Search

Find a vulnerability

Search criteria

    14 vulnerabilities found for cph2_echarge_firmware by hardy-barth

    CVE-2025-3883 (GCVE-0-2025-3883)

    Vulnerability from nvd – Published: 2025-05-22 00:48 – Updated: 2025-05-22 15:56
    VLAI
    Title
    eCharge Hardy Barth cPH2 index.php Command Injection Remote Code Execution Vulnerability
    Summary
    eCharge Hardy Barth cPH2 index.php Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of eCharge Hardy Barth cPH2 charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of GET parameters provided to the index.php endpoint. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the www-data user. Was ZDI-CAN-23115.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    zdi
    References
    Impacted products
    Date Public
    2025-04-24 00:14
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3883",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-22T15:56:21.206039Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-22T15:56:59.993Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "cPH2",
              "vendor": "eCharge Hardy Barth",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.4"
                }
              ]
            }
          ],
          "dateAssigned": "2025-04-22T21:42:43.699Z",
          "datePublic": "2025-04-24T00:14:08.415Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "eCharge Hardy Barth cPH2 index.php Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of eCharge Hardy Barth cPH2 charging stations. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of GET parameters provided to the index.php endpoint. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the www-data user. Was ZDI-CAN-23115."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-22T00:48:41.901Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-25-249",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-249/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "adhkr - LuwakLab"
          },
          "title": "eCharge Hardy Barth cPH2 index.php Command Injection Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2025-3883",
        "datePublished": "2025-05-22T00:48:41.901Z",
        "dateReserved": "2025-04-22T21:42:43.669Z",
        "dateUpdated": "2025-05-22T15:56:59.993Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3882 (GCVE-0-2025-3882)

    Vulnerability from nvd – Published: 2025-05-22 00:48 – Updated: 2025-05-22 18:37
    VLAI
    Title
    eCharge Hardy Barth cPH2 nwcheckexec.php dest Command Injection Remote Code Execution Vulnerability
    Summary
    eCharge Hardy Barth cPH2 nwcheckexec.php dest Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of eCharge Hardy Barth cPH2 charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of the dest parameter provided to the nwcheckexec.php endpoint. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the www-data user. Was ZDI-CAN-23114.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    zdi
    References
    Impacted products
    Date Public
    2025-04-24 00:14
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3882",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-22T18:37:41.406447Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-22T18:37:53.253Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "cPH2",
              "vendor": "eCharge Hardy Barth",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.4"
                }
              ]
            }
          ],
          "dateAssigned": "2025-04-22T21:42:39.899Z",
          "datePublic": "2025-04-24T00:14:01.701Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "eCharge Hardy Barth cPH2 nwcheckexec.php dest Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of eCharge Hardy Barth cPH2 charging stations. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of the dest parameter provided to the nwcheckexec.php endpoint. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the www-data user. Was ZDI-CAN-23114."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-22T00:48:37.499Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-25-248",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-248/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "adhkr - LuwakLab"
          },
          "title": "eCharge Hardy Barth cPH2 nwcheckexec.php dest Command Injection Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2025-3882",
        "datePublished": "2025-05-22T00:48:37.499Z",
        "dateReserved": "2025-04-22T21:42:39.872Z",
        "dateUpdated": "2025-05-22T18:37:53.253Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3881 (GCVE-0-2025-3881)

    Vulnerability from nvd – Published: 2025-05-22 00:48 – Updated: 2025-05-22 18:38
    VLAI
    Title
    eCharge Hardy Barth cPH2 check_req.php ntp Command Injection Remote Code Execution Vulnerability
    Summary
    eCharge Hardy Barth cPH2 check_req.php ntp Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of eCharge Hardy Barth cPH2 charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of the ntp parameter provided to the check_req.php endpoint. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the www-data user. Was ZDI-CAN-23113.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    zdi
    References
    Impacted products
    Date Public
    2025-04-24 00:13
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3881",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-22T18:38:09.675126Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-22T18:38:54.469Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "cPH2",
              "vendor": "eCharge Hardy Barth",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.4"
                }
              ]
            }
          ],
          "dateAssigned": "2025-04-22T21:42:35.005Z",
          "datePublic": "2025-04-24T00:13:55.688Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "eCharge Hardy Barth cPH2 check_req.php ntp Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of eCharge Hardy Barth cPH2 charging stations. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of the ntp parameter provided to the check_req.php endpoint. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the www-data user. Was ZDI-CAN-23113."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-22T00:48:31.860Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-25-247",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-247/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "adhkr -LuwakLab"
          },
          "title": "eCharge Hardy Barth cPH2 check_req.php ntp Command Injection Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2025-3881",
        "datePublished": "2025-05-22T00:48:31.860Z",
        "dateReserved": "2025-04-22T21:42:34.959Z",
        "dateUpdated": "2025-05-22T18:38:54.469Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-11666 (GCVE-0-2024-11666)

    Vulnerability from nvd – Published: 2024-11-24 22:36 – Updated: 2024-11-25 01:28
    VLAI
    Title
    Unauthenticated Remote Command Injection in eCharge Salia PLCC
    Summary
    Affected devices beacon to eCharge cloud infrastructure asking if there are any command they should run. This communication is established over an insecure channel since peer verification is disabled everywhere. Therefore, remote unauthenticated users  suitably positioned on the network between an EV charger controller and eCharge infrastructure can execute arbitrary commands with elevated privileges on affected devices. This issue affects cph2_echarge_firmware: through 2.0.4.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-345 - Insufficient Verification of Data Authenticity
    Assigner
    References
    Impacted products
    Vendor Product Version
    hardy-barth cph2_echarge_firmware Affected: 0 , ≤ 2.0.4 (semver)
    Create a notification for this product.
    hardy-barth cph2_echarge_firmware Affected: 0 , ≤ 2.0.4 (semver)
        cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-11-24 07:00
    Credits
    Quentin Kaiser from ONEKEY Research Labs
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "cph2_echarge_firmware",
                "vendor": "hardy-barth",
                "versions": [
                  {
                    "lessThanOrEqual": "2.0.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-11666",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-25T01:27:53.302041Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-25T01:28:57.027Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cph2_echarge_firmware",
              "vendor": "hardy-barth",
              "versions": [
                {
                  "lessThanOrEqual": "2.0.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Quentin Kaiser from ONEKEY Research Labs"
            }
          ],
          "datePublic": "2024-11-24T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Affected devices beacon to eCharge cloud infrastructure asking if there are any command they should run. This communication is established over an insecure channel since peer verification is disabled everywhere. Therefore, remote unauthenticated users\u0026nbsp; suitably positioned on the network between an EV charger controller and eCharge infrastructure can execute arbitrary commands with elevated privileges on affected devices.\u003cbr\u003e\u003cbr\u003e\u003cp\u003eThis issue affects cph2_echarge_firmware: through 2.0.4.\u003c/p\u003e"
                }
              ],
              "value": "Affected devices beacon to eCharge cloud infrastructure asking if there are any command they should run. This communication is established over an insecure channel since peer verification is disabled everywhere. Therefore, remote unauthenticated users\u00a0 suitably positioned on the network between an EV charger controller and eCharge infrastructure can execute arbitrary commands with elevated privileges on affected devices.\n\nThis issue affects cph2_echarge_firmware: through 2.0.4."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "CWE-345 Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-24T23:19:03.796Z",
            "orgId": "2d533b80-6e4a-4e20-93e2-171235122846",
            "shortName": "ONEKEY"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthenticated Remote Command Injection in eCharge Salia PLCC",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2d533b80-6e4a-4e20-93e2-171235122846",
        "assignerShortName": "ONEKEY",
        "cveId": "CVE-2024-11666",
        "datePublished": "2024-11-24T22:36:59.989Z",
        "dateReserved": "2024-11-24T22:27:19.421Z",
        "dateUpdated": "2024-11-25T01:28:57.027Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-11665 (GCVE-0-2024-11665)

    Vulnerability from nvd – Published: 2024-11-24 22:32 – Updated: 2024-11-25 01:30
    VLAI
    Title
    Unauthenticated Remote Command Injection
    Summary
    Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.This issue affects cph2_echarge_firmware: through 2.0.4.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    hardy-barth cph2_echarge_firmware Affected: 0 , ≤ 2.0.4 (semver)
    Create a notification for this product.
    hardy-barth cph2_echarge_firmware Affected: 0 , ≤ 2.0.4 (semver)
        cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-11-24 07:00
    Credits
    Quentin Kaiser from ONEKEY Research Labs
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "cph2_echarge_firmware",
                "vendor": "hardy-barth",
                "versions": [
                  {
                    "lessThanOrEqual": "2.0.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-11665",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-25T01:30:19.320887Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-25T01:30:24.409Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cph2_echarge_firmware",
              "vendor": "hardy-barth",
              "versions": [
                {
                  "lessThanOrEqual": "2.0.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Quentin Kaiser from ONEKEY Research Labs"
            }
          ],
          "datePublic": "2024-11-24T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.\u003cp\u003eThis issue affects cph2_echarge_firmware: through 2.0.4.\u003c/p\u003e"
                }
              ],
              "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.This issue affects cph2_echarge_firmware: through 2.0.4."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-24T23:18:51.581Z",
            "orgId": "2d533b80-6e4a-4e20-93e2-171235122846",
            "shortName": "ONEKEY"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthenticated Remote Command Injection",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2d533b80-6e4a-4e20-93e2-171235122846",
        "assignerShortName": "ONEKEY",
        "cveId": "CVE-2024-11665",
        "datePublished": "2024-11-24T22:32:43.427Z",
        "dateReserved": "2024-11-24T22:27:15.904Z",
        "dateUpdated": "2024-11-25T01:30:24.409Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46360 (GCVE-0-2023-46360)

    Vulnerability from nvd – Published: 2024-02-06 00:00 – Updated: 2024-08-02 20:45
    VLAI
    Summary
    Hardy Barth cPH2 eCharge Ladestation v1.87.0 and earlier is vulnerable to Execution with Unnecessary Privileges.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-250 - Execution with Unnecessary Privileges
    Assigner
    Impacted products
    Vendor Product Version
    hardy-barth cph2_echarge_firmware Affected: 0 , ≤ v1.87.0 (custom)
        cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    hardy-barth cph2_echarge Affected: 0 , < v1.87.0 (custom)
        cpe:2.3:h:hardy-barth:cph2_echarge:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cph2_echarge_firmware",
                "vendor": "hardy-barth",
                "versions": [
                  {
                    "lessThanOrEqual": "v1.87.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:hardy-barth:cph2_echarge:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cph2_echarge",
                "vendor": "hardy-barth",
                "versions": [
                  {
                    "lessThan": "v1.87.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46360",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-28T17:53:47.854268Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-250",
                    "description": "CWE-250 Execution with Unnecessary Privileges",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-28T17:58:46.351Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:45:41.295Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://hardy.com"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.offensity.com/en/blog/os-command-injection-in-cph2-charging-station-200-cve-2023-46359-and-cve-2023-46360/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Hardy Barth cPH2 eCharge Ladestation v1.87.0 and earlier is vulnerable to Execution with Unnecessary Privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-02-06T00:46:53.682Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "http://hardy.com"
            },
            {
              "url": "https://www.offensity.com/en/blog/os-command-injection-in-cph2-charging-station-200-cve-2023-46359-and-cve-2023-46360/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-46360",
        "datePublished": "2024-02-06T00:00:00.000Z",
        "dateReserved": "2023-10-23T00:00:00.000Z",
        "dateUpdated": "2024-08-02T20:45:41.295Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46359 (GCVE-0-2023-46359)

    Vulnerability from nvd – Published: 2024-02-06 00:00 – Updated: 2024-10-28 02:00
    VLAI
    Summary
    An OS command injection vulnerability in Hardy Barth cPH2 eCharge Ladestation v1.87.0 and earlier, may allow an unauthenticated remote attacker to execute arbitrary commands on the system via a specifically crafted arguments passed to the connectivity check feature.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46359",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-02-06T14:10:52.995119Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-28T02:00:51.622Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:45:41.233Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://hardy.com"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.offensity.com/en/blog/os-command-injection-in-cph2-charging-station-200-cve-2023-46359-and-cve-2023-46360/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An OS command injection vulnerability in Hardy Barth cPH2 eCharge Ladestation v1.87.0 and earlier, may allow an unauthenticated remote attacker to execute arbitrary commands on the system via a specifically crafted arguments passed to the connectivity check feature."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-02-06T00:46:45.328Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "http://hardy.com"
            },
            {
              "url": "https://www.offensity.com/en/blog/os-command-injection-in-cph2-charging-station-200-cve-2023-46359-and-cve-2023-46360/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-46359",
        "datePublished": "2024-02-06T00:00:00.000Z",
        "dateReserved": "2023-10-23T00:00:00.000Z",
        "dateUpdated": "2024-10-28T02:00:51.622Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3883 (GCVE-0-2025-3883)

    Vulnerability from cvelistv5 – Published: 2025-05-22 00:48 – Updated: 2025-05-22 15:56
    VLAI
    Title
    eCharge Hardy Barth cPH2 index.php Command Injection Remote Code Execution Vulnerability
    Summary
    eCharge Hardy Barth cPH2 index.php Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of eCharge Hardy Barth cPH2 charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of GET parameters provided to the index.php endpoint. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the www-data user. Was ZDI-CAN-23115.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    zdi
    References
    Impacted products
    Date Public
    2025-04-24 00:14
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3883",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-22T15:56:21.206039Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-22T15:56:59.993Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "cPH2",
              "vendor": "eCharge Hardy Barth",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.4"
                }
              ]
            }
          ],
          "dateAssigned": "2025-04-22T21:42:43.699Z",
          "datePublic": "2025-04-24T00:14:08.415Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "eCharge Hardy Barth cPH2 index.php Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of eCharge Hardy Barth cPH2 charging stations. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of GET parameters provided to the index.php endpoint. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the www-data user. Was ZDI-CAN-23115."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-22T00:48:41.901Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-25-249",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-249/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "adhkr - LuwakLab"
          },
          "title": "eCharge Hardy Barth cPH2 index.php Command Injection Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2025-3883",
        "datePublished": "2025-05-22T00:48:41.901Z",
        "dateReserved": "2025-04-22T21:42:43.669Z",
        "dateUpdated": "2025-05-22T15:56:59.993Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3882 (GCVE-0-2025-3882)

    Vulnerability from cvelistv5 – Published: 2025-05-22 00:48 – Updated: 2025-05-22 18:37
    VLAI
    Title
    eCharge Hardy Barth cPH2 nwcheckexec.php dest Command Injection Remote Code Execution Vulnerability
    Summary
    eCharge Hardy Barth cPH2 nwcheckexec.php dest Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of eCharge Hardy Barth cPH2 charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of the dest parameter provided to the nwcheckexec.php endpoint. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the www-data user. Was ZDI-CAN-23114.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    zdi
    References
    Impacted products
    Date Public
    2025-04-24 00:14
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3882",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-22T18:37:41.406447Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-22T18:37:53.253Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "cPH2",
              "vendor": "eCharge Hardy Barth",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.4"
                }
              ]
            }
          ],
          "dateAssigned": "2025-04-22T21:42:39.899Z",
          "datePublic": "2025-04-24T00:14:01.701Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "eCharge Hardy Barth cPH2 nwcheckexec.php dest Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of eCharge Hardy Barth cPH2 charging stations. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of the dest parameter provided to the nwcheckexec.php endpoint. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the www-data user. Was ZDI-CAN-23114."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-22T00:48:37.499Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-25-248",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-248/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "adhkr - LuwakLab"
          },
          "title": "eCharge Hardy Barth cPH2 nwcheckexec.php dest Command Injection Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2025-3882",
        "datePublished": "2025-05-22T00:48:37.499Z",
        "dateReserved": "2025-04-22T21:42:39.872Z",
        "dateUpdated": "2025-05-22T18:37:53.253Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3881 (GCVE-0-2025-3881)

    Vulnerability from cvelistv5 – Published: 2025-05-22 00:48 – Updated: 2025-05-22 18:38
    VLAI
    Title
    eCharge Hardy Barth cPH2 check_req.php ntp Command Injection Remote Code Execution Vulnerability
    Summary
    eCharge Hardy Barth cPH2 check_req.php ntp Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of eCharge Hardy Barth cPH2 charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of the ntp parameter provided to the check_req.php endpoint. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the www-data user. Was ZDI-CAN-23113.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    zdi
    References
    Impacted products
    Date Public
    2025-04-24 00:13
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3881",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-22T18:38:09.675126Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-22T18:38:54.469Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "cPH2",
              "vendor": "eCharge Hardy Barth",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0.4"
                }
              ]
            }
          ],
          "dateAssigned": "2025-04-22T21:42:35.005Z",
          "datePublic": "2025-04-24T00:13:55.688Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "eCharge Hardy Barth cPH2 check_req.php ntp Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of eCharge Hardy Barth cPH2 charging stations. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of the ntp parameter provided to the check_req.php endpoint. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the www-data user. Was ZDI-CAN-23113."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-22T00:48:31.860Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "name": "ZDI-25-247",
              "tags": [
                "x_research-advisory"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-25-247/"
            }
          ],
          "source": {
            "lang": "en",
            "value": "adhkr -LuwakLab"
          },
          "title": "eCharge Hardy Barth cPH2 check_req.php ntp Command Injection Remote Code Execution Vulnerability"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2025-3881",
        "datePublished": "2025-05-22T00:48:31.860Z",
        "dateReserved": "2025-04-22T21:42:34.959Z",
        "dateUpdated": "2025-05-22T18:38:54.469Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-11666 (GCVE-0-2024-11666)

    Vulnerability from cvelistv5 – Published: 2024-11-24 22:36 – Updated: 2024-11-25 01:28
    VLAI
    Title
    Unauthenticated Remote Command Injection in eCharge Salia PLCC
    Summary
    Affected devices beacon to eCharge cloud infrastructure asking if there are any command they should run. This communication is established over an insecure channel since peer verification is disabled everywhere. Therefore, remote unauthenticated users  suitably positioned on the network between an EV charger controller and eCharge infrastructure can execute arbitrary commands with elevated privileges on affected devices. This issue affects cph2_echarge_firmware: through 2.0.4.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-345 - Insufficient Verification of Data Authenticity
    Assigner
    References
    Impacted products
    Vendor Product Version
    hardy-barth cph2_echarge_firmware Affected: 0 , ≤ 2.0.4 (semver)
    Create a notification for this product.
    hardy-barth cph2_echarge_firmware Affected: 0 , ≤ 2.0.4 (semver)
        cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-11-24 07:00
    Credits
    Quentin Kaiser from ONEKEY Research Labs
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "cph2_echarge_firmware",
                "vendor": "hardy-barth",
                "versions": [
                  {
                    "lessThanOrEqual": "2.0.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-11666",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-25T01:27:53.302041Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-25T01:28:57.027Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cph2_echarge_firmware",
              "vendor": "hardy-barth",
              "versions": [
                {
                  "lessThanOrEqual": "2.0.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Quentin Kaiser from ONEKEY Research Labs"
            }
          ],
          "datePublic": "2024-11-24T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Affected devices beacon to eCharge cloud infrastructure asking if there are any command they should run. This communication is established over an insecure channel since peer verification is disabled everywhere. Therefore, remote unauthenticated users\u0026nbsp; suitably positioned on the network between an EV charger controller and eCharge infrastructure can execute arbitrary commands with elevated privileges on affected devices.\u003cbr\u003e\u003cbr\u003e\u003cp\u003eThis issue affects cph2_echarge_firmware: through 2.0.4.\u003c/p\u003e"
                }
              ],
              "value": "Affected devices beacon to eCharge cloud infrastructure asking if there are any command they should run. This communication is established over an insecure channel since peer verification is disabled everywhere. Therefore, remote unauthenticated users\u00a0 suitably positioned on the network between an EV charger controller and eCharge infrastructure can execute arbitrary commands with elevated privileges on affected devices.\n\nThis issue affects cph2_echarge_firmware: through 2.0.4."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "CWE-345 Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-24T23:19:03.796Z",
            "orgId": "2d533b80-6e4a-4e20-93e2-171235122846",
            "shortName": "ONEKEY"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthenticated Remote Command Injection in eCharge Salia PLCC",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2d533b80-6e4a-4e20-93e2-171235122846",
        "assignerShortName": "ONEKEY",
        "cveId": "CVE-2024-11666",
        "datePublished": "2024-11-24T22:36:59.989Z",
        "dateReserved": "2024-11-24T22:27:19.421Z",
        "dateUpdated": "2024-11-25T01:28:57.027Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-11665 (GCVE-0-2024-11665)

