Search criteria
2 vulnerabilities found for ecostruxure_building_operation by schneider-electric
CVE-2020-28210 (GCVE-0-2020-28210)
Vulnerability from nvd – Published: 2020-11-19 21:01 – Updated: 2024-08-04 16:33
VLAI?
Summary
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.
Severity ?
No CVSS data available.
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (Cross-siteScripting Stored)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | EcoStruxure Building Operation WebStation V2.0 - V3.1 |
Affected:
EcoStruxure Building Operation WebStation V2.0 - V3.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:33:58.334Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EcoStruxure Building Operation WebStation V2.0 - V3.1",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "EcoStruxure Building Operation WebStation V2.0 - V3.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user\u0027s browser."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting Stored)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-19T21:01:31",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-28210",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EcoStruxure Building Operation WebStation V2.0 - V3.1",
"version": {
"version_data": [
{
"version_value": "EcoStruxure Building Operation WebStation V2.0 - V3.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user\u0027s browser."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting Stored)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-28210",
"datePublished": "2020-11-19T21:01:31",
"dateReserved": "2020-11-05T00:00:00",
"dateUpdated": "2024-08-04T16:33:58.334Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-28210 (GCVE-0-2020-28210)
Vulnerability from cvelistv5 – Published: 2020-11-19 21:01 – Updated: 2024-08-04 16:33
VLAI?
Summary
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.
Severity ?
No CVSS data available.
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (Cross-siteScripting Stored)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | EcoStruxure Building Operation WebStation V2.0 - V3.1 |
Affected:
EcoStruxure Building Operation WebStation V2.0 - V3.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:33:58.334Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EcoStruxure Building Operation WebStation V2.0 - V3.1",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "EcoStruxure Building Operation WebStation V2.0 - V3.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user\u0027s browser."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting Stored)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-19T21:01:31",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-28210",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EcoStruxure Building Operation WebStation V2.0 - V3.1",
"version": {
"version_data": [
{
"version_value": "EcoStruxure Building Operation WebStation V2.0 - V3.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user\u0027s browser."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting Stored)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-28210",
"datePublished": "2020-11-19T21:01:31",
"dateReserved": "2020-11-05T00:00:00",
"dateUpdated": "2024-08-04T16:33:58.334Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}