Search

Find a vulnerability

Search criteria

    18 vulnerabilities found for dir-655_firmware by dlink

    FKIE_CVE-2025-6158

    Vulnerability from fkie_nvd - Published: 2025-06-17 04:15 - Updated: 2026-06-17 10:01
    Summary
    A vulnerability classified as critical has been found in D-Link DIR-665 1.00. This affects the function sub_AC78 of the component HTTP POST Request Handler. The manipulation leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
    Impacted products
    Vendor Product Version
    dlink dir-655_firmware 1.00
    dlink dir-655 -

    {
      "affected": [
        {
          "affectedData": [
            {
              "modules": [
                "HTTP POST Request Handler"
              ],
              "product": "DIR-665",
              "vendor": "D-Link",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.00"
                }
              ]
            }
          ],
          "source": "cna@vuldb.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-655_firmware:1.00:*:*:*:*:*:*:*",
                  "matchCriteriaId": "53F6D738-BC5E-4BC7-9C48-A8536F8B5257",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-655:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86A9FA74-993E-47DC-B3E7-84D336950E81",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [
        {
          "sourceIdentifier": "cna@vuldb.com",
          "tags": [
            "unsupported-when-assigned"
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in D-Link DIR-665 1.00. This affects the function sub_AC78 of the component HTTP POST Request Handler. The manipulation leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer."
        },
        {
          "lang": "es",
          "value": "Se ha detectado una vulnerabilidad cr\u00edtica en D-Link DIR-665 1.00. Esta vulnerabilidad afecta a la funci\u00f3n sub_AC78 del componente HTTP POST Request Handler. La manipulaci\u00f3n provoca un desbordamiento del b\u00fafer en la pila. Es posible iniciar el ataque de forma remota. Se ha hecho p\u00fablico el exploit y puede que sea utilizado. Esta vulnerabilidad solo afecta a los productos que ya no reciben soporte del fabricante."
        }
      ],
      "id": "CVE-2025-6158",
      "lastModified": "2026-06-17T10:01:17.357",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 9.0,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "cna@vuldb.com",
            "type": "Secondary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 7.4,
              "baseSeverity": "HIGH",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "PROOF_OF_CONCEPT",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "LOW",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2025-6158",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-06-17T19:45:50.709647Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2025-06-17T04:15:55.407",
      "references": [
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/xiaobor123/vul-finds/tree/main/vul-find-dir665-dlink"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/xiaobor123/vul-finds/tree/main/vul-find-dir665-dlink#poc"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Permissions Required",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/?ctiid.312633"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/?id.312633"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://vuldb.com/?submit.593161"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "sourceIdentifier": "cna@vuldb.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            },
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2019-16920

    Vulnerability from fkie_nvd - Published: 2019-09-27 12:15 - Updated: 2026-06-17 02:22
    Summary
    Unauthenticated remote code execution occurs in D-Link products such as DIR-655C, DIR-866L, DIR-652, and DHP-1565. The issue occurs when the attacker sends an arbitrary input to a "PingTest" device common gateway interface that could lead to common injection. An attacker who successfully triggers the command injection could achieve full system compromise. Later, it was independently found that these are also affected: DIR-855L, DAP-1533, DIR-862L, DIR-615, DIR-835, and DIR-825.

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "cisaActionDue": "2022-04-15",
      "cisaExploitAdd": "2022-03-25",
      "cisaRequiredAction": "The impacted product is end-of-life and should be disconnected if still in use.",
      "cisaVulnerabilityName": "D-Link Multiple Routers Command Injection Vulnerability",
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-655_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "525853B4-1C30-4D96-AD4F-26FD77469B33",
                  "versionEndIncluding": "3.02b05",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-655:cx:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8F90F9E0-0F90-4AFD-868C-370882C47248",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-866l_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EA174575-0468-4AB1-A504-B5AA559D3219",
                  "versionEndIncluding": "1.03b04",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-866l:ax:*:*:*:*:*:*:*",
                  "matchCriteriaId": "52177D2B-D7F8-4351-A169-FDF6A5FBF44D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-652_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1147272F-0F23-4606-A84E-CA971414C65B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-652:ax:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2E4D52D3-71FD-4D29-881A-393B35F3DB65",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dhp-1565_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "369D2C8E-89F1-4E03-8DA0-BA2DB1245569",
                  "versionEndIncluding": "1.01",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dhp-1565:ax:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BAFB86EA-966B-4DB3-9B81-198878D76573",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-855l_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "239F0015-2834-4DBB-B115-58871D0FF764",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-855l:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7EB62BC4-69BC-40D7-A8E7-F5728B827250",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dap-1533_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB7D656D-47B5-4269-A155-741D60F818CD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dap-1533:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0D3E4627-940F-4859-BC67-B6229BC0AFD8",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-862l_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "380A4761-5474-4F52-A4EE-62844D5EE82C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-862l:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0552E33F-BB39-4701-B91A-1DB33992505C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-615_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8C55E6D4-820D-469F-A343-635A621C0D7C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-615:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2E92E959-C211-4979-A233-163BEFCF6F0D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-835_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FCFE0993-C19A-4C60-B8C6-E549D748537A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-835:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D1B91013-E79E-4076-916D-D52D6E417EA7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-825_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EEC49DA6-D1F4-4A2A-904E-907356F3C804",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-825:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7038F8A9-03F3-4442-B371-84801EF05447",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Unauthenticated remote code execution occurs in D-Link products such as DIR-655C, DIR-866L, DIR-652, and DHP-1565. The issue occurs when the attacker sends an arbitrary input to a \"PingTest\" device common gateway interface that could lead to common injection. An attacker who successfully triggers the command injection could achieve full system compromise. Later, it was independently found that these are also affected: DIR-855L, DAP-1533, DIR-862L, DIR-615, DIR-835, and DIR-825."
        },
        {
          "lang": "es",
          "value": "La ejecuci\u00f3n de c\u00f3digo remota no autenticada se presenta en productos D-Link tales como DIR-655C, DIR-866L, DIR-652, y DHP-1565. El problema se presenta cuando el atacante env\u00eda una entrada arbitraria hacia una interfaz de la puerta de enlace com\u00fan del dispositivo \"PingTest\" que podr\u00eda conllevar a una inyecci\u00f3n com\u00fan. Un atacante que activa con \u00e9xito la inyecci\u00f3n de comando podr\u00eda lograr un compromiso total del sistema. Despu\u00e9s, se descubri\u00f3 de manera independiente que estos tambi\u00e9n se ven afectados: DIR-855L, DAP-1533, DIR-862L, DIR-615, DIR-835 y DIR-825."
        }
      ],
      "id": "CVE-2019-16920",
      "lastModified": "2026-06-17T02:22:57.810",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 10.0,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2019-16920",
              "options": [
                {
                  "exploitation": "active"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-02-04T20:04:10.590560Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2019-09-27T12:15:10.017",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Broken Link",
            "Third Party Advisory"
          ],
          "url": "https://fortiguard.com/zeroday/FG-VD-19-117"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://medium.com/%4080vul/determine-the-device-model-affected-by-cve-2019-16920-by-zoomeye-bf6fec7f9bb3"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.kb.cert.org/vuls/id/766427"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://www.seebug.org/vuldb/ssvid-98079"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Broken Link",
            "Third Party Advisory"
          ],
          "url": "https://fortiguard.com/zeroday/FG-VD-19-117"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://medium.com/%4080vul/determine-the-device-model-affected-by-cve-2019-16920-by-zoomeye-bf6fec7f9bb3"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.kb.cert.org/vuls/id/766427"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://www.seebug.org/vuldb/ssvid-98079"
        },
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "tags": [
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-16920"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-78"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-78"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2019-13563

    Vulnerability from fkie_nvd - Published: 2019-07-11 15:15 - Updated: 2026-06-17 02:16

