Search criteria

6 vulnerabilities found for ac10v4_firmware by tenda

CVE-2023-40904 (GCVE-0-2023-40904)

Vulnerability from nvd – Published: 2023-08-24 00:00 – Updated: 2024-10-02 20:29
VLAI
Summary
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • n/a
  • CWE-787 - Out-of-bounds Write
Assigner
Impacted products
Vendor Product Version
tenda ac10v4_firmware Affected: 16.03.10.13
    cpe:2.3:o:tenda:ac10v4_firmware:16.03.10.13:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T18:46:11.593Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/formSetMacFilterCfg/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10v4_firmware:16.03.10.13:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10v4_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.10.13"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-40904",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-02T20:24:34.141892Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-02T20:29:06.848Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-24T17:23:52.268Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/formSetMacFilterCfg/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-40904",
    "datePublished": "2023-08-24T00:00:00.000Z",
    "dateReserved": "2023-08-22T00:00:00.000Z",
    "dateUpdated": "2024-10-02T20:29:06.848Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-40902 (GCVE-0-2023-40902)

Vulnerability from nvd – Published: 2023-08-24 00:00 – Updated: 2024-10-02 20:43
VLAI
Summary
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
Severity
No CVSS data available.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • n/a
Assigner
Impacted products
Vendor Product Version
tenda ac10v4 Affected: us_ac10v4.0si_v16.03.10.13_cn
    cpe:2.3:a:tenda:ac10v4:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T18:46:11.116Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/SetIpMacBind/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:tenda:ac10v4:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10v4",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "us_ac10v4.0si_v16.03.10.13_cn"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-40902",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-02T20:41:31.480609Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-02T20:43:18.302Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-24T17:21:22.365Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/SetIpMacBind/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-40902",
    "datePublished": "2023-08-24T00:00:00.000Z",
    "dateReserved": "2023-08-22T00:00:00.000Z",
    "dateUpdated": "2024-10-02T20:43:18.302Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-40901 (GCVE-0-2023-40901)

Vulnerability from nvd – Published: 2023-08-24 00:00 – Updated: 2024-10-02 20:46
VLAI
Summary
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg.
Severity
No CVSS data available.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • n/a
Assigner
Impacted products
Vendor Product Version
tenda ac10 Affected: v4_us_ac10v4.0si_v16.03.10.13_cn
    cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T18:46:11.214Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/fromSetStaticRouteCfg/1.md"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/formSetMacFilterCfg/1.md"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-40901"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v4_us_ac10v4.0si_v16.03.10.13_cn"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-40901",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-02T20:45:05.774318Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-02T20:46:45.169Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T21:04:29.293Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/fromSetStaticRouteCfg/1.md"
        },
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/formSetMacFilterCfg/1.md"
        },
        {
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-40901"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-40901",
    "datePublished": "2023-08-24T00:00:00.000Z",
    "dateReserved": "2023-08-22T00:00:00.000Z",
    "dateUpdated": "2024-10-02T20:46:45.169Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-40901 (GCVE-0-2023-40901)

Vulnerability from cvelistv5 – Published: 2023-08-24 00:00 – Updated: 2024-10-02 20:46
VLAI
Summary
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg.
Severity
No CVSS data available.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • n/a
Assigner
Impacted products
Vendor Product Version
tenda ac10 Affected: v4_us_ac10v4.0si_v16.03.10.13_cn
    cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T18:46:11.214Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/fromSetStaticRouteCfg/1.md"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/formSetMacFilterCfg/1.md"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-40901"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v4_us_ac10v4.0si_v16.03.10.13_cn"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-40901",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-02T20:45:05.774318Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-02T20:46:45.169Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T21:04:29.293Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/fromSetStaticRouteCfg/1.md"
        },
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/formSetMacFilterCfg/1.md"
        },
        {
          "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-40901"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-40901",
    "datePublished": "2023-08-24T00:00:00.000Z",
    "dateReserved": "2023-08-22T00:00:00.000Z",
    "dateUpdated": "2024-10-02T20:46:45.169Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-40902 (GCVE-0-2023-40902)

Vulnerability from cvelistv5 – Published: 2023-08-24 00:00 – Updated: 2024-10-02 20:43
VLAI
Summary
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
Severity
No CVSS data available.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • n/a
Assigner
Impacted products
Vendor Product Version
tenda ac10v4 Affected: us_ac10v4.0si_v16.03.10.13_cn
    cpe:2.3:a:tenda:ac10v4:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T18:46:11.116Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/SetIpMacBind/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:tenda:ac10v4:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10v4",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "us_ac10v4.0si_v16.03.10.13_cn"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-40902",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-02T20:41:31.480609Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-02T20:43:18.302Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-24T17:21:22.365Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/SetIpMacBind/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-40902",
    "datePublished": "2023-08-24T00:00:00.000Z",
    "dateReserved": "2023-08-22T00:00:00.000Z",
    "dateUpdated": "2024-10-02T20:43:18.302Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-40904 (GCVE-0-2023-40904)

Vulnerability from cvelistv5 – Published: 2023-08-24 00:00 – Updated: 2024-10-02 20:29
VLAI
Summary
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • n/a
  • CWE-787 - Out-of-bounds Write
Assigner
Impacted products
Vendor Product Version
tenda ac10v4_firmware Affected: 16.03.10.13
    cpe:2.3:o:tenda:ac10v4_firmware:16.03.10.13:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T18:46:11.593Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/formSetMacFilterCfg/1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10v4_firmware:16.03.10.13:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10v4_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.10.13"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-40904",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-02T20:24:34.141892Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-02T20:29:06.848Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-24T17:23:52.268Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/peris-navince/founded-0-days/blob/main/ac10/formSetMacFilterCfg/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-40904",
    "datePublished": "2023-08-24T00:00:00.000Z",
    "dateReserved": "2023-08-22T00:00:00.000Z",
    "dateUpdated": "2024-10-02T20:29:06.848Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}