Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
8 vulnerabilities found for bl-wr9000_firmware by lb-link
CVE-2026-4228 (GCVE-0-2026-4228)
Vulnerability from nvd – Published: 2026-03-16 08:02 – Updated: 2026-03-16 16:41
VLAI?
Title
LB-LINK BL-WR9000 set_wifi sub_458754 command injection
Summary
A vulnerability was detected in LB-LINK BL-WR9000 2.4.9. This affects the function sub_458754 of the file /goform/set_wifi. The manipulation results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4228",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T16:40:53.546924Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T16:41:59.288Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BL-WR9000",
"vendor": "LB-LINK",
"versions": [
{
"status": "affected",
"version": "2.4.9"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jfkk (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in LB-LINK BL-WR9000 2.4.9. This affects the function sub_458754 of the file /goform/set_wifi. The manipulation results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T08:02:10.790Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-351151 | LB-LINK BL-WR9000 set_wifi sub_458754 command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.351151"
},
{
"name": "VDB-351151 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.351151"
},
{
"name": "Submit #771210 | LB-LINK BL-WR9000 V2.4.9 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.771210"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_wlanpswencry%20command%20injection_EN.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-15T19:46:26.000Z",
"value": "VulDB entry last update"
}
],
"title": "LB-LINK BL-WR9000 set_wifi sub_458754 command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-4228",
"datePublished": "2026-03-16T08:02:10.790Z",
"dateReserved": "2026-03-15T18:41:17.685Z",
"dateUpdated": "2026-03-16T16:41:59.288Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-4227 (GCVE-0-2026-4227)
Vulnerability from nvd – Published: 2026-03-16 08:02 – Updated: 2026-03-16 16:48
VLAI?
Title
LB-LINK BL-WR9000 get_hidessid_cfg sub_44D844 buffer overflow
Summary
A security vulnerability has been detected in LB-LINK BL-WR9000 2.4.9. The impacted element is the function sub_44D844 of the file /goform/get_hidessid_cfg. The manipulation leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4227",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T16:47:26.831500Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T16:48:52.842Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BL-WR9000",
"vendor": "LB-LINK",
"versions": [
{
"status": "affected",
"version": "2.4.9"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jfkk (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in LB-LINK BL-WR9000 2.4.9. The impacted element is the function sub_44D844 of the file /goform/get_hidessid_cfg. The manipulation leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T08:02:08.436Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-351150 | LB-LINK BL-WR9000 get_hidessid_cfg sub_44D844 buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.351150"
},
{
"name": "VDB-351150 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.351150"
},
{
"name": "Submit #771209 | LB-LINK BL-WR9000 V2.4.9 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.771209"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_HideSSID%20stack%20overflow_EN.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-15T19:46:25.000Z",
"value": "VulDB entry last update"
}
],
"title": "LB-LINK BL-WR9000 get_hidessid_cfg sub_44D844 buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-4227",
"datePublished": "2026-03-16T08:02:08.436Z",
"dateReserved": "2026-03-15T18:41:15.204Z",
"dateUpdated": "2026-03-16T16:48:52.842Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-4226 (GCVE-0-2026-4226)
Vulnerability from nvd – Published: 2026-03-16 07:32 – Updated: 2026-03-16 17:06
VLAI?
Title
LB-LINK BL-WR9000 get_virtual_cfg sub_44E8D0 stack-based overflow
Summary
A weakness has been identified in LB-LINK BL-WR9000 2.4.9. The affected element is the function sub_44E8D0 of the file /goform/get_virtual_cfg. Executing a manipulation can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4226",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T17:02:09.943914Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T17:06:42.899Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BL-WR9000",
"vendor": "LB-LINK",
"versions": [
{
"status": "affected",
"version": "2.4.9"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jfkk (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in LB-LINK BL-WR9000 2.4.9. The affected element is the function sub_44E8D0 of the file /goform/get_virtual_cfg. Executing a manipulation can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T07:32:10.845Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-351149 | LB-LINK BL-WR9000 get_virtual_cfg sub_44E8D0 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.351149"
},
{
"name": "VDB-351149 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.351149"
},
{
"name": "Submit #771207 | LB-LINK BL-WR9000 V2.4.9 over",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.771207"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_VirtualRules%20stack%20overflow_EN.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-15T19:46:24.000Z",
"value": "VulDB entry last update"
}
],
"title": "LB-LINK BL-WR9000 get_virtual_cfg sub_44E8D0 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-4226",
"datePublished": "2026-03-16T07:32:10.845Z",
"dateReserved": "2026-03-15T18:41:08.804Z",
"dateUpdated": "2026-03-16T17:06:42.899Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-26801 (GCVE-0-2023-26801)
Vulnerability from nvd – Published: 2023-03-26 00:00 – Updated: 2025-05-05 16:03
VLAI?
Summary
LB-LINK BL-AC1900_2.0 v1.0.1, LB-LINK BL-WR9000 v2.4.9, LB-LINK BL-X26 v1.2.5, and LB-LINK BL-LTE300 v1.0.8 were discovered to contain a command injection vulnerability via the mac, time1, and time2 parameters at /goform/set_LimitClient_cfg.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:53:54.605Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/winmt/my-vuls/tree/main/LB-LINK%20BL-AC1900%2C%20BL-WR9000%2C%20BL-X26%20and%20BL-LTE300%20Wireless%20Routers"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-26801",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:31:35.396052Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:03:35.752Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "LB-LINK BL-AC1900_2.0 v1.0.1, LB-LINK BL-WR9000 v2.4.9, LB-LINK BL-X26 v1.2.5, and LB-LINK BL-LTE300 v1.0.8 were discovered to contain a command injection vulnerability via the mac, time1, and time2 parameters at /goform/set_LimitClient_cfg."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T20:18:08.752Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/winmt/my-vuls/tree/main/LB-LINK%20BL-AC1900%2C%20BL-WR9000%2C%20BL-X26%20and%20BL-LTE300%20Wireless%20Routers"
},
{
"url": "https://www.akamai.com/blog/security-research/cve-2023-26801-exploited-spreading-mirai-botnet"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-26801",
"datePublished": "2023-03-26T00:00:00.000Z",
"dateReserved": "2023-02-27T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:03:35.752Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-4228 (GCVE-0-2026-4228)
Vulnerability from cvelistv5 – Published: 2026-03-16 08:02 – Updated: 2026-03-16 16:41
VLAI?
Title
LB-LINK BL-WR9000 set_wifi sub_458754 command injection
Summary
A vulnerability was detected in LB-LINK BL-WR9000 2.4.9. This affects the function sub_458754 of the file /goform/set_wifi. The manipulation results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4228",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T16:40:53.546924Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T16:41:59.288Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BL-WR9000",
"vendor": "LB-LINK",
"versions": [
{
"status": "affected",
"version": "2.4.9"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jfkk (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in LB-LINK BL-WR9000 2.4.9. This affects the function sub_458754 of the file /goform/set_wifi. The manipulation results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T08:02:10.790Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-351151 | LB-LINK BL-WR9000 set_wifi sub_458754 command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.351151"
},
{
"name": "VDB-351151 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.351151"
},
{
"name": "Submit #771210 | LB-LINK BL-WR9000 V2.4.9 Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.771210"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_wlanpswencry%20command%20injection_EN.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-15T19:46:26.000Z",
"value": "VulDB entry last update"
}
],
"title": "LB-LINK BL-WR9000 set_wifi sub_458754 command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-4228",
"datePublished": "2026-03-16T08:02:10.790Z",
"dateReserved": "2026-03-15T18:41:17.685Z",
"dateUpdated": "2026-03-16T16:41:59.288Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-4227 (GCVE-0-2026-4227)
Vulnerability from cvelistv5 – Published: 2026-03-16 08:02 – Updated: 2026-03-16 16:48
VLAI?
Title
LB-LINK BL-WR9000 get_hidessid_cfg sub_44D844 buffer overflow
Summary
A security vulnerability has been detected in LB-LINK BL-WR9000 2.4.9. The impacted element is the function sub_44D844 of the file /goform/get_hidessid_cfg. The manipulation leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4227",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T16:47:26.831500Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T16:48:52.842Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BL-WR9000",
"vendor": "LB-LINK",
"versions": [
{
"status": "affected",
"version": "2.4.9"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jfkk (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in LB-LINK BL-WR9000 2.4.9. The impacted element is the function sub_44D844 of the file /goform/get_hidessid_cfg. The manipulation leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T08:02:08.436Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-351150 | LB-LINK BL-WR9000 get_hidessid_cfg sub_44D844 buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.351150"
},
{
"name": "VDB-351150 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.351150"
},
{
"name": "Submit #771209 | LB-LINK BL-WR9000 V2.4.9 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.771209"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_HideSSID%20stack%20overflow_EN.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-15T19:46:25.000Z",
"value": "VulDB entry last update"
}
],
"title": "LB-LINK BL-WR9000 get_hidessid_cfg sub_44D844 buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-4227",
"datePublished": "2026-03-16T08:02:08.436Z",
"dateReserved": "2026-03-15T18:41:15.204Z",
"dateUpdated": "2026-03-16T16:48:52.842Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-4226 (GCVE-0-2026-4226)
Vulnerability from cvelistv5 – Published: 2026-03-16 07:32 – Updated: 2026-03-16 17:06
VLAI?
Title
LB-LINK BL-WR9000 get_virtual_cfg sub_44E8D0 stack-based overflow
Summary
A weakness has been identified in LB-LINK BL-WR9000 2.4.9. The affected element is the function sub_44E8D0 of the file /goform/get_virtual_cfg. Executing a manipulation can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4226",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T17:02:09.943914Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T17:06:42.899Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BL-WR9000",
"vendor": "LB-LINK",
"versions": [
{
"status": "affected",
"version": "2.4.9"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jfkk (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in LB-LINK BL-WR9000 2.4.9. The affected element is the function sub_44E8D0 of the file /goform/get_virtual_cfg. Executing a manipulation can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T07:32:10.845Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-351149 | LB-LINK BL-WR9000 get_virtual_cfg sub_44E8D0 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.351149"
},
{
"name": "VDB-351149 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.351149"
},
{
"name": "Submit #771207 | LB-LINK BL-WR9000 V2.4.9 over",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.771207"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/glkfc/IoT-Vulnerability/blob/main/LB-LINK/LB-LINK_VirtualRules%20stack%20overflow_EN.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-15T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-15T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-15T19:46:24.000Z",
"value": "VulDB entry last update"
}
],
"title": "LB-LINK BL-WR9000 get_virtual_cfg sub_44E8D0 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-4226",
"datePublished": "2026-03-16T07:32:10.845Z",
"dateReserved": "2026-03-15T18:41:08.804Z",
"dateUpdated": "2026-03-16T17:06:42.899Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-26801 (GCVE-0-2023-26801)
Vulnerability from cvelistv5 – Published: 2023-03-26 00:00 – Updated: 2025-05-05 16:03
VLAI?
Summary
LB-LINK BL-AC1900_2.0 v1.0.1, LB-LINK BL-WR9000 v2.4.9, LB-LINK BL-X26 v1.2.5, and LB-LINK BL-LTE300 v1.0.8 were discovered to contain a command injection vulnerability via the mac, time1, and time2 parameters at /goform/set_LimitClient_cfg.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:53:54.605Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/winmt/my-vuls/tree/main/LB-LINK%20BL-AC1900%2C%20BL-WR9000%2C%20BL-X26%20and%20BL-LTE300%20Wireless%20Routers"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-26801",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:31:35.396052Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:03:35.752Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "LB-LINK BL-AC1900_2.0 v1.0.1, LB-LINK BL-WR9000 v2.4.9, LB-LINK BL-X26 v1.2.5, and LB-LINK BL-LTE300 v1.0.8 were discovered to contain a command injection vulnerability via the mac, time1, and time2 parameters at /goform/set_LimitClient_cfg."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T20:18:08.752Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/winmt/my-vuls/tree/main/LB-LINK%20BL-AC1900%2C%20BL-WR9000%2C%20BL-X26%20and%20BL-LTE300%20Wireless%20Routers"
},
{
"url": "https://www.akamai.com/blog/security-research/cve-2023-26801-exploited-spreading-mirai-botnet"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-26801",
"datePublished": "2023-03-26T00:00:00.000Z",
"dateReserved": "2023-02-27T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:03:35.752Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}