CVE-2023-46102 (GCVE-0-2023-46102)
Vulnerability from nvd – Published: 2023-10-25 14:19 – Updated: 2024-09-11 13:49
VLAI?
Summary
The Android Client application, when enrolled to the AppHub server, connects to an MQTT
broker to exchange messages and receive commands to execute on the HMI device.
The protocol builds on top of MQTT to implement the remote management of the device is encrypted with a hard-coded DES symmetric key, that can be retrieved reversing both the Android Client application and the server-side web application.
This issue allows an attacker able to control a malicious MQTT broker on the same subnet
network of the device, to craft malicious messages and send them to the HMI device, executing arbitrary commands on the device itself.
Severity ?
8.8 (High)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch Rexroth AG | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.622Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:boschrexrothag:ctrl_hmi_web_panel-wr21_\\(wr2110\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrl_hmi_web_panel-wr21_\\(wr2110\\)",
"vendor": "boschrexrothag",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:boschrexrothag:ctrl_hmi_web_panel-wr21_\\(wr2115\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrl_hmi_web_panel-wr21_\\(wr2115\\)",
"vendor": "boschrexrothag",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:boschrexrothag:ctrl_hmi_web_panel-wr21_\\(wr2107\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrl_hmi_web_panel-wr21_\\(wr2107\\)",
"vendor": "boschrexrothag",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-46102",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T13:45:20.593751Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T13:49:04.787Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Android Client application, when enrolled to the AppHub server, connects to an MQTT\r\nbroker to exchange messages and receive commands to execute on the HMI device.\r\nThe protocol builds on top of MQTT to implement the remote management of the device is encrypted with a hard-coded DES symmetric key, that can be retrieved reversing both the Android Client application and the server-side web application.\r\n\r\n\r\nThis issue allows an attacker able to control a malicious MQTT broker on the same subnet\r\nnetwork of the device, to craft malicious messages and send them to the HMI device, executing arbitrary commands on the device itself."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:19:20.107Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-46102",
"datePublished": "2023-10-25T14:19:20.107Z",
"dateReserved": "2023-10-18T09:35:22.530Z",
"dateUpdated": "2024-09-11T13:49:04.787Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-45851 (GCVE-0-2023-45851)
Vulnerability from nvd – Published: 2023-10-25 14:18 – Updated: 2024-09-11 18:06
VLAI?
Summary
The Android Client application, when enrolled to the AppHub server,connects to an MQTT broker without enforcing any server authentication.
This issue allows an attacker to force the Android Client application to connect to a malicious MQTT broker, enabling it to send fake messages to the HMI device
Severity ?
8.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch Rexroth AG | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:29:32.293Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2107",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "RC7(Build date 20231107)",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-45851",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T16:00:27.264096Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T18:06:40.524Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Android Client application, when enrolled to the AppHub server,connects to an MQTT broker without enforcing any server authentication.\u00a0\r\n\r\n\r\nThis issue allows an attacker to force the Android Client application to connect to a malicious MQTT broker, enabling it to send fake messages to the HMI device"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:18:08.811Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-45851",
"datePublished": "2023-10-25T14:18:08.811Z",
"dateReserved": "2023-10-18T09:35:22.524Z",
"dateUpdated": "2024-09-11T18:06:40.524Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-45844 (GCVE-0-2023-45844)
Vulnerability from nvd – Published: 2023-10-25 13:07 – Updated: 2024-09-10 20:24
VLAI?
Summary
The vulnerability allows a low privileged user that have access to the device when locked in Kiosk mode to install an arbitrary Android application and leverage it to have access to critical device settings such as the device power management or eventually the device secure settings (ADB debug).
Severity ?