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-655_firmware:3.02b05:*:*:*:*:*:*:*",
                  "matchCriteriaId": "802545DF-DFA9-42E8-87EF-3FBA0BB58F96",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-655:c1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "48C3A684-A01B-4CFF-AD26-2EB753301F3C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow CSRF for the entire management console."
        },
        {
          "lang": "es",
          "value": "Los dispositivos DIR-655 C anterior a versi\u00f3n 3.02B05 BETA03 de D-Link, permiten una vulnerabilidad de tipo CSRF para toda la consola de administraci\u00f3n."
        }
      ],
      "id": "CVE-2019-13563",
      "lastModified": "2026-06-17T02:16:59.303",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-07-11T15:15:11.723",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/csrf.txt"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/csrf.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-352"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2019-13562

    Vulnerability from fkie_nvd - Published: 2019-07-11 15:15 - Updated: 2026-06-17 02:16

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-655_firmware:3.02b05:*:*:*:*:*:*:*",
                  "matchCriteriaId": "802545DF-DFA9-42E8-87EF-3FBA0BB58F96",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-655:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86A9FA74-993E-47DC-B3E7-84D336950E81",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow XSS, as demonstrated by the /www/ping_response.cgi ping_ipaddr parameter, the /www/ping6_response.cgi ping6_ipaddr parameter, and the /www/apply_sec.cgi html_response_return_page parameter."
        },
        {
          "lang": "es",
          "value": "Los dispositivos DIR-655 C anterior a versi\u00f3n 3.02B05 BETA03 de D-Link, permiten una vulnerabilidad de tipo XSS, como es demostrado por el par\u00e1metro ping_ipaddr del archivo /www/ping_response.cgi, el par\u00e1metro ping6_ipaddr del archivo /www/ping6_response.cgi, y el par\u00e1metro html_response_return_page del archivo /www/apply_sec.cgi."
        }
      ],
      "id": "CVE-2019-13562",
      "lastModified": "2026-06-17T02:16:59.167",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 2.7,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-07-11T15:15:11.660",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/crosssitescripting.txt"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/crosssitescripting.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-79"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2019-13561

    Vulnerability from fkie_nvd - Published: 2019-07-11 15:15 - Updated: 2026-06-17 02:16

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-655_firmware:3.02b05:*:*:*:*:*:*:*",
                  "matchCriteriaId": "802545DF-DFA9-42E8-87EF-3FBA0BB58F96",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-655:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86A9FA74-993E-47DC-B3E7-84D336950E81",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to execute arbitrary commands via shell metacharacters in the online_firmware_check.cgi check_fw_url parameter."
        },
        {
          "lang": "es",
          "value": "Los dispositivos DIR-655 C anterior a versi\u00f3n 3.02B05 BETA03 de D-Link, permiten que los atacantes remotos ejecuten comandos arbitrarios por medio de metacaracteres de shell en el par\u00e1metro check_fw_url del archivo online_firmware_check.cgi."
        }
      ],
      "id": "CVE-2019-13561",
      "lastModified": "2026-06-17T02:16:59.030",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 10.0,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-07-11T15:15:11.597",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/commandinjection.txt"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/commandinjection.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-78"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2019-13560

    Vulnerability from fkie_nvd - Published: 2019-07-11 15:15 - Updated: 2026-06-17 02:16

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:dlink:dir-655_firmware:3.02b05:*:*:*:*:*:*:*",
                  "matchCriteriaId": "802545DF-DFA9-42E8-87EF-3FBA0BB58F96",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:dlink:dir-655:c1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "48C3A684-A01B-4CFF-AD26-2EB753301F3C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to force a blank password via the apply_sec.cgi setup_wizard parameter."
        },
        {
          "lang": "es",
          "value": "Los dispositivos DIR-655 C anterior a versi\u00f3n 3.02B05 BETA03 de D-Link, permiten a los atacantes remotos forzar una contrase\u00f1a en blanco por medio del par\u00e1metro setup_wizard del archivo apply_sec.cgi."
        }
      ],
      "id": "CVE-2019-13560",
      "lastModified": "2026-06-17T02:16:58.890",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2019-07-11T15:15:11.520",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/setupwizard.txt"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/setupwizard.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-255"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2025-6158 (GCVE-0-2025-6158)