    Vulnerability from cvelistv5 – Published: 2024-11-24 22:32 – Updated: 2024-11-25 01:30
    VLAI
    Title
    Unauthenticated Remote Command Injection
    Summary
    Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.This issue affects cph2_echarge_firmware: through 2.0.4.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    hardy-barth cph2_echarge_firmware Affected: 0 , ≤ 2.0.4 (semver)
    Create a notification for this product.
    hardy-barth cph2_echarge_firmware Affected: 0 , ≤ 2.0.4 (semver)
        cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-11-24 07:00
    Credits
    Quentin Kaiser from ONEKEY Research Labs
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "cph2_echarge_firmware",
                "vendor": "hardy-barth",
                "versions": [
                  {
                    "lessThanOrEqual": "2.0.4",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-11665",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-25T01:30:19.320887Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-25T01:30:24.409Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "cph2_echarge_firmware",
              "vendor": "hardy-barth",
              "versions": [
                {
                  "lessThanOrEqual": "2.0.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Quentin Kaiser from ONEKEY Research Labs"
            }
          ],
          "datePublic": "2024-11-24T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.\u003cp\u003eThis issue affects cph2_echarge_firmware: through 2.0.4.\u003c/p\u003e"
                }
              ],
              "value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.This issue affects cph2_echarge_firmware: through 2.0.4."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-24T23:18:51.581Z",
            "orgId": "2d533b80-6e4a-4e20-93e2-171235122846",
            "shortName": "ONEKEY"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.onekey.com/resource/critical-vulnerabilities-in-ev-charging-stations-analysis-of-echarge-controllers"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Unauthenticated Remote Command Injection",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2d533b80-6e4a-4e20-93e2-171235122846",
        "assignerShortName": "ONEKEY",
        "cveId": "CVE-2024-11665",
        "datePublished": "2024-11-24T22:32:43.427Z",
        "dateReserved": "2024-11-24T22:27:15.904Z",
        "dateUpdated": "2024-11-25T01:30:24.409Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46359 (GCVE-0-2023-46359)

    Vulnerability from cvelistv5 – Published: 2024-02-06 00:00 – Updated: 2024-10-28 02:00
    VLAI
    Summary
    An OS command injection vulnerability in Hardy Barth cPH2 eCharge Ladestation v1.87.0 and earlier, may allow an unauthenticated remote attacker to execute arbitrary commands on the system via a specifically crafted arguments passed to the connectivity check feature.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46359",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-02-06T14:10:52.995119Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-28T02:00:51.622Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:45:41.233Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://hardy.com"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.offensity.com/en/blog/os-command-injection-in-cph2-charging-station-200-cve-2023-46359-and-cve-2023-46360/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An OS command injection vulnerability in Hardy Barth cPH2 eCharge Ladestation v1.87.0 and earlier, may allow an unauthenticated remote attacker to execute arbitrary commands on the system via a specifically crafted arguments passed to the connectivity check feature."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-02-06T00:46:45.328Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "http://hardy.com"
            },
            {
              "url": "https://www.offensity.com/en/blog/os-command-injection-in-cph2-charging-station-200-cve-2023-46359-and-cve-2023-46360/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-46359",
        "datePublished": "2024-02-06T00:00:00.000Z",
        "dateReserved": "2023-10-23T00:00:00.000Z",
        "dateUpdated": "2024-10-28T02:00:51.622Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46360 (GCVE-0-2023-46360)

    Vulnerability from cvelistv5 – Published: 2024-02-06 00:00 – Updated: 2024-08-02 20:45
    VLAI
    Summary
    Hardy Barth cPH2 eCharge Ladestation v1.87.0 and earlier is vulnerable to Execution with Unnecessary Privileges.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-250 - Execution with Unnecessary Privileges
    Assigner
    Impacted products
    Vendor Product Version
    hardy-barth cph2_echarge_firmware Affected: 0 , ≤ v1.87.0 (custom)
        cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    hardy-barth cph2_echarge Affected: 0 , < v1.87.0 (custom)
        cpe:2.3:h:hardy-barth:cph2_echarge:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:hardy-barth:cph2_echarge_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cph2_echarge_firmware",
                "vendor": "hardy-barth",
                "versions": [
                  {
                    "lessThanOrEqual": "v1.87.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:hardy-barth:cph2_echarge:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "cph2_echarge",
                "vendor": "hardy-barth",
                "versions": [
                  {
                    "lessThan": "v1.87.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-46360",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-28T17:53:47.854268Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-250",
                    "description": "CWE-250 Execution with Unnecessary Privileges",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-28T17:58:46.351Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:45:41.295Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://hardy.com"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.offensity.com/en/blog/os-command-injection-in-cph2-charging-station-200-cve-2023-46359-and-cve-2023-46360/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Hardy Barth cPH2 eCharge Ladestation v1.87.0 and earlier is vulnerable to Execution with Unnecessary Privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-02-06T00:46:53.682Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "http://hardy.com"
            },
            {
              "url": "https://www.offensity.com/en/blog/os-command-injection-in-cph2-charging-station-200-cve-2023-46359-and-cve-2023-46360/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-46360",
        "datePublished": "2024-02-06T00:00:00.000Z",
        "dateReserved": "2023-10-23T00:00:00.000Z",
        "dateUpdated": "2024-08-02T20:45:41.295Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }