18 vulnerabilities found for eagle_20_tofino_943_987-501-tx\/tx_firmware by belden
FKIE_CVE-2021-30066
Vulnerability from fkie_nvd - Published: 2022-04-03 23:15 - Updated: 2026-06-17 03:49
Severity
Summary
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_xenon_security_appliance_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F59F145A-A309-45B7-8D48-5361C504DD1E",
"versionEndExcluding": "03.2.03",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_xenon_security_appliance:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1957DB06-C01D-4325-81B7-45FA93040101",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF487B74-8029-4792-A402-7182D2F51ED2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "619676E6-066C-41D9-BDBA-8D906396C6B2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFC40B4-C3F0-4CB1-962A-FC3C26F9CF52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9B67AAE0-87C0-444E-BD0A-D8D1B9CD9045",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DD759521-A74B-4942-84BC-F545DE401F3F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A931A2CB-9C8F-433A-8C9E-C9AF3E36EFC5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "66558B99-7CC4-44B1-AA0C-E12570D05DAC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "33843C19-0133-4466-A3AA-3CD165B17E81",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-100-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FB2023C5-B765-4172-8695-4F77FAB63F3B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-100-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F81C138E-8135-46C8-8D74-498920A5A2AE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-505-mm\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF6938A1-C835-4BFF-883C-08D885E76AA7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-505-mm\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F00374BD-FBDA-4F84-9328-DFEC650CBFB0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-504-mm\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EFD9640A-2FE4-4CC0-85EA-C0562B346BBA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-504-mm\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D1BCC0D0-D74A-44BA-84D1-94E5D5F714EA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-502_-tx\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE786CBA-2285-46E4-A3EE-663604E4ADB6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-502_-tx\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F783EE06-CD15-4528-987C-36D3827C6299",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-501-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5BE7527A-1642-47DE-9B63-1D014FDCAD8B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-501-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A0AA7301-DDE2-4FD3-9118-4D4E7C2F6B8F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefea23f3f20_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8FCE4712-F43E-4999-8362-2F2DAED60FD2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefea23f3f20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E7760711-D753-4F29-B25F-557A55FB839D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefea23f3f21_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5AB2EA8E-567D-451B-9439-32158D07B263",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefea23f3f21:-:*:*:*:*:*:*:*",
"matchCriteriaId": "730B4CD5-4075-48EE-B3ED-1048E3C69E72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefea23f3f22_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "428E6ECF-99BD-4E06-A8AC-6B121490242E",
"versionEndExcluding": "03.23",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefea23f3f22:-:*:*:*:*:*:*:*",
"matchCriteriaId": "75EA94E5-9D72-4E54-BBDF-8544EF774462",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400."
},
{
"lang": "es",
"value": "En Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 versiones anteriores a 03.23, TCSEFEA23F3F20/21, y Belden Tofino Xenon Security Appliance, puede cargarse una imagen de firmware arbitraria porque puede omitirse la verificaci\u00f3n de la firma del firmware (para una memoria USB). NOTA: este problema se presenta debido a una correcci\u00f3n incompleta de CVE-2017-11400"
}
],
"id": "CVE-2021-30066",
"lastModified": "2026-06-17T03:49:39.470",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-03T23:15:07.860",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.belden.com/support/security-assurance"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-347"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-30065
Vulnerability from fkie_nvd - Published: 2022-04-03 22:15 - Updated: 2026-06-17 03:49
Severity
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
7.5 (High) - CVSS:3.1/
Summary
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_xenon_security_appliance_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F59F145A-A309-45B7-8D48-5361C504DD1E",
"versionEndExcluding": "03.2.03",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_xenon_security_appliance:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1957DB06-C01D-4325-81B7-45FA93040101",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF487B74-8029-4792-A402-7182D2F51ED2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "619676E6-066C-41D9-BDBA-8D906396C6B2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFC40B4-C3F0-4CB1-962A-FC3C26F9CF52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9B67AAE0-87C0-444E-BD0A-D8D1B9CD9045",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DD759521-A74B-4942-84BC-F545DE401F3F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A931A2CB-9C8F-433A-8C9E-C9AF3E36EFC5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "66558B99-7CC4-44B1-AA0C-E12570D05DAC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "33843C19-0133-4466-A3AA-3CD165B17E81",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-100-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FB2023C5-B765-4172-8695-4F77FAB63F3B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-100-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F81C138E-8135-46C8-8D74-498920A5A2AE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-505-mm\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF6938A1-C835-4BFF-883C-08D885E76AA7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