BCF9E7A",
"versionEndExcluding": "1.1.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap211_bridge_kit:3.0:*:*:*:*:*:*:*",
"matchCriteriaId": "03EBB9F1-7FC4-4AC3-97FF-47BEA15090DF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:beam_bridge_5_ur_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D227C16B-0F43-4122-81C7-1EEFA88FEB08",
"versionEndExcluding": "1.1.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:beam_bridge_5_ur:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "6898729A-B955-406B-B63B-899E196DC215",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap603gp-desktop_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DDA67672-1BFE-41C7-924D-EE0165585170",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap603gp-desktop:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "33FC3D07-F6A3-49C1-B4AF-D9A9F15CEE42",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap615gp-wall_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FEB2FC9A-F89E-483B-B4BF-840C6E3A1AC1",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap615gp-wall:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "8ACB30C0-C60E-4F77-88D3-C266F6CF375E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:tp-link:eap615gp-wall:1.20:*:*:*:*:*:*:*",
"matchCriteriaId": "6D4516EB-C994-47AA-A707-2DDF3EF98486",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap625gp-wall_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AF5E03EC-EB4E-4F49-9CA6-0BB97CC42985",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap625gp-wall:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "B2C871E6-A453-4554-961C-96768A8BE0C9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:tp-link:eap625gp-wall:1.20:*:*:*:*:*:*:*",
"matchCriteriaId": "D8C35E79-3EB4-4A61-8ED9-33FC69F6014D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap610gp-desktop_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1FDDB0B3-4A7D-4BFA-BE19-FC3974C04F98",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap610gp-desktop:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "B2DF818D-3A58-48AA-B0E2-A405FC48334C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:tp-link:eap610gp-desktop:1.20:*:*:*:*:*:*:*",
"matchCriteriaId": "1453752B-1B6E-4D1D-940A-1C3BC66D35F1",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:tp-link:eap610gp-desktop:1.26:*:*:*:*:*:*:*",
"matchCriteriaId": "45FE7B43-714C-45B2-A00F-7862B8B5BEF0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap650gp-desktop_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5CDE0ACF-6940-4C31-991A-74E74EB2562F",
"versionEndExcluding": "1.0.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap650gp-desktop:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "C3846FDB-64C9-43AF-B4D9-829E33BC9F11",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap653_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D932E434-CF87-478D-B570-11DB0B5C0157",
"versionEndExcluding": "1.3.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap653:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "1315E2A2-3F2A-4DFE-9812-3DBC76AA5FC7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap650-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E9B753F6-8B47-4E21-B91F-91A80F1DF358",
"versionEndExcluding": "1.3.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap650-outdoor:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "77D3261D-A7B3-4173-9B01-BBEFEE335743",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap230-wall_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "38AEA9E4-CADB-4B08-8B12-3B261DB507C1",
"versionEndExcluding": "3.3.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap230-wall:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "614DB0C1-EA47-45EF-B776-37EA76EB206F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap235-wall_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "61BC4351-AFEE-477C-9F84-9B66189760FD",
"versionEndExcluding": "3.3.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap235-wall:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "276C9B86-BD45-464D-BE06-8B729A0367D0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap603-outdoor_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "59B6FC43-E0EA-4B14-B196-8BDC94A05906",
"versionEndExcluding": "1.5.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap603-outdoor:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "FC92FD7F-57D5-4198-A307-7E6A5829191A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap653_ur_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "89BA334E-D089-45C4-8A6E-F75AD51CDAF5",
"versionEndExcluding": "1.4.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap653_ur:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "037EBA68-4F8C-41DC-8269-9F85893A2EB5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap650-desktop_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4BC73594-70AD-4D51-99E4-EC09CC9113D1",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap650-desktop:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "14DFF4A6-3398-4B41-90A3-EA4C73ACEAB7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap615-wall_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EBFBD22C-EA74-4116-AE86-0C443F9A08B0",
"versionEndExcluding": "1.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap615-wall:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "5214370A-DB8E-430A-9DF1-99C9822E9256",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:eap100-bridge_kit_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BF37790D-C065-40AF-A350-15BDE985332D",
"versionEndExcluding": "1.0.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:eap100-bridge_kit:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "8D5C2F8A-2EDA-42A1-99E7-5154C1E72DC7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:er706w-4g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "329942F9-1FE5-4BCB-A5D4-4B691E5D8772",
"versionEndExcluding": "2.1.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:er706w-4g:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DE1504A8-4FDC-44E0-9C97-2AC838DC4FBF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:tp-link:omada_controller:*:*:*:*:-:*:*:*",
"matchCriteriaId": "64544C00-6B20-4320-850B-B83F99D72BC6",
"versionEndExcluding": "6.0.0.34",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:oc200:1:*:*:*:*:*:*:*",
"matchCriteriaId": "D994D0D1-FE36-4CB9-A641-CAAC8D643783",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:tp-link:oc200:2:*:*:*:*:*:*:*",
"matchCriteriaId": "86D6AE05-E5BE-41A6-B3ED-16C5B15BF2A2",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:tp-link:oc300:1.6:*:*:*:*:*:*:*",
"matchCriteriaId": "8E90417C-17A3-4D55-9764-4EF93D19B610",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:tp-link:oc400:1.6:*:*:*:*:*:*:*",
"matchCriteriaId": "15655343-B8B7-4C17-8F9B-E90823407861",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:tp-link:omada_controller:*:*:*:*:-:*:*:*",
"matchCriteriaId": "53E39C1E-DB6C-4F8C-97C2-30C4F2776256",
"versionEndExcluding": "5.15.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:oc220:1:*:*:*:*:*:*:*",
"matchCriteriaId": "077DD2BF-32E3-434E-B040-9B4C48F419CA",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:tp-link:oc220:2:*:*:*:*:*:*:*",
"matchCriteriaId": "3B92B1CF-71F7-4833-BE9E-DE8A6F914DC0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An authentication weakness was identified in Omada Controllers, Gateways and Access Points, controller-device adoption due to improper handling of random values. Exploitation requires advanced network positioning and allows an attacker to intercept adoption traffic and forge valid authentication through offline precomputation, potentially exposing sensitive information and compromising confidentiality."
},
{
"lang": "es",
"value": "Una debilidad de autenticaci\u00f3n fue identificada en los controladores Omada, gateways y puntos de acceso, en la adopci\u00f3n controlador-dispositivo debido a un manejo inadecuado de valores aleatorios. La explotaci\u00f3n requiere un posicionamiento de red avanzado y permite a un atacante interceptar el tr\u00e1fico de adopci\u00f3n y falsificar una autenticaci\u00f3n v\u00e1lida mediante precomputaci\u00f3n fuera de l\u00ednea, exponiendo potencialmente informaci\u00f3n sensible y comprometiendo la confidencialidad."
}
],
"id": "CVE-2025-9290",
"lastModified": "2026-10-07T00:17:19.853",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.0,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-9290",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-23T20:04:16.930287Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-01-23T00:15:52.093",
"references": [
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://support.omadanetworks.com/en/download/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Vendor Advisory"
],
"url": "https://support.omadanetworks.com/us/document/114950/"
},
{
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"tags": [
"Product"
],
"url": "https://support.omadanetworks.com/us/download/"
}
],
"sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-760"
}
],
"source": "f23511db-6c3e-4e32-a477-6aa17d310630",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2026-9033 (GCVE-0-2026-9033)
Vulnerability from nvd – Published: 2026-08-20 18:31 – Updated: 2026-08-20 18:59
VLAI
EPSS
VEX
Title
Unauthenticated Captive Portal Session Termination and Forced Logout in Omada Gateways
Summary
An unauthenticated attacker with network access to the captive portal service of an affected device can terminate active captive portal sessions, including forcing logout of specific users or clearing all active sessions. Affected users must re-authenticate to regain access.
Successful exploitation may allow termination of individual or all active captive portal sessions, causing temporary service disruption and requiring users to re-authenticate.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-20 18:59 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.omadanetworks.com/en/support/download/ | patch |
| https://www.omadanetworks.com/us/support/download/ | patch |
| https://www.tp-link.com/us/support/faq/5256/ | vendor-advisory |
Impacted products
19 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | ER7212PC v2 |
Affected:
0 , < 2.4.3 Build 20260722 Rel.40250
(custom)
|
|
| TP-Link Systems Inc. | ER605 v2 |
Affected:
0 , < 2.4.4 Build 20260630 Rel.14398
(custom)
|
|
| TP-Link Systems Inc. | ER7206 v2 |
Affected:
0 , < 2.3.5 Build 20260625 Rel.43136
(custom)
|
|
| TP-Link Systems Inc | ER7406 v1 |
Affected:
0 , < 1.3.4 Build 20260625 Rel.43136
(custom)
|
|
| TP-Link Systems Inc. | ER707-M2 v1 |
Affected:
0 , < 1.4.4 Build 20260625 Rel.43063
(custom)
|
|
| TP-Link Systems Inc | ER7412-M2 v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.82947
(custom)
|
|
| TP-Link Systems Inc. | ER8411 v1 |
Affected:
0 , < 1.4.1 Build 20260708 Rel.64832
(custom)
|
|
| TP-Link Systems Inc. | ER706W v1 |
Affected:
0 , < 1.2.11 Build 20260723 Rel.41567
(custom)
|
|
| TP-Link Systems Inc. | ER706W-4G v1 |
Affected:
0 , < 1.2.6 Build 20260723 Rel.41321
(custom)
|
|
| TP-Link Systems Inc. | ER706W-4G v2 |
Affected:
0 , < 2.1.11 Build 20260723 Rel.41624
(custom)
|
|
| TP-Link Systems Inc. | ER706WP-4G v1 |
Affected:
0 , < 1.1.11 Build 20260723 Rel.41624
(custom)
|
|
| TP-Link Systems Inc. | ER703WP-4G-Outdoor v1 |
Affected:
0 , < 1.1.7 Build 20260723 Rel.41712
(custom)
|
|
| TP-Link Systems Inc. | DR3220v-4G v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.82652
(custom)
|
|
| TP-Link Systems Inc. | DR3650v v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.83311
(custom)
|
|
| TP-Link Systems Inc. | DR3650v-4G v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.83347
(custom)
|
|
| TP-Link Systems Inc. | ER603WP-4G-Outdoor v1 |
Affected:
0 , < 1.0.2 Build 20260723 Rel.43271
(custom)
|
|
| TP-Link Systems Inc. | DR3150 v1 |
Affected:
0 , < 1.0.1 Build 20260722 Rel.16854
(custom)
|
|
| TP-Link Systems Inc. | ER701-5G-Outdoor v1 |
Affected:
0 , < 1.0.3 Build 20260723 Rel.40931
(custom)
|
|
| TP-Link Systems Inc. | ER605W v2 |
Affected:
0 , < 2.0.4 Build 20260723 Rel.43763
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9033",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T18:59:29.032581Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T18:59:36.657Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ER7212PC v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.3 Build 20260722 Rel.40250",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.4 Build 20260630 Rel.14398",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7206 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.5 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7406 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.3.4 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER707-M2 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.4 Build 20260625 Rel.43063",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7412-M2 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82947",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER8411 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.1 Build 20260708 Rel.64832",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.11 Build 20260723 Rel.41567",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.6 Build 20260723 Rel.41321",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706WP-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER703WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.7 Build 20260723 Rel.41712",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3220v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82652",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83311",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83347",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER603WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.2 Build 20260723 Rel.43271",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3150 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20260722 Rel.16854",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER701-5G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20260723 Rel.40931",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605W v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.4 Build 20260723 Rel.43763",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Yoontae Lee (@yunttai)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn unauthenticated attacker with network access to the captive portal service of an affected device can terminate active captive portal sessions, including forcing logout of specific users or clearing all active sessions. Affected users must re-authenticate to regain access.\u0026nbsp;\u003c/p\u003e\u003cp\u003eSuccessful exploitation may allow termination of individual or all active captive portal sessions, causing temporary service disruption and requiring users to re-authenticate.\u003c/p\u003e"
}
],
"value": "An unauthenticated attacker with network access to the captive portal service of an affected device can terminate active captive portal sessions, including forcing logout of specific users or clearing all active sessions. Affected users must re-authenticate to regain access.\u00a0\n\n\n\nSuccessful exploitation may allow termination of individual or all active captive portal sessions, causing temporary service disruption and requiring users to re-authenticate."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T18:31:54.806Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"name": "Omada Gateway Firmware Downloads (EN)",
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/en/support/download/"
},
{
"name": "Omada Gateway Firmware Downloads (US)",
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/us/support/download/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.tp-link.com/us/support/faq/5256/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthenticated Captive Portal Session Termination and Forced Logout in Omada Gateways",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2026-9033",
"datePublished": "2026-08-20T18:31:54.806Z",
"dateReserved": "2026-05-19T16:30:37.346Z",
"dateUpdated": "2026-08-20T18:59:36.657Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-19683 (GCVE-0-2026-19683)
Vulnerability from nvd – Published: 2026-08-20 18:32 – Updated: 2026-08-20 18:58
VLAI
EPSS
VEX
Title
Unencrypted Credential Transmission in Omada Gateway Dynamic DNS Authentication in Omada Gateways
Summary
A vulnerability exists in the Dynamic DNS (DDNS) functionality of TP-Link Omada Gateways. During communication with a third-party DDNS service, authentication credentials are transmitted over an unencrypted channel. An attacker who can observe or manipulate traffic between an affected device and the DDNS service may obtain sensitive authentication information or interfere with DDNS update operations. Exploitation requires DDNS to be configured, communication with an external DDNS service, and attacker visibility or control of the relevant network path.
Successful exploitation may result in disclosure of DDNS account credentials, unauthorized access to DDNS management functionality, or modification of DNS records associated with the affected deployment.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-20 18:55 UTC
CWE
- CWE-319 - Cleartext transmission of sensitive information
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.omadanetworks.com/en/support/download/ | patch |
| https://www.omadanetworks.com/us/support/download/ | patch |
| https://www.tp-link.com/us/support/faq/5256/ | vendor-advisory |
Impacted products
19 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | ER7212PC v2 |
Affected:
0 , < 2.4.3 Build 20260722 Rel.40250
(custom)
|
|
| TP-Link Systems Inc. | ER605 v2 |
Affected:
0 , < 2.4.4 Build 20260630 Rel.14398
(custom)
|
|
| TP-Link Systems Inc. | ER7206 v2 |
Affected:
0 , < 2.3.5 Build 20260625 Rel.43136
(custom)
|
|
| TP-Link Systems Inc | ER7406 v1 |
Affected:
0 , < 1.3.4 Build 20260625 Rel.43136
(custom)
|
|
| TP-Link Systems Inc. | ER707-M2 v1 |
Affected:
0 , < 1.4.4 Build 20260625 Rel.43063
(custom)
|
|
| TP-Link Systems Inc | ER7412-M2 v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.82947
(custom)
|
|
| TP-Link Systems Inc. | ER8411 v1 |
Affected:
0 , < 1.4.1 Build 20260708 Rel.64832
(custom)
|
|
| TP-Link Systems Inc. | ER706W v1 |
Affected:
0 , < 1.2.11 Build 20260723 Rel.41567
(custom)
|
|
| TP-Link Systems Inc. | v1 |
Affected:
0 , < 1.2.6 Build 20260723 Rel.41321
(custom)
|
|
| TP-Link Systems Inc. | ER706W-4G v2 |
Affected:
0 , < 2.1.11 Build 20260723 Rel.41624
(custom)
|
|
| TP-Link Systems Inc. | ER706WP-4G v1 |
Affected:
0 , < 1.1.11 Build 20260723 Rel.41624
(custom)
|
|
| TP-Link Systems Inc. | ER703WP-4G-Outdoor v1 |
Affected:
0 , < 1.1.7 Build 20260723 Rel.41712
(custom)
|
|
| TP-Link Systems Inc. | DR3220v-4G v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.82652
(custom)
|
|
| TP-Link Systems Inc. | DR3650v v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.83311
(custom)
|
|
| TP-Link Systems Inc. | DR3650v-4G v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.83347
(custom)
|
|
| TP-Link Systems Inc. | ER603WP-4G-Outdoor v1 |
Affected:
0 , < 1.0.2 Build 20260723 Rel.43271
(custom)
|
|
| TP-Link Systems Inc. | DR3150 v1 |
Affected:
0 , < 1.0.1 Build 20260722 Rel.16854
(custom)
|
|
| TP-Link Systems Inc. | ER701-5G-Outdoor v1 |
Affected:
0 , < 1.0.3 Build 20260723 Rel.40931
(custom)
|
|
| TP-Link Systems Inc. | ER605W v2 |
Affected:
0 , < 2.0.4 Build 20260723 Rel.43763
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-19683",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T18:55:44.295305Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T18:58:42.948Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ER7212PC v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.3 Build 20260722 Rel.40250",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.4 Build 20260630 Rel.14398",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7206 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.5 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7406 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.3.4 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER707-M2 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.4 Build 20260625 Rel.43063",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7412-M2 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82947",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER8411 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.1 Build 20260708 Rel.64832",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.11 Build 20260723 Rel.41567",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.6 Build 20260723 Rel.41321",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706WP-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER703WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.7 Build 20260723 Rel.41712",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3220v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82652",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83311",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83347",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER603WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.2 Build 20260723 Rel.43271",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3150 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20260722 Rel.16854",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER701-5G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20260723 Rel.40931",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605W v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.4 Build 20260723 Rel.43763",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cp\u003eA vulnerability exists in the Dynamic DNS (DDNS) functionality of TP-Link Omada Gateways. During communication with a third-party DDNS service, authentication credentials are transmitted over an unencrypted channel. An attacker who can\u0026nbsp;observe\u0026nbsp;or manipulate traffic between an affected device and the DDNS service may obtain sensitive authentication information or interfere with DDNS update operations. Exploitation requires DDNS to be configured, communication with an external DDNS service, and attacker visibility or control of the relevant network path.\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003eSuccessful exploitation may result in disclosure of DDNS account credentials, unauthorized access to DDNS management functionality, or modification of DNS records associated with the affected deployment.\u003c/p\u003e\u003c/div\u003e"