7.3 (High)
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rexroth | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:29:32.423Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:rexroth:ctrlx_hmi_web_panel_wr21\\/wr2107\\/:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr21\\/wr2107\\/",
"vendor": "rexroth",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:rexroth:ctrlx_hmi_web_panel_wr21\\/wr2110\\/:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr21\\/wr2110\\/",
"vendor": "rexroth",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:rexroth:ctrlx_hmi_web_panel_wr21\\/wr2115\\/:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr21\\/wr2115\\/",
"vendor": "rexroth",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-45844",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T20:05:44.966105Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T20:24:25.472Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability allows a low privileged user that have access to the device when locked in Kiosk mode to install an arbitrary Android application and leverage it to have access to critical device settings such as the device power management or eventually the device secure settings (ADB debug)."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T13:07:15.053Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-45844",
"datePublished": "2023-10-25T13:07:15.053Z",
"dateReserved": "2023-10-18T09:35:22.486Z",
"dateUpdated": "2024-09-10T20:24:25.472Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-45321 (GCVE-0-2023-45321)
Vulnerability from nvd – Published: 2023-10-25 14:16 – Updated: 2024-09-11 18:11
VLAI?
Summary
The Android Client application, when enrolled with the define method 1 (the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user. Due to the lack of encryption of HTTP,this issue allows an attacker placed in the same subnet network of the HMI device to intercept username and password necessary to authenticate to the MQTT server responsible to implement the remote management protocol.
Severity ?
8.3 (High)
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch Rexroth AG | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:21:15.404Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2107",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "RC7(Build date 20231107)",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-45321",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T16:00:25.907168Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T18:11:00.080Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Android Client application, when enrolled with the define method 1 (the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user. Due to the lack of encryption of HTTP,this issue allows an attacker placed in the same subnet network of the HMI device to intercept username and password necessary to authenticate to the MQTT server responsible to implement the remote management protocol."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:16:41.097Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-45321",
"datePublished": "2023-10-25T14:16:41.097Z",
"dateReserved": "2023-10-18T09:35:22.518Z",
"dateUpdated": "2024-09-11T18:11:00.080Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-45220 (GCVE-0-2023-45220)
Vulnerability from nvd – Published: 2023-10-25 14:15 – Updated: 2024-09-11 18:11
VLAI?
Summary
The Android Client application, when enrolled with the define method 1(the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user.
Severity ?
8.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rexroth | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:14:19.996Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2107",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "RC7(Build date 20231107)",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-45220",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T16:00:24.608539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T18:11:14.503Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Android Client application, when enrolled with the define method 1(the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:15:02.630Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-45220",
"datePublished": "2023-10-25T14:15:02.630Z",
"dateReserved": "2023-10-18T09:35:22.513Z",
"dateUpdated": "2024-09-11T18:11:14.503Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-43488 (GCVE-0-2023-43488)
Vulnerability from nvd – Published: 2023-10-25 13:27 – Updated: 2024-09-17 14:06
VLAI?
Summary
The vulnerability allows a low privileged (untrusted) application to
modify a critical system property that should be denied, in order to enable the ADB (Android Debug Bridge) protocol to be exposed on the network, exploiting it to gain a privileged shell on the device without requiring the physical access through USB.
Severity ?
7.9 (High)
CWE
- CWE-862 - Missing Authorization
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rexroth | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:44:42.209Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-43488",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T13:32:31.772490Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-17T14:06:24.603Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability allows a low privileged (untrusted) application to\r\nmodify a critical system property that should be denied, in order to enable the ADB (Android Debug Bridge) protocol to be exposed on the network, exploiting it to gain a privileged shell on the device without requiring the physical access through USB."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 7.9,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862 Missing Authorization",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T13:27:09.366Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-43488",
"datePublished": "2023-10-25T13:27:09.366Z",
"dateReserved": "2023-10-18T09:35:22.492Z",
"dateUpdated": "2024-09-17T14:06:24.603Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-41960 (GCVE-0-2023-41960)
Vulnerability from nvd – Published: 2023-10-25 14:12 – Updated: 2024-09-12 14:29
VLAI?
Summary
The vulnerability allows an unprivileged(untrusted) third-party application to interact with a content-provider unsafely exposed by the Android Agent application, potentially modifying sensitive settings of the Android Client application itself.
Severity ?
7.1 (High)
CWE
- CWE-926 - Improper Export of Android Application Components
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rexroth | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:09:49.389Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2107",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2110",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2115",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-41960",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T19:00:56.501041Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-12T14:29:20.687Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability allows an unprivileged(untrusted) third-party application to interact with a content-provider unsafely exposed by the Android Agent application, potentially modifying sensitive settings of the Android Client application itself."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-926",
"description": "CWE-926 Improper Export of Android Application Components",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:12:08.722Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-41960",
"datePublished": "2023-10-25T14:12:08.722Z",
"dateReserved": "2023-10-18T09:35:22.502Z",
"dateUpdated": "2024-09-12T14:29:20.687Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-41372 (GCVE-0-2023-41372)
Vulnerability from nvd – Published: 2023-10-25 14:13 – Updated: 2024-09-12 14:28
VLAI?
Summary
The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair
Severity ?
7.8 (High)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rexroth | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:01:35.280Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2107",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2110",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2115",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-41372",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T18:51:52.995688Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-12T14:28:34.281Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:13:34.827Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-41372",
"datePublished": "2023-10-25T14:13:34.827Z",
"dateReserved": "2023-10-18T09:35:22.507Z",
"dateUpdated": "2024-09-12T14:28:34.281Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-41255 (GCVE-0-2023-41255)
Vulnerability from nvd – Published: 2023-10-25 14:10 – Updated: 2024-09-12 14:30
VLAI?
Summary
The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication
of the ‘su’ binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol exposed on the network.
Severity ?
8.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rexroth | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:54:04.641Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2107",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2110",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2115",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-41255",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T19:04:46.249983Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-12T14:30:27.445Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication \r\nof the \u2018su\u2019 binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol exposed on the network."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:10:50.626Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-41255",
"datePublished": "2023-10-25T14:10:50.626Z",
"dateReserved": "2023-10-18T09:35:22.497Z",
"dateUpdated": "2024-09-12T14:30:27.445Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46102 (GCVE-0-2023-46102)
Vulnerability from cvelistv5 – Published: 2023-10-25 14:19 – Updated: 2024-09-11 13:49
VLAI?
Summary
The Android Client application, when enrolled to the AppHub server, connects to an MQTT
broker to exchange messages and receive commands to execute on the HMI device.
The protocol builds on top of MQTT to implement the remote management of the device is encrypted with a hard-coded DES symmetric key, that can be retrieved reversing both the Android Client application and the server-side web application.
This issue allows an attacker able to control a malicious MQTT broker on the same subnet
network of the device, to craft malicious messages and send them to the HMI device, executing arbitrary commands on the device itself.
Severity ?
8.8 (High)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch Rexroth AG | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.622Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:boschrexrothag:ctrl_hmi_web_panel-wr21_\\(wr2110\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrl_hmi_web_panel-wr21_\\(wr2110\\)",
"vendor": "boschrexrothag",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:boschrexrothag:ctrl_hmi_web_panel-wr21_\\(wr2115\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrl_hmi_web_panel-wr21_\\(wr2115\\)",
"vendor": "boschrexrothag",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:boschrexrothag:ctrl_hmi_web_panel-wr21_\\(wr2107\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrl_hmi_web_panel-wr21_\\(wr2107\\)",
"vendor": "boschrexrothag",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-46102",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T13:45:20.593751Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T13:49:04.787Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Android Client application, when enrolled to the AppHub server, connects to an MQTT\r\nbroker to exchange messages and receive commands to execute on the HMI device.\r\nThe protocol builds on top of MQTT to implement the remote management of the device is encrypted with a hard-coded DES symmetric key, that can be retrieved reversing both the Android Client application and the server-side web application.\r\n\r\n\r\nThis issue allows an attacker able to control a malicious MQTT broker on the same subnet\r\nnetwork of the device, to craft malicious messages and send them to the HMI device, executing arbitrary commands on the device itself."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:19:20.107Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-46102",
"datePublished": "2023-10-25T14:19:20.107Z",
"dateReserved": "2023-10-18T09:35:22.530Z",
"dateUpdated": "2024-09-11T13:49:04.787Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-45851 (GCVE-0-2023-45851)
Vulnerability from cvelistv5 – Published: 2023-10-25 14:18 – Updated: 2024-09-11 18:06
VLAI?
Summary
The Android Client application, when enrolled to the AppHub server,connects to an MQTT broker without enforcing any server authentication.
This issue allows an attacker to force the Android Client application to connect to a malicious MQTT broker, enabling it to send fake messages to the HMI device
Severity ?
8.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch Rexroth AG | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:29:32.293Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2107",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "RC7(Build date 20231107)",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-45851",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T16:00:27.264096Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T18:06:40.524Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Android Client application, when enrolled to the AppHub server,connects to an MQTT broker without enforcing any server authentication.\u00a0\r\n\r\n\r\nThis issue allows an attacker to force the Android Client application to connect to a malicious MQTT broker, enabling it to send fake messages to the HMI device"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:18:08.811Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-45851",
"datePublished": "2023-10-25T14:18:08.811Z",
"dateReserved": "2023-10-18T09:35:22.524Z",
"dateUpdated": "2024-09-11T18:06:40.524Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-45321 (GCVE-0-2023-45321)
Vulnerability from cvelistv5 – Published: 2023-10-25 14:16 – Updated: 2024-09-11 18:11
VLAI?
Summary
The Android Client application, when enrolled with the define method 1 (the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user. Due to the lack of encryption of HTTP,this issue allows an attacker placed in the same subnet network of the HMI device to intercept username and password necessary to authenticate to the MQTT server responsible to implement the remote management protocol.
Severity ?
8.3 (High)
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bosch Rexroth AG | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:21:15.404Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2107",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "RC7(Build date 20231107)",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-45321",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T16:00:25.907168Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T18:11:00.080Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Bosch Rexroth AG",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Android Client application, when enrolled with the define method 1 (the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user. Due to the lack of encryption of HTTP,this issue allows an attacker placed in the same subnet network of the HMI device to intercept username and password necessary to authenticate to the MQTT server responsible to implement the remote management protocol."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:16:41.097Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-45321",
"datePublished": "2023-10-25T14:16:41.097Z",
"dateReserved": "2023-10-18T09:35:22.518Z",
"dateUpdated": "2024-09-11T18:11:00.080Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-45220 (GCVE-0-2023-45220)
Vulnerability from cvelistv5 – Published: 2023-10-25 14:15 – Updated: 2024-09-11 18:11
VLAI?
Summary
The Android Client application, when enrolled with the define method 1(the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user.
Severity ?
8.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rexroth | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:14:19.996Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2107",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "RC7(Build date 20231107)",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-45220",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T16:00:24.608539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T18:11:14.503Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Android Client application, when enrolled with the define method 1(the user manually inserts the server ip address), use HTTP protocol to retrieve sensitive information (ip address and credentials to connect to a remote MQTT broker entity) instead of HTTPS and this feature is not configurable by the user."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:15:02.630Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-45220",
"datePublished": "2023-10-25T14:15:02.630Z",
"dateReserved": "2023-10-18T09:35:22.513Z",
"dateUpdated": "2024-09-11T18:11:14.503Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-41372 (GCVE-0-2023-41372)
Vulnerability from cvelistv5 – Published: 2023-10-25 14:13 – Updated: 2024-09-12 14:28
VLAI?
Summary
The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair
Severity ?
7.8 (High)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rexroth | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:01:35.280Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2107",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2110",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2115",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-41372",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T18:51:52.995688Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-12T14:28:34.281Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:13:34.827Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-41372",
"datePublished": "2023-10-25T14:13:34.827Z",
"dateReserved": "2023-10-18T09:35:22.507Z",
"dateUpdated": "2024-09-12T14:28:34.281Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-41960 (GCVE-0-2023-41960)
Vulnerability from cvelistv5 – Published: 2023-10-25 14:12 – Updated: 2024-09-12 14:29
VLAI?
Summary
The vulnerability allows an unprivileged(untrusted) third-party application to interact with a content-provider unsafely exposed by the Android Agent application, potentially modifying sensitive settings of the Android Client application itself.
Severity ?
7.1 (High)
CWE
- CWE-926 - Improper Export of Android Application Components
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rexroth | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:09:49.389Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2107",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2110",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2115",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-41960",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T19:00:56.501041Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-12T14:29:20.687Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability allows an unprivileged(untrusted) third-party application to interact with a content-provider unsafely exposed by the Android Agent application, potentially modifying sensitive settings of the Android Client application itself."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-926",
"description": "CWE-926 Improper Export of Android Application Components",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:12:08.722Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-41960",
"datePublished": "2023-10-25T14:12:08.722Z",
"dateReserved": "2023-10-18T09:35:22.502Z",
"dateUpdated": "2024-09-12T14:29:20.687Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-41255 (GCVE-0-2023-41255)
Vulnerability from cvelistv5 – Published: 2023-10-25 14:10 – Updated: 2024-09-12 14:30
VLAI?
Summary
The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication
of the ‘su’ binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol exposed on the network.
Severity ?
8.8 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rexroth | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:54:04.641Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2107",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2110",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr2115",
"vendor": "boschrexroth",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-41255",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T19:04:46.249983Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-12T14:30:27.445Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication \r\nof the \u2018su\u2019 binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol exposed on the network."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T14:10:50.626Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-41255",
"datePublished": "2023-10-25T14:10:50.626Z",
"dateReserved": "2023-10-18T09:35:22.497Z",
"dateUpdated": "2024-09-12T14:30:27.445Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-43488 (GCVE-0-2023-43488)
Vulnerability from cvelistv5 – Published: 2023-10-25 13:27 – Updated: 2024-09-17 14:06
VLAI?
Summary
The vulnerability allows a low privileged (untrusted) application to
modify a critical system property that should be denied, in order to enable the ADB (Android Debug Bridge) protocol to be exposed on the network, exploiting it to gain a privileged shell on the device without requiring the physical access through USB.
Severity ?
7.9 (High)
CWE
- CWE-862 - Missing Authorization
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rexroth | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:44:42.209Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-43488",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T13:32:31.772490Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-17T14:06:24.603Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability allows a low privileged (untrusted) application to\r\nmodify a critical system property that should be denied, in order to enable the ADB (Android Debug Bridge) protocol to be exposed on the network, exploiting it to gain a privileged shell on the device without requiring the physical access through USB."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 7.9,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"description": "CWE-862 Missing Authorization",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T13:27:09.366Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-43488",
"datePublished": "2023-10-25T13:27:09.366Z",
"dateReserved": "2023-10-18T09:35:22.492Z",
"dateUpdated": "2024-09-17T14:06:24.603Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-45844 (GCVE-0-2023-45844)
Vulnerability from cvelistv5 – Published: 2023-10-25 13:07 – Updated: 2024-09-10 20:24
VLAI?
Summary
The vulnerability allows a low privileged user that have access to the device when locked in Kiosk mode to install an arbitrary Android application and leverage it to have access to critical device settings such as the device power management or eventually the device secure settings (ADB debug).
Severity ?
7.3 (High)
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rexroth | ctrlX HMI Web Panel - WR21 (WR2107) |
Affected:
all
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:29:32.423Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:rexroth:ctrlx_hmi_web_panel_wr21\\/wr2107\\/:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr21\\/wr2107\\/",
"vendor": "rexroth",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:rexroth:ctrlx_hmi_web_panel_wr21\\/wr2110\\/:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr21\\/wr2110\\/",
"vendor": "rexroth",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:rexroth:ctrlx_hmi_web_panel_wr21\\/wr2115\\/:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ctrlx_hmi_web_panel_wr21\\/wr2115\\/",
"vendor": "rexroth",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-45844",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T20:05:44.966105Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T20:24:25.472Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ctrlX HMI Web Panel - WR21 (WR2107)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2110)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"product": "ctrlX HMI Web Panel - WR21 (WR2115)",
"vendor": "Rexroth",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The vulnerability allows a low privileged user that have access to the device when locked in Kiosk mode to install an arbitrary Android application and leverage it to have access to critical device settings such as the device power management or eventually the device secure settings (ADB debug)."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-25T13:07:15.053Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-45844",
"datePublished": "2023-10-25T13:07:15.053Z",
"dateReserved": "2023-10-18T09:35:22.486Z",
"dateUpdated": "2024-09-10T20:24:25.472Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}