14 vulnerabilities found for apc_easy_ups_online_monitoring_software by schneider-electric
CVE-2023-29413 (GCVE-0-2023-29413)
Vulnerability from nvd – Published: 2023-04-18 20:50 – Updated: 2025-02-05 20:59
VLAI?
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause
Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor
service.
Severity ?
7.5 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Affected:
V2.5-GA-01-22320 , ≤ prior
(custom)
|
|||||||
|
|||||||||
Date Public ?
2023-04-11 07:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:45.947Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29413",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T20:59:10.323751Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:59:20.742Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GA-01-22320",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GS-01-22320",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n"
}
],
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-18T20:50:53.336Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-29413",
"datePublished": "2023-04-18T20:50:53.336Z",
"dateReserved": "2023-04-05T20:35:41.367Z",
"dateUpdated": "2025-02-05T20:59:20.742Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29412 (GCVE-0-2023-29412)
Vulnerability from nvd – Published: 2023-04-18 20:50 – Updated: 2025-02-05 21:00
VLAI?
Summary
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command
Injection') vulnerability exists that could cause remote code execution when manipulating
internal methods through Java RMI interface.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Affected:
V2.5-GA-01-22320 , ≤ prior
(custom)
|
|||||||
|
|||||||||
Date Public ?
2023-04-11 07:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.159Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29412",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T21:00:28.496674Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T21:00:38.906Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GA-01-22320",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GS-01-22320",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface.\n\n"
}
],
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T12:20:18.929Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-29412",
"datePublished": "2023-04-18T20:50:08.288Z",
"dateReserved": "2023-04-05T20:35:41.367Z",
"dateUpdated": "2025-02-05T21:00:38.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29411 (GCVE-0-2023-29411)
Vulnerability from nvd – Published: 2023-04-18 20:49 – Updated: 2025-02-05 21:22
VLAI?
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow
changes to administrative credentials, leading to potential remote code execution without
requiring prior authentication on the Java RMI interface.
Severity ?
9.8 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Affected:
V2.5-GA-01-22320 , ≤ prior
(custom)
|
|||||||
|
|||||||||
Date Public ?
2023-04-11 07:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.023Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29411",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T21:21:55.206695Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T21:22:08.895Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GA-01-22320",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GS-01-22320",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
}
],
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-18T20:49:34.059Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-29411",
"datePublished": "2023-04-18T20:49:34.059Z",
"dateReserved": "2023-04-05T20:35:41.367Z",
"dateUpdated": "2025-02-05T21:22:08.895Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-42973 (GCVE-0-2022-42973)
Vulnerability from nvd – Published: 2023-02-01 00:00 – Updated: 2025-02-05 20:06
VLAI?
Summary
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Severity ?
7.8 (High)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software |
Affected:
Windows 7, 10, 11 Windows Server 2016, 2019, 2022 , < V2.5-GA
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Date Public ?
2022-12-13 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:05.491Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-42973",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:52:15.476887Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:06:29.119Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA-01-22261",
"status": "affected",
"version": "(Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS-01-22261",
"status": "affected",
"version": "Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-12-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-01T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-42973",
"datePublished": "2023-02-01T00:00:00.000Z",
"dateReserved": "2022-10-17T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:06:29.119Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-42972 (GCVE-0-2022-42972)
Vulnerability from nvd – Published: 2023-02-01 00:00 – Updated: 2025-02-05 20:06
VLAI?
Summary
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Severity ?
7.8 (High)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software |
Affected:
Windows 7, 10, 11 Windows Server 2016, 2019, 2022 , < V2.5-GA
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Date Public ?
2022-12-13 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:05.534Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-42972",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:52:18.807602Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:06:37.394Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA-01-22261",
"status": "affected",
"version": "(Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS-01-22261",
"status": "affected",
"version": "Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-12-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-01T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-42972",
"datePublished": "2023-02-01T00:00:00.000Z",
"dateReserved": "2022-10-17T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:06:37.394Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-42971 (GCVE-0-2022-42971)
Vulnerability from nvd – Published: 2023-02-01 00:00 – Updated: 2025-02-05 20:16
VLAI?
Summary
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Severity ?
9.8 (Critical)
CWE
- CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software |
Affected:
Windows 7, 10, 11 Windows Server 2016, 2019, 2022 , < V2.5-GA
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Date Public ?
2022-12-13 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:05.546Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-42971",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:56:34.500669Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:16:59.507Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA-01-22261",
"status": "affected",
"version": "(Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS-01-22261",
"status": "affected",
"version": "Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-12-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-01T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-42971",
"datePublished": "2023-02-01T00:00:00.000Z",
"dateReserved": "2022-10-17T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:16:59.507Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-42970 (GCVE-0-2022-42970)
Vulnerability from nvd – Published: 2023-02-01 00:00 – Updated: 2025-02-05 20:17
VLAI?
Summary
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Severity ?
9.8 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software |
Affected:
Windows 7, 10, 11 Windows Server 2016, 2019, 2022 , < V2.5-GA
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Date Public ?
2022-12-13 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:05.522Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-42970",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:56:37.171973Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:17:08.771Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA-01-22261",
"status": "affected",
"version": "(Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS-01-22261",
"status": "affected",
"version": "Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-12-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-01T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-42970",
"datePublished": "2023-02-01T00:00:00.000Z",
"dateReserved": "2022-10-17T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:17:08.771Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29413 (GCVE-0-2023-29413)
Vulnerability from cvelistv5 – Published: 2023-04-18 20:50 – Updated: 2025-02-05 20:59
VLAI?
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause
Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor
service.
Severity ?
7.5 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Affected:
V2.5-GA-01-22320 , ≤ prior
(custom)
|
|||||||
|
|||||||||
Date Public ?
2023-04-11 07:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:45.947Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29413",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T20:59:10.323751Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:59:20.742Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GA-01-22320",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GS-01-22320",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n"
}
],
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-18T20:50:53.336Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-29413",
"datePublished": "2023-04-18T20:50:53.336Z",
"dateReserved": "2023-04-05T20:35:41.367Z",
"dateUpdated": "2025-02-05T20:59:20.742Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29412 (GCVE-0-2023-29412)
Vulnerability from cvelistv5 – Published: 2023-04-18 20:50 – Updated: 2025-02-05 21:00
VLAI?
Summary
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command
Injection') vulnerability exists that could cause remote code execution when manipulating
internal methods through Java RMI interface.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Affected:
V2.5-GA-01-22320 , ≤ prior
(custom)
|
|||||||
|
|||||||||
Date Public ?
2023-04-11 07:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.159Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29412",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T21:00:28.496674Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T21:00:38.906Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GA-01-22320",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GS-01-22320",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface.\n\n"
}
],
"value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command\nInjection\u0027) vulnerability exists that could cause remote code execution when manipulating\ninternal methods through Java RMI interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-12T12:20:18.929Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-29412",
"datePublished": "2023-04-18T20:50:08.288Z",
"dateReserved": "2023-04-05T20:35:41.367Z",
"dateUpdated": "2025-02-05T21:00:38.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29411 (GCVE-0-2023-29411)
Vulnerability from cvelistv5 – Published: 2023-04-18 20:49 – Updated: 2025-02-05 21:22
VLAI?
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow
changes to administrative credentials, leading to potential remote code execution without
requiring prior authentication on the Java RMI interface.
Severity ?
9.8 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022) |
Affected:
V2.5-GA-01-22320 , ≤ prior
(custom)
|
|||||||
|
|||||||||
Date Public ?
2023-04-11 07:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:07:46.023Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29411",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T21:21:55.206695Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T21:22:08.895Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "APC Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GA-01-22320",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Schneider Electric Easy UPS Online Monitoring Software (Windows 10, 11 Windows Server 2016, 2019, 2022)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "prior",
"status": "affected",
"version": "V2.5-GS-01-22320",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-11T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
}
],
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow\nchanges to administrative credentials, leading to potential remote code execution without\nrequiring prior authentication on the Java RMI interface. \n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-18T20:49:34.059Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-29411",
"datePublished": "2023-04-18T20:49:34.059Z",
"dateReserved": "2023-04-05T20:35:41.367Z",
"dateUpdated": "2025-02-05T21:22:08.895Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-42971 (GCVE-0-2022-42971)
Vulnerability from cvelistv5 – Published: 2023-02-01 00:00 – Updated: 2025-02-05 20:16
VLAI?
Summary
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Severity ?
9.8 (Critical)
CWE
- CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software |
Affected:
Windows 7, 10, 11 Windows Server 2016, 2019, 2022 , < V2.5-GA
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Date Public ?
2022-12-13 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:05.546Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-42971",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:56:34.500669Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:16:59.507Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA-01-22261",
"status": "affected",
"version": "(Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS-01-22261",
"status": "affected",
"version": "Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-12-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-01T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-42971",
"datePublished": "2023-02-01T00:00:00.000Z",
"dateReserved": "2022-10-17T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:16:59.507Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-42972 (GCVE-0-2022-42972)
Vulnerability from cvelistv5 – Published: 2023-02-01 00:00 – Updated: 2025-02-05 20:06
VLAI?
Summary
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Severity ?
7.8 (High)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software |
Affected:
Windows 7, 10, 11 Windows Server 2016, 2019, 2022 , < V2.5-GA
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Date Public ?
2022-12-13 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:05.534Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-42972",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:52:18.807602Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:06:37.394Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA-01-22261",
"status": "affected",
"version": "(Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS-01-22261",
"status": "affected",
"version": "Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-12-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-01T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-42972",
"datePublished": "2023-02-01T00:00:00.000Z",
"dateReserved": "2022-10-17T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:06:37.394Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-42970 (GCVE-0-2022-42970)
Vulnerability from cvelistv5 – Published: 2023-02-01 00:00 – Updated: 2025-02-05 20:17
VLAI?
Summary
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Severity ?
9.8 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software |
Affected:
Windows 7, 10, 11 Windows Server 2016, 2019, 2022 , < V2.5-GA
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Date Public ?
2022-12-13 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:05.522Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-42970",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:56:37.171973Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:17:08.771Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA-01-22261",
"status": "affected",
"version": "(Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS-01-22261",
"status": "affected",
"version": "Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-12-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-01T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-42970",
"datePublished": "2023-02-01T00:00:00.000Z",
"dateReserved": "2022-10-17T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:17:08.771Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-42973 (GCVE-0-2022-42973)
Vulnerability from cvelistv5 – Published: 2023-02-01 00:00 – Updated: 2025-02-05 20:06
VLAI?
Summary
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Severity ?
7.8 (High)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software |
Affected:
Windows 7, 10, 11 Windows Server 2016, 2019, 2022 , < V2.5-GA
(custom)
|
|||||||||||||||||
|
|||||||||||||||||||
Date Public ?
2022-12-13 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:05.491Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-42973",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:52:15.476887Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:06:29.119Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA-01-22261",
"status": "affected",
"version": "(Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS-01-22261",
"status": "affected",
"version": "Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-12-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-01T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-42973",
"datePublished": "2023-02-01T00:00:00.000Z",
"dateReserved": "2022-10-17T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:06:29.119Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}