    Vulnerability from nvd – Published: 2025-06-17 03:31 – Updated: 2025-06-17 19:46 Unsupported When Assigned
    VLAI
    Title
    D-Link DIR-665 HTTP POST Request sub_AC78 stack-based overflow
    Summary
    A vulnerability classified as critical has been found in D-Link DIR-665 1.00. This affects the function sub_AC78 of the component HTTP POST Request Handler. The manipulation leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-17 19:45 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3821 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    D-Link DIR-665 Affected: 1.00
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-6158",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-17T19:45:50.709647Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-17T19:46:27.259Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "HTTP POST Request Handler"
              ],
              "product": "DIR-665",
              "vendor": "D-Link",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.00"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "xiaobor123 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical has been found in D-Link DIR-665 1.00. This affects the function sub_AC78 of the component HTTP POST Request Handler. The manipulation leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer."
            },
            {
              "lang": "de",
              "value": "Es wurde eine Schwachstelle in D-Link DIR-665 1.00 entdeckt. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion sub_AC78 der Komponente HTTP POST Request Handler. Mit der Manipulation mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-17T03:31:05.773Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-312633 | D-Link DIR-665 HTTP POST Request sub_AC78 stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.312633"
            },
            {
              "name": "VDB-312633 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.312633"
            },
            {
              "name": "Submit #593161 | dlink DIR-665 1.00 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.593161"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/xiaobor123/vul-finds/tree/main/vul-find-dir665-dlink"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/xiaobor123/vul-finds/tree/main/vul-find-dir665-dlink#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.dlink.com/"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-15T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-15T21:03:40.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "D-Link DIR-665 HTTP POST Request sub_AC78 stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-6158",
        "datePublished": "2025-06-17T03:31:05.773Z",
        "dateReserved": "2025-06-15T18:58:28.712Z",
        "dateUpdated": "2025-06-17T19:46:27.259Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-16920 (GCVE-0-2019-16920)

    Vulnerability from nvd – Published: 2019-09-27 11:34 – Updated: 2025-10-21 23:45
    VLAI CISA Shadowserver Previdian
    Summary
    Unauthenticated remote code execution occurs in D-Link products such as DIR-655C, DIR-866L, DIR-652, and DHP-1565. The issue occurs when the attacker sends an arbitrary input to a "PingTest" device common gateway interface that could lead to common injection. An attacker who successfully triggers the command injection could achieve full system compromise. Later, it was independently found that these are also affected: DIR-855L, DAP-1533, DIR-862L, DIR-615, DIR-835, and DIR-825.
    SSVC
    Exploitation: active Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-02-04 20:04 UTC
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T01:24:48.593Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://fortiguard.com/zeroday/FG-VD-19-117"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.seebug.org/vuldb/ssvid-98079"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://medium.com/%4080vul/determine-the-device-model-affected-by-cve-2019-16920-by-zoomeye-bf6fec7f9bb3"
              },
              {
                "name": "VU#766427",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "https://www.kb.cert.org/vuls/id/766427"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-16920",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-04T20:04:10.590560Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2022-03-25",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-16920"
                  },
                  "type": "kev"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-21T23:45:29.886Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-16920"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2022-03-25T00:00:00.000Z",
                "value": "CVE-2019-16920 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Unauthenticated remote code execution occurs in D-Link products such as DIR-655C, DIR-866L, DIR-652, and DHP-1565. The issue occurs when the attacker sends an arbitrary input to a \"PingTest\" device common gateway interface that could lead to common injection. An attacker who successfully triggers the command injection could achieve full system compromise. Later, it was independently found that these are also affected: DIR-855L, DAP-1533, DIR-862L, DIR-615, DIR-835, and DIR-825."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-10-23T19:06:26.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://fortiguard.com/zeroday/FG-VD-19-117"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.seebug.org/vuldb/ssvid-98079"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://medium.com/%4080vul/determine-the-device-model-affected-by-cve-2019-16920-by-zoomeye-bf6fec7f9bb3"
            },
            {
              "name": "VU#766427",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "https://www.kb.cert.org/vuls/id/766427"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-16920",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Unauthenticated remote code execution occurs in D-Link products such as DIR-655C, DIR-866L, DIR-652, and DHP-1565. The issue occurs when the attacker sends an arbitrary input to a \"PingTest\" device common gateway interface that could lead to common injection. An attacker who successfully triggers the command injection could achieve full system compromise. Later, it was independently found that these are also affected: DIR-855L, DAP-1533, DIR-862L, DIR-615, DIR-835, and DIR-825."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://fortiguard.com/zeroday/FG-VD-19-117",
                  "refsource": "MISC",
                  "url": "https://fortiguard.com/zeroday/FG-VD-19-117"
                },
                {
                  "name": "https://www.seebug.org/vuldb/ssvid-98079",
                  "refsource": "MISC",
                  "url": "https://www.seebug.org/vuldb/ssvid-98079"
                },
                {
                  "name": "https://medium.com/@80vul/determine-the-device-model-affected-by-cve-2019-16920-by-zoomeye-bf6fec7f9bb3",
                  "refsource": "MISC",
                  "url": "https://medium.com/@80vul/determine-the-device-model-affected-by-cve-2019-16920-by-zoomeye-bf6fec7f9bb3"
                },
                {
                  "name": "VU#766427",
                  "refsource": "CERT-VN",
                  "url": "https://www.kb.cert.org/vuls/id/766427"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-16920",
        "datePublished": "2019-09-27T11:34:12.000Z",
        "dateReserved": "2019-09-27T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:45:29.886Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13563 (GCVE-0-2019-13563)