-505-mm\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F00374BD-FBDA-4F84-9328-DFEC650CBFB0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-504-mm\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EFD9640A-2FE4-4CC0-85EA-C0562B346BBA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-504-mm\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D1BCC0D0-D74A-44BA-84D1-94E5D5F714EA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-502_-tx\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE786CBA-2285-46E4-A3EE-663604E4ADB6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-502_-tx\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F783EE06-CD15-4528-987C-36D3827C6299",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-501-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5BE7527A-1642-47DE-9B63-1D014FDCAD8B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-501-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A0AA7301-DDE2-4FD3-9118-4D4E7C2F6B8F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefea23f3f20_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8FCE4712-F43E-4999-8362-2F2DAED60FD2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefea23f3f20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E7760711-D753-4F29-B25F-557A55FB839D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefea23f3f21_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5AB2EA8E-567D-451B-9439-32158D07B263",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefea23f3f21:-:*:*:*:*:*:*:*",
"matchCriteriaId": "730B4CD5-4075-48EE-B3ED-1048E3C69E72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefea23f3f22_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "428E6ECF-99BD-4E06-A8AC-6B121490242E",
"versionEndExcluding": "03.23",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefea23f3f22:-:*:*:*:*:*:*:*",
"matchCriteriaId": "75EA94E5-9D72-4E54-BBDF-8544EF774462",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401."
},
{
"lang": "es",
"value": "En Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 versiones hasta 03.23, TCSEFEA23F3F20/21 y Belden Tofino Xenon Security Appliance, los paquetes ModBus dise\u00f1ados pueden omitir el ModBus enforcer. NOTA: este problema se presenta debido a una correcci\u00f3n incompleta de CVE-2017-11401"
}
],
"id": "CVE-2021-30065",
"lastModified": "2026-06-17T03:49:39.323",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-03T22:15:14.943",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.belden.com/support/security-assurance"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-30064
Vulnerability from fkie_nvd - Published: 2022-04-03 22:15 - Updated: 2026-06-17 03:49
Severity
Summary
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_xenon_security_appliance_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F59F145A-A309-45B7-8D48-5361C504DD1E",
"versionEndExcluding": "03.2.03",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_xenon_security_appliance:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1957DB06-C01D-4325-81B7-45FA93040101",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF487B74-8029-4792-A402-7182D2F51ED2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "619676E6-066C-41D9-BDBA-8D906396C6B2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFC40B4-C3F0-4CB1-962A-FC3C26F9CF52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9B67AAE0-87C0-444E-BD0A-D8D1B9CD9045",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DD759521-A74B-4942-84BC-F545DE401F3F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A931A2CB-9C8F-433A-8C9E-C9AF3E36EFC5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "66558B99-7CC4-44B1-AA0C-E12570D05DAC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "33843C19-0133-4466-A3AA-3CD165B17E81",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-100-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FB2023C5-B765-4172-8695-4F77FAB63F3B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-100-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F81C138E-8135-46C8-8D74-498920A5A2AE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-505-mm\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF6938A1-C835-4BFF-883C-08D885E76AA7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-505-mm\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F00374BD-FBDA-4F84-9328-DFEC650CBFB0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-504-mm\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EFD9640A-2FE4-4CC0-85EA-C0562B346BBA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-504-mm\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D1BCC0D0-D74A-44BA-84D1-94E5D5F714EA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-502_-tx\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE786CBA-2285-46E4-A3EE-663604E4ADB6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-502_-tx\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F783EE06-CD15-4528-987C-36D3827C6299",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-501-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5BE7527A-1642-47DE-9B63-1D014FDCAD8B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-501-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A0AA7301-DDE2-4FD3-9118-4D4E7C2F6B8F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefea23f3f20_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8FCE4712-F43E-4999-8362-2F2DAED60FD2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefea23f3f20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E7760711-D753-4F29-B25F-557A55FB839D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefea23f3f21_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5AB2EA8E-567D-451B-9439-32158D07B263",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefea23f3f21:-:*:*:*:*:*:*:*",
"matchCriteriaId": "730B4CD5-4075-48EE-B3ED-1048E3C69E72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefea23f3f22_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "428E6ECF-99BD-4E06-A8AC-6B121490242E",
"versionEndExcluding": "03.23",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefea23f3f22:-:*:*:*:*:*:*:*",
"matchCriteriaId": "75EA94E5-9D72-4E54-BBDF-8544EF774462",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state)."
},
{
"lang": "es",
"value": "En Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 versiones hasta 03.23, TCSEFEA23F3F20/21 y Belden Tofino Xenon Security Appliance, un inicio de sesi\u00f3n SSH puede tener \u00e9xito con credenciales embebidas predeterminadas (si el dispositivo est\u00e1 en el estado no comisionado)"
}
],
"id": "CVE-2021-30064",
"lastModified": "2026-06-17T03:49:39.193",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-03T22:15:14.900",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.belden.com/support/security-assurance"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-30063
Vulnerability from fkie_nvd - Published: 2022-04-03 22:15 - Updated: 2026-06-17 03:49
Severity
Summary
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_xenon_security_appliance_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F59F145A-A309-45B7-8D48-5361C504DD1E",
"versionEndExcluding": "03.2.03",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_xenon_security_appliance:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1957DB06-C01D-4325-81B7-45FA93040101",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF487B74-8029-4792-A402-7182D2F51ED2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "619676E6-066C-41D9-BDBA-8D906396C6B2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFC40B4-C3F0-4CB1-962A-FC3C26F9CF52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9B67AAE0-87C0-444E-BD0A-D8D1B9CD9045",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DD759521-A74B-4942-84BC-F545DE401F3F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A931A2CB-9C8F-433A-8C9E-C9AF3E36EFC5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "66558B99-7CC4-44B1-AA0C-E12570D05DAC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "33843C19-0133-4466-A3AA-3CD165B17E81",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-100-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FB2023C5-B765-4172-8695-4F77FAB63F3B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-100-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F81C138E-8135-46C8-8D74-498920A5A2AE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-505-mm\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF6938A1-C835-4BFF-883C-08D885E76AA7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-505-mm\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F00374BD-FBDA-4F84-9328-DFEC650CBFB0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-504-mm\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EFD9640A-2FE4-4CC0-85EA-C0562B346BBA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-504-mm\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D1BCC0D0-D74A-44BA-84D1-94E5D5F714EA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-502_-tx\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE786CBA-2285-46E4-A3EE-663604E4ADB6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-502_-tx\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F783EE06-CD15-4528-987C-36D3827C6299",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-501-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5BE7527A-1642-47DE-9B63-1D014FDCAD8B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-501-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A0AA7301-DDE2-4FD3-9118-4D4E7C2F6B8F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefm0000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA6C26FE-5C8C-43DE-9342-FB4375E53C0D",
"versionEndExcluding": "03.23",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefm0000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C7A0ABFC-DF90-4E86-8815-8B1CC835E88D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service."
},
{
"lang": "es",
"value": "En Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 versiones hasta 03.23 y Belden Tofino Xenon Security Appliance, los paquetes OPC dise\u00f1ados pueden provocar una denegaci\u00f3n de servicio del ejecutor OPC"
}
],
"id": "CVE-2021-30063",
"lastModified": "2026-06-17T03:49:39.063",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-03T22:15:14.857",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.belden.com/support/security-assurance"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-30062
Vulnerability from fkie_nvd - Published: 2022-04-03 22:15 - Updated: 2026-06-17 03:49
Severity
Summary
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_xenon_security_appliance_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F59F145A-A309-45B7-8D48-5361C504DD1E",
"versionEndExcluding": "03.2.03",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_xenon_security_appliance:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1957DB06-C01D-4325-81B7-45FA93040101",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF487B74-8029-4792-A402-7182D2F51ED2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "619676E6-066C-41D9-BDBA-8D906396C6B2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFC40B4-C3F0-4CB1-962A-FC3C26F9CF52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9B67AAE0-87C0-444E-BD0A-D8D1B9CD9045",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DD759521-A74B-4942-84BC-F545DE401F3F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A931A2CB-9C8F-433A-8C9E-C9AF3E36EFC5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "66558B99-7CC4-44B1-AA0C-E12570D05DAC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "33843C19-0133-4466-A3AA-3CD165B17E81",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-100-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FB2023C5-B765-4172-8695-4F77FAB63F3B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-100-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F81C138E-8135-46C8-8D74-498920A5A2AE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-505-mm\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF6938A1-C835-4BFF-883C-08D885E76AA7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-505-mm\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F00374BD-FBDA-4F84-9328-DFEC650CBFB0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-504-mm\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EFD9640A-2FE4-4CC0-85EA-C0562B346BBA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-504-mm\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D1BCC0D0-D74A-44BA-84D1-94E5D5F714EA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-502_-tx\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE786CBA-2285-46E4-A3EE-663604E4ADB6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-502_-tx\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F783EE06-CD15-4528-987C-36D3827C6299",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-501-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5BE7527A-1642-47DE-9B63-1D014FDCAD8B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-501-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A0AA7301-DDE2-4FD3-9118-4D4E7C2F6B8F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefm0000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA6C26FE-5C8C-43DE-9342-FB4375E53C0D",
"versionEndExcluding": "03.23",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefm0000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C7A0ABFC-DF90-4E86-8815-8B1CC835E88D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer."
},
{
"lang": "es",
"value": "En Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 versiones anteriores a 03.23 y Belden Tofino Xenon Security Appliance, los paquetes OPC dise\u00f1ados pueden omitir el reforzador OPC"
}
],
"id": "CVE-2021-30062",
"lastModified": "2026-06-17T03:49:38.933",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-03T22:15:14.813",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.belden.com/support/security-assurance"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-30061
Vulnerability from fkie_nvd - Published: 2022-04-03 22:15 - Updated: 2026-06-17 03:49
Severity
Summary
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_xenon_security_appliance_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F59F145A-A309-45B7-8D48-5361C504DD1E",
"versionEndExcluding": "03.2.03",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_xenon_security_appliance:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1957DB06-C01D-4325-81B7-45FA93040101",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF487B74-8029-4792-A402-7182D2F51ED2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "619676E6-066C-41D9-BDBA-8D906396C6B2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EFC40B4-C3F0-4CB1-962A-FC3C26F9CF52",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9B67AAE0-87C0-444E-BD0A-D8D1B9CD9045",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DD759521-A74B-4942-84BC-F545DE401F3F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A931A2CB-9C8F-433A-8C9E-C9AF3E36EFC5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-220-mm\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "66558B99-7CC4-44B1-AA0C-E12570D05DAC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-220-mm\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "33843C19-0133-4466-A3AA-3CD165B17E81",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:tofino_argon_fa-tsa-100-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FB2023C5-B765-4172-8695-4F77FAB63F3B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:tofino_argon_fa-tsa-100-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F81C138E-8135-46C8-8D74-498920A5A2AE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-505-mm\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF6938A1-C835-4BFF-883C-08D885E76AA7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-505-mm\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F00374BD-FBDA-4F84-9328-DFEC650CBFB0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-504-mm\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EFD9640A-2FE4-4CC0-85EA-C0562B346BBA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-504-mm\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D1BCC0D0-D74A-44BA-84D1-94E5D5F714EA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-502_-tx\\/mm_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE786CBA-2285-46E4-A3EE-663604E4ADB6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-502_-tx\\/mm:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F783EE06-CD15-4528-987C-36D3827C6299",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:belden:eagle_20_tofino_943_987-501-tx\\/tx_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5BE7527A-1642-47DE-9B63-1D014FDCAD8B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:belden:eagle_20_tofino_943_987-501-tx\\/tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A0AA7301-DDE2-4FD3-9118-4D4E7C2F6B8F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefea23f3f20_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8FCE4712-F43E-4999-8362-2F2DAED60FD2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefea23f3f20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E7760711-D753-4F29-B25F-557A55FB839D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefea23f3f21_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5AB2EA8E-567D-451B-9439-32158D07B263",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefea23f3f21:-:*:*:*:*:*:*:*",
"matchCriteriaId": "730B4CD5-4075-48EE-B3ED-1048E3C69E72",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:tcsefea23f3f22_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "428E6ECF-99BD-4E06-A8AC-6B121490242E",
"versionEndExcluding": "03.23",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:tcsefea23f3f22:-:*:*:*:*:*:*:*",
"matchCriteriaId": "75EA94E5-9D72-4E54-BBDF-8544EF774462",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick."
},
{
"lang": "es",
"value": "En Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 versiones anteriores a 03.23, TCSEFEA23F3F20/21, y Belden Tofino Xenon Security Appliance, los atacantes f\u00edsicamente pr\u00f3ximos pueden ejecutar c\u00f3digo por medio de un archivo dise\u00f1ado en una memoria USB"
}
],
"id": "CVE-2021-30061",
"lastModified": "2026-06-17T03:49:38.797",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-03T22:15:14.763",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.belden.com/support/security-assurance"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2021-30066 (GCVE-0-2021-30066)
Vulnerability from nvd – Published: 2022-04-03 22:01 – Updated: 2024-08-03 22:24
VLAI
EPSS
VEX
Summary
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/support/security-assurance | x_refsource_MISC |
| https://download.schneider-electric.com/files?p_D… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.400Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-03T22:01:59.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-30066",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/support/security-assurance",
"refsource": "MISC",
"url": "https://www.belden.com/support/security-assurance"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05",
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-30066",
"datePublished": "2022-04-03T22:01:59.000Z",
"dateReserved": "2021-04-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T22:24:59.400Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30065 (GCVE-0-2021-30065)
Vulnerability from nvd – Published: 2022-04-03 21:59 – Updated: 2024-08-03 22:24
VLAI
EPSS
VEX
Summary
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.
Severity
7.5 (High)
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/support/security-assurance | x_refsource_MISC |
| https://download.schneider-electric.com/files?p_D… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.526Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:N/A:N/C:N/I:H/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-03T21:59:18.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-30065",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:N/A:N/C:N/I:H/PR:N/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/support/security-assurance",
"refsource": "MISC",
"url": "https://www.belden.com/support/security-assurance"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05",
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-30065",
"datePublished": "2022-04-03T21:59:18.000Z",
"dateReserved": "2021-04-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T22:24:59.526Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30064 (GCVE-0-2021-30064)
Vulnerability from nvd – Published: 2022-04-03 21:56 – Updated: 2024-08-03 22:24
VLAI
EPSS
VEX
Summary
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/support/security-assurance | x_refsource_MISC |
| https://download.schneider-electric.com/files?p_D… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.323Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-03T21:56:29.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-30064",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/support/security-assurance",
"refsource": "MISC",
"url": "https://www.belden.com/support/security-assurance"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05",
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-30064",
"datePublished": "2022-04-03T21:56:29.000Z",
"dateReserved": "2021-04-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T22:24:59.323Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30063 (GCVE-0-2021-30063)
Vulnerability from nvd – Published: 2022-04-03 21:52 – Updated: 2024-08-03 22:24
VLAI
EPSS
VEX
Summary
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/support/security-assurance | x_refsource_MISC |
| https://download.schneider-electric.com/files?p_D… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.006Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-03T21:52:44.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-30063",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/support/security-assurance",
"refsource": "MISC",
"url": "https://www.belden.com/support/security-assurance"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05",
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-30063",
"datePublished": "2022-04-03T21:52:45.000Z",
"dateReserved": "2021-04-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T22:24:59.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30062 (GCVE-0-2021-30062)
Vulnerability from nvd – Published: 2022-04-03 21:49 – Updated: 2024-08-03 22:24
VLAI
EPSS
VEX
Summary
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/support/security-assurance | x_refsource_MISC |
| https://download.schneider-electric.com/files?p_D… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.372Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-03T21:49:39.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-30062",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/support/security-assurance",
"refsource": "MISC",
"url": "https://www.belden.com/support/security-assurance"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05",
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-30062",
"datePublished": "2022-04-03T21:49:39.000Z",
"dateReserved": "2021-04-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T22:24:59.372Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30061 (GCVE-0-2021-30061)
Vulnerability from nvd – Published: 2022-04-03 21:46 – Updated: 2024-08-03 22:24
VLAI
EPSS
VEX
Summary
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/support/security-assurance | x_refsource_MISC |
| https://download.schneider-electric.com/files?p_D… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.368Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-03T21:46:05.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-30061",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/support/security-assurance",
"refsource": "MISC",
"url": "https://www.belden.com/support/security-assurance"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05",
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-30061",
"datePublished": "2022-04-03T21:46:05.000Z",
"dateReserved": "2021-04-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T22:24:59.368Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30066 (GCVE-0-2021-30066)
Vulnerability from cvelistv5 – Published: 2022-04-03 22:01 – Updated: 2024-08-03 22:24
VLAI
EPSS
VEX
Summary
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/support/security-assurance | x_refsource_MISC |
| https://download.schneider-electric.com/files?p_D… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.400Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-03T22:01:59.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-30066",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/support/security-assurance",
"refsource": "MISC",
"url": "https://www.belden.com/support/security-assurance"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05",
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-30066",
"datePublished": "2022-04-03T22:01:59.000Z",
"dateReserved": "2021-04-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T22:24:59.400Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30065 (GCVE-0-2021-30065)
Vulnerability from cvelistv5 – Published: 2022-04-03 21:59 – Updated: 2024-08-03 22:24
VLAI
EPSS
VEX
Summary
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.
Severity
7.5 (High)
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/support/security-assurance | x_refsource_MISC |
| https://download.schneider-electric.com/files?p_D… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.526Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:N/A:N/C:N/I:H/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-03T21:59:18.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-30065",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:N/A:N/C:N/I:H/PR:N/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/support/security-assurance",
"refsource": "MISC",
"url": "https://www.belden.com/support/security-assurance"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05",
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-30065",
"datePublished": "2022-04-03T21:59:18.000Z",
"dateReserved": "2021-04-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T22:24:59.526Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30064 (GCVE-0-2021-30064)
Vulnerability from cvelistv5 – Published: 2022-04-03 21:56 – Updated: 2024-08-03 22:24
VLAI
EPSS
VEX
Summary
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/support/security-assurance | x_refsource_MISC |
| https://download.schneider-electric.com/files?p_D… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.323Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-03T21:56:29.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-30064",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/support/security-assurance",
"refsource": "MISC",
"url": "https://www.belden.com/support/security-assurance"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05",
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-30064",
"datePublished": "2022-04-03T21:56:29.000Z",
"dateReserved": "2021-04-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T22:24:59.323Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30063 (GCVE-0-2021-30063)
Vulnerability from cvelistv5 – Published: 2022-04-03 21:52 – Updated: 2024-08-03 22:24
VLAI
EPSS
VEX
Summary
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/support/security-assurance | x_refsource_MISC |
| https://download.schneider-electric.com/files?p_D… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.006Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-03T21:52:44.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-30063",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/support/security-assurance",
"refsource": "MISC",
"url": "https://www.belden.com/support/security-assurance"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05",
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-30063",
"datePublished": "2022-04-03T21:52:45.000Z",
"dateReserved": "2021-04-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T22:24:59.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30062 (GCVE-0-2021-30062)
Vulnerability from cvelistv5 – Published: 2022-04-03 21:49 – Updated: 2024-08-03 22:24
VLAI
EPSS
VEX
Summary
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/support/security-assurance | x_refsource_MISC |
| https://download.schneider-electric.com/files?p_D… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.372Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-03T21:49:39.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-30062",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/support/security-assurance",
"refsource": "MISC",
"url": "https://www.belden.com/support/security-assurance"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05",
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-30062",
"datePublished": "2022-04-03T21:49:39.000Z",
"dateReserved": "2021-04-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T22:24:59.372Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-30061 (GCVE-0-2021-30061)
Vulnerability from cvelistv5 – Published: 2022-04-03 21:46 – Updated: 2024-08-03 22:24
VLAI
EPSS
VEX
Summary
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.belden.com/support/security-assurance | x_refsource_MISC |
| https://download.schneider-electric.com/files?p_D… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T22:24:59.368Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-03T21:46:05.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.belden.com/support/security-assurance"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-30061",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.belden.com/support/security-assurance",
"refsource": "MISC",
"url": "https://www.belden.com/support/security-assurance"
},
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05",
"refsource": "CONFIRM",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-30061",
"datePublished": "2022-04-03T21:46:05.000Z",
"dateReserved": "2021-04-02T00:00:00.000Z",
"dateUpdated": "2024-08-03T22:24:59.368Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}