Search criteria
8 vulnerabilities found for andover_continuum_9941_firmware by schneider-electric
CVE-2020-7482 (GCVE-0-2020-7482)
Vulnerability from nvd – Published: 2020-03-23 19:23 – Updated: 2024-08-04 09:33
VLAI?
Summary
A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products' web server.
Severity ?
No CVSS data available.
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Andover Continuum (All versions) |
Affected:
Andover Continuum (All versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:18.775Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Andover Continuum (All versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Andover Continuum (All versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products\u0027 web server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-23T19:23:57",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7482",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Andover Continuum (All versions)",
"version": {
"version_data": [
{
"version_value": "Andover Continuum (All versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products\u0027 web server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7482",
"datePublished": "2020-03-23T19:23:57",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:18.775Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7481 (GCVE-0-2020-7481)
Vulnerability from nvd – Published: 2020-03-23 19:23 – Updated: 2024-08-04 09:33
VLAI?
Summary
A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products' web server.
Severity ?
No CVSS data available.
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Andover Continuum (All versions) |
Affected:
Andover Continuum (All versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.682Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Andover Continuum (All versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Andover Continuum (All versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products\u0027 web server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-23T19:23:49",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7481",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Andover Continuum (All versions)",
"version": {
"version_data": [
{
"version_value": "Andover Continuum (All versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products\u0027 web server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7481",
"datePublished": "2020-03-23T19:23:49",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.682Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7480 (GCVE-0-2020-7480)
Vulnerability from nvd – Published: 2020-03-23 19:24 – Updated: 2024-08-04 09:33
VLAI?
Summary
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data.
Severity ?
No CVSS data available.
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Andover Continuum (All versions) |
Affected:
Andover Continuum (All versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.649Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Andover Continuum (All versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Andover Continuum (All versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application\u0027s processing of XML data."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-23T19:24:37",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7480",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Andover Continuum (All versions)",
"version": {
"version_data": [
{
"version_value": "Andover Continuum (All versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application\u0027s processing of XML data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7480",
"datePublished": "2020-03-23T19:24:37",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.649Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6853 (GCVE-0-2019-6853)
Vulnerability from nvd – Published: 2019-11-20 22:01 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server.
Severity ?
No CVSS data available.
CWE
- CWE-79 - Failure to Preserve Web Page Structure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702 |
Affected:
Andover Continuum models 9680
Affected: 5740 and 5720 Affected: bCX4040 Affected: bCX9640 Affected: 9900 Affected: 9940 Affected: 9924 and 9702 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.456Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-316-01/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Andover Continuum models 9680"
},
{
"status": "affected",
"version": "5740 and 5720"
},
{
"status": "affected",
"version": "bCX4040"
},
{
"status": "affected",
"version": "bCX9640"
},
{
"status": "affected",
"version": "9900"
},
{
"status": "affected",
"version": "9940"
},
{
"status": "affected",
"version": "9924 and 9702"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Failure to Preserve Web Page Structure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-20T22:01:18",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-316-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6853",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702",
"version": {
"version_data": [
{
"version_value": "Andover Continuum models 9680"
},
{
"version_value": "5740 and 5720"
},
{
"version_value": "bCX4040"
},
{
"version_value": "bCX9640"
},
{
"version_value": "9900"
},
{
"version_value": "9940"
},
{
"version_value": "9924 and 9702"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Failure to Preserve Web Page Structure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2019-316-01/",
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-316-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6853",
"datePublished": "2019-11-20T22:01:18",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.456Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7480 (GCVE-0-2020-7480)
Vulnerability from cvelistv5 – Published: 2020-03-23 19:24 – Updated: 2024-08-04 09:33
VLAI?
Summary
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data.
Severity ?
No CVSS data available.
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Andover Continuum (All versions) |
Affected:
Andover Continuum (All versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.649Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Andover Continuum (All versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Andover Continuum (All versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application\u0027s processing of XML data."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-23T19:24:37",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7480",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Andover Continuum (All versions)",
"version": {
"version_data": [
{
"version_value": "Andover Continuum (All versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application\u0027s processing of XML data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7480",
"datePublished": "2020-03-23T19:24:37",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.649Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7482 (GCVE-0-2020-7482)
Vulnerability from cvelistv5 – Published: 2020-03-23 19:23 – Updated: 2024-08-04 09:33
VLAI?
Summary
A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products' web server.
Severity ?
No CVSS data available.
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Andover Continuum (All versions) |
Affected:
Andover Continuum (All versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:18.775Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Andover Continuum (All versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Andover Continuum (All versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products\u0027 web server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-23T19:23:57",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7482",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Andover Continuum (All versions)",
"version": {
"version_data": [
{
"version_value": "Andover Continuum (All versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products\u0027 web server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7482",
"datePublished": "2020-03-23T19:23:57",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:18.775Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7481 (GCVE-0-2020-7481)
Vulnerability from cvelistv5 – Published: 2020-03-23 19:23 – Updated: 2024-08-04 09:33
VLAI?
Summary
A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products' web server.
Severity ?
No CVSS data available.
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Andover Continuum (All versions) |
Affected:
Andover Continuum (All versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.682Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Andover Continuum (All versions)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Andover Continuum (All versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products\u0027 web server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-23T19:23:49",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7481",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Andover Continuum (All versions)",
"version": {
"version_data": [
{
"version_value": "Andover Continuum (All versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products\u0027 web server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79:Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7481",
"datePublished": "2020-03-23T19:23:49",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.682Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6853 (GCVE-0-2019-6853)
Vulnerability from cvelistv5 – Published: 2019-11-20 22:01 – Updated: 2024-08-04 20:31
VLAI?
Summary
A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server.
Severity ?
No CVSS data available.
CWE
- CWE-79 - Failure to Preserve Web Page Structure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702 |
Affected:
Andover Continuum models 9680
Affected: 5740 and 5720 Affected: bCX4040 Affected: bCX9640 Affected: 9900 Affected: 9940 Affected: 9924 and 9702 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.456Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-316-01/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Andover Continuum models 9680"
},
{
"status": "affected",
"version": "5740 and 5720"
},
{
"status": "affected",
"version": "bCX4040"
},
{
"status": "affected",
"version": "bCX9640"
},
{
"status": "affected",
"version": "9900"
},
{
"status": "affected",
"version": "9940"
},
{
"status": "affected",
"version": "9924 and 9702"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Failure to Preserve Web Page Structure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-20T22:01:18",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-316-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6853",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702",
"version": {
"version_data": [
{
"version_value": "Andover Continuum models 9680"
},
{
"version_value": "5740 and 5720"
},
{
"version_value": "bCX4040"
},
{
"version_value": "bCX9640"
},
{
"version_value": "9900"
},
{
"version_value": "9940"
},
{
"version_value": "9924 and 9702"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Failure to Preserve Web Page Structure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2019-316-01/",
"refsource": "CONFIRM",
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-316-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6853",
"datePublished": "2019-11-20T22:01:18",
"dateReserved": "2019-01-25T00:00:00",
"dateUpdated": "2024-08-04T20:31:04.456Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}