    Vulnerability from nvd – Published: 2019-07-11 14:59 – Updated: 2024-08-04 23:57
    VLAI
    Summary
    D-Link DIR-655 C devices before 3.02B05 BETA03 allow CSRF for the entire management console.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:57:39.305Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/csrf.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow CSRF for the entire management console."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-11T14:59:38.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/csrf.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-13563",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow CSRF for the entire management console."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
                },
                {
                  "name": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf",
                  "refsource": "MISC",
                  "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
                },
                {
                  "name": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/csrf.txt",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/csrf.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-13563",
        "datePublished": "2019-07-11T14:59:38.000Z",
        "dateReserved": "2019-07-11T00:00:00.000Z",
        "dateUpdated": "2024-08-04T23:57:39.305Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13562 (GCVE-0-2019-13562)

    Vulnerability from nvd – Published: 2019-07-11 14:59 – Updated: 2024-08-04 23:57
    VLAI
    Summary
    D-Link DIR-655 C devices before 3.02B05 BETA03 allow XSS, as demonstrated by the /www/ping_response.cgi ping_ipaddr parameter, the /www/ping6_response.cgi ping6_ipaddr parameter, and the /www/apply_sec.cgi html_response_return_page parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:57:39.385Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/crosssitescripting.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow XSS, as demonstrated by the /www/ping_response.cgi ping_ipaddr parameter, the /www/ping6_response.cgi ping6_ipaddr parameter, and the /www/apply_sec.cgi html_response_return_page parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-11T14:59:27.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/crosssitescripting.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-13562",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow XSS, as demonstrated by the /www/ping_response.cgi ping_ipaddr parameter, the /www/ping6_response.cgi ping6_ipaddr parameter, and the /www/apply_sec.cgi html_response_return_page parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
                },
                {
                  "name": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf",
                  "refsource": "MISC",
                  "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
                },
                {
                  "name": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/crosssitescripting.txt",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/crosssitescripting.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-13562",
        "datePublished": "2019-07-11T14:59:27.000Z",
        "dateReserved": "2019-07-11T00:00:00.000Z",
        "dateUpdated": "2024-08-04T23:57:39.385Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13561 (GCVE-0-2019-13561)

    Vulnerability from nvd – Published: 2019-07-11 14:59 – Updated: 2024-08-04 23:57
    VLAI
    Summary
    D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to execute arbitrary commands via shell metacharacters in the online_firmware_check.cgi check_fw_url parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:57:39.390Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/commandinjection.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to execute arbitrary commands via shell metacharacters in the online_firmware_check.cgi check_fw_url parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-11T14:59:14.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/commandinjection.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-13561",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to execute arbitrary commands via shell metacharacters in the online_firmware_check.cgi check_fw_url parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
                },
                {
                  "name": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf",
                  "refsource": "MISC",
                  "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
                },
                {
                  "name": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/commandinjection.txt",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/commandinjection.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-13561",
        "datePublished": "2019-07-11T14:59:14.000Z",
        "dateReserved": "2019-07-11T00:00:00.000Z",
        "dateUpdated": "2024-08-04T23:57:39.390Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13560 (GCVE-0-2019-13560)

    Vulnerability from nvd – Published: 2019-07-11 14:59 – Updated: 2024-08-04 23:57
    VLAI
    Summary
    D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to force a blank password via the apply_sec.cgi setup_wizard parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:57:39.428Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/setupwizard.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to force a blank password via the apply_sec.cgi setup_wizard parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-11T14:59:02.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/setupwizard.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-13560",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to force a blank password via the apply_sec.cgi setup_wizard parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
                },
                {
                  "name": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf",
                  "refsource": "MISC",
                  "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
                },
                {
                  "name": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/setupwizard.txt",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/setupwizard.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-13560",
        "datePublished": "2019-07-11T14:59:02.000Z",
        "dateReserved": "2019-07-11T00:00:00.000Z",
        "dateUpdated": "2024-08-04T23:57:39.428Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-6158 (GCVE-0-2025-6158)

    Vulnerability from cvelistv5 – Published: 2025-06-17 03:31 – Updated: 2025-06-17 19:46 Unsupported When Assigned
    VLAI
    Title
    D-Link DIR-665 HTTP POST Request sub_AC78 stack-based overflow
    Summary
    A vulnerability classified as critical has been found in D-Link DIR-665 1.00. This affects the function sub_AC78 of the component HTTP POST Request Handler. The manipulation leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-17 19:45 UTC
    CWE
    Assigner
    VulDB CNA under the mitre root
    CNA scorecard B 83/100 over 3821 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    D-Link DIR-665 Affected: 1.00
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-6158",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-17T19:45:50.709647Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-17T19:46:27.259Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "HTTP POST Request Handler"
              ],
              "product": "DIR-665",
              "vendor": "D-Link",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.00"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "xiaobor123 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as critical has been found in D-Link DIR-665 1.00. This affects the function sub_AC78 of the component HTTP POST Request Handler. The manipulation leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer."
            },
            {
              "lang": "de",
              "value": "Es wurde eine Schwachstelle in D-Link DIR-665 1.00 entdeckt. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion sub_AC78 der Komponente HTTP POST Request Handler. Mit der Manipulation mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-17T03:31:05.773Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-312633 | D-Link DIR-665 HTTP POST Request sub_AC78 stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.312633"
            },
            {
              "name": "VDB-312633 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.312633"
            },
            {
              "name": "Submit #593161 | dlink DIR-665 1.00 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.593161"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/xiaobor123/vul-finds/tree/main/vul-find-dir665-dlink"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/xiaobor123/vul-finds/tree/main/vul-find-dir665-dlink#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.dlink.com/"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2025-06-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2025-06-15T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2025-06-15T21:03:40.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "D-Link DIR-665 HTTP POST Request sub_AC78 stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2025-6158",
        "datePublished": "2025-06-17T03:31:05.773Z",
        "dateReserved": "2025-06-15T18:58:28.712Z",
        "dateUpdated": "2025-06-17T19:46:27.259Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-16920 (GCVE-0-2019-16920)

    Vulnerability from cvelistv5 – Published: 2019-09-27 11:34 – Updated: 2025-10-21 23:45
    VLAI CISA Shadowserver Previdian
    Summary
    Unauthenticated remote code execution occurs in D-Link products such as DIR-655C, DIR-866L, DIR-652, and DHP-1565. The issue occurs when the attacker sends an arbitrary input to a "PingTest" device common gateway interface that could lead to common injection. An attacker who successfully triggers the command injection could achieve full system compromise. Later, it was independently found that these are also affected: DIR-855L, DAP-1533, DIR-862L, DIR-615, DIR-835, and DIR-825.
    SSVC
    Exploitation: active Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-02-04 20:04 UTC
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T01:24:48.593Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://fortiguard.com/zeroday/FG-VD-19-117"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.seebug.org/vuldb/ssvid-98079"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://medium.com/%4080vul/determine-the-device-model-affected-by-cve-2019-16920-by-zoomeye-bf6fec7f9bb3"
              },
              {
                "name": "VU#766427",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "https://www.kb.cert.org/vuls/id/766427"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-16920",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-04T20:04:10.590560Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2022-03-25",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-16920"
                  },
                  "type": "kev"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-10-21T23:45:29.886Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-16920"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2022-03-25T00:00:00.000Z",
                "value": "CVE-2019-16920 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Unauthenticated remote code execution occurs in D-Link products such as DIR-655C, DIR-866L, DIR-652, and DHP-1565. The issue occurs when the attacker sends an arbitrary input to a \"PingTest\" device common gateway interface that could lead to common injection. An attacker who successfully triggers the command injection could achieve full system compromise. Later, it was independently found that these are also affected: DIR-855L, DAP-1533, DIR-862L, DIR-615, DIR-835, and DIR-825."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-10-23T19:06:26.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://fortiguard.com/zeroday/FG-VD-19-117"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.seebug.org/vuldb/ssvid-98079"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://medium.com/%4080vul/determine-the-device-model-affected-by-cve-2019-16920-by-zoomeye-bf6fec7f9bb3"
            },
            {
              "name": "VU#766427",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "https://www.kb.cert.org/vuls/id/766427"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-16920",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Unauthenticated remote code execution occurs in D-Link products such as DIR-655C, DIR-866L, DIR-652, and DHP-1565. The issue occurs when the attacker sends an arbitrary input to a \"PingTest\" device common gateway interface that could lead to common injection. An attacker who successfully triggers the command injection could achieve full system compromise. Later, it was independently found that these are also affected: DIR-855L, DAP-1533, DIR-862L, DIR-615, DIR-835, and DIR-825."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://fortiguard.com/zeroday/FG-VD-19-117",
                  "refsource": "MISC",
                  "url": "https://fortiguard.com/zeroday/FG-VD-19-117"
                },
                {
                  "name": "https://www.seebug.org/vuldb/ssvid-98079",
                  "refsource": "MISC",
                  "url": "https://www.seebug.org/vuldb/ssvid-98079"
                },
                {
                  "name": "https://medium.com/@80vul/determine-the-device-model-affected-by-cve-2019-16920-by-zoomeye-bf6fec7f9bb3",
                  "refsource": "MISC",
                  "url": "https://medium.com/@80vul/determine-the-device-model-affected-by-cve-2019-16920-by-zoomeye-bf6fec7f9bb3"
                },
                {
                  "name": "VU#766427",
                  "refsource": "CERT-VN",
                  "url": "https://www.kb.cert.org/vuls/id/766427"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-16920",
        "datePublished": "2019-09-27T11:34:12.000Z",
        "dateReserved": "2019-09-27T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:45:29.886Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13563 (GCVE-0-2019-13563)

    Vulnerability from cvelistv5 – Published: 2019-07-11 14:59 – Updated: 2024-08-04 23:57
    VLAI
    Summary
    D-Link DIR-655 C devices before 3.02B05 BETA03 allow CSRF for the entire management console.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:57:39.305Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/csrf.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow CSRF for the entire management console."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-11T14:59:38.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/csrf.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-13563",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow CSRF for the entire management console."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
                },
                {
                  "name": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf",
                  "refsource": "MISC",
                  "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
                },
                {
                  "name": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/csrf.txt",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/csrf.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-13563",
        "datePublished": "2019-07-11T14:59:38.000Z",
        "dateReserved": "2019-07-11T00:00:00.000Z",
        "dateUpdated": "2024-08-04T23:57:39.305Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13562 (GCVE-0-2019-13562)

    Vulnerability from cvelistv5 – Published: 2019-07-11 14:59 – Updated: 2024-08-04 23:57
    VLAI
    Summary
    D-Link DIR-655 C devices before 3.02B05 BETA03 allow XSS, as demonstrated by the /www/ping_response.cgi ping_ipaddr parameter, the /www/ping6_response.cgi ping6_ipaddr parameter, and the /www/apply_sec.cgi html_response_return_page parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:57:39.385Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/crosssitescripting.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow XSS, as demonstrated by the /www/ping_response.cgi ping_ipaddr parameter, the /www/ping6_response.cgi ping6_ipaddr parameter, and the /www/apply_sec.cgi html_response_return_page parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-11T14:59:27.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/crosssitescripting.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-13562",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow XSS, as demonstrated by the /www/ping_response.cgi ping_ipaddr parameter, the /www/ping6_response.cgi ping6_ipaddr parameter, and the /www/apply_sec.cgi html_response_return_page parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
                },
                {
                  "name": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf",
                  "refsource": "MISC",
                  "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
                },
                {
                  "name": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/crosssitescripting.txt",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/crosssitescripting.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-13562",
        "datePublished": "2019-07-11T14:59:27.000Z",
        "dateReserved": "2019-07-11T00:00:00.000Z",
        "dateUpdated": "2024-08-04T23:57:39.385Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13561 (GCVE-0-2019-13561)

    Vulnerability from cvelistv5 – Published: 2019-07-11 14:59 – Updated: 2024-08-04 23:57
    VLAI
    Summary
    D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to execute arbitrary commands via shell metacharacters in the online_firmware_check.cgi check_fw_url parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:57:39.390Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/commandinjection.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to execute arbitrary commands via shell metacharacters in the online_firmware_check.cgi check_fw_url parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-11T14:59:14.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/commandinjection.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-13561",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to execute arbitrary commands via shell metacharacters in the online_firmware_check.cgi check_fw_url parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
                },
                {
                  "name": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf",
                  "refsource": "MISC",
                  "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
                },
                {
                  "name": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/commandinjection.txt",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/commandinjection.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-13561",
        "datePublished": "2019-07-11T14:59:14.000Z",
        "dateReserved": "2019-07-11T00:00:00.000Z",
        "dateUpdated": "2024-08-04T23:57:39.390Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-13560 (GCVE-0-2019-13560)

    Vulnerability from cvelistv5 – Published: 2019-07-11 14:59 – Updated: 2024-08-04 23:57
    VLAI
    Summary
    D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to force a blank password via the apply_sec.cgi setup_wizard parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2045 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T23:57:39.428Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/setupwizard.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to force a blank password via the apply_sec.cgi setup_wizard parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-07-11T14:59:02.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/setupwizard.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-13560",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to force a blank password via the apply_sec.cgi setup_wizard parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/us/about-us/newsroom-and-events/blog/2019/july/the-d-link-dir-655c-from-nothing-to-rce/"
                },
                {
                  "name": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf",
                  "refsource": "MISC",
                  "url": "ftp://ftp2.dlink.com/SECURITY_ADVISEMENTS/DIR-655/REVC/DIR-655_REVC_RELEASE_NOTES_v3.02B05_BETA03.pdf"
                },
                {
                  "name": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/setupwizard.txt",
                  "refsource": "MISC",
                  "url": "https://www.nccgroup.trust/contentassets/7188fe7f130846ffa31827fc1661d120/setupwizard.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-13560",
        "datePublished": "2019-07-11T14:59:02.000Z",
        "dateReserved": "2019-07-11T00:00:00.000Z",
        "dateUpdated": "2024-08-04T23:57:39.428Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }