Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for bpc_9102s_firmware by phoenixcontact

    CVE-2023-46144 (GCVE-0-2023-46144)

    Vulnerability from nvd – Published: 2023-12-14 14:08 – Updated: 2024-10-01 06:18
    VLAI
    Title
    PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check
    Summary
    A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.
    CWE
    • CWE-494 - Download of Code Without Integrity Check
    Assigner
    Credits
    Reid Wightman of Dragos, Inc.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:37:39.934Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AXC F 1152",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AXC F 2152",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AXC F 3152",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "BPC 9102S",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EPC 1502",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EPC 1522",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PLCnext Engineer",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "RFC 4072R",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "RFC 4072S",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Reid Wightman of Dragos, Inc."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
                }
              ],
              "value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-494",
                  "description": "CWE-494: Download of Code Without Integrity Check",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-01T06:18:18.730Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-058",
            "defect": [
              "CERT@VDE#64611"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-46144",
        "datePublished": "2023-12-14T14:08:07.244Z",
        "dateReserved": "2023-10-17T07:04:03.577Z",
        "dateUpdated": "2024-10-01T06:18:18.730Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46142 (GCVE-0-2023-46142)

    Vulnerability from nvd – Published: 2023-12-14 14:05 – Updated: 2024-08-02 20:37
    VLAI
    Title
    PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control
    Summary
    A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    Credits
    Reid Wightman of Dragos, Inc.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:37:39.840Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AXC F 1152",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AXC F 2152",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AXC F 3152",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "BPC 9102S",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EPC 1502",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EPC 1522",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PLCnext Engineer",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "RFC 4072R",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "RFC 4072S",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Reid Wightman of Dragos, Inc."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
                }
              ],
              "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-14T14:05:35.741Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-056",
            "defect": [
              "CERT@VDE#64609"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-46142",
        "datePublished": "2023-12-14T14:05:35.741Z",
        "dateReserved": "2023-10-17T07:04:03.576Z",
        "dateUpdated": "2024-08-02T20:37:39.840Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46144 (GCVE-0-2023-46144)

    Vulnerability from cvelistv5 – Published: 2023-12-14 14:08 – Updated: 2024-10-01 06:18
    VLAI
    Title
    PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check
    Summary
    A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.
    CWE
    • CWE-494 - Download of Code Without Integrity Check
    Assigner
    Credits
    Reid Wightman of Dragos, Inc.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:37:39.934Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AXC F 1152",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AXC F 2152",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AXC F 3152",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "BPC 9102S",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EPC 1502",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EPC 1522",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PLCnext Engineer",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "RFC 4072R",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "RFC 4072S",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Reid Wightman of Dragos, Inc."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
                }
              ],
              "value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-494",
                  "description": "CWE-494: Download of Code Without Integrity Check",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-01T06:18:18.730Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-058",
            "defect": [
              "CERT@VDE#64611"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-46144",
        "datePublished": "2023-12-14T14:08:07.244Z",
        "dateReserved": "2023-10-17T07:04:03.577Z",
        "dateUpdated": "2024-10-01T06:18:18.730Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-46142 (GCVE-0-2023-46142)

    Vulnerability from cvelistv5 – Published: 2023-12-14 14:05 – Updated: 2024-08-02 20:37
    VLAI
    Title
    PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control
    Summary
    A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    Credits
    Reid Wightman of Dragos, Inc.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T20:37:39.840Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AXC F 1152",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AXC F 2152",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "AXC F 3152",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "BPC 9102S",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EPC 1502",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "EPC 1522",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PLCnext Engineer",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "RFC 4072R",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "RFC 4072S",
              "vendor": "PHOENIX CONTACT",
              "versions": [
                {
                  "lessThanOrEqual": "2024.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Reid Wightman of Dragos, Inc."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
                }
              ],
              "value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-14T14:05:35.741Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-056",
            "defect": [
              "CERT@VDE#64609"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-46142",
        "datePublished": "2023-12-14T14:05:35.741Z",
        "dateReserved": "2023-10-17T07:04:03.576Z",
        "dateUpdated": "2024-08-02T20:37:39.840Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }