Search criteria

8 vulnerabilities found for en100_ethernet_module_firmware by siemens

CVE-2018-16563 (GCVE-0-2018-16563)

Vulnerability from nvd – Published: 2019-03-21 14:57 – Updated: 2024-08-05 10:24
VLAI?
Summary
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity ?
No CVSS data available.
CWE
  • Other
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:24:32.996Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Firmware variant IEC 61850 for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.35"
            }
          ]
        },
        {
          "product": "Firmware variant MODBUS TCP for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant DNP3 TCP for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant IEC104 for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant Profinet IO for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.82"
            }
          ]
        },
        {
          "product": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.58"
            }
          ]
        }
      ],
      "datePublic": "2019-02-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Other",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-21T14:57:36",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2018-16563",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant IEC 61850 for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.35"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant MODBUS TCP for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant DNP3 TCP for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant IEC104 for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant Profinet IO for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.82"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.58"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-16563",
    "datePublished": "2019-03-21T14:57:36",
    "dateReserved": "2018-09-06T00:00:00",
    "dateUpdated": "2024-08-05T10:24:32.996Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-7114 (GCVE-0-2016-7114)

Vulnerability from nvd – Published: 2016-09-06 00:00 – Updated: 2024-09-16 22:50
VLAI?
Summary
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.87; SIPROTEC 7UT686 : All versions < V 4.02; SIPROTEC 7SD686 : All versions < V 4.05; SIPROTEC 7SJ66 : All versions < V 4.30. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:50:47.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "92745",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/92745"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
          },
          {
            "name": "99471",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99471"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.87; SIPROTEC 7UT686 : All versions \u003c V 4.02; SIPROTEC 7SD686 : All versions \u003c V 4.05; SIPROTEC 7SJ66 : All versions \u003c V 4.30. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T17:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "92745",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/92745"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
        },
        {
          "name": "99471",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99471"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2017-07-04T00:00:00",
          "ID": "CVE-2016-7114",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.87; SIPROTEC 7UT686 : All versions \u003c V 4.02; SIPROTEC 7SD686 : All versions \u003c V 4.05; SIPROTEC 7SJ66 : All versions \u003c V 4.30. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "92745",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/92745"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
            },
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
            },
            {
              "name": "99471",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99471"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-7114",
    "datePublished": "2016-09-06T00:00:00Z",
    "dateReserved": "2016-08-30T00:00:00",
    "dateUpdated": "2024-09-16T22:50:42.737Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-7113 (GCVE-0-2016-7113)

Vulnerability from nvd – Published: 2016-09-06 00:00 – Updated: 2024-09-16 16:19
VLAI?
Summary
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:50:47.436Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "92748",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/92748"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
          },
          {
            "name": "99471",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99471"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T17:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "92748",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/92748"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
        },
        {
          "name": "99471",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99471"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2017-07-04T00:00:00",
          "ID": "CVE-2016-7113",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "92748",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/92748"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
            },
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
            },
            {
              "name": "99471",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99471"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-7113",
    "datePublished": "2016-09-06T00:00:00Z",
    "dateReserved": "2016-08-30T00:00:00",
    "dateUpdated": "2024-09-16T16:19:06.371Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-7112 (GCVE-0-2016-7112)

Vulnerability from nvd – Published: 2016-09-06 00:00 – Updated: 2024-09-16 17:58
VLAI?
Summary
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:50:47.462Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "92747",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/92747"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
          },
          {
            "name": "99471",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99471"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T17:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "92747",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/92747"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
        },
        {
          "name": "99471",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99471"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2017-07-04T00:00:00",
          "ID": "CVE-2016-7112",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "92747",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/92747"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
            },
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
            },
            {
              "name": "99471",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99471"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-7112",
    "datePublished": "2016-09-06T00:00:00Z",
    "dateReserved": "2016-08-30T00:00:00",
    "dateUpdated": "2024-09-16T17:58:01.834Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16563 (GCVE-0-2018-16563)

Vulnerability from cvelistv5 – Published: 2019-03-21 14:57 – Updated: 2024-08-05 10:24
VLAI?
Summary
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity ?
No CVSS data available.
CWE
  • Other
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:24:32.996Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Firmware variant IEC 61850 for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.35"
            }
          ]
        },
        {
          "product": "Firmware variant MODBUS TCP for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant DNP3 TCP for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant IEC104 for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Firmware variant Profinet IO for EN100 Ethernet module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.82"
            }
          ]
        },
        {
          "product": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.58"
            }
          ]
        }
      ],
      "datePublic": "2019-02-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Other",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-21T14:57:36",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2018-16563",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant IEC 61850 for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.35"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant MODBUS TCP for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant DNP3 TCP for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant IEC104 for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Firmware variant Profinet IO for EN100 Ethernet module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.82"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              },
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.58"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-16563",
    "datePublished": "2019-03-21T14:57:36",
    "dateReserved": "2018-09-06T00:00:00",
    "dateUpdated": "2024-08-05T10:24:32.996Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-7114 (GCVE-0-2016-7114)

Vulnerability from cvelistv5 – Published: 2016-09-06 00:00 – Updated: 2024-09-16 22:50
VLAI?
Summary
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.87; SIPROTEC 7UT686 : All versions < V 4.02; SIPROTEC 7SD686 : All versions < V 4.05; SIPROTEC 7SJ66 : All versions < V 4.30. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:50:47.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "92745",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/92745"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
          },
          {
            "name": "99471",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99471"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.87; SIPROTEC 7UT686 : All versions \u003c V 4.02; SIPROTEC 7SD686 : All versions \u003c V 4.05; SIPROTEC 7SJ66 : All versions \u003c V 4.30. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T17:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "92745",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/92745"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
        },
        {
          "name": "99471",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99471"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2017-07-04T00:00:00",
          "ID": "CVE-2016-7114",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.87; SIPROTEC 7UT686 : All versions \u003c V 4.02; SIPROTEC 7SD686 : All versions \u003c V 4.05; SIPROTEC 7SJ66 : All versions \u003c V 4.30. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "92745",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/92745"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
            },
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
            },
            {
              "name": "99471",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99471"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-7114",
    "datePublished": "2016-09-06T00:00:00Z",
    "dateReserved": "2016-08-30T00:00:00",
    "dateUpdated": "2024-09-16T22:50:42.737Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-7112 (GCVE-0-2016-7112)

Vulnerability from cvelistv5 – Published: 2016-09-06 00:00 – Updated: 2024-09-16 17:58
VLAI?
Summary
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:50:47.462Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "92747",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/92747"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
          },
          {
            "name": "99471",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99471"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T17:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "92747",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/92747"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
        },
        {
          "name": "99471",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99471"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2017-07-04T00:00:00",
          "ID": "CVE-2016-7112",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "92747",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/92747"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
            },
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
            },
            {
              "name": "99471",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99471"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-7112",
    "datePublished": "2016-09-06T00:00:00Z",
    "dateReserved": "2016-08-30T00:00:00",
    "dateUpdated": "2024-09-16T17:58:01.834Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-7113 (GCVE-0-2016-7113)

Vulnerability from cvelistv5 – Published: 2016-09-06 00:00 – Updated: 2024-09-16 16:19
VLAI?
Summary
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:50:47.436Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "92748",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/92748"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
          },
          {
            "name": "99471",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99471"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T17:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "92748",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/92748"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
        },
        {
          "name": "99471",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99471"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2017-07-04T00:00:00",
          "ID": "CVE-2016-7113",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "92748",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/92748"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
            },
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf"
            },
            {
              "name": "99471",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99471"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-7113",
    "datePublished": "2016-09-06T00:00:00Z",
    "dateReserved": "2016-08-30T00:00:00",
    "dateUpdated": "2024-09-16T16:19:06.371Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}