Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for ecostruxure_geo_scada_expert_2021 by schneider-electric

    CVE-2023-0595 (GCVE-0-2023-0595)

    Vulnerability from nvd – Published: 2023-02-24 00:00 – Updated: 2025-02-05 20:06
    VLAI
    Summary
    A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-117 - Improper Output Neutralization for Logs
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:17:50.139Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-0595",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:54:54.186453Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:06:14.347Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Geo SCADA Expert 2019",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "October 2022",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Geo SCADA Expert 2020",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "October 2022",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Geo SCADA Expert 2021",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "October 2022",
                  "status": "affected",
                  "version": "All ",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ClearSCADA ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All  Versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server\u0027s database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)\u003c/p\u003e"
                }
              ],
              "value": "A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server\u0027s database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-117",
                  "description": "CWE-117 Improper Output Neutralization for Logs",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-04-18T20:15:26.476Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-01.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-0595",
        "datePublished": "2023-02-24T00:00:00.000Z",
        "dateReserved": "2023-01-31T00:00:00.000Z",
        "dateUpdated": "2025-02-05T20:06:14.347Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-22611 (GCVE-0-2023-22611)

    Vulnerability from nvd – Published: 2023-01-31 00:00 – Updated: 2025-02-05 20:06
    VLAI
    Summary
    A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:13:49.470Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-22611",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:54:59.647770Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:06:52.179Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "October 2022",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-03T00:00:00.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-22611",
        "datePublished": "2023-01-31T00:00:00.000Z",
        "dateReserved": "2023-01-04T00:00:00.000Z",
        "dateUpdated": "2025-02-05T20:06:52.179Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-22610 (GCVE-0-2023-22610)

    Vulnerability from nvd – Published: 2023-01-31 00:00 – Updated: 2025-02-05 20:06
    VLAI
    Summary
    A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:13:49.385Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-22610",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:55:02.779459Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:06:58.944Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "October 2022",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\n\nA CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of\nService against the Geo SCADA server when specific messages are sent to the server over the\ndatabase server TCP port. \n\n\u003c/p\u003e"
                }
              ],
              "value": "\nA CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of\nService against the Geo SCADA server when specific messages are sent to the server over the\ndatabase server TCP port. \n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-14T07:17:44.658Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-22610",
        "datePublished": "2023-01-31T00:00:00.000Z",
        "dateReserved": "2023-01-04T00:00:00.000Z",
        "dateUpdated": "2025-02-05T20:06:58.944Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-0595 (GCVE-0-2023-0595)

    Vulnerability from cvelistv5 – Published: 2023-02-24 00:00 – Updated: 2025-02-05 20:06
    VLAI
    Summary
    A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-117 - Improper Output Neutralization for Logs
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:17:50.139Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-0595",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:54:54.186453Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:06:14.347Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Geo SCADA Expert 2019",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "October 2022",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Geo SCADA Expert 2020",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "October 2022",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Geo SCADA Expert 2021",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThanOrEqual": "October 2022",
                  "status": "affected",
                  "version": "All ",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ClearSCADA ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All  Versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server\u0027s database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)\u003c/p\u003e"
                }
              ],
              "value": "A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server\u0027s database web port (default 443). Affected products: EcoStruxure Geo SCADA Expert 2019, EcoStruxure Geo SCADA Expert 2020, EcoStruxure Geo SCADA Expert 2021(All Versions prior to October 2022), ClearSCADA (All Versions)\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-117",
                  "description": "CWE-117 Improper Output Neutralization for Logs",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-04-18T20:15:26.476Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-045-01.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-0595",
        "datePublished": "2023-02-24T00:00:00.000Z",
        "dateReserved": "2023-01-31T00:00:00.000Z",
        "dateUpdated": "2025-02-05T20:06:14.347Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-22610 (GCVE-0-2023-22610)

    Vulnerability from cvelistv5 – Published: 2023-01-31 00:00 – Updated: 2025-02-05 20:06
    VLAI
    Summary
    A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:13:49.385Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-22610",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:55:02.779459Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:06:58.944Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "October 2022",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003e\n\nA CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of\nService against the Geo SCADA server when specific messages are sent to the server over the\ndatabase server TCP port. \n\n\u003c/p\u003e"
                }
              ],
              "value": "\nA CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of\nService against the Geo SCADA server when specific messages are sent to the server over the\ndatabase server TCP port. \n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-06-14T07:17:44.658Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-22610",
        "datePublished": "2023-01-31T00:00:00.000Z",
        "dateReserved": "2023-01-04T00:00:00.000Z",
        "dateUpdated": "2025-02-05T20:06:58.944Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-22611 (GCVE-0-2023-22611)

    Vulnerability from cvelistv5 – Published: 2023-01-31 00:00 – Updated: 2025-02-05 20:06
    VLAI
    Summary
    A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:13:49.470Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-22611",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-05T19:54:59.647770Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-05T20:06:52.179Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "lessThan": "October 2022",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200 Information Exposure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-03T00:00:00.000Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-22611",
        "datePublished": "2023-01-31T00:00:00.000Z",
        "dateReserved": "2023-01-04T00:00:00.000Z",
        "dateUpdated": "2025-02-05T20:06:52.179Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }