Search criteria

4 vulnerabilities found for accutech_manager by schneider-electric

CVE-2023-29414 (GCVE-0-2023-29414)

Vulnerability from nvd – Published: 2023-07-12 08:18 – Updated: 2024-11-07 14:44
VLAI?
Summary
A CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability exists that could cause user privilege escalation if a local user sends specific string input to a local function call.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
Impacted products
Vendor Product Version
Schneider Electric Accutech Manager Affected: Version 2.7 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:07:45.730Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-03.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:schneider-electric:accutech_manager:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "accutech_manager",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "2.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-29414",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-07T14:42:01.511585Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-07T14:44:09.486Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Accutech Manager",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 2.7 and prior"
            }
          ]
        }
      ],
      "datePublic": "2023-07-11T08:17:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nA CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability\nexists that could cause user privilege escalation if a local user sends specific string input to a\nlocal function call.\n\n"
            }
          ],
          "value": "\nA CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability\nexists that could cause user privilege escalation if a local user sends specific string input to a\nlocal function call.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-07-12T08:18:01.709Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2023-29414",
    "datePublished": "2023-07-12T08:18:01.709Z",
    "dateReserved": "2023-04-05T20:35:41.368Z",
    "dateUpdated": "2024-11-07T14:44:09.486Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-0658 (GCVE-0-2013-0658)

Vulnerability from nvd – Published: 2013-02-15 11:00 – Updated: 2024-09-17 03:48
VLAI?
Summary
Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T14:33:05.760Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-043-01.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-02-15T11:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-043-01.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-0658",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-043-01.pdf",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-043-01.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-0658",
    "datePublished": "2013-02-15T11:00:00Z",
    "dateReserved": "2012-12-19T00:00:00Z",
    "dateUpdated": "2024-09-17T03:48:46.517Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-29414 (GCVE-0-2023-29414)

Vulnerability from cvelistv5 – Published: 2023-07-12 08:18 – Updated: 2024-11-07 14:44
VLAI?
Summary
A CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability exists that could cause user privilege escalation if a local user sends specific string input to a local function call.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
Impacted products
Vendor Product Version
Schneider Electric Accutech Manager Affected: Version 2.7 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:07:45.730Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-03.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:schneider-electric:accutech_manager:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "accutech_manager",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "2.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-29414",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-07T14:42:01.511585Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-07T14:44:09.486Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Accutech Manager",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 2.7 and prior"
            }
          ]
        }
      ],
      "datePublic": "2023-07-11T08:17:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nA CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability\nexists that could cause user privilege escalation if a local user sends specific string input to a\nlocal function call.\n\n"
            }
          ],
          "value": "\nA CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability\nexists that could cause user privilege escalation if a local user sends specific string input to a\nlocal function call.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-07-12T08:18:01.709Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2023-29414",
    "datePublished": "2023-07-12T08:18:01.709Z",
    "dateReserved": "2023-04-05T20:35:41.368Z",
    "dateUpdated": "2024-11-07T14:44:09.486Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-0658 (GCVE-0-2013-0658)

Vulnerability from cvelistv5 – Published: 2013-02-15 11:00 – Updated: 2024-09-17 03:48
VLAI?
Summary
Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T14:33:05.760Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-043-01.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-02-15T11:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-043-01.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-0658",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/pdf/ICSA-13-043-01.pdf",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-043-01.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-0658",
    "datePublished": "2013-02-15T11:00:00Z",
    "dateReserved": "2012-12-19T00:00:00Z",
    "dateUpdated": "2024-09-17T03:48:46.517Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}