Search

Find a vulnerability

Search criteria

    31 vulnerabilities found for camera by vivotek

    VAR-202402-3037

    Vulnerability from variot - Updated: 2025-05-17 23:24

    An issue in vivotek Network Camera v.FD8166A-VVTK-0204j allows a remote attacker to execute arbitrary code via a crafted payload to the upload_file.cgi component. VIVOTEK Inc. of FD8166A-VVTK-0204j There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202402-3037",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "vivotek",
            "version": "v.fd8166a-vvtk-0204j"
          },
          {
            "model": "fd8166a-vvtk-0204j",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "vivotek",
            "version": "fd8166a-vvtk-0204j  firmware  v.fd8166a-vvtk-0204j"
          },
          {
            "model": "fd8166a-vvtk-0204j",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "fd8166a-vvtk-0204j",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-023848"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-26548"
          }
        ]
      },
      "cve": "CVE-2024-26548",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2024-26548",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2024-023848",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                "id": "CVE-2024-26548",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "OTHER",
                "id": "JVNDB-2024-023848",
                "trust": 0.8,
                "value": "Critical"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-023848"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-26548"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An issue in vivotek Network Camera v.FD8166A-VVTK-0204j allows a remote attacker to execute arbitrary code via a crafted payload to the upload_file.cgi component. VIVOTEK Inc. of FD8166A-VVTK-0204j There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2024-26548"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-023848"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2024-26548",
            "trust": 2.6
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-023848",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-023848"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-26548"
          }
        ]
      },
      "id": "VAR-202402-3037",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.8783784
      },
      "last_update_date": "2025-05-17T23:24:52.152000Z",
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-023848"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-26548"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.0,
            "url": "https://github.com/cwh031600/vivotek/blob/main/vivotek-fd8166a-uploadfile-dos/vivotek-fd8166a-uploadfile-analysis.md"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2024-26548"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-023848"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-26548"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-023848"
          },
          {
            "db": "NVD",
            "id": "CVE-2024-26548"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-023848"
          },
          {
            "date": "2024-02-29T20:15:41.457000",
            "db": "NVD",
            "id": "CVE-2024-26548"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2025-05-15T08:54:00",
            "db": "JVNDB",
            "id": "JVNDB-2024-023848"
          },
          {
            "date": "2025-05-13T14:34:21.830000",
            "db": "NVD",
            "id": "CVE-2024-26548"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK\u00a0Inc.\u00a0 of \u00a0FD8166A-VVTK-0204j\u00a0 Firmware vulnerabilities",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2024-023848"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-201909-1017

    Vulnerability from variot - Updated: 2025-01-30 21:46

    VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header. VIVOTEK IP Camera The device firmware contains a classic buffer overflow vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201909-1017",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "camera",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "vivotek",
            "version": "0x20x"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/h:vivotek:camera",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          }
        ]
      },
      "cve": "CVE-2019-14457",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2019-14457",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-146405",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2019-14457",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-14457",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2019-14457",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2019-14457",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201909-456",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-146405",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header. VIVOTEK IP Camera The device firmware contains a classic buffer overflow vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-14457",
            "trust": 2.6
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456",
            "trust": 0.7
          },
          {
            "db": "OTHER",
            "id": "NONE",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-146405",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          }
        ]
      },
      "id": "VAR-201909-1017",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          }
        ],
        "trust": 1.0783784
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "camera device"
            ],
            "sub_category": "camera",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          }
        ]
      },
      "last_update_date": "2025-01-30T21:46:50.793000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "VVTK\u2212SA-2019-002",
            "trust": 0.8,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
          },
          {
            "title": "VIVOTEK IP Camera Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=98049"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-120",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-14457"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-14457"
          },
          {
            "trust": 0.1,
            "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14457"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-09-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "date": "2019-09-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "date": "2019-09-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          },
          {
            "date": "2019-09-10T18:15:12.900000",
            "db": "NVD",
            "id": "CVE-2019-14457"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-09-16T00:00:00",
            "db": "VULHUB",
            "id": "VHN-146405"
          },
          {
            "date": "2019-09-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          },
          {
            "date": "2021-07-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          },
          {
            "date": "2024-11-21T04:26:46.890000",
            "db": "NVD",
            "id": "CVE-2019-14457"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK IP Camera Classic buffer overflow vulnerability in device firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009359"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-456"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201901-0608

    Vulnerability from variot - Updated: 2025-01-30 21:37

    Cross-site scripting in syslog.html in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript code via an HTTP Referer Header. VIVOTEKNetworkCameraSeries is a series of network camera products from China VIVOTEK

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201901-0608",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "camera",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "vivotek",
            "version": "0x06x to  0x08x"
          },
          {
            "model": "network cameras",
            "scope": "gte",
            "trust": 0.6,
            "vendor": "vivotek",
            "version": "0x06x,\u003c=0x08x"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-00363"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013359"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-066"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18244"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/h:vivotek:camera",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013359"
          }
        ]
      },
      "cve": "CVE-2018-18244",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.6,
                "id": "CVE-2018-18244",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-00363",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.6,
                "id": "VHN-128784",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.8,
                "id": "CVE-2018-18244",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.8,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-18244",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-18244",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-00363",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201901-066",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-128784",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-00363"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128784"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013359"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-066"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18244"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Cross-site scripting in syslog.html in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript code via an HTTP Referer Header. VIVOTEKNetworkCameraSeries is a series of network camera products from China VIVOTEK",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-18244"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013359"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00363"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128784"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-18244",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013359",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-066",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00363",
            "trust": 0.6
          },
          {
            "db": "OTHER",
            "id": "NONE",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-128784",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00363"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128784"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013359"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-066"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18244"
          }
        ]
      },
      "id": "VAR-201901-0608",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00363"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128784"
          }
        ],
        "trust": 1.7391892
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          },
          {
            "category": [
              "camera device"
            ],
            "sub_category": "camera",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00363"
          }
        ]
      },
      "last_update_date": "2025-01-30T21:37:12.826000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "VVTK-SA-2018-006",
            "trust": 0.8,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
          },
          {
            "title": "Patch for cross-site scripting vulnerability in VIVOTEKNetworkCamera series",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/149247"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-00363"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013359"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-128784"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013359"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18244"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.3,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
          },
          {
            "trust": 2.3,
            "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18244"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18244"
          },
          {
            "trust": 0.1,
            "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00363"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128784"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013359"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-066"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18244"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00363"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128784"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013359"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-066"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18244"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-01-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-00363"
          },
          {
            "date": "2019-01-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-128784"
          },
          {
            "date": "2019-02-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-013359"
          },
          {
            "date": "2019-01-04T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201901-066"
          },
          {
            "date": "2019-01-03T20:29:00.373000",
            "db": "NVD",
            "id": "CVE-2018-18244"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-01-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-00363"
          },
          {
            "date": "2019-01-14T00:00:00",
            "db": "VULHUB",
            "id": "VHN-128784"
          },
          {
            "date": "2019-02-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-013359"
          },
          {
            "date": "2019-01-04T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201901-066"
          },
          {
            "date": "2024-11-21T03:55:34.567000",
            "db": "NVD",
            "id": "CVE-2018-18244"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-066"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK Network Camera Product firmware Vulnerable to cross-site scripting",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013359"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-066"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201901-0605

    Vulnerability from variot - Updated: 2025-01-30 21:09

    Cross-site scripting in event_script.js in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript via a URL query string parameter. VIVOTEKNetworkCameraSeries is a series of network camera products from China VIVOTEK. A cross-site scripting vulnerability exists in the event_script.js file in the VIVOTEKNetworkCamera family of products from 0x06x to 0x08x

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201901-0605",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "camera",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "vivotek",
            "version": "0x06x to  0x08x"
          },
          {
            "model": "network camera series",
            "scope": "gte",
            "trust": 0.6,
            "vendor": "vivotek",
            "version": "0x06x;\u003c=0x08x"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-00683"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013358"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-065"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18005"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/h:vivotek:camera",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013358"
          }
        ]
      },
      "cve": "CVE-2018-18005",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.6,
                "id": "CVE-2018-18005",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2019-00683",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.6,
                "id": "VHN-128521",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 2.8,
                "id": "CVE-2018-18005",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.8,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-18005",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-18005",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-00683",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201901-065",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-128521",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-00683"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128521"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013358"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-065"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18005"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Cross-site scripting in event_script.js in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript via a URL query string parameter. VIVOTEKNetworkCameraSeries is a series of network camera products from China VIVOTEK. A cross-site scripting vulnerability exists in the event_script.js file in the VIVOTEKNetworkCamera family of products from 0x06x to 0x08x",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-18005"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013358"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00683"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128521"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-18005",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013358",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-065",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00683",
            "trust": 0.6
          },
          {
            "db": "OTHER",
            "id": "NONE",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-128521",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00683"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128521"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013358"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-065"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18005"
          }
        ]
      },
      "id": "VAR-201901-0605",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00683"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128521"
          }
        ],
        "trust": 1.5516892
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          },
          {
            "category": [
              "camera device"
            ],
            "sub_category": "camera",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00683"
          }
        ]
      },
      "last_update_date": "2025-01-30T21:09:41.617000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "VVTK-SA-2018-006",
            "trust": 0.8,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
          },
          {
            "title": "Patch for VIVOTEKNetworkCamera Series Cross-Site Scripting Vulnerability (CNVD-2019-00683)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/149453"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-00683"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013358"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-128521"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013358"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18005"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.3,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18005"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18005"
          },
          {
            "trust": 0.1,
            "url": "https://ieeexplore.ieee.org/abstract/document/10769424"
          }
        ],
        "sources": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00683"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128521"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013358"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-065"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18005"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "OTHER",
            "id": null
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-00683"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128521"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013358"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-065"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18005"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-01-09T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-00683"
          },
          {
            "date": "2019-01-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-128521"
          },
          {
            "date": "2019-02-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-013358"
          },
          {
            "date": "2019-01-04T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201901-065"
          },
          {
            "date": "2019-01-03T20:29:00.327000",
            "db": "NVD",
            "id": "CVE-2018-18005"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-01-09T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-00683"
          },
          {
            "date": "2019-01-14T00:00:00",
            "db": "VULHUB",
            "id": "VHN-128521"
          },
          {
            "date": "2019-02-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-013358"
          },
          {
            "date": "2019-01-04T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201901-065"
          },
          {
            "date": "2024-11-21T03:55:21.337000",
            "db": "NVD",
            "id": "CVE-2018-18005"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-065"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK Network Camera Product firmware Vulnerable to cross-site scripting",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013358"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-065"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201809-0170

    Vulnerability from variot - Updated: 2024-11-23 23:12

    VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi. VIVOTEK FD8177 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VIVOTEKFD8177 is a network camera product from Vivotek. A command injection vulnerability exists in versions prior to VIVOTEKFD8177XXXXXX-VVTK-xx06a

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0170",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "camera",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "fd8177 \u003cxxxxxx-vvtk-xx06a",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/h:vivotek:camera",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          }
        ]
      },
      "cve": "CVE-2018-14771",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2018-14771",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2019-06202",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "VHN-124964",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2018-14771",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-14771",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-14771",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-06202",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201809-207",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124964",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2018-14771",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14771"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi. VIVOTEK FD8177 The device contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VIVOTEKFD8177 is a network camera product from Vivotek. A command injection vulnerability exists in versions prior to VIVOTEKFD8177XXXXXX-VVTK-xx06a",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14771"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14771",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14771",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14771"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "id": "VAR-201809-0170",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          }
        ],
        "trust": 1.6391892
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          }
        ]
      },
      "last_update_date": "2024-11-23T23:12:03.584000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "VVTK-SA-2018-003",
            "trust": 0.8,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
          },
          {
            "title": "Cybersecurity",
            "trust": 0.8,
            "url": "https://www.vivotek.com/website/support/cybersecurity/"
          },
          {
            "title": "VIVOTEKFD8177 command to inject vulnerability patch",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/155263"
          },
          {
            "title": "VIVOTEK FD8177 Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84543"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-77",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
          },
          {
            "trust": 1.8,
            "url": "https://www.vivotek.com/website/support/cybersecurity/"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14771"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14771"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14771"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-14771"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-03-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "date": "2018-09-05T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "date": "2018-09-05T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-14771"
          },
          {
            "date": "2018-12-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "date": "2018-09-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "date": "2018-09-05T21:29:00.907000",
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-03-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124964"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-14771"
          },
          {
            "date": "2018-12-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-010299"
          },
          {
            "date": "2020-10-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          },
          {
            "date": "2024-11-21T03:49:45.227000",
            "db": "NVD",
            "id": "CVE-2018-14771"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK FD8177 Command Injection Vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06202"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          }
        ],
        "trust": 1.2
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-207"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201809-0169

    Vulnerability from variot - Updated: 2024-11-23 23:02

    VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/device_service). VIVOTEK FD8177 The device contains a command injection vulnerability.Information is acquired, information is falsified, and denial of service (DoS) May be in a state. VIVOTEKFD8177 is a network camera product from Vivotek. There is a security vulnerability in VIVOTEK FD8177 prior to XXXXXX-VVTK-xx06a

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0169",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "camera",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "fd8177 \u003cxxxxxx-vvtk-xx06a",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06203"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010298"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-208"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14770"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/h:vivotek:camera",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010298"
          }
        ]
      },
      "cve": "CVE-2018-14770",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2018-14770",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2019-06203",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "VHN-124963",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2018-14770",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-14770",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-14770",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-06203",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201809-208",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124963",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06203"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124963"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010298"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-208"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14770"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/device_service). VIVOTEK FD8177 The device contains a command injection vulnerability.Information is acquired, information is falsified, and denial of service (DoS) May be in a state. VIVOTEKFD8177 is a network camera product from Vivotek. There is a security vulnerability in VIVOTEK FD8177 prior to XXXXXX-VVTK-xx06a",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14770"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010298"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-06203"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124963"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14770",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010298",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-208",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-06203",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-124963",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06203"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124963"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010298"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-208"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14770"
          }
        ]
      },
      "id": "VAR-201809-0169",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06203"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124963"
          }
        ],
        "trust": 1.6391892
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06203"
          }
        ]
      },
      "last_update_date": "2024-11-23T23:02:01.531000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "VVTK-SA-2018-003",
            "trust": 0.8,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
          },
          {
            "title": "Cybersecurity",
            "trust": 0.8,
            "url": "https://www.vivotek.com/website/support/cybersecurity/"
          },
          {
            "title": "Patch for VIVOTEKFD8177 Command Injection Vulnerability (CNVD-2019-06203)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/155265"
          },
          {
            "title": "VIVOTEK FD8177 Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84544"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06203"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010298"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-208"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-77",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124963"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010298"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14770"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.3,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://www.vivotek.com/website/support/cybersecurity/"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14770"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14770"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06203"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124963"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010298"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-208"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14770"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06203"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124963"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010298"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-208"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14770"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-03-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-06203"
          },
          {
            "date": "2018-09-05T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124963"
          },
          {
            "date": "2018-12-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-010298"
          },
          {
            "date": "2018-09-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201809-208"
          },
          {
            "date": "2018-09-05T21:29:00.780000",
            "db": "NVD",
            "id": "CVE-2018-14770"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-03-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-06203"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124963"
          },
          {
            "date": "2018-12-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-010298"
          },
          {
            "date": "2020-10-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201809-208"
          },
          {
            "date": "2024-11-21T03:49:45.070000",
            "db": "NVD",
            "id": "CVE-2018-14770"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-208"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK FD8177 Command injection vulnerabilities in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010298"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-208"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201901-0604

    Vulnerability from variot - Updated: 2024-11-23 22:48

    Incorrect Access Control in mod_inetd.cgi in VIVOTEK Network Camera Series products with firmware before XXXXXX-VVTK-0X09a allows remote attackers to enable arbitrary system services via a URL parameter. VIVOTEK Network Camera Series is a series of network camera products of VIVOTEK Corporation in China

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201901-0604",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "camera",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "vivotek",
            "version": "xxxxxx-vvtk-0x09a"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013357"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-064"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18004"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/h:vivotek:camera",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013357"
          }
        ]
      },
      "cve": "CVE-2018-18004",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2018-18004",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "VHN-128520",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2018-18004",
                "impactScore": 1.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-18004",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-18004",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201901-064",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-128520",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-128520"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013357"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-064"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18004"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Incorrect Access Control in mod_inetd.cgi in VIVOTEK Network Camera Series products with firmware before XXXXXX-VVTK-0X09a allows remote attackers to enable arbitrary system services via a URL parameter. VIVOTEK Network Camera Series is a series of network camera products of VIVOTEK Corporation in China",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-18004"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013357"
          },
          {
            "db": "VULHUB",
            "id": "VHN-128520"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-18004",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013357",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-064",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-128520",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-128520"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013357"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-064"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18004"
          }
        ]
      },
      "id": "VAR-201901-0604",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-128520"
          }
        ],
        "trust": 0.9783784
      },
      "last_update_date": "2024-11-23T22:48:30.767000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "VVTK-SA-2018-006",
            "trust": 0.8,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
          },
          {
            "title": "VIVOTEK Network Camera Repairs for Series Product Access Control Error Vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=100320"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013357"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-064"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-862",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-284",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-425",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-128520"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013357"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18004"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18004"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-18004"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-128520"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013357"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-064"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18004"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-128520"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013357"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-064"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-18004"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-01-03T00:00:00",
            "db": "VULHUB",
            "id": "VHN-128520"
          },
          {
            "date": "2019-02-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-013357"
          },
          {
            "date": "2019-01-04T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201901-064"
          },
          {
            "date": "2019-01-03T20:29:00.267000",
            "db": "NVD",
            "id": "CVE-2018-18004"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-128520"
          },
          {
            "date": "2019-02-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-013357"
          },
          {
            "date": "2020-08-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201901-064"
          },
          {
            "date": "2024-11-21T03:55:21.190000",
            "db": "NVD",
            "id": "CVE-2018-18004"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-064"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK Network Camera Product firmware Access control vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-013357"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "access control error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201901-064"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201909-1474

    Vulnerability from variot - Updated: 2024-11-23 22:44

    An authentication bypass vulnerability in VIVOTEK IPCam versions prior to 0x13a was found. VIVOTEK IPCam Contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Vivotek VIVOTEK IPCam is a network camera produced by Taiwan Vivotek Corporation. This vulnerability stems from the lack of authentication measures or insufficient authentication strength in network systems or products

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201909-1474",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "camera",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "vivotek",
            "version": "0x13a"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009357"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10256"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/h:vivotek:camera",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009357"
          }
        ]
      },
      "cve": "CVE-2019-10256",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2019-10256",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-141784",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2019-10256",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-10256",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2019-10256",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2019-10256",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201909-458",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-141784",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-141784"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009357"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-458"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10256"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An authentication bypass vulnerability in VIVOTEK IPCam versions prior to 0x13a was found. VIVOTEK IPCam Contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Vivotek VIVOTEK IPCam is a network camera produced by Taiwan Vivotek Corporation. This vulnerability stems from the lack of authentication measures or insufficient authentication strength in network systems or products",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-10256"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009357"
          },
          {
            "db": "VULHUB",
            "id": "VHN-141784"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-10256",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009357",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-458",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-141784",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-141784"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009357"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-458"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10256"
          }
        ]
      },
      "id": "VAR-201909-1474",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-141784"
          }
        ],
        "trust": 0.9783784
      },
      "last_update_date": "2024-11-23T22:44:49.698000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Cybersecurity Management Solution",
            "trust": 0.8,
            "url": "https://www.vivotek.com/cybersecurity"
          },
          {
            "title": "VVTK\u2212SA-2019-001",
            "trust": 0.8,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-001-v1.pdf"
          },
          {
            "title": "VIVOTEK IPCam Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=98051"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009357"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-458"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-287",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-141784"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009357"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10256"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-001-v1.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://www.vivotek.com/cybersecurity"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-10256"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10256"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-141784"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009357"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-458"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10256"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-141784"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009357"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-458"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-10256"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-09-10T00:00:00",
            "db": "VULHUB",
            "id": "VHN-141784"
          },
          {
            "date": "2019-09-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-009357"
          },
          {
            "date": "2019-09-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201909-458"
          },
          {
            "date": "2019-09-10T19:15:10.233000",
            "db": "NVD",
            "id": "CVE-2019-10256"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-141784"
          },
          {
            "date": "2019-09-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-009357"
          },
          {
            "date": "2020-08-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201909-458"
          },
          {
            "date": "2024-11-21T04:18:45.547000",
            "db": "NVD",
            "id": "CVE-2019-10256"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-458"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK IPCam Authentication vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009357"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "authorization issue",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-458"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201809-0168

    Vulnerability from variot - Updated: 2024-11-23 22:41

    VIVOTEK FD8177 The device contains a cross-site request forgery vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VIVOTEK FD8177 is a network camera product of Vivotek. There is a cross-site request forgery vulnerability in VIVOTEK FD8177 devices prior to XXXXXX-VVTK-xx06a. A remote attacker can exploit this vulnerability to hijack cgi commands

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0168",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "camera",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010297"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-209"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14769"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/h:vivotek:camera",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010297"
          }
        ]
      },
      "cve": "CVE-2018-14769",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "CVE-2018-14769",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.6,
                "id": "VHN-124961",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2018-14769",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-14769",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-14769",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201809-209",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124961",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124961"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010297"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-209"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14769"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK FD8177 The device contains a cross-site request forgery vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VIVOTEK FD8177 is a network camera product of Vivotek. There is a cross-site request forgery vulnerability in VIVOTEK FD8177 devices prior to XXXXXX-VVTK-xx06a. A remote attacker can exploit this vulnerability to hijack cgi commands",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010297"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124961"
          }
        ],
        "trust": 0.81
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14769",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010297",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-209",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-124961",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124961"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010297"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-209"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14769"
          }
        ]
      },
      "id": "VAR-201809-0168",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124961"
          }
        ],
        "trust": 0.9783784
      },
      "last_update_date": "2024-11-23T22:41:41.686000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "VVTK-SA-2018-004",
            "trust": 0.8,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-004-v1.pdf"
          },
          {
            "title": "Cybersecurity",
            "trust": 0.8,
            "url": "https://www.vivotek.com/website/support/cybersecurity"
          },
          {
            "title": "VIVOTEK FD8177 Fixes for cross-site request forgery vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84545"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010297"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-209"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-352",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124961"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010297"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14769"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-004-v1.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://www.vivotek.com/website/support/cybersecurity"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14769"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14769"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124961"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010297"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-209"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14769"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-124961"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010297"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-209"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14769"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-09-05T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124961"
          },
          {
            "date": "2018-12-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-010297"
          },
          {
            "date": "2018-09-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201809-209"
          },
          {
            "date": "2018-09-05T21:29:00.657000",
            "db": "NVD",
            "id": "CVE-2018-14769"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-11-13T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124961"
          },
          {
            "date": "2018-12-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-010297"
          },
          {
            "date": "2018-09-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201809-209"
          },
          {
            "date": "2024-11-21T03:49:44.913000",
            "db": "NVD",
            "id": "CVE-2018-14769"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-209"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK FD8177 Device cross-site request forgery vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010297"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "cross-site request forgery",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201809-209"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201909-1018

    Vulnerability from variot - Updated: 2024-11-23 21:51

    VIVOTEK IP Camera devices with firmware before 0x20x allow a denial of service via a crafted HTTP header. VIVOTEK IP Camera There is an input validation vulnerability in the device firmware.Service operation interruption (DoS) There is a possibility of being put into a state. Vivotek VIVOTEK IP Camera is an IP camera produced by Taiwan Vivotek Corporation. Vivotek VIVOTEK IP Cameras with firmware versions earlier than 0x20x have a security vulnerability

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201909-1018",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "camera",
            "scope": "lt",
            "trust": 0.8,
            "vendor": "vivotek",
            "version": "0x20x"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009493"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14458"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/h:vivotek:camera",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009493"
          }
        ]
      },
      "cve": "CVE-2019-14458",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2019-14458",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "VHN-146406",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2019-14458",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2019-14458",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2019-14458",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2019-14458",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201909-873",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-146406",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-146406"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009493"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-873"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14458"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK IP Camera devices with firmware before 0x20x allow a denial of service via a crafted HTTP header. VIVOTEK IP Camera There is an input validation vulnerability in the device firmware.Service operation interruption (DoS) There is a possibility of being put into a state. Vivotek VIVOTEK IP Camera is an IP camera produced by Taiwan Vivotek Corporation. Vivotek VIVOTEK IP Cameras with firmware versions earlier than 0x20x have a security vulnerability",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-14458"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009493"
          },
          {
            "db": "VULHUB",
            "id": "VHN-146406"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-14458",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009493",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-873",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-146406",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-146406"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009493"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-873"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14458"
          }
        ]
      },
      "id": "VAR-201909-1018",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-146406"
          }
        ],
        "trust": 0.9783784
      },
      "last_update_date": "2024-11-23T21:51:58.145000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "VVTK-SA-2019-002",
            "trust": 0.8,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
          },
          {
            "title": "Cybersecurity Management Solution",
            "trust": 0.8,
            "url": "https://www.vivotek.com/cybersecurity"
          },
          {
            "title": "Vivotek VIVOTEK IP Camera Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=98399"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009493"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-873"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-20",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-146406"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009493"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14458"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://www.vivotek.com/cybersecurity"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-14458"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-14458"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-146406"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009493"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-873"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14458"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-146406"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009493"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-873"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14458"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-09-18T00:00:00",
            "db": "VULHUB",
            "id": "VHN-146406"
          },
          {
            "date": "2019-09-24T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-009493"
          },
          {
            "date": "2019-09-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201909-873"
          },
          {
            "date": "2019-09-18T18:15:10.843000",
            "db": "NVD",
            "id": "CVE-2019-14458"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-146406"
          },
          {
            "date": "2019-09-24T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-009493"
          },
          {
            "date": "2020-08-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201909-873"
          },
          {
            "date": "2024-11-21T04:26:47.060000",
            "db": "NVD",
            "id": "CVE-2019-14458"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-873"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "VIVOTEK IP Camera Vulnerability related to input validation in device firmware",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-009493"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "input validation error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201909-873"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201808-0430

    Vulnerability from variot - Updated: 2024-11-23 21:38

    Various VIVOTEK FD8, FD9, FE9, IB8, IB9, IP9, IZ9, MS9, SD9, and other devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code. plural Various VIVOTEK The product contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VIVOTEK (Jingrui Communication Co., Ltd.) is a manufacturer of network cameras and audio and video servers. A command injection vulnerability exists in the VIVOTEK network camera with firmware version lower than XXXXXX-VVTK-0X06a. Vivotek FD8, etc. are Vivotek's network camera products of different models. The following products are affected: VIVOTEK FD8; FD9; FE9; IB8; IB9; IP9; IZ9; MS9; SD9*, etc

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201808-0430",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "camera",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "camera",
            "scope": null,
            "trust": 0.8,
            "vendor": "vivotek",
            "version": null
          },
          {
            "model": "network camera \u003cxxxxxx-vvtk-0x06a",
            "scope": null,
            "trust": 0.6,
            "vendor": "vivotek",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06201"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010290"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-922"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14768"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/h:vivotek:camera",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010290"
          }
        ]
      },
      "cve": "CVE-2018-14768",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CVE-2018-14768",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "CNVD-2019-06201",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.0,
                "id": "VHN-124960",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2018-14768",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.8,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-14768",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-14768",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-06201",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201808-922",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-124960",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06201"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124960"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010290"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-922"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14768"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Various VIVOTEK FD8*, FD9*, FE9*, IB8*, IB9*, IP9*, IZ9*, MS9*, SD9*, and other devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code. plural Various VIVOTEK The product contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VIVOTEK (Jingrui Communication Co., Ltd.) is a manufacturer of network cameras and audio and video servers. A command injection vulnerability exists in the VIVOTEK network camera with firmware version lower than XXXXXX-VVTK-0X06a. Vivotek FD8*, etc. are Vivotek\u0027s network camera products of different models. The following products are affected: VIVOTEK FD8*; FD9*; FE9*; IB8*; IB9*; IP9*; IZ9*; MS9*; SD9*, etc",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-14768"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010290"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-06201"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124960"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-14768",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010290",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-922",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-06201",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-124960",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06201"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124960"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010290"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-922"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14768"
          }
        ]
      },
      "id": "VAR-201808-0430",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06201"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124960"
          }
        ],
        "trust": 1.4516892
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06201"
          }
        ]
      },
      "last_update_date": "2024-11-23T21:38:26.638000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Cybersecurity",
            "trust": 0.8,
            "url": "https://www.vivotek.com/cybersecurity"
          },
          {
            "title": "VVTK-SA-2018-003",
            "trust": 0.8,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
          },
          {
            "title": "VIVOTEK Network Camera Command Injection Vulnerability Patch",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/155261"
          },
          {
            "title": "Multiple VIVOTEK Product security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=84347"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06201"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010290"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-922"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-77",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-124960"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010290"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14768"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.3,
            "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://www.vivotek.com/website/support/cybersecurity/"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14768"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-14768"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06201"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124960"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010290"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-922"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14768"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-06201"
          },
          {
            "db": "VULHUB",
            "id": "VHN-124960"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010290"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-922"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-14768"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-03-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-06201"
          },
          {
            "date": "2018-08-29T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124960"
          },
          {
            "date": "2018-12-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-010290"
          },
          {
            "date": "2018-08-30T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201808-922"
          },
          {
            "date": "2018-08-29T19:29:00.500000",
            "db": "NVD",
            "id": "CVE-2018-14768"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-03-06T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-06201"
          },
          {
            "date": "2020-08-24T00:00:00",
            "db": "VULHUB",
            "id": "VHN-124960"
          },
          {
            "date": "2018-12-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-010290"
          },
          {
            "date": "2020-10-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201808-922"
          },
          {
            "date": "2024-11-21T03:49:44.753000",
            "db": "NVD",
            "id": "CVE-2018-14768"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-922"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Various VIVOTEK Command injection vulnerability in the product",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-010290"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-922"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2019-14458 (GCVE-0-2019-14458)

    Vulnerability from nvd – Published: 2019-09-18 17:42 – Updated: 2024-08-05 00:19
    VLAI
    Summary
    VIVOTEK IP Camera devices with firmware before 0x20x allow a denial of service via a crafted HTTP header.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T00:19:41.122Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.vivotek.com/cybersecurity"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "VIVOTEK IP Camera devices with firmware before 0x20x allow a denial of service via a crafted HTTP header."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-18T17:42:25.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.vivotek.com/cybersecurity"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-14458",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VIVOTEK IP Camera devices with firmware before 0x20x allow a denial of service via a crafted HTTP header."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.vivotek.com/cybersecurity",
                  "refsource": "MISC",
                  "url": "https://www.vivotek.com/cybersecurity"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-14458",
        "datePublished": "2019-09-18T17:42:08.000Z",
        "dateReserved": "2019-07-31T00:00:00.000Z",
        "dateUpdated": "2024-08-05T00:19:41.122Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-10256 (GCVE-0-2019-10256)

    Vulnerability from nvd – Published: 2019-09-10 18:02 – Updated: 2024-08-04 22:17
    VLAI
    Summary
    An authentication bypass vulnerability in VIVOTEK IPCam versions prior to 0x13a was found.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:17:19.660Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.vivotek.com/cybersecurity"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-001-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An authentication bypass vulnerability in VIVOTEK IPCam versions prior to 0x13a was found."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-10T18:02:45.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.vivotek.com/cybersecurity"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-001-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-10256",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An authentication bypass vulnerability in VIVOTEK IPCam versions prior to 0x13a was found."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.vivotek.com/cybersecurity",
                  "refsource": "MISC",
                  "url": "https://www.vivotek.com/cybersecurity"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-001-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-001-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-10256",
        "datePublished": "2019-09-10T18:02:45.000Z",
        "dateReserved": "2019-03-28T00:00:00.000Z",
        "dateUpdated": "2024-08-04T22:17:19.660Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-14457 (GCVE-0-2019-14457)

    Vulnerability from nvd – Published: 2019-09-10 17:48 – Updated: 2024-08-05 00:19
    VLAI
    Summary
    VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T00:19:41.197Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-10T17:48:48.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-14457",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-14457",
        "datePublished": "2019-09-10T17:48:48.000Z",
        "dateReserved": "2019-07-31T00:00:00.000Z",
        "dateUpdated": "2024-08-05T00:19:41.197Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-18244 (GCVE-0-2018-18244)

    Vulnerability from nvd – Published: 2019-01-03 20:00 – Updated: 2024-08-05 11:01
    VLAI
    Summary
    Cross-site scripting in syslog.html in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript code via an HTTP Referer Header.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-12-28 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:01:14.929Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-12-28T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting in syslog.html in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript code via an HTTP Referer Header."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-03T19:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-18244",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting in syslog.html in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript code via an HTTP Referer Header."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244",
                  "refsource": "MISC",
                  "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-18244",
        "datePublished": "2019-01-03T20:00:00.000Z",
        "dateReserved": "2018-10-11T00:00:00.000Z",
        "dateUpdated": "2024-08-05T11:01:14.929Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-18005 (GCVE-0-2018-18005)

    Vulnerability from nvd – Published: 2019-01-03 20:00 – Updated: 2024-08-05 11:01
    VLAI
    Summary
    Cross-site scripting in event_script.js in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript via a URL query string parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-12-28 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:01:14.781Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-12-28T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting in event_script.js in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript via a URL query string parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-03T19:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-18005",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting in event_script.js in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript via a URL query string parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244",
                  "refsource": "MISC",
                  "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-18005",
        "datePublished": "2019-01-03T20:00:00.000Z",
        "dateReserved": "2018-10-05T00:00:00.000Z",
        "dateUpdated": "2024-08-05T11:01:14.781Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-18004 (GCVE-0-2018-18004)

    Vulnerability from nvd – Published: 2019-01-03 20:00 – Updated: 2024-08-05 11:01
    VLAI
    Summary
    Incorrect Access Control in mod_inetd.cgi in VIVOTEK Network Camera Series products with firmware before XXXXXX-VVTK-0X09a allows remote attackers to enable arbitrary system services via a URL parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-12-28 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:01:14.848Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-12-28T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Incorrect Access Control in mod_inetd.cgi in VIVOTEK Network Camera Series products with firmware before XXXXXX-VVTK-0X09a allows remote attackers to enable arbitrary system services via a URL parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-03T19:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-18004",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Incorrect Access Control in mod_inetd.cgi in VIVOTEK Network Camera Series products with firmware before XXXXXX-VVTK-0X09a allows remote attackers to enable arbitrary system services via a URL parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244",
                  "refsource": "MISC",
                  "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-18004",
        "datePublished": "2019-01-03T20:00:00.000Z",
        "dateReserved": "2018-10-05T00:00:00.000Z",
        "dateUpdated": "2024-08-05T11:01:14.848Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14771 (GCVE-0-2018-14771)

    Vulnerability from nvd – Published: 2018-09-05 21:00 – Updated: 2024-08-05 09:38
    VLAI
    Summary
    VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-08-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.955Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.vivotek.com/website/support/cybersecurity/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-08-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-09-05T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.vivotek.com/website/support/cybersecurity/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-14771",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.vivotek.com/website/support/cybersecurity/",
                  "refsource": "MISC",
                  "url": "https://www.vivotek.com/website/support/cybersecurity/"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-14771",
        "datePublished": "2018-09-05T21:00:00.000Z",
        "dateReserved": "2018-07-31T00:00:00.000Z",
        "dateUpdated": "2024-08-05T09:38:13.955Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14770 (GCVE-0-2018-14770)

    Vulnerability from nvd – Published: 2018-09-05 21:00 – Updated: 2024-08-05 09:38
    VLAI
    Summary
    VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/device_service).
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-08-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.731Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.vivotek.com/website/support/cybersecurity/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-08-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/device_service)."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-09-05T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.vivotek.com/website/support/cybersecurity/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-14770",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/device_service)."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.vivotek.com/website/support/cybersecurity/",
                  "refsource": "MISC",
                  "url": "https://www.vivotek.com/website/support/cybersecurity/"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-14770",
        "datePublished": "2018-09-05T21:00:00.000Z",
        "dateReserved": "2018-07-31T00:00:00.000Z",
        "dateUpdated": "2024-08-05T09:38:13.731Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14769 (GCVE-0-2018-14769)

    Vulnerability from nvd – Published: 2018-09-05 21:00 – Updated: 2024-08-05 09:38
    VLAI
    Summary
    VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow CSRF.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-08-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.671Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-004-v1.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.vivotek.com/website/support/cybersecurity"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-08-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow CSRF."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-09-05T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-004-v1.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.vivotek.com/website/support/cybersecurity"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-14769",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow CSRF."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-004-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-004-v1.pdf"
                },
                {
                  "name": "https://www.vivotek.com/website/support/cybersecurity",
                  "refsource": "MISC",
                  "url": "https://www.vivotek.com/website/support/cybersecurity"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-14769",
        "datePublished": "2018-09-05T21:00:00.000Z",
        "dateReserved": "2018-07-31T00:00:00.000Z",
        "dateUpdated": "2024-08-05T09:38:13.671Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14768 (GCVE-0-2018-14768)

    Vulnerability from nvd – Published: 2018-08-29 19:00 – Updated: 2024-08-05 09:38
    VLAI
    Summary
    Various VIVOTEK FD8*, FD9*, FE9*, IB8*, IB9*, IP9*, IZ9*, MS9*, SD9*, and other devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-08-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.418Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.vivotek.com/website/support/cybersecurity/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-08-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Various VIVOTEK FD8*, FD9*, FE9*, IB8*, IB9*, IP9*, IZ9*, MS9*, SD9*, and other devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-08-29T18:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.vivotek.com/website/support/cybersecurity/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-14768",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Various VIVOTEK FD8*, FD9*, FE9*, IB8*, IB9*, IP9*, IZ9*, MS9*, SD9*, and other devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
                },
                {
                  "name": "https://www.vivotek.com/website/support/cybersecurity/",
                  "refsource": "CONFIRM",
                  "url": "https://www.vivotek.com/website/support/cybersecurity/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-14768",
        "datePublished": "2018-08-29T19:00:00.000Z",
        "dateReserved": "2018-07-31T00:00:00.000Z",
        "dateUpdated": "2024-08-05T09:38:13.418Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-14458 (GCVE-0-2019-14458)

    Vulnerability from cvelistv5 – Published: 2019-09-18 17:42 – Updated: 2024-08-05 00:19
    VLAI
    Summary
    VIVOTEK IP Camera devices with firmware before 0x20x allow a denial of service via a crafted HTTP header.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T00:19:41.122Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.vivotek.com/cybersecurity"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "VIVOTEK IP Camera devices with firmware before 0x20x allow a denial of service via a crafted HTTP header."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-18T17:42:25.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.vivotek.com/cybersecurity"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-14458",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VIVOTEK IP Camera devices with firmware before 0x20x allow a denial of service via a crafted HTTP header."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.vivotek.com/cybersecurity",
                  "refsource": "MISC",
                  "url": "https://www.vivotek.com/cybersecurity"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-14458",
        "datePublished": "2019-09-18T17:42:08.000Z",
        "dateReserved": "2019-07-31T00:00:00.000Z",
        "dateUpdated": "2024-08-05T00:19:41.122Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-10256 (GCVE-0-2019-10256)

    Vulnerability from cvelistv5 – Published: 2019-09-10 18:02 – Updated: 2024-08-04 22:17
    VLAI
    Summary
    An authentication bypass vulnerability in VIVOTEK IPCam versions prior to 0x13a was found.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T22:17:19.660Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.vivotek.com/cybersecurity"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-001-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An authentication bypass vulnerability in VIVOTEK IPCam versions prior to 0x13a was found."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-10T18:02:45.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.vivotek.com/cybersecurity"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-001-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-10256",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An authentication bypass vulnerability in VIVOTEK IPCam versions prior to 0x13a was found."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.vivotek.com/cybersecurity",
                  "refsource": "MISC",
                  "url": "https://www.vivotek.com/cybersecurity"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-001-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-001-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-10256",
        "datePublished": "2019-09-10T18:02:45.000Z",
        "dateReserved": "2019-03-28T00:00:00.000Z",
        "dateUpdated": "2024-08-04T22:17:19.660Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-14457 (GCVE-0-2019-14457)

    Vulnerability from cvelistv5 – Published: 2019-09-10 17:48 – Updated: 2024-08-05 00:19
    VLAI
    Summary
    VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T00:19:41.197Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-09-10T17:48:48.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-14457",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2019-002-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-14457",
        "datePublished": "2019-09-10T17:48:48.000Z",
        "dateReserved": "2019-07-31T00:00:00.000Z",
        "dateUpdated": "2024-08-05T00:19:41.197Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-18244 (GCVE-0-2018-18244)

    Vulnerability from cvelistv5 – Published: 2019-01-03 20:00 – Updated: 2024-08-05 11:01
    VLAI
    Summary
    Cross-site scripting in syslog.html in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript code via an HTTP Referer Header.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-12-28 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:01:14.929Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-12-28T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting in syslog.html in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript code via an HTTP Referer Header."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-03T19:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-18244",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting in syslog.html in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript code via an HTTP Referer Header."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244",
                  "refsource": "MISC",
                  "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-18244",
        "datePublished": "2019-01-03T20:00:00.000Z",
        "dateReserved": "2018-10-11T00:00:00.000Z",
        "dateUpdated": "2024-08-05T11:01:14.929Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-18005 (GCVE-0-2018-18005)

    Vulnerability from cvelistv5 – Published: 2019-01-03 20:00 – Updated: 2024-08-05 11:01
    VLAI
    Summary
    Cross-site scripting in event_script.js in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript via a URL query string parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-12-28 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:01:14.781Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-12-28T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting in event_script.js in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript via a URL query string parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-03T19:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-18005",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting in event_script.js in VIVOTEK Network Camera Series products with firmware 0x06x to 0x08x allows remote attackers to execute arbitrary JavaScript via a URL query string parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244",
                  "refsource": "MISC",
                  "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-18005",
        "datePublished": "2019-01-03T20:00:00.000Z",
        "dateReserved": "2018-10-05T00:00:00.000Z",
        "dateUpdated": "2024-08-05T11:01:14.781Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-18004 (GCVE-0-2018-18004)

    Vulnerability from cvelistv5 – Published: 2019-01-03 20:00 – Updated: 2024-08-05 11:01
    VLAI
    Summary
    Incorrect Access Control in mod_inetd.cgi in VIVOTEK Network Camera Series products with firmware before XXXXXX-VVTK-0X09a allows remote attackers to enable arbitrary system services via a URL parameter.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-12-28 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T11:01:14.848Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-12-28T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Incorrect Access Control in mod_inetd.cgi in VIVOTEK Network Camera Series products with firmware before XXXXXX-VVTK-0X09a allows remote attackers to enable arbitrary system services via a URL parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-03T19:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-18004",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Incorrect Access Control in mod_inetd.cgi in VIVOTEK Network Camera Series products with firmware before XXXXXX-VVTK-0X09a allows remote attackers to enable arbitrary system services via a URL parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244",
                  "refsource": "MISC",
                  "url": "https://blog.securityevaluators.com/vivotek-ip-camera-vulnerabilities-discovered-and-exploited-2e2531ecd244"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-006-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-18004",
        "datePublished": "2019-01-03T20:00:00.000Z",
        "dateReserved": "2018-10-05T00:00:00.000Z",
        "dateUpdated": "2024-08-05T11:01:14.848Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14770 (GCVE-0-2018-14770)

    Vulnerability from cvelistv5 – Published: 2018-09-05 21:00 – Updated: 2024-08-05 09:38
    VLAI
    Summary
    VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/device_service).
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-08-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.731Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.vivotek.com/website/support/cybersecurity/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-08-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/device_service)."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-09-05T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.vivotek.com/website/support/cybersecurity/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-14770",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/device_service)."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.vivotek.com/website/support/cybersecurity/",
                  "refsource": "MISC",
                  "url": "https://www.vivotek.com/website/support/cybersecurity/"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-14770",
        "datePublished": "2018-09-05T21:00:00.000Z",
        "dateReserved": "2018-07-31T00:00:00.000Z",
        "dateUpdated": "2024-08-05T09:38:13.731Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14771 (GCVE-0-2018-14771)

    Vulnerability from cvelistv5 – Published: 2018-09-05 21:00 – Updated: 2024-08-05 09:38
    VLAI
    Summary
    VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-08-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.955Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.vivotek.com/website/support/cybersecurity/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-08-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-09-05T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.vivotek.com/website/support/cybersecurity/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-14771",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.vivotek.com/website/support/cybersecurity/",
                  "refsource": "MISC",
                  "url": "https://www.vivotek.com/website/support/cybersecurity/"
                },
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-003-v1.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-14771",
        "datePublished": "2018-09-05T21:00:00.000Z",
        "dateReserved": "2018-07-31T00:00:00.000Z",
        "dateUpdated": "2024-08-05T09:38:13.955Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-14769 (GCVE-0-2018-14769)

    Vulnerability from cvelistv5 – Published: 2018-09-05 21:00 – Updated: 2024-08-05 09:38
    VLAI
    Summary
    VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow CSRF.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2018-08-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T09:38:13.671Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-004-v1.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.vivotek.com/website/support/cybersecurity"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-08-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow CSRF."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-09-05T21:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-004-v1.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.vivotek.com/website/support/cybersecurity"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-14769",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow CSRF."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-004-v1.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://download.vivotek.com/downloadfile/support/cyber-security/vvtk-sa-2018-004-v1.pdf"
                },
                {
                  "name": "https://www.vivotek.com/website/support/cybersecurity",
                  "refsource": "MISC",
                  "url": "https://www.vivotek.com/website/support/cybersecurity"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-14769",
        "datePublished": "2018-09-05T21:00:00.000Z",
        "dateReserved": "2018-07-31T00:00:00.000Z",
        "dateUpdated": "2024-08-05T09:38:13.671Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",