CVE-2017-16751 (GCVE-0-2017-16751)

Vulnerability from nvd – Published: 2018-03-15 23:00 – Updated: 2024-08-05 20:35
VLAI?
Summary
A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Stack-based buffer overflow vulnerabilities caused by processing specially crafted .dpb files may allow an attacker to remotely execute arbitrary code.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Delta Electronics Delta Industrial Automation Screen Editor Affected: Delta Electronics Delta Industrial Automation Screen Editor
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:20.458Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
          },
          {
            "name": "102426",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102426"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Delta Electronics Delta Industrial Automation Screen Editor",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Delta Electronics Delta Industrial Automation Screen Editor"
            }
          ]
        }
      ],
      "datePublic": "2018-03-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Stack-based buffer overflow vulnerabilities caused by processing specially crafted .dpb files may allow an attacker to remotely execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-16T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
        },
        {
          "name": "102426",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102426"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-16751",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Delta Electronics Delta Industrial Automation Screen Editor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Delta Electronics Delta Industrial Automation Screen Editor"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Stack-based buffer overflow vulnerabilities caused by processing specially crafted .dpb files may allow an attacker to remotely execute arbitrary code."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
            },
            {
              "name": "102426",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102426"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-16751",
    "datePublished": "2018-03-15T23:00:00",
    "dateReserved": "2017-11-09T00:00:00",
    "dateUpdated": "2024-08-05T20:35:20.458Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-16749 (GCVE-0-2017-16749)

Vulnerability from nvd – Published: 2018-03-15 23:00 – Updated: 2024-08-05 20:35
VLAI?
Summary
A Use-after-Free issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files could exploit a use-after-free vulnerability.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Delta Electronics Delta Industrial Automation Screen Editor Affected: Delta Electronics Delta Industrial Automation Screen Editor
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:20.327Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
          },
          {
            "name": "102426",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102426"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Delta Electronics Delta Industrial Automation Screen Editor",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Delta Electronics Delta Industrial Automation Screen Editor"
            }
          ]
        }
      ],
      "datePublic": "2018-03-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Use-after-Free issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files could exploit a use-after-free vulnerability."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "CWE-416",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-16T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
        },
        {
          "name": "102426",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102426"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-16749",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Delta Electronics Delta Industrial Automation Screen Editor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Delta Electronics Delta Industrial Automation Screen Editor"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Use-after-Free issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files could exploit a use-after-free vulnerability."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-416"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
            },
            {
              "name": "102426",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102426"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-16749",
    "datePublished": "2018-03-15T23:00:00",
    "dateReserved": "2017-11-09T00:00:00",
    "dateUpdated": "2024-08-05T20:35:20.327Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-16747 (GCVE-0-2017-16747)

Vulnerability from nvd – Published: 2018-03-15 23:00 – Updated: 2024-08-05 20:35
VLAI?
Summary
An Out-of-bounds Write issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files may cause the system to write outside the intended buffer area.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Delta Electronics Delta Industrial Automation Screen Editor Affected: Delta Electronics Delta Industrial Automation Screen Editor
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:20.329Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
          },
          {
            "name": "102426",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102426"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Delta Electronics Delta Industrial Automation Screen Editor",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Delta Electronics Delta Industrial Automation Screen Editor"
            }
          ]
        }
      ],
      "datePublic": "2018-03-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Out-of-bounds Write issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files may cause the system to write outside the intended buffer area."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-16T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
        },
        {
          "name": "102426",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102426"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-16747",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Delta Electronics Delta Industrial Automation Screen Editor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Delta Electronics Delta Industrial Automation Screen Editor"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Out-of-bounds Write issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files may cause the system to write outside the intended buffer area."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
            },
            {
              "name": "102426",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102426"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-16747",
    "datePublished": "2018-03-15T23:00:00",
    "dateReserved": "2017-11-09T00:00:00",
    "dateUpdated": "2024-08-05T20:35:20.329Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-16745 (GCVE-0-2017-16745)

Vulnerability from nvd – Published: 2018-03-15 23:00 – Updated: 2024-08-05 20:35
VLAI?
Summary
A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type ('type confusion') vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Delta Electronics Delta Industrial Automation Screen Editor Affected: Delta Electronics Delta Industrial Automation Screen Editor
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:20.911Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
          },
          {
            "name": "102426",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102426"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Delta Electronics Delta Industrial Automation Screen Editor",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Delta Electronics Delta Industrial Automation Screen Editor"
            }
          ]
        }
      ],
      "datePublic": "2018-03-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type (\u0027type confusion\u0027) vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-16T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
        },
        {
          "name": "102426",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102426"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-16745",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Delta Electronics Delta Industrial Automation Screen Editor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Delta Electronics Delta Industrial Automation Screen Editor"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type (\u0027type confusion\u0027) vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-843"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
            },
            {
              "name": "102426",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102426"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-16745",
    "datePublished": "2018-03-15T23:00:00",
    "dateReserved": "2017-11-09T00:00:00",
    "dateUpdated": "2024-08-05T20:35:20.911Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-16751 (GCVE-0-2017-16751)

Vulnerability from cvelistv5 – Published: 2018-03-15 23:00 – Updated: 2024-08-05 20:35
VLAI?
Summary
A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Stack-based buffer overflow vulnerabilities caused by processing specially crafted .dpb files may allow an attacker to remotely execute arbitrary code.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Delta Electronics Delta Industrial Automation Screen Editor Affected: Delta Electronics Delta Industrial Automation Screen Editor
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:20.458Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
          },
          {
            "name": "102426",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102426"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Delta Electronics Delta Industrial Automation Screen Editor",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Delta Electronics Delta Industrial Automation Screen Editor"
            }
          ]
        }
      ],
      "datePublic": "2018-03-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Stack-based buffer overflow vulnerabilities caused by processing specially crafted .dpb files may allow an attacker to remotely execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-16T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
        },
        {
          "name": "102426",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102426"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-16751",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Delta Electronics Delta Industrial Automation Screen Editor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Delta Electronics Delta Industrial Automation Screen Editor"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Stack-based buffer overflow vulnerabilities caused by processing specially crafted .dpb files may allow an attacker to remotely execute arbitrary code."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
            },
            {
              "name": "102426",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102426"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-16751",
    "datePublished": "2018-03-15T23:00:00",
    "dateReserved": "2017-11-09T00:00:00",
    "dateUpdated": "2024-08-05T20:35:20.458Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-16747 (GCVE-0-2017-16747)

Vulnerability from cvelistv5 – Published: 2018-03-15 23:00 – Updated: 2024-08-05 20:35
VLAI?
Summary
An Out-of-bounds Write issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files may cause the system to write outside the intended buffer area.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Delta Electronics Delta Industrial Automation Screen Editor Affected: Delta Electronics Delta Industrial Automation Screen Editor
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:20.329Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
          },
          {
            "name": "102426",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102426"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Delta Electronics Delta Industrial Automation Screen Editor",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Delta Electronics Delta Industrial Automation Screen Editor"
            }
          ]
        }
      ],
      "datePublic": "2018-03-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Out-of-bounds Write issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files may cause the system to write outside the intended buffer area."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-16T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
        },
        {
          "name": "102426",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102426"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-16747",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Delta Electronics Delta Industrial Automation Screen Editor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Delta Electronics Delta Industrial Automation Screen Editor"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Out-of-bounds Write issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files may cause the system to write outside the intended buffer area."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
            },
            {
              "name": "102426",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102426"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-16747",
    "datePublished": "2018-03-15T23:00:00",
    "dateReserved": "2017-11-09T00:00:00",
    "dateUpdated": "2024-08-05T20:35:20.329Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-16745 (GCVE-0-2017-16745)

Vulnerability from cvelistv5 – Published: 2018-03-15 23:00 – Updated: 2024-08-05 20:35
VLAI?
Summary
A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type ('type confusion') vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Delta Electronics Delta Industrial Automation Screen Editor Affected: Delta Electronics Delta Industrial Automation Screen Editor
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:20.911Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
          },
          {
            "name": "102426",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102426"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Delta Electronics Delta Industrial Automation Screen Editor",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Delta Electronics Delta Industrial Automation Screen Editor"
            }
          ]
        }
      ],
      "datePublic": "2018-03-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type (\u0027type confusion\u0027) vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-16T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
        },
        {
          "name": "102426",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102426"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-16745",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Delta Electronics Delta Industrial Automation Screen Editor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Delta Electronics Delta Industrial Automation Screen Editor"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type (\u0027type confusion\u0027) vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-843"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
            },
            {
              "name": "102426",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102426"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-16745",
    "datePublished": "2018-03-15T23:00:00",
    "dateReserved": "2017-11-09T00:00:00",
    "dateUpdated": "2024-08-05T20:35:20.911Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-16749 (GCVE-0-2017-16749)

Vulnerability from cvelistv5 – Published: 2018-03-15 23:00 – Updated: 2024-08-05 20:35
VLAI?
Summary
A Use-after-Free issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files could exploit a use-after-free vulnerability.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Delta Electronics Delta Industrial Automation Screen Editor Affected: Delta Electronics Delta Industrial Automation Screen Editor
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:20.327Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
          },
          {
            "name": "102426",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102426"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Delta Electronics Delta Industrial Automation Screen Editor",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Delta Electronics Delta Industrial Automation Screen Editor"
            }
          ]
        }
      ],
      "datePublic": "2018-03-15T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Use-after-Free issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files could exploit a use-after-free vulnerability."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-416",
              "description": "CWE-416",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-16T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
        },
        {
          "name": "102426",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102426"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-16749",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Delta Electronics Delta Industrial Automation Screen Editor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Delta Electronics Delta Industrial Automation Screen Editor"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Use-after-Free issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. Specially crafted .dpb files could exploit a use-after-free vulnerability."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-416"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01"
            },
            {
              "name": "102426",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102426"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-16749",
    "datePublished": "2018-03-15T23:00:00",
    "dateReserved": "2017-11-09T00:00:00",
    "dateUpdated": "2024-08-05T20:35:20.327Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}