Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

10 vulnerabilities found for alarm_system by hozard

CVE-2023-50128 (GCVE-0-2023-50128)

Vulnerability from nvd – Published: 2024-01-11 00:00 – Updated: 2025-06-20 16:16
VLAI?
Summary
The remote keyless system of the Hozard alarm system (alarmsystemen) v1.0 sends an identical radio frequency signal for each request, which results in an attacker being able to conduct replay attacks to bring the alarm system to a disarmed state.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:09:49.731Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://hozard.com"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-50128",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-12T18:02:26.210584Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-294",
                "description": "CWE-294 Authentication Bypass by Capture-replay",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-20T16:16:01.119Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The remote keyless system of the Hozard alarm system (alarmsystemen) v1.0 sends an identical radio frequency signal for each request, which results in an attacker being able to conduct replay attacks to bring the alarm system to a disarmed state."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-11T20:23:13.183Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
        },
        {
          "url": "http://hozard.com"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-50128",
    "datePublished": "2024-01-11T00:00:00.000Z",
    "dateReserved": "2023-12-04T00:00:00.000Z",
    "dateUpdated": "2025-06-20T16:16:01.119Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-50127 (GCVE-0-2023-50127)

Vulnerability from nvd – Published: 2024-01-11 00:00 – Updated: 2025-06-20 16:15
VLAI?
Summary
Hozard alarm system (Alarmsysteem) v1.0 is vulnerable to Improper Authentication. Commands sent via the SMS functionality are accepted from random phone numbers, which allows an attacker to bring the alarm system to a disarmed state from any given phone number.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:09:49.699Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-50127",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-12T17:57:13.477111Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-287",
                "description": "CWE-287 Improper Authentication",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-20T16:15:07.271Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Hozard alarm system (Alarmsysteem) v1.0 is vulnerable to Improper Authentication. Commands sent via the SMS functionality are accepted from random phone numbers, which allows an attacker to bring the alarm system to a disarmed state from any given phone number."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-11T20:22:49.508Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-50127",
    "datePublished": "2024-01-11T00:00:00.000Z",
    "dateReserved": "2023-12-04T00:00:00.000Z",
    "dateUpdated": "2025-06-20T16:15:07.271Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-50126 (GCVE-0-2023-50126)

Vulnerability from nvd – Published: 2024-01-11 00:00 – Updated: 2025-06-03 14:25
VLAI?
Summary
Missing encryption in the RFID tags of the Hozard alarm system (Alarmsysteem) v1.0 allow attackers to create a cloned tag via brief physical proximity to one of the original tags, which results in an attacker being able to bring the alarm system to a disarmed state.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:09:49.694Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-50126",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-08T17:36:18.425359Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-311",
                "description": "CWE-311 Missing Encryption of Sensitive Data",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-03T14:25:48.077Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Missing encryption in the RFID tags of the Hozard alarm system (Alarmsysteem) v1.0 allow attackers to create a cloned tag via brief physical proximity to one of the original tags, which results in an attacker being able to bring the alarm system to a disarmed state."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-11T20:22:14.930Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-50126",
    "datePublished": "2024-01-11T00:00:00.000Z",
    "dateReserved": "2023-12-04T00:00:00.000Z",
    "dateUpdated": "2025-06-03T14:25:48.077Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-50125 (GCVE-0-2023-50125)

Vulnerability from nvd – Published: 2024-01-11 00:00 – Updated: 2025-06-20 16:14
VLAI?
Summary
A default engineer password set on the Hozard alarm system (Alarmsysteem) v1.0 allows an attacker to bring the alarm system to a disarmed state.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:09:49.670Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-50125",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-12T17:57:08.047694Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-522",
                "description": "CWE-522 Insufficiently Protected Credentials",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-20T16:14:10.202Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A default engineer password set on the Hozard alarm system (Alarmsysteem) v1.0 allows an attacker to bring the alarm system to a disarmed state."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-11T20:21:48.426Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-50125",
    "datePublished": "2024-01-11T00:00:00.000Z",
    "dateReserved": "2023-12-04T00:00:00.000Z",
    "dateUpdated": "2025-06-20T16:14:10.202Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-50123 (GCVE-0-2023-50123)

Vulnerability from nvd – Published: 2024-01-11 00:00 – Updated: 2025-06-20 16:13
VLAI?
Summary
The number of attempts to bring the Hozard Alarm system (alarmsystemen) v1.0 to a disarmed state is not limited. This could allow an attacker to perform a brute force on the SMS authentication, to bring the alarm system to a disarmed state.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:09:49.606Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-50123",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-12T18:00:12.324614Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-307",
                "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-20T16:13:24.396Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The number of attempts to bring the Hozard Alarm system (alarmsystemen) v1.0 to a disarmed state is not limited. This could allow an attacker to perform a brute force on the SMS authentication, to bring the alarm system to a disarmed state."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-11T20:20:58.607Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-50123",
    "datePublished": "2024-01-11T00:00:00.000Z",
    "dateReserved": "2023-12-04T00:00:00.000Z",
    "dateUpdated": "2025-06-20T16:13:24.396Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-50128 (GCVE-0-2023-50128)

Vulnerability from cvelistv5 – Published: 2024-01-11 00:00 – Updated: 2025-06-20 16:16
VLAI?
Summary
The remote keyless system of the Hozard alarm system (alarmsystemen) v1.0 sends an identical radio frequency signal for each request, which results in an attacker being able to conduct replay attacks to bring the alarm system to a disarmed state.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:09:49.731Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://hozard.com"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-50128",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-12T18:02:26.210584Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-294",
                "description": "CWE-294 Authentication Bypass by Capture-replay",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-20T16:16:01.119Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The remote keyless system of the Hozard alarm system (alarmsystemen) v1.0 sends an identical radio frequency signal for each request, which results in an attacker being able to conduct replay attacks to bring the alarm system to a disarmed state."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-11T20:23:13.183Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
        },
        {
          "url": "http://hozard.com"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-50128",
    "datePublished": "2024-01-11T00:00:00.000Z",
    "dateReserved": "2023-12-04T00:00:00.000Z",
    "dateUpdated": "2025-06-20T16:16:01.119Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-50123 (GCVE-0-2023-50123)

Vulnerability from cvelistv5 – Published: 2024-01-11 00:00 – Updated: 2025-06-20 16:13
VLAI?
Summary
The number of attempts to bring the Hozard Alarm system (alarmsystemen) v1.0 to a disarmed state is not limited. This could allow an attacker to perform a brute force on the SMS authentication, to bring the alarm system to a disarmed state.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:09:49.606Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-50123",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-12T18:00:12.324614Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-307",
                "description": "CWE-307 Improper Restriction of Excessive Authentication Attempts",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-20T16:13:24.396Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The number of attempts to bring the Hozard Alarm system (alarmsystemen) v1.0 to a disarmed state is not limited. This could allow an attacker to perform a brute force on the SMS authentication, to bring the alarm system to a disarmed state."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-11T20:20:58.607Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-50123",
    "datePublished": "2024-01-11T00:00:00.000Z",
    "dateReserved": "2023-12-04T00:00:00.000Z",
    "dateUpdated": "2025-06-20T16:13:24.396Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-50126 (GCVE-0-2023-50126)

Vulnerability from cvelistv5 – Published: 2024-01-11 00:00 – Updated: 2025-06-03 14:25
VLAI?
Summary
Missing encryption in the RFID tags of the Hozard alarm system (Alarmsysteem) v1.0 allow attackers to create a cloned tag via brief physical proximity to one of the original tags, which results in an attacker being able to bring the alarm system to a disarmed state.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:09:49.694Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-50126",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-08T17:36:18.425359Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-311",
                "description": "CWE-311 Missing Encryption of Sensitive Data",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-03T14:25:48.077Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Missing encryption in the RFID tags of the Hozard alarm system (Alarmsysteem) v1.0 allow attackers to create a cloned tag via brief physical proximity to one of the original tags, which results in an attacker being able to bring the alarm system to a disarmed state."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-11T20:22:14.930Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-50126",
    "datePublished": "2024-01-11T00:00:00.000Z",
    "dateReserved": "2023-12-04T00:00:00.000Z",
    "dateUpdated": "2025-06-03T14:25:48.077Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-50127 (GCVE-0-2023-50127)

Vulnerability from cvelistv5 – Published: 2024-01-11 00:00 – Updated: 2025-06-20 16:15
VLAI?
Summary
Hozard alarm system (Alarmsysteem) v1.0 is vulnerable to Improper Authentication. Commands sent via the SMS functionality are accepted from random phone numbers, which allows an attacker to bring the alarm system to a disarmed state from any given phone number.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:09:49.699Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-50127",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-12T17:57:13.477111Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-287",
                "description": "CWE-287 Improper Authentication",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-20T16:15:07.271Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Hozard alarm system (Alarmsysteem) v1.0 is vulnerable to Improper Authentication. Commands sent via the SMS functionality are accepted from random phone numbers, which allows an attacker to bring the alarm system to a disarmed state from any given phone number."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-11T20:22:49.508Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-50127",
    "datePublished": "2024-01-11T00:00:00.000Z",
    "dateReserved": "2023-12-04T00:00:00.000Z",
    "dateUpdated": "2025-06-20T16:15:07.271Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-50125 (GCVE-0-2023-50125)

Vulnerability from cvelistv5 – Published: 2024-01-11 00:00 – Updated: 2025-06-20 16:14
VLAI?
Summary
A default engineer password set on the Hozard alarm system (Alarmsysteem) v1.0 allows an attacker to bring the alarm system to a disarmed state.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T22:09:49.670Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-50125",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-12T17:57:08.047694Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-522",
                "description": "CWE-522 Insufficiently Protected Credentials",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-20T16:14:10.202Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A default engineer password set on the Hozard alarm system (Alarmsysteem) v1.0 allows an attacker to bring the alarm system to a disarmed state."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-11T20:21:48.426Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.secura.com/services/iot/consumer-products/security-concerns-in-popular-smart-home-devices"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-50125",
    "datePublished": "2024-01-11T00:00:00.000Z",
    "dateReserved": "2023-12-04T00:00:00.000Z",
    "dateUpdated": "2025-06-20T16:14:10.202Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}