}
],
"value": "A vulnerability exists in the Dynamic DNS (DDNS) functionality of TP-Link Omada Gateways. During communication with a third-party DDNS service, authentication credentials are transmitted over an unencrypted channel. An attacker who can\u00a0observe\u00a0or manipulate traffic between an affected device and the DDNS service may obtain sensitive authentication information or interfere with DDNS update operations. Exploitation requires DDNS to be configured, communication with an external DDNS service, and attacker visibility or control of the relevant network path.\u00a0\n\n\n\n\n\nSuccessful exploitation may result in disclosure of DDNS account credentials, unauthorized access to DDNS management functionality, or modification of DNS records associated with the affected deployment."
}
],
"impacts": [
{
"capecId": "CAPEC-158",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-158 Sniffing Network Traffic"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext transmission of sensitive information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T18:32:27.650Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"name": "Omada Gateway Firmware Downloads (EN)",
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/en/support/download/"
},
{
"name": "Omada Gateway Firmware Downloads (US)",
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/us/support/download/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.tp-link.com/us/support/faq/5256/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unencrypted Credential Transmission in Omada Gateway Dynamic DNS Authentication in Omada Gateways",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2026-19683",
"datePublished": "2026-08-20T18:32:27.650Z",
"dateReserved": "2026-08-12T23:34:21.158Z",
"dateUpdated": "2026-08-20T18:58:42.948Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-19586 (GCVE-0-2026-19586)
Vulnerability from nvd – Published: 2026-08-20 18:32 – Updated: 2026-08-28 16:10
VLAI
EPSS
VEX
Title
Pre-Authentication OS Command Injection in Omada Gateways on OpenVPN Server in Omada Gateways
Summary
A pre-authentication OS command injection vulnerability has been identified in Omada gateways configured to operate as an OpenVPN Server due to insufficient validation of client-supplied data during OpenVPN connection establishment. An unauthenticated remote attacker may provide specially crafted input influencing backend command execution logic before authentication completes. Exploitation requires the OpenVPN Server feature to be enabled, VPN service reachable by the attacker and attacker to be able to initiate an OpenVPN connection attempt.
Successful exploitation may allow arbitrary command execution, potentially
leading to full compromise of the affected device.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-20 00:00 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://www.omadanetworks.com/en/support/download/ | patch |
| https://www.omadanetworks.com/us/support/download/ | patch |
| https://www.tp-link.com/us/support/faq/5256/ | vendor-advisory |
| https://mattg.systems/posts/cve-2026-19586/ | third-party-advisory |
Impacted products
19 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | ER7212PC v2 |
Affected:
0 , < 2.4.3 Build 20260722 Rel.40250
(custom)
|
|
| TP-Link Systems Inc. | ER605 v2 |
Affected:
0 , < 2.4.4 Build 20260630 Rel.14398
(custom)
|
|
| TP-Link Systems Inc. | ER7206 v2 |
Affected:
0 , < 2.3.5 Build 20260625 Rel.43136
(custom)
|
|
| TP-Link Systems Inc | ER7406 v1 |
Affected:
0 , < 1.3.4 Build 20260625 Rel.43136
(custom)
|
|
| TP-Link Systems Inc. | ER707-M2 v1 |
Affected:
0 , < 1.4.4 Build 20260625 Rel.43063
(custom)
|
|
| TP-Link Systems Inc | ER7412-M2 v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.82947
(custom)
|
|
| TP-Link Systems Inc. | ER8411 v1 |
Affected:
0 , < 1.4.1 Build 20260708 Rel.64832
(custom)
|
|
| TP-Link Systems Inc. | ER706W v1 |
Affected:
0 , < 1.2.11 Build 20260723 Rel.41567
(custom)
|
|
| TP-Link Systems Inc. | v1 |
Affected:
0 , < 1.2.6 Build 20260723 Rel.41321
(custom)
|
|
| TP-Link Systems Inc. | ER706W-4G v2 |
Affected:
0 , < 2.1.11 Build 20260723 Rel.41624
(custom)
|
|
| TP-Link Systems Inc. | ER706WP-4G v1 |
Affected:
0 , < 1.1.11 Build 20260723 Rel.41624
(custom)
|
|
| TP-Link Systems Inc. | ER703WP-4G-Outdoor v1 |
Affected:
0 , < 1.1.7 Build 20260723 Rel.41712
(custom)
|
|
| TP-Link Systems Inc. | DR3220v-4G v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.82652
(custom)
|
|
| TP-Link Systems Inc. | DR3650v v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.83311
(custom)
|
|
| TP-Link Systems Inc. | DR3650v-4G v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.83347
(custom)
|
|
| TP-Link Systems Inc. | ER603WP-4G-Outdoor v1 |
Affected:
0 , < 1.0.2 Build 20260723 Rel.43271
(custom)
|
|
| TP-Link Systems Inc. | DR3150 v1 |
Affected:
0 , < 1.0.1 Build 20260722 Rel.16854
(custom)
|
|
| TP-Link Systems Inc. | ER701-5G-Outdoor v1 |
Affected:
0 , < 1.0.3 Build 20260723 Rel.40931
(custom)
|
|
| TP-Link Systems Inc. | ER605W v2 |
Affected:
0 , < 2.0.4 Build 20260723 Rel.43763
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-19586",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-21T03:56:42.164Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ER7212PC v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.3 Build 20260722 Rel.40250",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.4 Build 20260630 Rel.14398",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7206 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.5 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7406 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.3.4 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER707-M2 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.4 Build 20260625 Rel.43063",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7412-M2 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82947",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER8411 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.1 Build 20260708 Rel.64832",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.11 Build 20260723 Rel.41567",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.6 Build 20260723 Rel.41321",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706WP-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER703WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.7 Build 20260723 Rel.41712",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3220v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82652",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83311",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83347",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER603WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.2 Build 20260723 Rel.43271",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3150 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20260722 Rel.16854",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER701-5G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20260723 Rel.40931",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605W v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.4 Build 20260723 Rel.43763",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Matt Graham (mattg.systems)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA pre-authentication OS command injection vulnerability has been identified in Omada gateways configured to operate as an OpenVPN Server due to insufficient validation of client-supplied data during OpenVPN connection establishment. An unauthenticated remote attacker may provide specially crafted input influencing backend command execution logic before authentication completes. Exploitation requires the OpenVPN Server feature to be enabled, VPN service reachable by the attacker and attacker to be able to initiate an OpenVPN connection attempt.\u0026nbsp;\u003c/p\u003e\u003cp\u003eSuccessful exploitation may allow arbitrary command execution,\u0026nbsp;\u003cspan\u003epotentially\nleading to full compromise of the affected device.\u003c/span\u003e\u003c/p\u003e"
}
],
"value": "A pre-authentication OS command injection vulnerability has been identified in Omada gateways configured to operate as an OpenVPN Server due to insufficient validation of client-supplied data during OpenVPN connection establishment. An unauthenticated remote attacker may provide specially crafted input influencing backend command execution logic before authentication completes. Exploitation requires the OpenVPN Server feature to be enabled, VPN service reachable by the attacker and attacker to be able to initiate an OpenVPN connection attempt.\u00a0\n\n\n\nSuccessful exploitation may allow arbitrary command execution,\u00a0potentially\nleading to full compromise of the affected device."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-28T16:10:43.693Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"name": "Omada Gateway Firmware Downloads (EN)",
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/en/support/download/"
},
{
"name": "Omada Gateway Firmware Downloads (US)",
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/us/support/download/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.tp-link.com/us/support/faq/5256/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://mattg.systems/posts/cve-2026-19586/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Pre-Authentication OS Command Injection in Omada Gateways on OpenVPN Server in Omada Gateways",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2026-19586",
"datePublished": "2026-08-20T18:32:06.942Z",
"dateReserved": "2026-08-12T00:06:23.069Z",
"dateUpdated": "2026-08-28T16:10:43.693Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-9290 (GCVE-0-2025-9290)
Vulnerability from nvd – Published: 2026-01-22 23:14 – Updated: 2026-10-06 23:18
VLAI
EPSS
VEX
Title
Authentication Weakness on Omada Controllers, Gateways and Access Points
Summary
An authentication weakness was identified in Omada Controllers, Gateways and Access Points, controller-device adoption due to improper handling of random values. Exploitation requires advanced network positioning and allows an attacker to intercept adoption traffic and forge valid authentication through offline precomputation, potentially exposing sensitive information and compromising confidentiality.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-23 20:04 UTC
CWE
- CWE-760 - Use of a One-Way Hash with a Predictable Salt
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.omadanetworks.com/us/download/ | patch |
| https://support.omadanetworks.com/en/download/ | patch |
| https://support.omadanetworks.com/us/document/114950/ | vendor-advisory |
Impacted products
30 products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9290",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-23T20:04:16.930287Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-23T20:04:29.976Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows",
"Linux"
],
"product": "Omada Software Controller",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "6.0.0.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Cloud Controller",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "6.0.0.100",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Hardware Controller (OC200, OC300, OC400)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "6.0.0.34",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Hardware Controller OC220",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "5.15.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER605 v2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.2 Build 20251029 Rel.12727",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER7206 v2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.2.2 Build 20250724 Rel.11109",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER7406, ER706W, ER706-4G)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.x",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER707-M2, ER-8411)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.3.x",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER7412-M2, ER706WP-4G, ER703WP-4G-Outdoor, DR3220v-4G, DR3650v, DR3650v-4G)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER8411)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.3.5 Build 20251028 Rel.06811",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER706W-4G 2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0 Build 20250810 Rel.77020",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER701-5G-Outdoor)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.0 Build 20250826 Rel.68862",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER605W 2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.2 Build 20250723 Rel.39048",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway ER7212PC 2.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.2.1 Build 20251027 Rel.75129",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Festa Gateway FR365",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.10 Build 20250626 Rel.81746",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway G36W-4G",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.5 Build 20250710 Rel.62142",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP660 HD v1.0/v2.0, EAP620 HD v2.0/v3.0/v3.20, EAP610/EAP610-Outdoor v1.0/v2.0, EAP623-Outdoor HD v1.0, EAP625-Outdoor HD v1.0)EAP",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.6.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP655-Wall v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.6.2 Build 20251107 Rel.35700",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP772 v1.0, EAP773 v1.0, EAP783 v1.0, EAP787 v1.0, EAP720 v1.0, EAP725-Wall v1.0, EAp723 v2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP723 v1.0, EAP772 v2.0, EAP772-Outdoor v 1.0, EAP770 v2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.3.2 Build 20250901 Rel.52255",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP215 Bridge KIT 3.0, EAP211 Bridge KIT 3.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.4 Build 20251112 Rel.34769",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Beam Bridge 5 UR v1.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.5 Build 20250928 Rel.68499",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP603GP-Desktop, EAP615GP-Wall 1.20, EAP625GP-Wall 1.0/1.20, EAP610GP-Desktop 1.0/1.20/1.26), EAP650-Desktop v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP650GP-Desktop 1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20250819 Rel.60298",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP653 v1.0, EAP650-Outdoor v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.3.3 Build 20251111 Rel.72627",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP230-Wall v1.0, EAP235-Wall v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "3.3.1 Build 20251203 Rel.58135",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP603-Outdoor v1.0, EAP615-Wall v1.0/v1.20)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.5.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP653 UR v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.2 Build 20251208 Rel.43830",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP615-Wall v1.0/v1.20)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.5.10 Build 20250903 Rel.49784",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada EAP100-Bridge KIT v1.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20251015 Rel.62058",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Stanislav Dashevskyi and Francesco La Spina of Forescout Technologies"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An authentication weakness was identified in Omada Controllers, Gateways and Access Points, controller-device adoption due to improper handling of random values. Exploitation requires advanced network positioning and allows an attacker to intercept adoption traffic and forge valid authentication through offline precomputation, potentially exposing sensitive information and compromising confidentiality."
}
],
"value": "An authentication weakness was identified in Omada Controllers, Gateways and Access Points, controller-device adoption due to improper handling of random values. Exploitation requires advanced network positioning and allows an attacker to intercept adoption traffic and forge valid authentication through offline precomputation, potentially exposing sensitive information and compromising confidentiality."
}
],
"impacts": [
{
"capecId": "CAPEC-112",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-112 Brute Force"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-760",
"description": "CWE-760 Use of a One-Way Hash with a Predictable Salt",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T23:18:29.360Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"patch"
],
"url": "https://support.omadanetworks.com/us/download/"
},
{
"tags": [
"patch"
],
"url": "https://support.omadanetworks.com/en/download/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/us/document/114950/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authentication Weakness on Omada Controllers, Gateways and Access Points",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-9290",
"datePublished": "2026-01-22T23:14:45.823Z",
"dateReserved": "2025-08-20T22:24:20.340Z",
"dateUpdated": "2026-10-06T23:18:29.360Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-7851 (GCVE-0-2025-7851)
Vulnerability from nvd – Published: 2025-10-21 00:29 – Updated: 2025-10-24 17:00
VLAI
EPSS
VEX
Title
Unauthorized root access via debug functionality
Summary
An attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 14:07 UTC
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
5 references
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7851",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:07:19.825502Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:07:59.499Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Stanislav Dashevskyi and Francesco La Spina of Forescout"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eAn attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "An attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-24T17:00:06.753Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108456/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
},
{
"url": "https://www.forescout.com/blog/new-tp-link-router-vulnerabilities-a-primer-on-rooting-routers/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthorized root access via debug functionality",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-7851",
"datePublished": "2025-10-21T00:29:05.809Z",
"dateReserved": "2025-07-18T21:49:12.159Z",
"dateUpdated": "2025-10-24T17:00:06.753Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7850 (GCVE-0-2025-7850)
Vulnerability from nvd – Published: 2025-10-21 00:28 – Updated: 2025-10-24 16:59
VLAI
EPSS
VEX
Title
Authenticated OS command execution
Summary
A command injection vulnerability may be exploited after the admin's authentication on the web portal on Omada gateways.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 14:09 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
5 references
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7850",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:09:38.276316Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:10:11.876Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Stanislav Dashevskyi and Francesco La Spina of Forescout"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eA command injection vulnerability may be exploited after the admin\u0027s authentication on the web portal on Omada gateways.\u003cbr\u003e\u003c/div\u003e"
}
],
"value": "A command injection vulnerability may be exploited after the admin\u0027s authentication on the web portal on Omada gateways."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-24T16:59:25.310Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108456/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
},
{
"url": "https://www.forescout.com/blog/new-tp-link-router-vulnerabilities-a-primer-on-rooting-routers/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authenticated OS command execution",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-7850",
"datePublished": "2025-10-21T00:28:11.589Z",
"dateReserved": "2025-07-18T21:49:10.486Z",
"dateUpdated": "2025-10-24T16:59:25.310Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6542 (GCVE-0-2025-6542)
Vulnerability from nvd – Published: 2025-10-21 00:23 – Updated: 2025-10-21 14:15
VLAI
EPSS
VEX
Title
OS command injection in multiple parameters
Summary
An arbitrary OS command may be executed on the product by a remote unauthenticated attacker.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 14:14 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://support.omadanetworks.com/en/document/108455/ | vendor-advisory |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.tp-link.com/us/business-networking/so… | product |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6542",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:14:50.370895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:15:13.774Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An arbitrary OS command may be executed on the product by a remote unauthenticated attacker."
}
],
"value": "An arbitrary OS command may be executed on the product by a remote unauthenticated attacker."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T01:16:09.887Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108455/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "OS command injection in multiple parameters",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-6542",
"datePublished": "2025-10-21T00:23:08.908Z",
"dateReserved": "2025-06-23T17:48:10.419Z",
"dateUpdated": "2025-10-21T14:15:13.774Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6541 (GCVE-0-2025-6541)
Vulnerability from nvd – Published: 2025-10-21 00:21 – Updated: 2025-10-21 13:57
VLAI
EPSS
VEX
Title
OS command injection using information obtained from the web management interface
Summary
An arbitrary OS command may be executed on the product by the user who can log in to the web management interface.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 13:56 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://support.omadanetworks.com/en/document/108455/ | vendor-advisory |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.tp-link.com/us/business-networking/so… | product |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6541",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T13:56:36.534414Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T13:57:51.728Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An arbitrary OS command may be executed on the product by the user who can log in to the web management interface."
}
],
"value": "An arbitrary OS command may be executed on the product by the user who can log in to the web management interface."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T00:21:42.535Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108455/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "OS command injection using information obtained from the web management interface",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-6541",
"datePublished": "2025-10-21T00:21:42.535Z",
"dateReserved": "2025-06-23T17:48:07.425Z",
"dateUpdated": "2025-10-21T13:57:51.728Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-19683 (GCVE-0-2026-19683)
Vulnerability from cvelistv5 – Published: 2026-08-20 18:32 – Updated: 2026-08-20 18:58
VLAI
EPSS
VEX
Title
Unencrypted Credential Transmission in Omada Gateway Dynamic DNS Authentication in Omada Gateways
Summary
A vulnerability exists in the Dynamic DNS (DDNS) functionality of TP-Link Omada Gateways. During communication with a third-party DDNS service, authentication credentials are transmitted over an unencrypted channel. An attacker who can observe or manipulate traffic between an affected device and the DDNS service may obtain sensitive authentication information or interfere with DDNS update operations. Exploitation requires DDNS to be configured, communication with an external DDNS service, and attacker visibility or control of the relevant network path.
Successful exploitation may result in disclosure of DDNS account credentials, unauthorized access to DDNS management functionality, or modification of DNS records associated with the affected deployment.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-20 18:55 UTC
CWE
- CWE-319 - Cleartext transmission of sensitive information
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.omadanetworks.com/en/support/download/ | patch |
| https://www.omadanetworks.com/us/support/download/ | patch |
| https://www.tp-link.com/us/support/faq/5256/ | vendor-advisory |
Impacted products
19 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | ER7212PC v2 |
Affected:
0 , < 2.4.3 Build 20260722 Rel.40250
(custom)
|
|
| TP-Link Systems Inc. | ER605 v2 |
Affected:
0 , < 2.4.4 Build 20260630 Rel.14398
(custom)
|
|
| TP-Link Systems Inc. | ER7206 v2 |
Affected:
0 , < 2.3.5 Build 20260625 Rel.43136
(custom)
|
|
| TP-Link Systems Inc | ER7406 v1 |
Affected:
0 , < 1.3.4 Build 20260625 Rel.43136
(custom)
|
|
| TP-Link Systems Inc. | ER707-M2 v1 |
Affected:
0 , < 1.4.4 Build 20260625 Rel.43063
(custom)
|
|
| TP-Link Systems Inc | ER7412-M2 v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.82947
(custom)
|
|
| TP-Link Systems Inc. | ER8411 v1 |
Affected:
0 , < 1.4.1 Build 20260708 Rel.64832
(custom)
|
|
| TP-Link Systems Inc. | ER706W v1 |
Affected:
0 , < 1.2.11 Build 20260723 Rel.41567
(custom)
|
|
| TP-Link Systems Inc. | v1 |
Affected:
0 , < 1.2.6 Build 20260723 Rel.41321
(custom)
|
|
| TP-Link Systems Inc. | ER706W-4G v2 |
Affected:
0 , < 2.1.11 Build 20260723 Rel.41624
(custom)
|
|
| TP-Link Systems Inc. | ER706WP-4G v1 |
Affected:
0 , < 1.1.11 Build 20260723 Rel.41624
(custom)
|
|
| TP-Link Systems Inc. | ER703WP-4G-Outdoor v1 |
Affected:
0 , < 1.1.7 Build 20260723 Rel.41712
(custom)
|
|
| TP-Link Systems Inc. | DR3220v-4G v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.82652
(custom)
|
|
| TP-Link Systems Inc. | DR3650v v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.83311
(custom)
|
|
| TP-Link Systems Inc. | DR3650v-4G v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.83347
(custom)
|
|
| TP-Link Systems Inc. | ER603WP-4G-Outdoor v1 |
Affected:
0 , < 1.0.2 Build 20260723 Rel.43271
(custom)
|
|
| TP-Link Systems Inc. | DR3150 v1 |
Affected:
0 , < 1.0.1 Build 20260722 Rel.16854
(custom)
|
|
| TP-Link Systems Inc. | ER701-5G-Outdoor v1 |
Affected:
0 , < 1.0.3 Build 20260723 Rel.40931
(custom)
|
|
| TP-Link Systems Inc. | ER605W v2 |
Affected:
0 , < 2.0.4 Build 20260723 Rel.43763
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-19683",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T18:55:44.295305Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T18:58:42.948Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ER7212PC v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.3 Build 20260722 Rel.40250",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.4 Build 20260630 Rel.14398",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7206 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.5 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7406 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.3.4 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER707-M2 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.4 Build 20260625 Rel.43063",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7412-M2 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82947",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER8411 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.1 Build 20260708 Rel.64832",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.11 Build 20260723 Rel.41567",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.6 Build 20260723 Rel.41321",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706WP-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER703WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.7 Build 20260723 Rel.41712",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3220v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82652",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83311",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83347",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER603WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.2 Build 20260723 Rel.43271",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3150 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20260722 Rel.16854",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER701-5G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20260723 Rel.40931",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605W v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.4 Build 20260723 Rel.43763",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cp\u003eA vulnerability exists in the Dynamic DNS (DDNS) functionality of TP-Link Omada Gateways. During communication with a third-party DDNS service, authentication credentials are transmitted over an unencrypted channel. An attacker who can\u0026nbsp;observe\u0026nbsp;or manipulate traffic between an affected device and the DDNS service may obtain sensitive authentication information or interfere with DDNS update operations. Exploitation requires DDNS to be configured, communication with an external DDNS service, and attacker visibility or control of the relevant network path.\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003eSuccessful exploitation may result in disclosure of DDNS account credentials, unauthorized access to DDNS management functionality, or modification of DNS records associated with the affected deployment.\u003c/p\u003e\u003c/div\u003e"
}
],
"value": "A vulnerability exists in the Dynamic DNS (DDNS) functionality of TP-Link Omada Gateways. During communication with a third-party DDNS service, authentication credentials are transmitted over an unencrypted channel. An attacker who can\u00a0observe\u00a0or manipulate traffic between an affected device and the DDNS service may obtain sensitive authentication information or interfere with DDNS update operations. Exploitation requires DDNS to be configured, communication with an external DDNS service, and attacker visibility or control of the relevant network path.\u00a0\n\n\n\n\n\nSuccessful exploitation may result in disclosure of DDNS account credentials, unauthorized access to DDNS management functionality, or modification of DNS records associated with the affected deployment."
}
],
"impacts": [
{
"capecId": "CAPEC-158",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-158 Sniffing Network Traffic"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext transmission of sensitive information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T18:32:27.650Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"name": "Omada Gateway Firmware Downloads (EN)",
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/en/support/download/"
},
{
"name": "Omada Gateway Firmware Downloads (US)",
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/us/support/download/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.tp-link.com/us/support/faq/5256/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unencrypted Credential Transmission in Omada Gateway Dynamic DNS Authentication in Omada Gateways",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2026-19683",
"datePublished": "2026-08-20T18:32:27.650Z",
"dateReserved": "2026-08-12T23:34:21.158Z",
"dateUpdated": "2026-08-20T18:58:42.948Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-19586 (GCVE-0-2026-19586)
Vulnerability from cvelistv5 – Published: 2026-08-20 18:32 – Updated: 2026-08-28 16:10
VLAI
EPSS
VEX
Title
Pre-Authentication OS Command Injection in Omada Gateways on OpenVPN Server in Omada Gateways
Summary
A pre-authentication OS command injection vulnerability has been identified in Omada gateways configured to operate as an OpenVPN Server due to insufficient validation of client-supplied data during OpenVPN connection establishment. An unauthenticated remote attacker may provide specially crafted input influencing backend command execution logic before authentication completes. Exploitation requires the OpenVPN Server feature to be enabled, VPN service reachable by the attacker and attacker to be able to initiate an OpenVPN connection attempt.
Successful exploitation may allow arbitrary command execution, potentially
leading to full compromise of the affected device.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-20 00:00 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://www.omadanetworks.com/en/support/download/ | patch |
| https://www.omadanetworks.com/us/support/download/ | patch |
| https://www.tp-link.com/us/support/faq/5256/ | vendor-advisory |
| https://mattg.systems/posts/cve-2026-19586/ | third-party-advisory |
Impacted products
19 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | ER7212PC v2 |
Affected:
0 , < 2.4.3 Build 20260722 Rel.40250
(custom)
|
|
| TP-Link Systems Inc. | ER605 v2 |
Affected:
0 , < 2.4.4 Build 20260630 Rel.14398
(custom)
|
|
| TP-Link Systems Inc. | ER7206 v2 |
Affected:
0 , < 2.3.5 Build 20260625 Rel.43136
(custom)
|
|
| TP-Link Systems Inc | ER7406 v1 |
Affected:
0 , < 1.3.4 Build 20260625 Rel.43136
(custom)
|
|
| TP-Link Systems Inc. | ER707-M2 v1 |
Affected:
0 , < 1.4.4 Build 20260625 Rel.43063
(custom)
|
|
| TP-Link Systems Inc | ER7412-M2 v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.82947
(custom)
|
|
| TP-Link Systems Inc. | ER8411 v1 |
Affected:
0 , < 1.4.1 Build 20260708 Rel.64832
(custom)
|
|
| TP-Link Systems Inc. | ER706W v1 |
Affected:
0 , < 1.2.11 Build 20260723 Rel.41567
(custom)
|
|
| TP-Link Systems Inc. | v1 |
Affected:
0 , < 1.2.6 Build 20260723 Rel.41321
(custom)
|
|
| TP-Link Systems Inc. | ER706W-4G v2 |
Affected:
0 , < 2.1.11 Build 20260723 Rel.41624
(custom)
|
|
| TP-Link Systems Inc. | ER706WP-4G v1 |
Affected:
0 , < 1.1.11 Build 20260723 Rel.41624
(custom)
|
|
| TP-Link Systems Inc. | ER703WP-4G-Outdoor v1 |
Affected:
0 , < 1.1.7 Build 20260723 Rel.41712
(custom)
|
|
| TP-Link Systems Inc. | DR3220v-4G v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.82652
(custom)
|
|
| TP-Link Systems Inc. | DR3650v v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.83311
(custom)
|
|
| TP-Link Systems Inc. | DR3650v-4G v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.83347
(custom)
|
|
| TP-Link Systems Inc. | ER603WP-4G-Outdoor v1 |
Affected:
0 , < 1.0.2 Build 20260723 Rel.43271
(custom)
|
|
| TP-Link Systems Inc. | DR3150 v1 |
Affected:
0 , < 1.0.1 Build 20260722 Rel.16854
(custom)
|
|
| TP-Link Systems Inc. | ER701-5G-Outdoor v1 |
Affected:
0 , < 1.0.3 Build 20260723 Rel.40931
(custom)
|
|
| TP-Link Systems Inc. | ER605W v2 |
Affected:
0 , < 2.0.4 Build 20260723 Rel.43763
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-19586",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-21T03:56:42.164Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ER7212PC v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.3 Build 20260722 Rel.40250",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.4 Build 20260630 Rel.14398",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7206 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.5 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7406 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.3.4 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER707-M2 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.4 Build 20260625 Rel.43063",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7412-M2 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82947",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER8411 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.1 Build 20260708 Rel.64832",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.11 Build 20260723 Rel.41567",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.6 Build 20260723 Rel.41321",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706WP-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER703WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.7 Build 20260723 Rel.41712",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3220v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82652",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83311",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83347",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER603WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.2 Build 20260723 Rel.43271",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3150 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20260722 Rel.16854",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER701-5G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20260723 Rel.40931",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605W v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.4 Build 20260723 Rel.43763",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Matt Graham (mattg.systems)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA pre-authentication OS command injection vulnerability has been identified in Omada gateways configured to operate as an OpenVPN Server due to insufficient validation of client-supplied data during OpenVPN connection establishment. An unauthenticated remote attacker may provide specially crafted input influencing backend command execution logic before authentication completes. Exploitation requires the OpenVPN Server feature to be enabled, VPN service reachable by the attacker and attacker to be able to initiate an OpenVPN connection attempt.\u0026nbsp;\u003c/p\u003e\u003cp\u003eSuccessful exploitation may allow arbitrary command execution,\u0026nbsp;\u003cspan\u003epotentially\nleading to full compromise of the affected device.\u003c/span\u003e\u003c/p\u003e"
}
],
"value": "A pre-authentication OS command injection vulnerability has been identified in Omada gateways configured to operate as an OpenVPN Server due to insufficient validation of client-supplied data during OpenVPN connection establishment. An unauthenticated remote attacker may provide specially crafted input influencing backend command execution logic before authentication completes. Exploitation requires the OpenVPN Server feature to be enabled, VPN service reachable by the attacker and attacker to be able to initiate an OpenVPN connection attempt.\u00a0\n\n\n\nSuccessful exploitation may allow arbitrary command execution,\u00a0potentially\nleading to full compromise of the affected device."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-28T16:10:43.693Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"name": "Omada Gateway Firmware Downloads (EN)",
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/en/support/download/"
},
{
"name": "Omada Gateway Firmware Downloads (US)",
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/us/support/download/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.tp-link.com/us/support/faq/5256/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://mattg.systems/posts/cve-2026-19586/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Pre-Authentication OS Command Injection in Omada Gateways on OpenVPN Server in Omada Gateways",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2026-19586",
"datePublished": "2026-08-20T18:32:06.942Z",
"dateReserved": "2026-08-12T00:06:23.069Z",
"dateUpdated": "2026-08-28T16:10:43.693Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-9033 (GCVE-0-2026-9033)
Vulnerability from cvelistv5 – Published: 2026-08-20 18:31 – Updated: 2026-08-20 18:59
VLAI
EPSS
VEX
Title
Unauthenticated Captive Portal Session Termination and Forced Logout in Omada Gateways
Summary
An unauthenticated attacker with network access to the captive portal service of an affected device can terminate active captive portal sessions, including forcing logout of specific users or clearing all active sessions. Affected users must re-authenticate to regain access.
Successful exploitation may allow termination of individual or all active captive portal sessions, causing temporary service disruption and requiring users to re-authenticate.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-20 18:59 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.omadanetworks.com/en/support/download/ | patch |
| https://www.omadanetworks.com/us/support/download/ | patch |
| https://www.tp-link.com/us/support/faq/5256/ | vendor-advisory |
Impacted products
19 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | ER7212PC v2 |
Affected:
0 , < 2.4.3 Build 20260722 Rel.40250
(custom)
|
|
| TP-Link Systems Inc. | ER605 v2 |
Affected:
0 , < 2.4.4 Build 20260630 Rel.14398
(custom)
|
|
| TP-Link Systems Inc. | ER7206 v2 |
Affected:
0 , < 2.3.5 Build 20260625 Rel.43136
(custom)
|
|
| TP-Link Systems Inc | ER7406 v1 |
Affected:
0 , < 1.3.4 Build 20260625 Rel.43136
(custom)
|
|
| TP-Link Systems Inc. | ER707-M2 v1 |
Affected:
0 , < 1.4.4 Build 20260625 Rel.43063
(custom)
|
|
| TP-Link Systems Inc | ER7412-M2 v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.82947
(custom)
|
|
| TP-Link Systems Inc. | ER8411 v1 |
Affected:
0 , < 1.4.1 Build 20260708 Rel.64832
(custom)
|
|
| TP-Link Systems Inc. | ER706W v1 |
Affected:
0 , < 1.2.11 Build 20260723 Rel.41567
(custom)
|
|
| TP-Link Systems Inc. | ER706W-4G v1 |
Affected:
0 , < 1.2.6 Build 20260723 Rel.41321
(custom)
|
|
| TP-Link Systems Inc. | ER706W-4G v2 |
Affected:
0 , < 2.1.11 Build 20260723 Rel.41624
(custom)
|
|
| TP-Link Systems Inc. | ER706WP-4G v1 |
Affected:
0 , < 1.1.11 Build 20260723 Rel.41624
(custom)
|
|
| TP-Link Systems Inc. | ER703WP-4G-Outdoor v1 |
Affected:
0 , < 1.1.7 Build 20260723 Rel.41712
(custom)
|
|
| TP-Link Systems Inc. | DR3220v-4G v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.82652
(custom)
|
|
| TP-Link Systems Inc. | DR3650v v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.83311
(custom)
|
|
| TP-Link Systems Inc. | DR3650v-4G v1 |
Affected:
0 , < 1.2.0 Build 20260630 Rel.83347
(custom)
|
|
| TP-Link Systems Inc. | ER603WP-4G-Outdoor v1 |
Affected:
0 , < 1.0.2 Build 20260723 Rel.43271
(custom)
|
|
| TP-Link Systems Inc. | DR3150 v1 |
Affected:
0 , < 1.0.1 Build 20260722 Rel.16854
(custom)
|
|
| TP-Link Systems Inc. | ER701-5G-Outdoor v1 |
Affected:
0 , < 1.0.3 Build 20260723 Rel.40931
(custom)
|
|
| TP-Link Systems Inc. | ER605W v2 |
Affected:
0 , < 2.0.4 Build 20260723 Rel.43763
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-9033",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-20T18:59:29.032581Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T18:59:36.657Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ER7212PC v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.3 Build 20260722 Rel.40250",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.4.4 Build 20260630 Rel.14398",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7206 v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.5 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7406 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.3.4 Build 20260625 Rel.43136",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER707-M2 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.4 Build 20260625 Rel.43063",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER7412-M2 v1",
"vendor": "TP-Link Systems Inc",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82947",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER8411 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.1 Build 20260708 Rel.64832",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.11 Build 20260723 Rel.41567",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.6 Build 20260723 Rel.41321",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706W-4G v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER706WP-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.11 Build 20260723 Rel.41624",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER703WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.7 Build 20260723 Rel.41712",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3220v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.82652",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83311",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3650v-4G v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.0 Build 20260630 Rel.83347",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER603WP-4G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.2 Build 20260723 Rel.43271",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "DR3150 v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20260722 Rel.16854",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER701-5G-Outdoor v1",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20260723 Rel.40931",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ER605W v2",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.4 Build 20260723 Rel.43763",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Yoontae Lee (@yunttai)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn unauthenticated attacker with network access to the captive portal service of an affected device can terminate active captive portal sessions, including forcing logout of specific users or clearing all active sessions. Affected users must re-authenticate to regain access.\u0026nbsp;\u003c/p\u003e\u003cp\u003eSuccessful exploitation may allow termination of individual or all active captive portal sessions, causing temporary service disruption and requiring users to re-authenticate.\u003c/p\u003e"
}
],
"value": "An unauthenticated attacker with network access to the captive portal service of an affected device can terminate active captive portal sessions, including forcing logout of specific users or clearing all active sessions. Affected users must re-authenticate to regain access.\u00a0\n\n\n\nSuccessful exploitation may allow termination of individual or all active captive portal sessions, causing temporary service disruption and requiring users to re-authenticate."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-20T18:31:54.806Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"name": "Omada Gateway Firmware Downloads (EN)",
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/en/support/download/"
},
{
"name": "Omada Gateway Firmware Downloads (US)",
"tags": [
"patch"
],
"url": "https://www.omadanetworks.com/us/support/download/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.tp-link.com/us/support/faq/5256/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthenticated Captive Portal Session Termination and Forced Logout in Omada Gateways",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2026-9033",
"datePublished": "2026-08-20T18:31:54.806Z",
"dateReserved": "2026-05-19T16:30:37.346Z",
"dateUpdated": "2026-08-20T18:59:36.657Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-9290 (GCVE-0-2025-9290)
Vulnerability from cvelistv5 – Published: 2026-01-22 23:14 – Updated: 2026-10-06 23:18
VLAI
EPSS
VEX
Title
Authentication Weakness on Omada Controllers, Gateways and Access Points
Summary
An authentication weakness was identified in Omada Controllers, Gateways and Access Points, controller-device adoption due to improper handling of random values. Exploitation requires advanced network positioning and allows an attacker to intercept adoption traffic and forge valid authentication through offline precomputation, potentially exposing sensitive information and compromising confidentiality.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-23 20:04 UTC
CWE
- CWE-760 - Use of a One-Way Hash with a Predictable Salt
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://support.omadanetworks.com/us/download/ | patch |
| https://support.omadanetworks.com/en/download/ | patch |
| https://support.omadanetworks.com/us/document/114950/ | vendor-advisory |
Impacted products
30 products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9290",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-23T20:04:16.930287Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-23T20:04:29.976Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows",
"Linux"
],
"product": "Omada Software Controller",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "6.0.0.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Cloud Controller",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "6.0.0.100",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Hardware Controller (OC200, OC300, OC400)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "6.0.0.34",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Hardware Controller OC220",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "5.15.24",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER605 v2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.3.2 Build 20251029 Rel.12727",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER7206 v2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.2.2 Build 20250724 Rel.11109",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER7406, ER706W, ER706-4G)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.2.x",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER707-M2, ER-8411)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.3.x",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER7412-M2, ER706WP-4G, ER703WP-4G-Outdoor, DR3220v-4G, DR3650v, DR3650v-4G)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER8411)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.3.5 Build 20251028 Rel.06811",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER706W-4G 2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.1.0 Build 20250810 Rel.77020",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER701-5G-Outdoor)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.0 Build 20250826 Rel.68862",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway (ER605W 2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.0.2 Build 20250723 Rel.39048",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway ER7212PC 2.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "2.2.1 Build 20251027 Rel.75129",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Festa Gateway FR365",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.10 Build 20250626 Rel.81746",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Gateway G36W-4G",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.5 Build 20250710 Rel.62142",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP660 HD v1.0/v2.0, EAP620 HD v2.0/v3.0/v3.20, EAP610/EAP610-Outdoor v1.0/v2.0, EAP623-Outdoor HD v1.0, EAP625-Outdoor HD v1.0)EAP",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.6.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP655-Wall v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.6.2 Build 20251107 Rel.35700",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP772 v1.0, EAP773 v1.0, EAP783 v1.0, EAP787 v1.0, EAP720 v1.0, EAP725-Wall v1.0, EAp723 v2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP723 v1.0, EAP772 v2.0, EAP772-Outdoor v 1.0, EAP770 v2.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.3.2 Build 20250901 Rel.52255",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP215 Bridge KIT 3.0, EAP211 Bridge KIT 3.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.4 Build 20251112 Rel.34769",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Beam Bridge 5 UR v1.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.5 Build 20250928 Rel.68499",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP603GP-Desktop, EAP615GP-Wall 1.20, EAP625GP-Wall 1.0/1.20, EAP610GP-Desktop 1.0/1.20/1.26), EAP650-Desktop v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP650GP-Desktop 1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.1 Build 20250819 Rel.60298",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP653 v1.0, EAP650-Outdoor v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.3.3 Build 20251111 Rel.72627",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP230-Wall v1.0, EAP235-Wall v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "3.3.1 Build 20251203 Rel.58135",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP603-Outdoor v1.0, EAP615-Wall v1.0/v1.20)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.5.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP653 UR v1.0)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.4.2 Build 20251208 Rel.43830",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Access Point (EAP615-Wall v1.0/v1.20)",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.5.10 Build 20250903 Rel.49784",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada EAP100-Bridge KIT v1.0",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "1.0.3 Build 20251015 Rel.62058",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Stanislav Dashevskyi and Francesco La Spina of Forescout Technologies"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An authentication weakness was identified in Omada Controllers, Gateways and Access Points, controller-device adoption due to improper handling of random values. Exploitation requires advanced network positioning and allows an attacker to intercept adoption traffic and forge valid authentication through offline precomputation, potentially exposing sensitive information and compromising confidentiality."
}
],
"value": "An authentication weakness was identified in Omada Controllers, Gateways and Access Points, controller-device adoption due to improper handling of random values. Exploitation requires advanced network positioning and allows an attacker to intercept adoption traffic and forge valid authentication through offline precomputation, potentially exposing sensitive information and compromising confidentiality."
}
],
"impacts": [
{
"capecId": "CAPEC-112",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-112 Brute Force"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-760",
"description": "CWE-760 Use of a One-Way Hash with a Predictable Salt",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T23:18:29.360Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"patch"
],
"url": "https://support.omadanetworks.com/us/download/"
},
{
"tags": [
"patch"
],
"url": "https://support.omadanetworks.com/en/download/"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/us/document/114950/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authentication Weakness on Omada Controllers, Gateways and Access Points",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-9290",
"datePublished": "2026-01-22T23:14:45.823Z",
"dateReserved": "2025-08-20T22:24:20.340Z",
"dateUpdated": "2026-10-06T23:18:29.360Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-7851 (GCVE-0-2025-7851)
Vulnerability from cvelistv5 – Published: 2025-10-21 00:29 – Updated: 2025-10-24 17:00
VLAI
EPSS
VEX
Title
Unauthorized root access via debug functionality
Summary
An attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 14:07 UTC
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
5 references
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7851",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:07:19.825502Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:07:59.499Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Stanislav Dashevskyi and Francesco La Spina of Forescout"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eAn attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "An attacker may obtain the root shell on the underlying OS system with the restricted conditions on Omada gateways."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-24T17:00:06.753Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108456/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
},
{
"url": "https://www.forescout.com/blog/new-tp-link-router-vulnerabilities-a-primer-on-rooting-routers/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Unauthorized root access via debug functionality",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-7851",
"datePublished": "2025-10-21T00:29:05.809Z",
"dateReserved": "2025-07-18T21:49:12.159Z",
"dateUpdated": "2025-10-24T17:00:06.753Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-7850 (GCVE-0-2025-7850)
Vulnerability from cvelistv5 – Published: 2025-10-21 00:28 – Updated: 2025-10-24 16:59
VLAI
EPSS
VEX
Title
Authenticated OS command execution
Summary
A command injection vulnerability may be exploited after the admin's authentication on the web portal on Omada gateways.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 14:09 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
5 references
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7850",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:09:38.276316Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:10:11.876Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Stanislav Dashevskyi and Francesco La Spina of Forescout"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eA command injection vulnerability may be exploited after the admin\u0027s authentication on the web portal on Omada gateways.\u003cbr\u003e\u003c/div\u003e"
}
],
"value": "A command injection vulnerability may be exploited after the admin\u0027s authentication on the web portal on Omada gateways."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-24T16:59:25.310Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108456/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
},
{
"url": "https://www.forescout.com/blog/new-tp-link-router-vulnerabilities-a-primer-on-rooting-routers/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authenticated OS command execution",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-7850",
"datePublished": "2025-10-21T00:28:11.589Z",
"dateReserved": "2025-07-18T21:49:10.486Z",
"dateUpdated": "2025-10-24T16:59:25.310Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6542 (GCVE-0-2025-6542)
Vulnerability from cvelistv5 – Published: 2025-10-21 00:23 – Updated: 2025-10-21 14:15
VLAI
EPSS
VEX
Title
OS command injection in multiple parameters
Summary
An arbitrary OS command may be executed on the product by a remote unauthenticated attacker.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 14:14 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://support.omadanetworks.com/en/document/108455/ | vendor-advisory |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.tp-link.com/us/business-networking/so… | product |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6542",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T14:14:50.370895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:15:13.774Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An arbitrary OS command may be executed on the product by a remote unauthenticated attacker."
}
],
"value": "An arbitrary OS command may be executed on the product by a remote unauthenticated attacker."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T01:16:09.887Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108455/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "OS command injection in multiple parameters",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-6542",
"datePublished": "2025-10-21T00:23:08.908Z",
"dateReserved": "2025-06-23T17:48:10.419Z",
"dateUpdated": "2025-10-21T14:15:13.774Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6541 (GCVE-0-2025-6541)
Vulnerability from cvelistv5 – Published: 2025-10-21 00:21 – Updated: 2025-10-21 13:57
VLAI
EPSS
VEX
Title
OS command injection using information obtained from the web management interface
Summary
An arbitrary OS command may be executed on the product by the user who can log in to the web management interface.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-21 13:56 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://support.omadanetworks.com/en/document/108455/ | vendor-advisory |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.omadanetworks.com/us/business-network… | product |
| https://www.tp-link.com/us/business-networking/so… | product |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| TP-Link Systems Inc. | Omada gateways |
Affected:
0 , < ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3
(Firmware)
|
|
| TP-Link Systems Inc. | Festa gateways |
Affected:
0 , < FR365 1.1.10, FR205 1.0.3, FR307 1.2.5
(Firmware)
|
|
| TP-Link Systems Inc. | Omada Pro gateways |
Affected:
0 , < G36 1.1.4, G611 1.2.2
(Firmware)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6541",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-21T13:56:36.534414Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T13:57:51.728Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Omada gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "ER8411 1.3.3, ER7412-M2 1.1.0, ER707-M2 1.3.1, ER7206 2.2.2, ER605 2.3.1, ER706W 1.2.1, ER706W-4G 1.2.1, ER7212PC 2.1.3",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Festa gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "FR365 1.1.10, FR205 1.0.3, FR307 1.2.5",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Omada Pro gateways",
"vendor": "TP-Link Systems Inc.",
"versions": [
{
"lessThan": "G36 1.1.4, G611 1.2.2",
"status": "affected",
"version": "0",
"versionType": "Firmware"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An arbitrary OS command may be executed on the product by the user who can log in to the web management interface."
}
],
"value": "An arbitrary OS command may be executed on the product by the user who can log in to the web management interface."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T00:21:42.535Z",
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.omadanetworks.com/en/document/108455/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/all-omada-router/"
},
{
"tags": [
"product"
],
"url": "https://www.omadanetworks.com/us/business-networking/omada-pro-router-wired-router/"
},
{
"tags": [
"product"
],
"url": "https://www.tp-link.com/us/business-networking/soho-festa-gateway/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "OS command injection using information obtained from the web management interface",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"assignerShortName": "TPLink",
"cveId": "CVE-2025-6541",
"datePublished": "2025-10-21T00:21:42.535Z",
"dateReserved": "2025-06-23T17:48:07.425Z",
"dateUpdated": "2025-10-21T13:57:51.728Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}